Laserfiche WebLink
E3 UNIT VARIATIONS ' <br /> A - BASIC PORCH/ NO POPOUT AT REAR <br /> B - BASIC PORCH/ POPOUT AT REAR . <br /> C - ENHANCED PORCH/ NO POPOUT AT REAR <br /> D - ENHANCED PORCH/ POPOUT AT REAR <br /> SEE BUILDING PLANS FOR WHERE <br /> , <br /> VARIATIONS OCCUR <br /> � � � � � q � '� � + <br /> , <br /> f � C C ;'�l � „� � t' $ 5 ; <br /> INSULATION ' ' <br /> : �` � � ; <br /> _ �� ��r�rr;�� w�y� s��t� 2t�1 .: <br /> FOUNDATIQN RERIMETER - R-10 R(GID . <br /> ������n�t1F�/t�s�ati�`��n� ��4�33' <br /> INSULATION TO A DEPTH OF 24" OR TO TOP <br /> �,`������.�:�'�,�f� �"�2�b�8 ���� <br /> OF FOOTING AT HEATED PERIMETER ' ` <br /> . �Jfe1�.�<������r+���#���`e� r�rxr <br /> WALLS: 2x6 WALLS WITH FIBERGLASS BATTS <br /> ; <br /> OR BLANKETS - R21 <br /> FLOORS OVER UNHEATED SPACES - R-30 <br /> 5052 REGISTERED , <br /> ATTICS AT TRUSSES - R-49 � <br /> (R-38 SHALL BE DEEMED TO SATISFY THE ARCHITECT <br /> REQUIREMENT OF R-49 WHEREVER THE FULL � <br /> HEIGHT OF UNCOMPRESSED INSULATION EXTENDS <br /> OVER THE WALL TOP PLATE AT THE EAVES) <br /> ROBERT E. WEIBLE <br /> STATE OF WASHINGTON ` <br /> EXTERIOR DOORS: DOORS BETWEEN HEATED <br /> AND UNHEATEQ SPACES SHALL BE U=0.30 � � <br /> OR BETTER <br /> WINDOWS: ALL WINDOWS AND SGD TO HAVE <br /> � <br /> � <br /> 7 <br /> U-FACTOR QF U=0.30 OR BETTER <br /> � <br /> N <br /> INSULATE UNDER STAIRS AND IN WALL <br /> I � <br /> CAVITIES ABOVE BOTTOM QF STRINGERS ' <br /> � <br /> � <br /> � <br /> .� <br /> a <br /> GYPSUM WALLBOARD SCHEDULE <br /> � <br /> a <br /> u <br /> %a" GYPSUM WALLBOARD (GWB) SHALL BE � <br /> USED THROUGHOUT ON INTERIOR WALLS, <br /> INTERIOR SIDE OF EXTERIOR WALLS AND � <br /> CEILINGS EXCEPT AT EXTERIOR WALL.S AND � � <br /> s <br /> COMMON WALLS REQUIRED TO HAVE A 9-HR <br /> a <br /> OR 2-HR FIRE-RESISTANCE RATING IN <br /> � <br /> WHICH CASE 5/8" TYPE 'X' GWB SHALL BE ' <br /> a <br /> USED. <br /> � <br /> � <br /> a <br /> � <br /> � <br /> � � � <br /> a .� <br /> I � � <br /> � <br /> � � <br /> i o V <br /> Z o <br /> � <br /> � M � � <br /> W � � <br /> � N <br /> m , <br /> c � <br /> � � � <br /> , � <br /> M �° <br /> � <br /> , <br /> W z � � <br /> c N <br /> o � <br /> Q � <br /> n � <br /> W a <br /> M � <br /> W °o m � <br /> n � 3 � <br /> Q � � � <br /> M <br /> W <br /> � o <br /> �, � � <br /> .