<br /> GENERAL NOTES
<br /> --------=----------=-------- � ;
<br /> TNIS ELECTRICAL PLAN IS THE ARCHITECT'S SUGGESTED LAYOUT. THE � 0 � �
<br /> ELECTRICAL CONTRACT IS ON A DESIGN-BUILD BASIS. ELECTRICAL � � '
<br /> CONTRACTOR'S DESIGN SHAL� BE APPROVED BY THE OWNER AND SHALL � �
<br /> CONFORM TO THE APPLICABLE ELECTRIC CODE REGARDLESS OF WHAT IS � �
<br /> � SHOWN ON THIS DRAWING. ��� I 1 ' �
<br /> Patio , , �
<br /> � � ,� ,
<br /> METER CENTER LQCATIONS SHALL BE COORDINATED WITH THE ARCHITECT. � -' � I I �
<br /> � I � I
<br /> .
<br /> HIGHEST OPERABLE PART OF ENVIRONMENTAL AND OTHER CONTROLS SHALL �___� � � { '� �, � �, � � ,
<br /> MOUNTED NOT LESS THAN 36 WCNES ABOVE FLOOR. ELECTRICAL AND _ � {
<br /> CQMMUNICATIONS SYSTEMS ON WALLS SHALL BE MOUNTED A MIN. OF 15 � I � ' '
<br /> INCNES ABOVE FLOOR. TV � T� � �. 1 � TE� �� � �� � � � � � C � S ;
<br /> 750 750W WALL � �,
<br /> 1250W ELEC � � I \ � 1250W ELEC Tv CEILING HEATER UNIT NEATER ;
<br /> OUTLETS, SWITCHES, TELEPNONE AND TV, ETC. BOXES IN PARTY WALLS OF cEiuNc H�arE� i � � _. cEiuNc HEarER ,
<br /> i � �5 ����r�t Wa�r Sr��t���{� :
<br /> ONE UNIT SHALL BE IN DIFFERENT STUD SPACES THAN THOSE IN � � � � � � WH �
<br /> THE ADJACENT UNIT. NO TWO ADJACENT UNITS SHALL HAVE SUCH BOXES i � ' � I ' I4ti'�IT�[i�r�a��#l�F��`ti#i ����`� .'
<br /> IN THE SAME STUD SPACE. BOXES SHALL BE SEPARATED HOR�ZONTALLY � ^ � � __�-1 � � � �,��54���'��� � �`�.�Yb������� �;
<br /> �
<br /> „ , i � � i �������������9�����i��rn
<br /> BY 24 . I - ' PW r.SMURF %" Living
<br /> ,��. �.. -„_ .
<br /> INDIVIDUAL ELECTRICAL OUTLET BOXES SHALL BE OF STEEL OR OTHER � I W.I.C. CFP � �-� i I TV
<br /> APPROVED MATERIAL AND SHALL NOT BE GREATER THAN 16 SQUARE � � \ � `- j I
<br /> INCHES IN AREA. , � � 1 �., �,
<br /> , � � , ^� � � � , Bonus Room
<br /> � � Ma.StCr BCdrOOCTI �. _ � . 5052 REGISTERED
<br /> THE WATER HEATERS SHALL BE STRAPPED PER IRC P2801.7 AT A POINT , i � i -- � r � i � � �' ARCHITECT
<br /> � i , � i � � i �
<br /> � � � � �
<br /> WITNIN THE UPPER 1 3 AND THE LOWER 1/3 OF ITS VERTICAL DlMENSION. � - - �, _ � �
<br /> THE LOWER STRAP SNALL BE NOT LESS THAN 4" ABOVE ANY CONTROLS. � j � 1 TEL � \ �' �. � - ' � - - � �
<br /> WATER NEATERS SHALL BE PROVIDED WITH A PRESSURE/TEMPERATURE i � / � � �. � � � - - � / \ �� � 'TOP � � � ROBERT E. WEIBLE
<br /> R E L I E F V A L V E T H A T (S C O N N E C T E D T O A D R A I N L I N E. T H E D R A I N L I N E � � i � � � � --- - - - - - / H A L � r S T A T E O F W A S H I N G T O N
<br /> ' �.-, _ _ -,� , I � j
<br /> SNA�L BE DIRECTED TOWARD TNE GROUND AND TERMINATE AT A POINT NO � t � � p
<br /> LESS THAN 6" AND NO MORE THAN 24" ABOVE THE GROUND. �---- � / / �--, �--_ , ---- ---- ---- --------- ---------.. ---- ,_ -_--------- �_—_ �
<br /> � SD ; ; � � -------- � ° .`:� a
<br /> ------- ----- , T
<br /> < ..
