T
<br /> SIDING - SEE ELEVATIONS 5
<br /> � FOR TYPE
<br /> , ii W.R.B. (TYP.) UNIT ii�/i�i 1" D1
<br /> UNIT �i��i�if�i �i/
<br /> ' SEE DETAILS 8/11 AND 3/a T&G PLYWOOD SUBFLOOR UNIT 2 2 ^
<br /> � OVER 2X FLOOR FRAMING �
<br /> �`� 17/11 FOR INSTALLATlON 1Ya" FLOOR SHEATH(NG
<br /> � ; � Q 96" O.G. U.N.O.
<br /> „ �
<br /> 2 X 12 STRINGERS � � � � � 4�
<br /> ' ' � �
<br /> i z xi iii/i�ii /r ii �
<br /> NEADER PER � �-� ; , � �
<br /> STRtJCTURAL ' ; l "�+- � SLOPE 2 2 2 AT 12 O.C. i�f����ii�ii� i�ii � f �'!
<br /> ; , , \ >
<br /> ; 10° MIN. 1X8 GARAGE T �o io � .
<br /> � 1Ya" FLOOR SHEATNlNG
<br /> 1x8. . ... .. .: .... ... .. .. . . .:.:.
<br /> � � 2x12 STRINGERS � � '�: � � �' � � ;
<br /> - ;_� i � /�����/ �� PROVIDE R-30 INSUL. AT 12" O.C. _ �} '
<br /> GWB � QVER UNHEATED R-30 INSUL. � � � " � '"`� � � � S', °
<br /> ' 2 SPACES PROVID N
<br /> ,_ � _ ; 24 GAUGE PPM FLASI-fING ' !i��i��iri ri�i!�i NEATED � ��: � F
<br /> � . . .: ., .. ... SEE UNIT STAIR 2 OV R U „ f > .
<br /> � � PROVIDE SEALANT END DAMS .. .:: ..... . ..: . :_,._., ,. : .... . : : .....: �::...,..... . :..:...>. .. .. ..` .. ..; : -. _.. :..:�.. .`...... . ., SPAGES. �5 �e�tr�1�la�. St�tt���Q "
<br /> - � � PLANS FOR RISER �
<br /> , AT EACN END
<br /> � AND TREAD s 4 : (1) LAYER �� R��r�(p�t(, Wa�ixs�t���� ����� "
<br /> � �� 5/a EXTERIOR TRIM (TYP.) DIMENSIONS. 2 6 5/a" TYPE X GWB ��,�4�5 4�4����3 � 4��k�$�1;�06�:
<br /> � ----- i-� � SEE ELEV. FQR WIQTH (1) LAYER 5/a" GWB (1) LAYER , ; :
<br /> , . , ;: (5/s" TYPE 'X� GWB WITH UNfT z ' S/s" GWB �
<br /> �l�� ��r� rr�r��r��������I�x�or�� :
<br /> SEALANT i �SEALANT AND BACKER ROD R-30 INSULATION WHEN R-2 1 I N S U L.
<br /> PROVIDE 2x8 BLOCKING PER MFR INSTALLATION OVER GARAG�)
<br /> (FOR DRAPERY) EACH SIDE REQUIREMENTS SEE UNfT STAIR 50�2 REGISTERED
<br /> OF HEAD AT ALl� BEDROOM VINYL SLIDING GLASS DOOR
<br /> AND GREAT ROOM WINDOWS PLANS FOR RISER ARCHITECT
<br /> AND TREAD
<br /> (TYP.) �
<br /> DIMENSIONS.
<br /> PATIC� �OC�R HEAD INTERMEDIATE STAIR LANDINC STAIR DETAII AT CARAGE �OP OF ST�I� DE��IL ROBERT E. WEIBLE
<br /> 1� � � � STATE OF WASHINGTON
<br /> 3" _ �'-o" SECTION � �/2" _ �'-o" SE+�TION 1 1/2" _ �'-o" SECTION 1 �/�" _ �'-o" SECTION
<br /> �" T T -�
<br /> - I _� �
<br /> � �
<br /> � ;.' � y ��� �
<br /> PROVIDE BLOCK(NG FOR
<br /> � � D� j ijfi///�ji�'jiij 1Y8„ FLOQR �i// f/i/�if/ii/x V''
<br /> TRtM AND SlD1NG �:FIN. FL_�_ i 2 6 ? 1Ya" �LOOR SNEATHING T � 1 1Y8" FLOOR � � SHEATHING �
<br /> GWB ( � � � , SNEATNING ,�
<br /> � 2x12 STRWGERS � 1" 1"
<br /> 2 2 � '. AT 12" 0.C. ' �i�i��il�iif 1�i �;
<br /> SEALANT ; � ' i!if�iir�,ii�ii;i. 2 X 12 STRINGERS 2x12 STRIN�ERS i ii�i/�i!�i��ii�� �-'
<br /> ; EXTERIOR ; �- 9 x8 PROVIDE R-30 '
<br /> , AT 12" O.C. AT 12" O.C. �
<br /> ; PROVlDE R-30 INSUL. 9 INSUL. OVER 1X8. 7x8 �
<br /> � 10 OVER UNHEATED D5 UNHEATED -�
<br /> SLOPE � SPACES. 2Q A � PROVIDE R-3D INSI. �
<br /> , `.... . .. .... ........- .:._ ,
<br /> , i -�___ 10° M1N. _ I 2 s SPACES. 2x12 P.T. 2x BLOCKING
<br /> � � 1 LAYER 5/a" GWB ` , _ OVER UNHEATED �
<br /> � 6 6 — ' ' Z 6 °' S/a" TYPE 'X' GWB � . 2 2, � � BOTTOM PLATE SPACES. �-
<br /> �
<br /> , _ ' G RAGE e . a d a a a � �
<br /> _ _ �- : . ; �. .
