NOTES <br /> GENERAL NOTES: 0© 1. INSERT SCISSORBRACKETS BETWEEN THE RRUS NOTE: <br /> UPPER ANTENNNAA MOUNTING BRACKET AND THE 1. RRUS MOUNTED NEAR ANTENNAS. <br /> •1. THE CONTRACTOR SHALL COMPLY WITH ALL LOCAL AND NATIONAL CODES, UPPER POLE ADAPTER BRACKET.SECURE USING 2. CONTRACTOR TO VERIFY WITH <br /> 0 O 0 ' 112 INCH HARDWARE PROVIDED. MANUFACTURER SPEC's FOR <br /> REGULATIONS AND SAFETY REGULATIONS,ALL OSHA REGULATIONS,ALL PUBLIC 2. TO SET THE DEGREE OF DOWNTILT,ALIGN THE POLE MOUNTED i MOUNTING DETAILS. ism <br /> AND MUNICIPAL AUTHORITIES,AND ANY UTILITY COMPANIES'REGULATIONS AND 0 4. ''`. DESIRED HOLES ON THE SCISSOR BRACKETS RRU 3. RRUS DETAIL AS SHOWN AS A <br /> DIRECTIVES. ¢�" * AND SECURE USING 5/16 INCH HARDWARE d REFERENCE AND IS SUBJECT TO <br /> ..''` © PROVIDED. ,� CHANGE. - O <br /> 2. THE DRAWINGS AND SPECIFICATIONS ARE A GENERAL DIRECTIVE FOR THE �1. �\1 3. THE NUMBER OF CONNECTORS WILL VARY PIPE MOUNT I' 4, PLATFORM SHOWN AS TYPICAL. .. <br /> SCOPE OF WORK.EXACT DIMENSIONS AND LOCATIONS MAY CHANGE IN THE FIELD. `��Cy' 1- BASED ON ANTENNA TYPE. ADAPTER VERIFY ACTUAL CONDITIONS IN FIELD. <br /> THE CONTRACTOR IS TO VERIFY THE DIMENSIONS AND LOCATIONS AND REPORT TOP <br /> ANY AND ALL A." " NOTE: <br /> DISCREPANCIES TO REPRESENTATIVE.ANY MINOR ERRORS AND OMISSIONS IN THE 0 OPTIONAL DOWNTILT BRACKET ti RRUS CAN ONLY BE PAINTED ON SUNSCREEN <br /> DRAWINGS AND SPECIFICATIONS DOES NOT EXCUSE THE CONTRACTOR FROM �� <br /> 12.04" 7.008" <br /> COMPLETING THE PROJECT AND IMPROVEMENTS IN ACCORDANCE WITH THE PIPE MOUNT(TYP) <br /> INTENT OF THESE DOCUMENTS. \ MFR'S STANDARD • <br /> VALMONT MICROFLECT PART#131001 MOUNTING PIPE I I1 MOUNTING �� <br /> OR APPROVED EQUAL 'I <br /> 3. CONTRACTOR IS RESPONSIBLE FOR FIELD MEASUREMENTS TO CONFIRM (TYP) BRACKETS <br /> (id, <br /> LENGTHS OF CABLE TRAYS AND ELECTRICAL LINES AND ANTENNA MOUNTING. PARTS: r ' <br /> 4. VERIFICATION THAT EXISTING TOWER/POLE CAN SUPPORT THE PROPOSEDIii © ITEM QTY DESCRIPTION 17C <br /> 7ANTENNA,COAX&ADDITIONAL EQUIPMENT LOADING IS TO BE DONE BY OTHERS. t 0 1 ADAPTER,POLE,LOWER (_y :�' <br /> 1'`0 ! © 1 BRACKET,DOWNTILT,POLE iv cs <br /> O 0 0 1 BRACKET,DOWNTILT,ANTENNA RRUS III t-- N <br /> I <br /> 0 6 1/2 X 1 HEX HEAD BOLT <br /> PANEL 0 6 1/2 SPLIT WASHER <br /> 0 ANTENNA 0 2 5/16 X I HEX HEAD BOLT ISOMETRIC VIEW <br /> O (TYP) © 2 5/16 SPLIT WASHER NH) JI4 SITE SOLUTIONS <br /> RRU WITH ill <br /> 1 i tto8a7MwN SeIMoH <br /> Q 8 UT 1/2'SPLIT <br /> DED RODWASHER N. .. .. SUNSHIELD <br /> 0 8 1/2"SPLIT WASHER \ I —' —— I 't <br /> .11 <br /> 1 12 1/2"NUT FRONT SIDE <br /> 1 GENERAL NOTES 2 ANTENNA MOUNTING HARDWARE RRUS 32 MOUNTING DETAIL <br /> NOT TO SCALE WAVE <br /> RRUS NOTE: DIPLEXER NOTE: R G H I T E C T(J R E <br /> 1. DIPLEXERS MOUNTED AT ANTENNAS. <br /> 1. RRUS MOUNTED NEAR ANTENNAS. 