*444,101. <br /> KEY NOTES. <br /> ANTENNA CABLE <br /> O EXISTING MONOPOLE TOWER O EXISTING COLLECTION GROUND BAR FINAL GROUND LEAD,#2 AWG RXO g g TXO • RXI WEATHERPROOFING ;.r '-= IMINI <br /> 7 STRANDED GREEN INSULATED COPPER CONDUCTOR TO EXISTING ■ KIT P O <br /> w ■ WEATHERPROOFING 2112"0 MAX. <br /> MASTER GROUND BAR AT BASE OF TOWER,NEAR EXIT PORT JUMPER REQUIRED 1! <br /> EXISTING ANTENNA PLATFROM M ,* KIT(SEE NOTE 3) <br /> 0, ONLY FOR 1 51813 COAX li 11 li <br /> STANDARD GROUND CABLE GROUND KIT <br /> Cr) EQUIPMENT GROUNDING,#2 AWG STRANDED GREEN INSULATED OR FOR EASE OF <br /> ri ``r� KIT(TYP.) <br /> O VERIZON WIRELESS ANTENNAS COPPER CONDUCTOR TO EXISTING COLLECTION GROUND BAR CONNECTION(TYP.) L � #G AWG STRANDED <br /> 3 C REFER TO NOTE. <br /> EXISTING MASTER GROUND BAR AT BASE OF TOWER,NEAR EXIT . ■ COPPER GROUND WIRE <br /> (GROUNDED TO GROUND <br /> O <br /> PORT. CONNECTOR ANTENNA CABLE IN. BAR)(SEE NOTE 1&2) M_ <br /> WEATHERPROOFING ■ CABLE TRAY TO <br /> OEXISTING MASTER GROUND BAR FINAL GROUND LEAD TO EXISTING KIT(TYP.) A) �1 AI EQUIPMENT LOCATIONLIM <br /> REFER TO NOTE 2 (TYP.) CONNECTION OF COAX CABLE GROUND KIT <br /> TOWER GROUND RING <br /> OANTENNA GROUNDING,#2 AWG STRANDED GREEN INSULATED /� ` COLLECTION GROUND TO ANTENNA CABLEladiiii. <br /> COPPER CONDUCTOR CADWELD TO BOTTOM OF ANTENNA PIPE TO / ^r © BAR MOUNTED <br /> EXISTING COLLECTION GROUND BAR AT ANTENNA LEVEL OF TOWER OOP <br /> ,_.,. i' ''''`+��A FROM ANTENNA FRAME Ate' �>]�� NEAFI/CABLE T OW <br /> AY <br /> ! ;�` SUPPORT �I , ( ANTENNA. <br /> _ REFER TO DETAIL 5, NOTES: <br /> �/ 4, O® I I THIS SHT. 1. DO NOT INSTALL CABLE GROUND KIT AT A BEND AND ALWAYS <br /> /,!�, .' TYP v :� DIRECT GROUND WIRE DOWN TO GROUND BAR. <br /> ///,i! y\`` `�� \. #2 AWG STRANDED, 2. GROUNDING KIT SHALL BE ANDREW SUREGROUND TYPE KIT WITH <br /> r< � ,7 FROM ANTENNA MAST #2 AWG STRANDED, INSULATED COPPER TWO-HOLE LUG. <br /> /r ,may�. <br /> },! ,/ , -_II // \\� it. :i,,,,,,,,..,,,,i,,,, <br /> AIR TERMINALS(WHEN INSULATED COPPER CONDUCTOR BONDED J14 SITE SOLUTIONS <br /> / REQUIRED) CONDUCTOR. TO GROUND WIRE 3, WEATHER PROOFING SHALL BE TWO-PART TAPE KIT,COLD SHRINK HweRNRwu 7eeR1aR <br /> p <br /> /� / !� '` ALONG CABLE TRAY TO SHALL NOT BE USED. <br /> /(!/f ` I ��� '�� EXTERIOR GROUND BAR. <br /> GENERAL NOTES. ip <br /> f <br /> 1. ALLCADvuELDCONNECTIONSONGALVANiZED '�� 1 / j `� ,`�`,c.. COAXIAL CABLE GROUND WIRE TO.GROUND BAR CONNECTION <br /> g <br /> SURFACES SHALL BE CLEANED THOROUGHLY :- , <br /> � .