<br /> ------------------ -- - - ---
<br /> SMOKE DETECTORS SHALL BE EQUIPPED WITH A BATTERY BACK-UP, SHALL � � � E T L -, � , � ' .--.---, StOC. ` .
<br /> -------- <
<br /> � �
<br /> EMIT A SiGNAL WHEN BATTERIES ARE LOW, SNALL BE PERMANENTLY HARD � � � o "-�--- -- I T� I � � � �
<br /> WIRED AND WITHQUT A DISCONNECTING SWITCH OTHER THAN TF�EOSE � 1 � ; � _ a- �
<br /> REQtJiRED FOR OVERCURRENT PROTECTION, AND SHALL SOUND AN ALARM j ( ' _ - _ ��. BELO � � I I �;
<br /> 1 I � \ �. � IT � i � -. J � ; 250W LL � � �'
<br /> AUDIBLE !N ALL SLEEPING AREAS OF TNE DWELLiNG IN WHICH THEY ARE , � � � � , � � � � '� m � ; � uNiT ye rE � � aa �
<br /> LOCATED. � � I � -�
<br /> 1 � � / � � i ; , � �� �
<br /> � � � a
<br /> ENERGY NC)TES � � ' ' � � � E � ry ��—� ; ;
<br /> , M. Bath � ' ,' , ' Dining � _ _ � \ ; ! , PB TTr � � � �
<br /> SEE ENERGY NOTES ON SHEET A1 & D5. � � � � _ � � � � ; ; � � I I I I I ��._.� � �
<br /> �000w TA K CHIME , �
<br /> \ i , \ I I f I I I "
<br /> H M sraT '
<br /> , - - ELEC � \ � � � � i I I I I � 8 z
<br /> WATER HEATER SHALL BE FUELED BY GAS AND HAVE A MfNIMUM EF OF , +F�� �� HEATER � � _._., l �� � � T � ; ; � \� � � ; � � � da �
<br /> Q.U2. � � M . . . . . _. .. \ ' M . . .. . . . .. � � I I I � . L—�---�--�--� .. � �
<br /> I . , �__� � \��. � ' � � ...8 � .
<br /> j i i +44' ---- -------�------ � �
<br /> NOT AND COLD WATER HEATER PIPES !N UNGONQITIONED SPACES SHALL BE I � � , � , WASH�RA �--� f d : < ." a V
<br /> INSULATED WITH R-3 INSULATION WHICH HAS A FLAME SPREAD OF 25 OR ' ! � ��= � � �" L i +�¢s � �� � r � � � � ' � I �
<br /> �Ess. ' Bath '- F ' � �wHF� i --------------- ------ ------ -- - --.- - -- i � � � i � i �
<br /> � �
<br /> � VTR j L_J .. .._ . . ... .... . . r � i �
<br /> i 'i i i �:......., .. i i i i j .n
<br /> VENTILATIC�N NOTES ' o �TR � ' _-�___�____�-______- _�______ ,;�. , � � _
<br /> .
<br /> � ' %� Lau n ry � 48" � __ _ � -�.-, ; ; ! ; , !.� ' �
<br /> +� �==- -=. � �
<br /> DRYE�Z � � / � � ���� i i � i i �
<br /> / \ �.CEfLING Q
<br /> VENTILATION: SEE NOTES ON COVER SHEET. �
<br /> � �
<br /> � --------- , _ - - - _. / � � \ I � � I I ' � �. 2x8 FRAMING FOR -.; � t
<br /> - , _. .