2. CONTRACTOR TO VERIFY WITH <br /> 2. CONTRACTOR TO VERIFY WITH III <br /> MANUFACTURER SPEC's FOR MOUNTING 1133 184TH STREET SW <br /> MANUFACTURER SPECS FOR CHANNELS MOUNTEDDETAILS. SUITE 202 <br /> MOUNTING DETAILS. ■ ON ICE BRIDGE POST 3. DIPLEXER DETAIL AS SHOWN AS A LYNNWOOD,WA 88087 <br /> 3. RRUS DETAIL AS SHOWN ASA OFFICE:(425)7783800 <br /> '� REFERENCE AND IS SUBJECT TOPOLE MOUNTED - HEFERENSOND SUBJECT TO CHANGE.RRU " r 4. H•FRAME SHH OWN A AS TYPICAL.VERIFY JAY@NEWWAVEARCH.COM <br /> CHANGE. DIPLEXER ACTUAL CONDITIONS IN FIELD. <br /> 4. VERIFY ACTUAL CONDITIONS IN FIELD. <br /> ADAPTER11 <br /> PIPE 0 �! NOTE: / = DATE 4-21-17 <br /> " RRUS CAN ONLY BE PAINTED ON SUNSCREEN TOP ,. PREPARED BY. YML <br /> �I DIPLEXER MOUNTING <br /> .. gl <br /> VIC <br /> �, PLATE APPROVED BY JYS <br /> MOUNTING PIPE Os 5 18.5" MFR'S STANDARD 7.5" I <br /> (TYP) —O MOUNTING • ` <br /> r f�� BRACKETS �- \ .i 'i SUBMITTALS <br /> l7� .(e, r-mil- 1r ,$` .; NO DATE DESORPTION <br /> Nix� ..- <br /> 1.0._ <br /> i 77 <br /> �i jt <br /> 1Ijl <br /> RRUS , N S� II <br /> � r? <br /> 5 i 0, ■ REFER TO DETAIL-A (lei �IL7 <br /> ISOMETRIC VIEW = ONNE <br /> C <br /> _ <br /> . CONNECTION DIPLEXER <br /> r RRU WITH TO ANTENNA 4-21-17 FINAL PERMIT <br /> "-U SUNSHIELD MOUNT 4-3-17 REVISED PERMIT <br /> FRONT SIDE DETAIL-A <br /> 3-17-17 PRELIMINARY PERMIT <br /> 4 RRUS B5 MOUNTING DETAIL DIPLEXER MOUNTING DETAILS <br /> NOT TO SCALE 5 NOT TO SCALE REGISTERED <br /> HITECT <br /> " <br /> CABLE BLOCK HARDWARE KIT <br /> !���' 4.21-17 <br /> (SITE PRO#CH50(SINGLE <br /> AY Y. <br /> STACK),#CH80(DOUBLE STACK) STA OF WASHINGTON <br /> OR#CH05(TRIPLE STACK)) <br /> SEE PLAN FOR QUANTITY <br /> CABLE BLOCK <br /> (SITE PRO#CXB758 ORSITE <br /> APPROVED EQUAL) <br /> UNIVERSAL 01; <br /> ROUND-MEMBER SUPPORT <br /> �P .5 5 <br /> BRACKETSING WITH <br /> I HUTS .40.0 ...._ SIS SEA - FLUKE <br /> 4'-0"O.C.MAX. 1D) <br /> MFR.BY SITE PRO 1,#MS6. \ 2215 <br /> EXISTING MONOPOLE MERRLL CREEK PARKWAY <br /> TOWER EYERETT,WA$8203 <br /> rj:ICCI 0 .,, SHEET TITLE <br /> 9°0 r'' <br /> �,, 3-D OF SUPPORT DETAILS <br /> BRACKET-MS6. <br /> 6 ANTENNA CABLE ROUTING DETAIL SHEET NUMBER (k7/./9\. <br /> NOT TO SCALE A-4 <br />