� <br /> AND COVERED WITH TWO(2)COATS OF SHERWIN !_ / '���. . ♦'� NOT TO SCALE rte.. A`/ <br /> WILLIAMS GALVANITE PAINT B350W3 OR EQUAL. ,/" S 0 �` � ,I " RCA H I T E C TT URE• <br /> 2. ALL ELECTRICAL CADWELD AND MECHANICAL ///�� - // ', ...._,,74,,, <br /> �'`-! �� #2 AWG STRANDED JUMPER WI <br /> GROUND CONNECTIONS WILL HAVE /' / ° \�\ // t 1 �- SHORT BAREL COMPESSION LUGS <br /> NON-OXIDATION COMPOUND APPLIED TO `2 f` //j '''N�.� i -` -� �: / (T&B#54205 OR#5407),USE STAR 1133 164TH STREET SW <br /> CONNECTION. / /,�, \ � . '! WASHERS,/ SHEET LOCK <br /> AL WASHERS, <br /> ASHEREWS SAND SECURE SUITE 202 <br /> '�J' p✓/ / � .--- I � !" i�/ OFFICE.(425D.)A 98037 <br /> 778.3800 <br /> 3. ANY METAL OBJECTS WITHIN 6 FEET OF THE // �, ,7j l-k I �Ai // TO EXTERNAL GROUND BAR SY ) <br /> " \ a� / 0 CONTRACTOR. JAYGNEINWAVEARCH.COM <br /> EXTERNAL GROUND RING SHALL BE GROUNDED. //./ / -�� ///j <br /> 4. ALL GROUNDING MATERIALS AND CADWELD <br /> 1.„,,.....--', -., 2A,--',`,�„ / �� j 3d TYP. <br /> MOLDS,SHOTS,ETC.,SHALL BE FURNISHED AND / COAXIAL GROUND KITS W/LONG <br /> .,1 i P BARREL COMPRESSION LUGS WI DATE. 4-21-17 <br /> INSTALLED BY CONTRACTOR,UNLESS '` -'"-rA.,., 1 rt/ 7 (2) <br /> OTHERWISE NOTED. s 4" � �/ �, TWO <br /> f> PREPARED BY. YML <br /> e !"C /� Q - INSTALLED BY CONTRACTOR. <br /> 5. THE ELECTRICAL CONTRACTOR SHALL FOLLOW �,-- O 1.<7,,,,,,/" /f 0 0 <br /> GROUNDING SYSTEM INSTALLED AND TESTING '� `. S?`� v //*-- <br /> •_1\ `., { j � `1 ,� APPROVED BY. JYS <br /> PROCEDURES AS DESCRIBED IN THE GENERAL �`�,,� �`,x !'�, / I `N/ iip977+. <br /> y`; S, 7/16"DIA.(TYP.) <br /> ELECTRICAL PROVISIONS. g- q ' / '-'°I /11,.,,,, r . "' '® H O O O O �,. O SUBMITTALS <br /> ,.:1., <br /> .,„ <br /> �.� 1� j,;° p O 0 0 O �•• 4"x 10"x 1/4"THK.COPPER GROUND <br /> ,'.. /,° 1, f✓ BAR W/4"INSULATED STAND OFF. NO DATE DESCRIPTION <br /> '�, ��8, a�� ' � / 0 (HANGER#GBI-14410)SUPPLY AND <br /> ITEM <br /> LEGEND DESCR1FMON ... ,\ *'• v'" 'I ; 0 0 <br /> INSTALL BY CONTRACTOR TYP. <br /> ® 518"DIAMETER x 10'-O LONG COPPER CLAD \ X f�/' r// #2/0 AWG INSULATED STRANDED <br /> GROUND ROD,MINIMUM 42"BELOW GRADE, ' . Ij X. 10" • COPPER CONDUCTOR DOWNLEAD <br /> � TO MASTER GROUND BAR OR <br /> AT MINIMUM 10'4'O.C.