� a u <br /> � � <br /> � <br /> � <br /> j I� � j � i i( ( ABO WALLS, BEAM��S, ANDUPOST9 � <br /> it� N N Z � i i ii � i i WITHIN GARAGE. <br /> g " . I � ��-__ � ' �, Carage <br /> c� ¢ ; 1 � � � 16 -� � I � <br /> � � :. . i , ; i �� D3 SIM. j 4�-'" 5-�� 9-9yZ� � °' � <br /> � ? . . . i � � � � , � <br /> � Q ----. :. . . . . . . . . . . .�-.-. .------ , o L ---;�. <br /> • �n.-._�. n <br /> � ........ ....................................... <br /> . �w . . .':�,,j.'. . . . . . . . . . . . . . . . . . ..'.'. . '---- -- � �I � -------- - --'�"�'�'�'�'�'�'� - ------- ------- ---- � <br /> 1 INSULATE SOFFlT AROUND�BEAM ` <br /> N O T E S � : -- ---- --------"--------------� � -—- __ I � UNDER AND BATH EXHAUST � /1 <br /> � `- 10 ��2 ^ OFFIT 16 OFF CEILING z, S,> � �STAIRS 8 �, _ <br /> FRAMING: 2x6's AT EXTERIOR WALLS THE FIREPLACE SHALL BE LISTED BY UL OR FM AND ---- � N � �` <br /> -�I- D5 P n (� "� �j � I I �� � � <br /> � �, � 2 i CONTINUE COMMON WALL <br /> SHALL BE INSTALLED IN ACCORDANCE WITH THAT � 2 � 1� � � � <br /> 2x4's AT INTERIOR WALLS � <br /> UNLESS NOTED OTHERWISE. LfSTWG i ¢ D1 D5 "' GWB THROUGH FURRING � <br /> � • �j .... ... ... uP pz 9 3 i <br /> SE� S1.1 FOR STUD SCHEDULE. • TYPICAL 1� � 5 ' - ' O <br /> E W A T E R R E S�S T A N T G Y P S U M W A�L B O A R Q SIM. � <br /> : <br /> ; . . �. . . . . . . . _ D5 — <br /> PRavi� ' � ♦ <br /> •••••••••••••••••• R-21 BATT INSULATION BEHIND TUB AND SHOWER ENCLOSURE MATERIALS � = j� � siM. � �� • , � <br /> � � � ' � t a c� .... •��.. .�..� , � Q +�+ V <br /> . ------ 3�/2" ACOUST. INSUL. EACN SIDE TO A HEIGHT OF 70" MINIMUM ABOVE THE t. . . . . . . SOFFIT C�? DICI,/Fam. � � °t � o. 3� � 0 3 �°��'' � �s '� /�+ � <br /> OF PARTY WALL, UNO. DRAIN WLET. . 7 -10 A.F.F. � , �� _ <br /> � » ' �° LOW WALL AT . ��� _ �� a Bath � N l D3 � W � � <br /> 0 o i � � ,r, SIM. 'L�, V/ <br /> N � I f18" ABOYE : o N 1 24'Te � � <br /> � Pw�r . � a� <br /> I x � ^ ^ NOSING. RAI�ING � a a i <br /> CONCEALED SPACES SHALL BE F(RESTOPPED IN BOTH NO PLUMBING, MECHANICAL EQUIPMENT, DUCTS OR � ; 24"'TB � � ABOVE 70+36p i o O N � <br /> DIRECTIONS AT 10'-0" ON CENTER ANQ AT FLOORS. VENTS SNALL BE LOCATED IN TNE COMMON UNfT INSULATE FLOOR OVER ; <br /> • ° 2-6 HC i 2 LOCATE PI � <br /> TYPICAL. SEPARATION WALLS PER IRC SEG R302.2 (EXCEPTION) . . UNHEATED SPACE j s p, ROUGH-IN � <br /> z � UP D5 I � FOR (2) L � � S <br /> 7P. . , . .'. � 4- AT COMMC <br /> ; : � . . . <br /> -� _ � � � <br /> ALL ESCAPE OR RESCtJE WINDOWS FROM SLEEPING ALL BEDROOM AND BATHRQOM DOORS SHALL BE ••••••••-• •••••••••••••••••�•••• ••••••••••••� _� 3 Entry 2, 6, 2._oy.