E3 UNIT VARIATIONS '
<br /> A - BASIC PORCH/ NO POPOUT AT REAR
<br /> B - BASIC PORCH/ POPOUT AT REAR .
<br /> C - ENHANCED PORCH/ NO POPOUT AT REAR
<br /> D - ENHANCED PORCH/ POPOUT AT REAR
<br /> SEE BUILDING PLANS FOR WHERE
<br /> ,
<br /> VARIATIONS OCCUR
<br /> � � � � � q � '� � +
<br /> ,
<br /> f � C C ;'�l � „� � t' $ 5 ;
<br /> INSULATION ' '
<br /> : �` � � ;
<br /> _ �� ��r�rr;�� w�y� s��t� 2t�1 .:
<br /> FOUNDATIQN RERIMETER - R-10 R(GID .
<br /> ������n�t1F�/t�s�ati�`��n� ��4�33'
<br /> INSULATION TO A DEPTH OF 24" OR TO TOP
<br /> �,`������.�:�'�,�f� �"�2�b�8 ����
<br /> OF FOOTING AT HEATED PERIMETER ' `
<br /> . �Jfe1�.�<������r+���#���`e� r�rxr
<br /> WALLS: 2x6 WALLS WITH FIBERGLASS BATTS
<br /> ;
<br /> OR BLANKETS - R21
<br /> FLOORS OVER UNHEATED SPACES - R-30
<br /> 5052 REGISTERED ,
<br /> ATTICS AT TRUSSES - R-49 �
<br /> (R-38 SHALL BE DEEMED TO SATISFY THE ARCHITECT
<br /> REQUIREMENT OF R-49 WHEREVER THE FULL �
<br /> HEIGHT OF UNCOMPRESSED INSULATION EXTENDS
<br /> OVER THE WALL TOP PLATE AT THE EAVES)
<br /> ROBERT E. WEIBLE
<br /> STATE OF WASHINGTON `
<br /> EXTERIOR DOORS: DOORS BETWEEN HEATED
<br /> AND UNHEATEQ SPACES SHALL BE U=0.30 � �
<br /> OR BETTER
<br /> WINDOWS: ALL WINDOWS AND SGD TO HAVE
<br /> �
<br /> �
<br /> 7
<br /> U-FACTOR QF U=0.30 OR BETTER
<br /> �
<br /> N
<br /> INSULATE UNDER STAIRS AND IN WALL
<br /> I �
<br /> CAVITIES ABOVE BOTTOM QF STRINGERS '
<br /> �
<br /> �
<br /> �
<br /> .�
<br /> a
<br /> GYPSUM WALLBOARD SCHEDULE
<br /> �
<br /> a
<br /> u
<br /> %a" GYPSUM WALLBOARD (GWB) SHALL BE �
<br /> USED THROUGHOUT ON INTERIOR WALLS,
<br /> INTERIOR SIDE OF EXTERIOR WALLS AND �
<br /> CEILINGS EXCEPT AT EXTERIOR WALL.S AND � �
<br /> s
<br /> COMMON WALLS REQUIRED TO HAVE A 9-HR
<br /> a
<br /> OR 2-HR FIRE-RESISTANCE RATING IN
<br /> �
<br /> WHICH CASE 5/8" TYPE 'X' GWB SHALL BE '
<br /> a
<br /> USED.
<br /> �
<br /> �
<br /> a
<br /> �
<br /> �
<br /> � � �
<br /> a .�
<br /> I � �
<br /> �
<br /> � �
<br /> i o V
<br /> Z o
<br /> �
<br /> � M � �
<br /> W � �
<br /> � N
<br /> m ,
<br /> c �
<br /> � � �
<br /> , �
<br /> M �°
<br /> �
<br /> ,
<br /> W z � �
<br /> c N
<br /> o �
<br /> Q �
<br /> n �
<br /> W a
<br /> M �
<br /> W °o m �
<br /> n � 3 �
<br /> Q � � �
<br /> M
<br /> W
<br /> � o
<br /> �, � �
<br /> .� a u
<br /> � �
<br /> �
<br /> �
<br /> j I� � j � i i( ( ABO WALLS, BEAM��S, ANDUPOST9 �
<br /> it� N N Z � i i ii � i i WITHIN GARAGE.