(HANGER#5810). " // OTHER FINAL GROUNDING POINT <br /> --•-- NEW MECHANICAL CONNECTION 0 - ,,' vi/ ` <br /> ---"-- EXISTING MECHANICAL CONNECTION TYP �- 4-21-17 FINAL PERMIT <br /> • - 4-3-17 REVISED PERMIT <br /> 3-17-17 PRELIMINARY PERMIT <br /> GROUNDING PLANS AND NOTES NORTH 4 NOT USED COLLECTION GROUND BAR <br /> SCALE.1/2'-I-0'(22x34), 1/4'-1-0'(11x17) NOT TO SCALE REGISTERED <br /> HITECT <br /> STRANDED CU WIRE WITH <br /> 1. ALL ELECTRICAL WORK SHALL BE PERFORMED IN ACCORDANCE WITH THE DESIGN AND 13.CONNECTIONS TO THE GROUND BUS SHALL NOT BE DOUBLED UP OR STACKED. 4 ~ !47/11 4'21-17 <br /> CONSTRUCTION SPECIFICATIONS AND ALL APPLICABLE LOCAL CODES. BACK TO BACK CONNECTIONS ON OPPOSITE SIDES OF THE GROUND BUS ARE GREEN,600V,NSIZETHASg . <br /> 2. ALL GROUNDING SHALL CONFORM TO THE CURRENT VERIZON WIRELESS STANDARDS. PERMITTED. INSULATION. AS _ Al'Y. " <br /> 3. CONDUIT ROUTINGS ARE SCHEMATIC.CONTRACTOR SHALL INSTALL CONDUITS SO THAT 14.USE OF 90°BENDS IN THE PROTECTION GROUNDING CONDUCTORS SHALL BE SPECIFIED 4111I. <br /> 3. STA OF WAStNJIGTdV <br /> ACCESS TO EQUIPMENT IS NOT BLOCKED. AVOIDED WHEN 45°BENDS CAN BE ADEQUATELY SUPPORTED. PANI SCHEME SPECIFICATIONS: <br /> 4. THE CONTRACTOR IS RESPONSIBLE FOR PROPERLY SEQUENCING GROUNDING AND 15.GROUND RING SHALL BE LOCATED A MINIMUM OF 24"BELOW GRADE OR 6"MINIMUM PRODUCER(P) <br /> UNDERGROUND CONDUIT INSTALLATION AS TO PREVENT ANY LOSS OF CONTINUITY IN BELOW THE FROST LINE. TWO-HOLE LUG, CONNECTS TO EQUIPMENT CABINETS,CABLE ENTRANCE <br /> THE GROUNDING SYSTEM OR DAMAGE TO THE CONDUIT. 16.INSTALL GROUND CONDUCTORS AND GROUND ROD MINIMUM OF 1'-0"FROM GROUND BAR ,BOLTEDTTO GROUNDC BAR WIRELESSRE), SIE EQUIPMENT <br /> FRAME GROUND BAR SITE <br /> 5. PREFABRICATED SHELTER WILL BE PROVIDED WITH INTERNAL WIRING AND EQUIPMENT EQUIPMENT CONCRETE PAD,SPREAD FOOTING,OR FENCE. x 1 1/4"STAINLES USING STEEL - (MDFB),AND STANDBY ENGINE-GENERATOR SET FRAME AND OTHER <br /> INSTALLED.FOR COMPLETE INTERNAL WIRING AND ARRANGEMENT REFER TO DRAWINGS 17.EXOTHERMIC WELD GROUND CONNECTION TO FENCE POST:TREAT WITH A COLD -I <br /> PROVIDED BY SHELTER MANUFACTURER. GALVANIZED SPRAY. HEX HEAD BOLTS AND NOISE PRODUCING EQUIPMENT <br /> 6. FOR INTERIOR EQUIPMENT LAYOUT AND LOCATION,SEE SHELTER MANUFACTURER'S 18.OBSERVE N.E.C.AND LOCAL UTILITY REQUIREMENTS FOR ELECTRICAL SERVICE HARDWARE. \ SEA - FLUKE <br /> DRAWINGS AND SPECIFICATION.IN CASE OF CONFLICT THE DRAWINGS GOVERN. GROUNDING ABSORBER(A) <br /> 7. AU.GROUND CONNECTIONS BELOW GRADE SHALL BE EXOTHERMIC(CADWELD). 