My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2215 MERRILL CREEK PKY SPRINT ANTENNA 2018-06-07
>
Address Records
>
MERRILL CREEK PKY
>
2215
>
SPRINT ANTENNA
>
2215 MERRILL CREEK PKY SPRINT ANTENNA 2018-06-07
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/7/2018 2:58:02 PM
Creation date
6/7/2018 2:58:00 PM
Metadata
Fields
Template:
Address Document
Street Name
MERRILL CREEK PKY
Street Number
2215
Tenant Name
SPRINT ANTENNA
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
21
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• <br /> 'ANTENNA SECTOR II 'ANTENNA SECTOR 21 'ANTENNA SECTOR 31 <br /> S f)rent <br /> (P) 800MHz & (P) 800MHz & (P) 800MHz & <br /> 2.5GHz SPRINT 2.5GHz SPRINT 2.5GHz SPRINT <br /> ANTENNA ANTENNA ANTENNA <br /> Select Site <br /> Acquisition, LLC <br /> 870 ORAVETZ ROAD SE <br /> AUBURN,WA 98092 <br /> 1 i 1 <br /> Pi Office 206-790-4655 <br /> 1 1 i o PROJECT INFORMATION: <br /> i J ! J >r ❑ JI coII— <br /> _ — _ SEAWAY <br /> I <br /> � i AWG#10 � AWG 1_ Aw SE54XCOI9 SEAWAY <br /> 2215 MERRILL CREEK PKY <br /> EXIST.EGB�— - - ❑ - - - -� EXIST.EGe ❑ - - 9 - - - -0 ERIST.EGe ❑ _- _- -8-- - - <br /> i ❑ _ _ _ _ I _ I — - _ -11EVERETT, WA 98203 <br /> T #To AWG m #t0 AWG -20 1G AWG o'�T SNOHOMISH COUNTY <br /> 1 HYBRID CABLE INTERNAL I HYBRID CABLE INTERNAL I HYBRID CABLE INTERNAL <br /> " I GRD WIRE TO BE I GRD WIRE TO BE I GRD WIRE TO BE <br /> TRIMMED TO FIT AND I TRIMMED TO FR AND I TRIMMED TO FIT AND <br /> ATTACHED TO GRD BAR I I ATTACHED TO GRD BAR I I ATTACHED TO GRD BAR � I <br /> 1 1 I ISSUED DATE: <br /> I 05-23-17 <br /> LDC 1 FIBER �__ i DC/FIBER J ISSUED FOR: <br /> - - - _ (E) #2 AWG DC / FIBER <br /> BUILDING PERMIT <br /> _ _ _ _ _ _ _ _ �E)J2 AWG _ _ _ _ _ _(E)#2 AWG_ _ REVISIONS <br /> LEGEND REV. DATE DESCRIPTION INITIALS <br /> ■ EXOTHERMIC CONNECTION A 05-22-17 CD PRELIM DHD <br /> ❑ MECHANICAL CONNECTION B <br /> E`•algil o COMPRESSION CONNECTION <br /> C <br /> COB COLLECTOR GROUND BAR <br /> EXISTING UPPER TOWER— <br /> GROUND BAR MGB EXTERNAL GROUND BAR D <br /> I <br /> GROUNDING NOTES <br /> 1. ALL GROUNDING CONNECTIONS SHALL BE MADE BY EXOTHERMIC <br /> I WELDS. EXOTHERMIC WELDS SHALL INCLUDE ALL CABLE TO CABLE, <br /> I SPUCES, ETC. ALL CABLE TO GROUND RODS, GROUND RODS <br /> E.5 m SPUCES AND LIGHTING PROTECTIONS SYSTEM AS INDICATED. <br /> c� GROUND FOUNDATION ONLY AS INDICATED BY PM. ALL MATERIALS <br /> NEW <br /> BUSTING DEI EXISTING < USED (MOLDS, WELDING, METAL, TOOLS, ETC.) SHALL BE <br /> CABINET CABINET }rN, 8 8 MMES EXOTHERMIC WELDED AND INSTALLED PER MANUFACTURERS <br /> NET <br /> ANTENNA �' I.f _ CABINET HYBRID CABLE RECOMMENDATIONS AND PROCEDURES. GROUND CONDUCTOR SHALL <br /> — 1 <br /> INTERNAL GRD WIRE HAVE A MINIMUM 24" BENDING RADIUS. <br /> TO BE AND ATTACHED NOT FOR CONSTRUCTION UNLESS LABELED AS <br /> TO GRD BAR 2. ALL EXOTHERMIC WELD CONNECTIONS ON GALVANIZED SURFACES CONSTRUCTION SET <br /> #6 AWG WITH SHALL BE CLEANED THOROUGHLY AND COLORED TO MATCH <br /> WEATHERPROOFING ( SURFACE WITH (2) TWO COATS OF GALVITE (WHITE) PAINT. OR <br /> SILVERBRITE (ALUMINUM). <br /> - - - -(E)#2 AWG - I cern c�.n uI ) <br /> az ¢z 9z 3. ALL ELECTRICAL & MECHANICAL GROUND CONNECTIONS SHALL HAVE <br /> 7 n COAX oo� o0 o& ANTIOXIDANT COMPOUND APPLIED TO CONNECTION. 7473 REGISTERED <br /> -Ix 'aca •,.cel. <br /> EM`BS GND BAR 4 STANDARDGROUNDTESTS PROCEDURES. GROUNDSHALL BERMED GRID REST TANCEASDSHALL NOTT ARCHITECT <br /> BY <br /> 2 AWG -'Moe 'r-� <br /> EXCEED 5-OHMS. <br /> EXISTING LOWER 5. CONTRACTOR SHALL SUBMIT THE GROUND RESISTANCE TEXT , <br /> TOWER GROUND BAR REPORT AS FOLLOW: ir.- j <br /> I <br /> 1.ONE (1) COPY TO OWNER REPRESENTATIVE •'VI 1 H. r 'N <br /> I I I I 2.ONE (1) COPY TO ENGINEER STATE OF WASHINGTON <br /> I I I 3.ONE (1) COPY TO KEEP INSIDE EQUIPMENT INCLOSURE <br /> L5 NEW <br /> I 6. ALL RADIO EQUIPMENT AND UTIUTY CABINETS GROUNDS LEADS TO <br /> z C BINET BE #2 AWG STRANDED GREEN JACKETED FROM BUSS TERMINAL <br /> Eg I #2 AWG 7. FOR ADDITIONAL GROUNDING NOTES SEE N-1 OR N-2. <br /> SHEET TITLE: <br /> 8. ALL ANTENNA MOUNT mGREEN JACKETED CABEGRGROUNDS OUNDS HSHALALL L EBE2BLACK 2 AWG SFROM OMFR . GROUNDING DETAILS <br /> z #2 AWG <br /> �-'I <br /> �S CI9. ALL GROUND WIRES FROM GROUND BARS TO GROUND SHALL BE <br /> #2 AWG SOLID BARE AS REQUIRED. <br /> EXISTING 0 AG EXISTING#2 AG 10. ALL ABOVE GROUND WIRES SHALL BE GREEN JACKETED. ALL SHEET NUMBER: REVISION: <br /> GROUNDS TO EXISTING — — ►�� GROUNDS TO EXISTING SOUDNDD WIRE'S PENETRATING INTO GROUND AND BELOW SHALL BE <br /> GROUND RING - GROUND RING ?"" <br /> 22'x34"SCALE: NOT TO SCALE G-2 (7-' <br /> 7LGROUNDING RISER DL�GRr'v�� 4 OHO PROJ. NO. <br /> 11"x17`SCALE: NOT TO SCALE 2017-OS7THE INFORMATWN CONTAINED IN THIS SET OF CONSTRUCTION DOCUMENTS IS PROPRIETARY BY NATURE. ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO SPRINT CARRIER SERVICES IS STRICLY PROHIBRED. """.:".". <br />
The URL can be used to link to this page
Your browser does not support the video tag.