� ,._3y. a,; L <br /> 3 „ 1-6 ,2-6 F � 7-0 5-� DBL SL � 'o °' ���: � � � � L Q <br /> ROOMS SHALL HAVE A MiNIMUM NET CLEAR OPENING UNDERCUT A MINIMUM OF /4 ABOVE THE ADJACENT � ' <br /> OF 5.7 SQUARE FEET. TNE MlNIMUM CLEAR OPENING FLOOR COVERING. �° AT 6'-9 " ABOV : AT 8'-0" A.F.F. ' <br /> ......: N " � .. ,.. Bedroom 3 � � � 0 G� Z <br /> HEIGH7 DIMENSION SHALL BE 24". THE MINIMllM CLEAR AN G �•••••• <br /> QPENING WIDTH DIMENSION SHALL BE 20". SILL THE FRONT DOOR SHALL BE OPENABLE FROM THE --� ( L---� ' • � 8 ~ W = <br /> � � y. y24 e � o, <br /> HEIGHT SHALL BE NOT MORE THAN 44" ABOVE THE INSIDE WITHOUT THE USE aF A KEY OR ANY SPECIAL � 2•-3 2�-3 <br /> I N � � m O <br /> FLOOR PER 1RC SEC. R310.1.1. KNOWLEDGE OR EF�ORT. IT MAY BE PROVIDED WITH A � <br /> � � � ( POrC�I I � s-o�s� � � <br /> NIGHT LATCH, DEAD BOLT OR SECURfTY CHAIN, ' <br /> I � � • A7 6'-8'AF.F. � <br /> WNERE SILL AT OPERABLE WINDOW IS LOCATED MORE PRQV(DED SUCH DEVICES ARE QPENABLE FROM THE � ����� ���������� �� <br /> THAN 72 INCHES ABOVE FINISHED GRADE OR OTHER INSIDE WITHOUT THE USE OF A KEY OR TOOL, AND � ' „s�-s3/4- z�_e� o ------ �� _ � <br /> � <br /> M � � �_ t � Dt 0 <br /> SURFACE BELOW, SILL NEIGHT SHALL BE MINIMUM 24 MOUNTED NOT TO EXGEED 48" ABOVE THE F(NISHED ' ' � ' � � � - �� �` � <br /> 2-9' 2 -4" 5 -0" 5 -0' i i � oz � � a <br /> INCHES ABOVE FINISHED FLOOR. PER IRC SEC. 312.2.1. FLOOR. -- --- <br /> 5'_�" 2'-p" 10�-0" 2'-0" '- � � � � <br /> � �'-�Ys" <br /> �2 uP l�' <br /> ALL GLAZING SHALL CONFORM TQ (RC SEC. R308.4, STAfR NOTES: 19'-1" <br /> HAZARDOUS LOCATIONS. GLAZING IN ALL DOORS SHALL LOCATE HANDRAILS AT 34'-38" ABOVE THE os 5 9� <br /> r-�Ys r-�+Y4 � <br /> BE SAFETY GLAZED. ALL GLAZING WITHiN A 24" ARC STAIR NOSING. <br /> OF EITHER VERTICAL DOOR EDGE SHALL BE SAFETY U N IT E3A & E3 B MIDQLE LEVEL PLAN <br /> GLAZED. ALL GLAZING WITHIN 60" OF A HAZARDOUS HANDRA(L GRASP DIMENSION SHALL BE BETWEEN 1" & � <br /> LOCAT(ON, OR "WET SURFACE" SHALL BE SAFETY 1-1/4". PROVIDE CONTINUOUS HANDRAIL OR 1�4"=1'-0" BUILDINGS 17 & 18 UNIT E3A & �3B LOWER LEVEL PLAN � Job No.: 13-47 <br /> GLAZED. TERMINATE � <br /> AT NEWEL POSTS OR SAFETY TERMINAL � SEE U1$ FQR INTERI4R ELEVATIONS �/4"=�'-o" BUILDINGS 17 & 18 � Sheet No.: <br /> z <br /> PROVIDE 5/a" (MIN.) GYPSUM SHEATHING ON WHERE USED AS A GUARDRAIL, A MAX. OPENING OF AND INTERIC)R STAIR PLANS � U 7 ■ � <br /> WALLS BEHIND TUB/SHOWERS TO SATISFY FIRE 1 � <br /> REQUIREMENTS AT UNIT SEPARATION WALLS CONDlTION. 4��• ( <br /> Sheet Order: A B U F R E S D � <br /> T <br />