19.GROUNDING ATTACHMENT TO TOWER SHALL BE AS PER MANUFACTURER'S 1' P �,N I CONNECTS TO THE EARTH ELECTRODE SYSTEM INCLUDING CENTRAL <br /> 8. ALL GROUND CONNECTIONS ABOVE GRADE(INTERIOR&EXTERIOR)SHALL BE FORMED RECOMMENDATIONS OR AT GROUNDING POINTS PROVIDED(2 MINIMUM) GROUND RAR ON WALL, 0 /1 O O O HOC) Q WATER GROUND GRID,BUILDING STRUCTURAL GROUND,METALLIC (MQp) <br /> USING TWO(2)HIGH PRESS CRIMPS. 20.MAXIMUM RESISTANCE OF THE COMPLETED GROUND SYSTEM SHALL NOT EXCEED 5 FLOOR OR ON ANTENNA �:/ ��L���J\ WATER PIPE SYSTEM,ANTENNA SUPPORTING STRUCTURE GROUND <br /> 9. ALL EXOTHERMIC CONNECTIONS TO THE GROUND RODS SHALL START AT THE TOP& OHMS. TOWER \0 0 C>O O `\�J 0 0 O SYSTEM,AND ELECTRICAL SERVICE ENTRANCE GROUND 2215 <br /> HAVE A VERTICAL SEPARATION OF 6"FOR EVERY ADDITIONAL CONNECTION. 21,MINIMUM BENDING RADIUS FOR GROUNDING CONDUCTORS IS 8"WHEN BENDING IS �:./ NON-ISOLATED(N) MERRLL CREEK PARKWAY <br /> 10.ALL GROUNDING CONNECTORS TO BE CLEAN AND FREE OF PAINT AT THEIR MATING NECESSARY.GROUND CONDUCTORS ARE TO BE AS STRAIGHT AS POSSIBLE. O • • •%/ <br /> SURFACES AND INSTALL PER MANUFACTURER'S RECOMMENDATIONS.ALL EXTERIOR 22.NO SPLICES PERMITTED IN GROUND CONDUCTORS. CAD WELD WITH#2/0 AWG i/lfl! r CONNECTS TO EQUIPMENT NOT IN AN ISOLATED GROUND ZONE(IGZ) EVERETT,WA 98208 <br /> GROUND CONNECTIONS SHALL BE COATED WITH ACORROSION RESISTANT MATERIAL. 23.ENSURE ALL MECHANICAL CONNECTORS ARE TORQUED TO THE MANUFACTURER'S SOLID TINNED NAGE CU oll SUCHASCBN EQUIPMENT FRAME GROUNDS AND DCCBN GROUND <br /> 11.ALL EXTERIOR GROUND CONDUCTORS SHALL BE#2 AVM TIN PLATED COPPER UNLESS SPECIFIED VALUES. WIRE OR STRANDED CU CONDUCTORS FOR DC POWER SYSTEMS THAT SERVE CBN OR BOTH <br /> OTHERWISE INDICATED. 24.GROUND BARS SHALL NOT BE FIELD MODIFIED. WIRE WITH GREEN,600V, CBN AND ISN EQUIPMENT <br /> 12.GROUND RODS SHALL BE STAINLESS STEEL OR COPPER CLAD STEEL,5/8°010-FT.LONG, 25.ALL HORIZONTAL FENCE SECTIONS TO BE GROUNDED WITH 8"SINGLE BARREL TO N/TEN N INSULATION L- SHEET TITLE <br /> AND SHALL BE DRIVEN VERTICALLY WITH THEIR TOPS 18"BELOW FINAL GRADE OR 6" GROUND STRAPS. TO ANTENNA STRUCTURE, ISOLATED(I) <br /> BUILDING,RING GROUND "GROUND BARS AT BOTTOM OF CONNECTS TO THE SINGLE POINT CONNECTION BAR(SPCB),FOR IBN <br /> BELOW FROST LINE FOR MAXIMUM DEPTH. 26.USE PANI SCHEME FOR LOADING ON MGB AS DISCUSSED IN NSTD 119,33&36. OR MOB TOWERS OR MONOPOLES SHALL EQUIPMENT GROUNDING PLAN, <br /> USE EXOTHERMIC CONNECTION. DETAILS <br /> AND NOTES <br /> SHEET NUMBER <br /> GENERAL NOTES GROUND BAR CONNECTION DETAIL AND NOTES liN <br /> 2 V NOT TO SCALE E-1 ` ..., <br />