My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2215 MERRILL CREEK PKY VERIZON WIRELESS ANTENNA 2018-06-07
>
Address Records
>
MERRILL CREEK PKY
>
2215
>
VERIZON WIRELESS ANTENNA
>
2215 MERRILL CREEK PKY VERIZON WIRELESS ANTENNA 2018-06-07
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/7/2018 3:47:34 PM
Creation date
6/7/2018 3:47:28 PM
Metadata
Fields
Template:
Address Document
Street Name
MERRILL CREEK PKY
Street Number
2215
Tenant Name
VERIZON WIRELESS ANTENNA
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
57
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
NOTES <br /> GENERAL NOTES: 0© 1. INSERT SCISSORBRACKETS BETWEEN THE RRUS NOTE: <br /> UPPER ANTENNNAA MOUNTING BRACKET AND THE 1. RRUS MOUNTED NEAR ANTENNAS. <br /> •1. THE CONTRACTOR SHALL COMPLY WITH ALL LOCAL AND NATIONAL CODES, UPPER POLE ADAPTER BRACKET.SECURE USING 2. CONTRACTOR TO VERIFY WITH <br /> 0 O 0 ' 112 INCH HARDWARE PROVIDED. MANUFACTURER SPEC's FOR <br /> REGULATIONS AND SAFETY REGULATIONS,ALL OSHA REGULATIONS,ALL PUBLIC 2. TO SET THE DEGREE OF DOWNTILT,ALIGN THE POLE MOUNTED i MOUNTING DETAILS. ism <br /> AND MUNICIPAL AUTHORITIES,AND ANY UTILITY COMPANIES'REGULATIONS AND 0 4. ''`. DESIRED HOLES ON THE SCISSOR BRACKETS RRU 3. RRUS DETAIL AS SHOWN AS A <br /> DIRECTIVES. ¢�" * AND SECURE USING 5/16 INCH HARDWARE d REFERENCE AND IS SUBJECT TO <br /> ..''` © PROVIDED. ,� CHANGE. - O <br /> 2. THE DRAWINGS AND SPECIFICATIONS ARE A GENERAL DIRECTIVE FOR THE �1. �\1 3. THE NUMBER OF CONNECTORS WILL VARY PIPE MOUNT I' 4, PLATFORM SHOWN AS TYPICAL. .. <br /> SCOPE OF WORK.EXACT DIMENSIONS AND LOCATIONS MAY CHANGE IN THE FIELD. `��Cy' 1- BASED ON ANTENNA TYPE. ADAPTER VERIFY ACTUAL CONDITIONS IN FIELD. <br /> THE CONTRACTOR IS TO VERIFY THE DIMENSIONS AND LOCATIONS AND REPORT TOP <br /> ANY AND ALL A." " NOTE: <br /> DISCREPANCIES TO REPRESENTATIVE.ANY MINOR ERRORS AND OMISSIONS IN THE 0 OPTIONAL DOWNTILT BRACKET ti RRUS CAN ONLY BE PAINTED ON SUNSCREEN <br /> DRAWINGS AND SPECIFICATIONS DOES NOT EXCUSE THE CONTRACTOR FROM �� <br /> 12.04" 7.008" <br /> COMPLETING THE PROJECT AND IMPROVEMENTS IN ACCORDANCE WITH THE PIPE MOUNT(TYP) <br /> INTENT OF THESE DOCUMENTS. \ MFR'S STANDARD • <br /> VALMONT MICROFLECT PART#131001 MOUNTING PIPE I I1 MOUNTING �� <br /> OR APPROVED EQUAL 'I <br /> 3. CONTRACTOR IS RESPONSIBLE FOR FIELD MEASUREMENTS TO CONFIRM (TYP) BRACKETS <br /> (id, <br /> LENGTHS OF CABLE TRAYS AND ELECTRICAL LINES AND ANTENNA MOUNTING. PARTS: r ' <br /> 4. VERIFICATION THAT EXISTING TOWER/POLE CAN SUPPORT THE PROPOSEDIii © ITEM QTY DESCRIPTION 17C <br /> 7ANTENNA,COAX&ADDITIONAL EQUIPMENT LOADING IS TO BE DONE BY OTHERS. t 0 1 ADAPTER,POLE,LOWER (_y :�' <br /> 1'`0 ! © 1 BRACKET,DOWNTILT,POLE iv cs <br /> O 0 0 1 BRACKET,DOWNTILT,ANTENNA RRUS III t-- N <br /> I <br /> 0 6 1/2 X 1 HEX HEAD BOLT <br /> PANEL 0 6 1/2 SPLIT