<br /> . , 'p . � . . � �Q
<br /> . . . . .. . . . � � d � 4 ' '
<br /> _
<br /> _____________ _ ____�___��___________ __:`___ ,.�' ' " .Q . LS Q . ..A . . d . q� ',4. ' d.� : ' � 4. .. , . Q � � ,h,� � .
<br /> _ _ ___ ___ _ __ � 1 LAYER
<br /> HEAD I '' a a a a a. . d o 518�� G�� �
<br /> SlDING, SEE ELEV. FLASHWG :' (1) LAYER ! �
<br /> FOR TYPE SHlM, PER DOOR ��- 5/s" TYPE X GWB ° � BEAM PER STRUCTURAL �
<br /> ,
<br /> SEALANT PER SlDWG MFRS REQUIREMENTS � ; Y�" GWB (MIN.) AT GARAGE 10' t0 I ( —) I � I ° � s
<br /> : _ � . . . _-1 I I�II I —I1 I I-111=1 I =1 I =i I =) I 1=k1 I 1=1 I ��I I I` I I 1=I Q a .�'
<br /> M F R I N S T A L L A T I O N SEALANT AND BACKER ROD 2x10 TRIM � —I I (—I I I—I I (=I f �=I I (=I ( I=I ( I=I I (—I ( �=1 ( I=I I I=I ( I=1 (=I f I, �-
<br /> _.. .. . .... , . ....._ . . . . .... . . ....... . r; �
<br /> PER DOOR MFR INSTALLATION -
<br /> R E Q U f R E M E N T S �{i—�i i—1 I (—) ( 1—.1 I I—) I I_=� � I—I I (— �—
<br /> FLASHING SYSTFM REQUIREMENTS -I I {—I I I—) � �—I I I=, �� I I, -I I I=' � O
<br /> SEE C?ETAILS 8/11 $/a X 5%Z E X T E R I O R T R I M (T Y P.) H E A D E R P E R SEE UNIT STAIR SEE UNIT STAIR SEE UNIT STAIR
<br /> AND 17/11 SEE ELFV. FOR WIDTH STRUCT. PLANS FOR RISER PLANS FOR RISER PLANS FOR RISER
<br /> ; �- AND TREAD AND TREAD ANQ TREAD
<br /> u � DIMENSIONS. DIMENSIONS. DIMENSIONS.