<br /> g " . I � ��-__ � ' �, Carage
<br /> c� ¢ ; 1 � � � 16 -� � I �
<br /> � � :. . i , ; i �� D3 SIM. j 4�-'" 5-�� 9-9yZ� � °' �
<br /> � ? . . . i � � � � , �
<br /> � Q ----. :. . . . . . . . . . . .�-.-. .------ , o L ---;�.
<br /> • �n.-._�. n
<br /> � ........ .......................................
<br /> . �w . . .':�,,j.'. . . . . . . . . . . . . . . . . . ..'.'. . '---- -- � �I � -------- - --'�"�'�'�'�'�'�'� - ------- ------- ---- �
<br /> 1 INSULATE SOFFlT AROUND�BEAM `
<br /> N O T E S � : -- ---- --------"--------------� � -—- __ I � UNDER AND BATH EXHAUST � /1
<br /> � `- 10 ��2 ^ OFFIT 16 OFF CEILING z, S,> � �STAIRS 8 �, _
<br /> FRAMING: 2x6's AT EXTERIOR WALLS THE FIREPLACE SHALL BE LISTED BY UL OR FM AND ---- � N � �`
<br /> -�I- D5 P n (� "� �j � I I �� � �
<br /> � �, � 2 i CONTINUE COMMON WALL
<br /> SHALL BE INSTALLED IN ACCORDANCE WITH THAT � 2 � 1� � � �
<br /> 2x4's AT INTERIOR WALLS �
<br /> UNLESS NOTED OTHERWISE. LfSTWG i ¢ D1 D5 "' GWB THROUGH FURRING �
<br /> � • �j .... ... ... uP pz 9 3 i
<br /> SE� S1.1 FOR STUD SCHEDULE. • TYPICAL 1� � 5 ' - ' O
<br /> E W A T E R R E S�S T A N T G Y P S U M W A�L B O A R Q SIM. �
<br /> :
<br /> ; . . �. . . . . . . . _ D5 —
<br /> PRavi� ' � ♦
<br /> •••••••••••••••••• R-21 BATT INSULATION BEHIND TUB AND SHOWER ENCLOSURE MATERIALS � = j� � siM. � �� • , �
<br /> � � � ' � t a c� .... •��.. .�..� , � Q +�+ V
<br /> . ------ 3�/2" ACOUST. INSUL. EACN SIDE TO A HEIGHT OF 70" MINIMUM ABOVE THE t. . . . . . . SOFFIT C�? DICI,/Fam. � � °t � o. 3� � 0 3 �°��'' � �s '� /�+ �
<br /> OF PARTY WALL, UNO. DRAIN WLET. . 7 -10 A.F.F. � , �� _
<br /> � » ' �° LOW WALL AT . ��� _ �� a Bath � N l D3 � W � �
<br /> 0 o i � � ,r, SIM. 'L�, V/
<br /> N � I f18" ABOYE : o N 1 24'Te � �
<br /> � Pw�r . � a�
<br /> I x � ^ ^ NOSING. RAI�ING � a a i
<br /> CONCEALED SPACES SHALL BE F(RESTOPPED IN BOTH NO PLUMBING, MECHANICAL EQUIPMENT, DUCTS OR � ; 24"'TB � � ABOVE 70+36p i o O N �
<br /> DIRECTIONS AT 10'-0" ON CENTER ANQ AT FLOORS. VENTS SNALL BE LOCATED IN TNE COMMON UNfT INSULATE FLOOR OVER ;
<br /> • ° 2-6 HC i 2 LOCATE PI �
<br /> TYPICAL. SEPARATION WALLS PER IRC SEG R302.2 (EXCEPTION) . . UNHEATED SPACE j s p, ROUGH-IN �
<br /> z � UP D5 I � FOR (2) L � � S
<br /> 7P. . , . .'. � 4- AT COMMC
<br /> ; : � . . .
