Laserfiche WebLink
Date: April 12,2017 <br /> Cathy Garziano Tower Engineering Professionals <br /> Crown Castle 326 Tryon Road <br /> 2055 S. Stearman Drive Raleigh, NC 27603 <br /> Chandler, AZ 85286 (919) 661-6351 <br /> (480) 735-6952 crown@tepgroup.net <br /> Subject: Structural Analysis Report <br /> Carrier Designation: Verizon Wireless Co-Locate <br /> Carrier Site Number: 263739 <br /> Carrier Site Name: Sea Fluke <br /> Crown Castle Designation: Crown Castle BU Number: 826263 <br /> Crown Castle Site Name: Norpro <br /> Crown Castle JDE Job Number: 434562 <br /> Crown Castle Work Order Number: 1391140 <br /> Crown Castle Application Number: 387666 Rev. 1 <br /> Engineering Firm Designation: TEP Project Number: 46302.115847 <br /> Site Data: 2215 Merrill Creek Pky., Everett, Snohomish County, WA 98203 <br /> Latitude 47°56'32.81" Longitude -122°15'42.95" <br /> 150 Foot-Monopole Tower <br /> Dear Cathy Garziano, <br /> Tower Engineering Professionals is pleased to submit this "Structural Analysis Report" to determine the <br /> structural integrity of the above mentioned tower. This analysis has been performed in accordance with the <br /> Crown Castle Structural `Statement of Work' and the terms of Crown Castle Purchase Order Number 1024852, <br /> in accordance with application 387666, revision 1. <br /> The purpose of the analysis is to determine acceptability of the tower stress level. Based on our analysis we <br /> have determined the tower stress level for the structure and foundation, under the following load case, to be: <br /> LC5: Existing + Proposed Equipment Sufficient Capacity <br /> Note:See Table I and Table II for the proposed and existing loading, respectively. <br /> The analysis has been performed in accordance with the 2016 Washington Building Code, WAC Chapter 51-50 <br /> (2015 International Building Code) based upon an ultimate 3-second gust wind speed of 110 mph converted to a <br /> nominal 3-second gust wind speed of 85 mph per Section 1609.3.1 as required for use in the TIA-222-G <br /> Standard per Exception #5 of Section 1609.1.1. Exposure Category C and Risk Category II were used in this <br /> analysis. The Seismic Design Category is D and the Site Class is C, as determined in "Appendix C—Additional <br /> Calculations"of this report. <br /> All modifications and equipment proposed in this report shall be installed in accordance with the appurtenances <br /> listed in Tables 1 and 2 and the attached drawing for the determined available structural capacity to be effective. <br /> We at Tower Engineering Professionals appreciate the opportunity of providing our continuing professional <br /> services to you and Crown Castle. If you have any questions or need further assistance on this or any other <br /> projects please give us a call. <br /> ti <br /> Structural analysis prepared by: Steven C. Williams, E.I. /MZS <br /> Respectfully submitted by: <br /> • li <br /> JI, <br /> Ryan J. Rimmele, P.E., S.E. <br /> • <br /> 4 .✓ t <br />