<br /> 2x HEAD TRIM � --- � �
<br /> SLIDIN� PATIO DOC�R )AMB TYP. CARAGE HEAQER BOTT4M �JF STAIR � LANDING BC�TT4M C�� STA1R � CQI�C. BC)TTOM OF STAI� � �
<br /> 18 14 10 6 2 0 �
<br /> 3°° _ �j-o°° PLAN 1-1/2°° _ ,�-o�� SECTION � ,�z�° _ �°-o�� SECTION � �/2�� _ ��-o�� SECTION � �/2°° _ ��-o°� SECTION �
<br /> 1" T
<br /> 'NTER'°R ; ��TER►°R � INSllLATICJI� AND ENEf��Y NC�TES .. �
<br /> �, SIDING - SEE ELEVATIONS RIPPED 2x8 FRAMING � r ii'�'i''��ii�i%� � � � o
<br /> . ..._�°". ;I FOR TYPE " 1Ys" �L,OOR a c�
<br /> �. 2` 6 ;� W,R.B. (TYP.) 16 o.c. FQR LANDING ��Q�jpn - �e��C� DOO�S s O `� �
<br /> SEE STAIR PLANS FOR SHEATHING
<br /> � ' � LANDtNG HE►GNT `� 2x12 STRING�RS 1x8 All insulation materials shall be installed according to the manufacturer's All exterior doars or daors serving as access to an enclosed unheated �_ Q
<br /> � i SEE DETAILS 8/11 AND FOUNDA-f"lON OPENING >, �, instructions to achieve ro er densifies and maintain uniform R-values. area shall be weatherstripped to �imit leakage around their perimeter when in a �
<br /> 17/(1 FOR INSTALLATION �/z GWB (MIN.) AT 12 Q.C. p p ' �
<br /> SEE STRUCTURAL ; ; a Substantial contact of the insulation with the surTace being insulated is required. closed position. �.,
<br /> FOR HEADER SIZE ��� _ � OVERHEAD DOOR DOOR SIZE �
<br /> ' � ' S H E A T H I N G PROVIDE ��i�f���i��;���f�i%�i��;F ��i��r%�;��;��;%���';�� Where required, insulation shail be installed with clearances according to The thermal transfer characteristics of insulated daors shall be U-value 0.30 �
<br /> 1 I %4" MIN. GAP SYSTEM BLOCKING FOR ° manufacturer's specifications. Insulation shall be installed so tnat required or better per WSEC section R402.1.1. � L-
<br /> �� i � � � TRIM AND 51DING o o ventilation is unobstructed. For blown or poured loose fill insulation ciearances � �R't �
<br /> � � i � a"'' _
<br /> � �� shall be mainta�ned through installation of a permanent retainer. �
<br /> ' 2x BLOCKING ° ° � �
<br /> � , ; `�24 GAUGE PPM FLASHWG 2 2 2 (1) LAYER ��d�W�
<br /> I ° � ' S/8" GWB Glazing U-values for windows and SGD shall be U-value 0.30 or befter per �
<br /> , i FLASHfNG SYSTEM s s s HANGER PER � � �� WSEC section R402.1.1 as indicated on the unit plans.
<br /> 2X TRIM ________ STRUCTURAL R-10 slab on grade insulation shall be installed inside the foundation wall and Windows shall be furnished with outdoor air inlets as indicated on the Unit
<br /> '�� I ---- - ° snall extend down vertically 24" or to the top of the footing whichever is less Electrical plans. Inlets shall have a controllable and secure opening and be
<br /> , ; SEALANT PER MFR
<br /> ���- � INSTALLATION Y4 SIDWG SEE ELEV. ° BEAM PER STRUCTURAL per WSEC section R4022.9. capable of a total opening area of not (ess than four (4) square inches and
<br /> REQUfREMENTS FOR TYPE, {NSTALL PER � tested by a nationally recognized standard or approved agency and located � �
<br /> 5/a X 5Y EXTERIOR TR1M (TYP.) MFR REQUIREMENTS to avoid drafts. Inlets shall be screened or otherwise protected from entry by g ��
<br /> DOOR FRAME 5/4X5Yz EXTERIOR TRIM (TYP.) SEE �LEV. FOR WIDTN FLASHING SYSTEM � �'1Sl�C�t� �OOfS inseets, leaves, or o'rher material. "' j
<br /> - �� - ' 2x BLOCK(NG Floor insulation shall be installed in a ermanent manner in substantiai
<br /> SEE ELEV. FOR WIDTN SEE UNIT STAIR p
<br /> IN-SWINGING � SEALANT PER MFR AS NECESSARY PLANS FOR R(SER contact with the surface being insulated. Insulation supports shall be instailed so
<br /> DOOR SEALANT PER DOOR MFR INSTALLATION 5 AND TREAD spacing is no more than twenty-fiour inches on center. R�Of/C '
<br /> WSTALLATION REQUIREMENTS PER PLANS
<br /> i EXTERIOR REQUIREMENTS �� DIMENSIONS. Floors separating conditioned space from unconditioned space shall have a Roof/Ceiling insulation: Open-Blown or poured loose fill insulation may be
<br /> vapor barrier installed. Vapor barrier shall be installed on the warm side of the used in atfic spaces where the slope af the ceiling is more than 4 in 12 and �
<br /> EXT E R I C�R D�O R H EAD insuCation. The va or barrier shall have a one erm dr eu ratin or less (i.e. there is at least 44 inches of ciear distance fram the fo of the bottom chord
<br /> � �j GARAGE DCJOR �A►MB BOTTO►M LANDING @ STAIR four mil. polyethylene or krafT fiaced mafierial). phe floor sheafihing may be used of the truss or ceiling joist ta the underside of the sheatping. When eave vents �
<br /> 1� , "' „ �� ,> , „ as the vapor barrier if rated (and so stamped) at one perm (max.) Otherwise are installed, baffling of the vent openings shall be provided so as to deflect �
<br /> 3 = 1 -0 SECT��N 1-1/2 = 1 -0 P�N 1-1/2 = 1 -0 ���T�oN place vapor barrier on top of joists befiore placing sheathing. the incoming air above the surface afi the insulation. Baffles shall be rigid � a°+
<br /> material, resistant to wind driven moisture. When feasible, the baffies shall be � �
<br /> installed from the fop ofi the outside of the exterior wall, extending inward, to a o �
<br /> PROViDE B�oCKiNG FOR EX��I�Or Wt"�S point six inches vertically above the height of noncompressed insulation, and �
<br /> TRIM AND SIDING �� 2x8 FRAMING All wail insulation shall fill the en'rire cavity. Exterior wall cavities isolated twelve inches vertically above laose fill insulation. Baffles shall be in place at � �
<br /> I I c� 16" o.c. �+ during framing shall be fully insulated to the levels of the surrounding walls. All the time ofi framing inspection. Q,? _
<br /> WTERIOR EXTERIOR TRlM AT C�
<br /> GARAGE DOOR JAMB faced insulation shal) be face stapled to avoid compression. Where the ventilation space abave the insulation is less than an average of W Q � �
<br /> � Walls separating conditioned space from unconditioned space shall have a twelve inches roof ceiling assemblies shall be provided with a vapor barrier g�
<br /> vapor barrier installed. Faced baft insulation shall be face stapled. Vapor having a 0.5 perm cup rating or less. Faced batt insulation wnere used as a � � � '�
<br /> � � SECTIONAL QVERHEAD �; STRUCTURAR ° �
<br /> ----- , barrier shall be installed on the warm side of the insulation. vapor barrier shall be face stapled. � � s �
<br /> 2 � ; o ; DOOR TRACK AT S1DES 2x BLOCKING ; ° Va or barriers shall not be re uired in roof/ceilin assemblies where the
<br /> r -� � OF OPENING f. p q g
<br /> ' �"--- ' ;: , � , ventilation space above the insulaTion averages twelve inches ar greater. � O � �
<br /> o � --�-- � � � �
<br /> EXTERIOR � � ��� Vapor barriers shall be installed on the warm side of the insulation.
<br /> N ' These air leakage notes apply to those locations separating outdoor � ,� L
<br /> FLASNING SYSTEM - ' ambient conditions from interior spaces that are heated or mechanically cooled. � � �? �
<br /> � 6 6 ' SEE DETAILS 8/11 SEE DETAIL 11/D2 � Exterior joints around windows and door frames, between walf cavities and �'8�QC9S � � � �
<br /> ; �� FOR GARAGE SLAB 5 ; � window or door frames, openings between walls and foundation, between walls Fireplaces shall be provided with each of the following:
<br /> AND 17/11 � �
<br /> ____ __ ___ _ ____ AND APRON ; and roof and wall panels openings at penetrations o� utility services through a) Tightly fitting flue dampers operated by a readily accessibfe manual or ~
<br /> D1
<br /> ' , walls, ffoors and roof; and all other openings in the building envelope shall be approved automatic control. � 0
<br /> SLOPE TOENAIL 2x6 C� 16' o.c. i �
<br /> SIDING, SEE E�EV. Q sealed, caulkec� gasketed, or weatherstripped fio {imit air lea�cage in a manner b) An outside source far combustion air ducted into the firebox. The duct �
<br /> FOR TYPE SNIM PER DOQR FOR CEILING FRAMING ' � �
<br /> BEAM PER � approved by the building official. shall be at least six square inches, and shall be provided with an
<br /> FLASNING SYSTEM MFRS REQUIREMENTS STRUCT RAL � operable outside air duct damper. ? Q
<br /> SEE DETAILS 8/11 SEALANT PER MFR � (1) LAYER c) Tightly fitting glass or metal doors, or flue draTt induction fan or as �' Q �
<br /> AND 17/11 fNSTALLATION p �/s" GWB approved by the Building Official for minimizing backdrafting. � �
<br /> SEALANT PER SfDWG
<br /> EXTERIOR REQUIREMENTS d) Include elbows for offsets ta framing as necessary. � r
<br /> — �
<br /> MFR INSTALLATION 5/aX 5Yz EXTERIOR � — ,— — _ . .. . . ..._. . �. . 2x BLOCKING �
<br /> REQUIREMENTS TRIM (TYP.) - SEE � ' 1— — — — �- �
<br /> _ PER PLANS -
<br /> ELEV. FQR WIDTH �
<br /> ��,
<br /> �
<br /> EXTERIt�R DOO� �AMB GARAGE DOCJR THRE�HC�LD �( RAISED FLOQR � STAIR �EILING __
<br /> '� 1ob No.: 13-47
<br /> 2 O �� 1� z Sheet No.:
<br /> 3" = 1'-0" P�.�1N 3" = 1'-0" SE�TION 1-1/2" = 1'-0" SEC��oN Q
<br /> � D �
<br /> �
<br /> Sheet Order: A � U F R E S D � �
<br /> r