WASHER <br /> 0 ANTENNA 0 2 5/16 X I HEX HEAD BOLT ISOMETRIC VIEW <br /> O (TYP) © 2 5/16 SPLIT WASHER NH) JI4 SITE SOLUTIONS <br /> RRU WITH ill <br /> 1 i tto8a7MwN SeIMoH <br /> Q 8 UT 1/2'SPLIT <br /> DED RODWASHER N. .. .. SUNSHIELD <br /> 0 8 1/2"SPLIT WASHER \ I —' —— I 't <br /> .11 <br /> 1 12 1/2"NUT FRONT SIDE <br /> 1 GENERAL NOTES 2 ANTENNA MOUNTING HARDWARE RRUS 32 MOUNTING DETAIL <br /> NOT TO SCALE WAVE <br /> RRUS NOTE: DIPLEXER NOTE: R G H I T E C T(J R E <br /> 1. DIPLEXERS MOUNTED AT ANTENNAS. <br /> 1. RRUS MOUNTED NEAR ANTENNAS. 2. CONTRACTOR TO VERIFY WITH <br /> 2. CONTRACTOR TO VERIFY WITH III <br /> MANUFACTURER SPEC's FOR MOUNTING 1133 184TH STREET SW <br /> MANUFACTURER SPECS FOR CHANNELS MOUNTEDDETAILS. SUITE 202 <br /> MOUNTING DETAILS. ■ ON ICE BRIDGE POST 3. DIPLEXER DETAIL AS SHOWN AS A LYNNWOOD,WA 88087 <br /> 3. RRUS DETAIL AS SHOWN ASA OFFICE:(425)7783800 <br /> '� REFERENCE AND IS SUBJECT TOPOLE MOUNTED - HEFERENSOND SUBJECT TO CHANGE.RRU " r 4. H•FRAME SHH OWN A AS TYPICAL.VERIFY JAY@NEWWAVEARCH.COM <br /> CHANGE. DIPLEXER ACTUAL CONDITIONS IN FIELD. <br /> 4. VERIFY ACTUAL CONDITIONS IN FIELD. <br /> ADAPTER11 <br /> PIPE 0 �! NOTE: / = DATE 4-21-17 <br /> " RRUS CAN ONLY BE PAINTED ON SUNSCREEN TOP ,. PREPARED BY. YML <br /> �I DIPLEXER MOUNTING <br /> .. gl <br /> VIC <br /> �, PLATE APPROVED BY JYS <br /> MOUNTING PIPE Os 5 18.5" MFR'S STANDARD 7.5" I <br /> (TYP) —O MOUNTING • ` <br /> r f�� BRACKETS �- \ .i 'i SUBMITTALS <br /> l7� .(e, r-mil- 1r ,$` .; NO DATE DESORPTION <br /> Nix� ..- <br /> 1.0._ <br /> i 77 <br /> �i jt <br /> 1Ijl <br /> RRUS , N S� II <br /> � r? <br /> 5 i 0, ■ REFER TO DETAIL-A (lei �IL7 <br /> ISOMETRIC VIEW = ONNE <br /> C <br /> _ <br /> . CONNECTION DIPLEXER <br /> r RRU WITH TO ANTENNA 4-21-17 FINAL PERMIT <br /> "-U SUNSHIELD MOUNT 4-3-17 REVISED PERMIT <br /> FRONT SIDE DETAIL-A <br /> 3-17-17 PRELIMINARY PERMIT <br /> 4 RRUS B5 MOUNTING DETAIL DIPLEXER MOUNTING DETAILS <br /> NOT TO SCALE 5 NOT TO SCALE REGISTERED <br /> HITECT <br /> " <br /> CABLE BLOCK HARDWARE KIT <br /> !���' 4.21-17 <br /> (SITE PRO#CH50(SINGLE <br /> AY Y. <br /> STACK),#CH80(DOUBLE STACK) STA OF WASHINGTON <br /> OR#CH05(TRIPLE STACK)) <br /> SEE PLAN FOR QUANTITY <br /> CABLE BLOCK <br /> (SITE PRO#CXB758 ORSITE <br /> APPROVED EQUAL) <br /> UNIVERSAL 01; <br /> ROUND-MEMBER SUPPORT <br /> �P .5 5 <br /> BRACKETSING WITH <br /> I HUTS .40.0 ...._ SIS SEA - FLUKE <br /> 4'-0"O.C.MAX. 1D) <br /> MFR.BY SITE PRO 1,#MS6. \ 2215 <br /> EXISTING MONOPOLE MERRLL CREEK PARKWAY <br /> TOWER EYERETT,WA$8203 <br /> rj:ICCI 0 .,, SHEET TITLE <br /> 9°0 r'' <br /> �,, 3-D OF SUPPORT DETAILS <br /> BRACKET-MS6. <br /> 6 ANTENNA CABLE ROUTING DETAIL SHEET NUMBER (k7/./9\. <br /> NOT TO SCALE A-4 <br />
The URL can be used to link to this page
Your browser does not support the video tag.