<br /> -� _ � � �
<br /> ALL ESCAPE OR RESCtJE WINDOWS FROM SLEEPING ALL BEDROOM AND BATHRQOM DOORS SHALL BE ••••••••-• •••••••••••••••••�•••• ••••••••••••� _� 3 Entry 2, 6, 2._oy.� ,._3y. a,; L
<br /> 3 „ 1-6 ,2-6 F � 7-0 5-� DBL SL � 'o °' ���: � � � � L Q
<br /> ROOMS SHALL HAVE A MiNIMUM NET CLEAR OPENING UNDERCUT A MINIMUM OF /4 ABOVE THE ADJACENT � '
<br /> OF 5.7 SQUARE FEET. TNE MlNIMUM CLEAR OPENING FLOOR COVERING. �° AT 6'-9 " ABOV : AT 8'-0" A.F.F. '
<br /> ......: N " � .. ,.. Bedroom 3 � � � 0 G� Z
<br /> HEIGH7 DIMENSION SHALL BE 24". THE MINIMllM CLEAR AN G �••••••
<br /> QPENING WIDTH DIMENSION SHALL BE 20". SILL THE FRONT DOOR SHALL BE OPENABLE FROM THE --� ( L---� ' • � 8 ~ W =
<br /> � � y. y24 e � o,
<br /> HEIGHT SHALL BE NOT MORE THAN 44" ABOVE THE INSIDE WITHOUT THE USE aF A KEY OR ANY SPECIAL � 2•-3 2�-3
<br /> I N � � m O
<br /> FLOOR PER 1RC SEC. R310.1.1. KNOWLEDGE OR EF�ORT. IT MAY BE PROVIDED WITH A �
<br /> � � � ( POrC�I I � s-o�s� � �
<br /> NIGHT LATCH, DEAD BOLT OR SECURfTY CHAIN, '
<br /> I � � • A7 6'-8'AF.F. �
<br /> WNERE SILL AT OPERABLE WINDOW IS LOCATED MORE PRQV(DED SUCH DEVICES ARE QPENABLE FROM THE � ����� ���������� ��
<br /> THAN 72 INCHES ABOVE FINISHED GRADE OR OTHER INSIDE WITHOUT THE USE OF A KEY OR TOOL, AND � ' „s�-s3/4- z�_e� o ------ �� _ �
<br /> �
<br /> M � � �_ t � Dt 0
<br /> SURFACE BELOW, SILL NEIGHT SHALL BE MINIMUM 24 MOUNTED NOT TO EXGEED 48" ABOVE THE F(NISHED ' ' � ' � � � - �� �` �
<br /> 2-9' 2 -4" 5 -0" 5 -0' i i � oz � � a
<br /> INCHES ABOVE FINISHED FLOOR. PER IRC SEC. 312.2.1. FLOOR. -- ---
<br /> 5'_�" 2'-p" 10�-0" 2'-0" '- � � � �
<br /> � �'-�Ys"
<br /> �2 uP l�'
<br /> ALL GLAZING SHALL CONFORM TQ (RC SEC. R308.4, STAfR NOTES: 19'-1"
<br /> HAZARDOUS LOCATIONS. GLAZING IN ALL DOORS SHALL LOCATE HANDRAILS AT 34'-38" ABOVE THE os 5 9�
<br /> r-�Ys r-�+Y4 �
<br /> BE SAFETY GLAZED. ALL GLAZING WITHiN A 24" ARC STAIR NOSING.
<br /> OF EITHER VERTICAL DOOR EDGE SHALL BE SAFETY U N IT E3A & E3 B MIDQLE LEVEL PLAN
<br /> GLAZED. ALL GLAZING WITHIN 60" OF A HAZARDOUS HANDRA(L GRASP DIMENSION SHALL BE BETWEEN 1" & �
<br /> LOCAT(ON, OR "WET SURFACE" SHALL BE SAFETY 1-1/4". PROVIDE CONTINUOUS HANDRAIL OR 1�4"=1'-0" BUILDINGS 17 & 18 UNIT E3A & �3B LOWER LEVEL PLAN � Job No.: 13-47
<br /> GLAZED. TERMINATE �
<br /> AT NEWEL POSTS OR SAFETY TERMINAL � SEE U1$ FQR INTERI4R ELEVATIONS �/4"=�'-o" BUILDINGS 17 & 18 � Sheet No.:
<br /> z
<br /> PROVIDE 5/a" (MIN.) GYPSUM SHEATHING ON WHERE USED AS A GUARDRAIL, A MAX. OPENING OF AND INTERIC)R STAIR PLANS � U 7 ■ �
<br /> WALLS BEHIND TUB/SHOWERS TO SATISFY FIRE 1 �
<br /> REQUIREMENTS AT UNIT SEPARATION WALLS CONDlTION. 4��• (
<br /> Sheet Order: A B U F R E S D �