<br /> � � � - _ _ � � � � ' � �. ELEC. ENTRANCE ° TO , a ,�
<br /> ALL EXHAUST DUCTS SHALL BE RIGID METAL, AND SHALL BE FITTED WITH A sD 1 � � � � �
<br /> o �
<br /> TIGHT FITTING BACKDRAFT DAMPER CAPAB�E OF CLOSfNG WHEN THE FAN IS ' � � j � i � I ; ; ; ; � � � Garage \ �. 14" CLEAR INSIDE e ENTRY � �
<br /> NOT W USE. STACK �. � I I ; ' ' ; �
<br /> , � 1 � ; i I ; ; ; ; I � � / AT CEILING; PREWIRE \ � � { a" `� @ Z O
<br /> ; THERMOSTAT� I
<br /> DUCTS IN UNHEATED SPACES INCLUDING ATTICS SHALL BE INSULATED TO A & SWITCH � � T STACK i � ' ' Kitche / ��N �_ ' ' _� i LOW VOLTAGE WIRE FOR � ELEC a _ �
<br /> � r 1 � �I � � , � GARAGE DOOR OPENER � PANEL ; J�
<br /> MlNIMUM OF R-8. , SD THERMOSTAT , � I
<br /> � � & SWITCH � Fami ly � � ; � I i AND ELECTRIC EYES �. �
<br /> / j � � � I � V�RIFY LOCATION W1TH �.
<br /> TOP FLOOR EXHAUST FANS SNALL VENT THROUGH ATT1C. , � ; , � �.` �; i \ � f/ OPENER iNSTALLATION �\ A F.F �
<br /> � cc
<br /> DRYER EXHAUST DUCT SHALL BE 4" RIGID METAL WITH A 4" OPENING ON i� TV � , ! 1 � ; ; � � ______ � j � �, � SLAB 4 0
<br /> 7HE EXHAUST HOOD. THE DRYERS DUCTS SHALL SE GALVANIZED STEEL OR � � � I j � ; ; � � � � �. �, c;+
<br /> i � .�
<br /> ALUMINUM, MINIMUM 0.016" 7HICK, TNE DRYERS SHALL BE GENERAL � � � , I � -�-� �� DW I '� O � , `'' � o �
<br /> ELECTRIC. DRYERS SHALL BE 1NSTALLED ACCORDING TO MANUFACTURER'S TV i j I I� i � � j t �
<br /> - INSTALLATION INSTRUCTIONS ON SITE. B2CIt"OOC7l Bedroom 2 j � � �__ � i +Ips° � Q i
<br /> ' ' j i � HOSE �
<br /> WiNDOW OUTDOOR AIR WLETS SHALL PROVIDE THE EQUlVALENT OF 4 SQ. -- - - �. 1 �F� BIBB I
<br /> ---- —�------�------/-------�----- --- � �
<br /> IN. OF NET FREE F�REA. �, � � _ _ _ _ Z
<br /> cc
<br /> � � - �. � /� _.- � `. - _ „ � / �
<br /> 1000W ELEC TOP HALF �. 1250W ELEC TEL � i ` � ' ` � � � � a' 0
<br /> � CEILING HEATER \ f � - /CEILING HEATE � � � � �. � _ _ _ � � J o �
<br /> i , �� �
<br /> 750W ELEG -.� I
<br /> GEILING HEATER T� ----------� �
<br /> � PHOTOCELL f ---T----�--� �
<br /> `--------------------� � 4
<br /> � v
<br /> Z � �
<br /> ELECTRICAL LEGEN D � v � ;
<br /> UPPER LEVE� MAIN LEVEL LOWER LEVEL —Wi
<br /> 00
<br /> � DUPLEX RECEPTACLE OUTLET DIRECTIONAL CEILING U N 1 T G UTI LITY PLAN U � I T G UTI LITY PLAN � N I T � UTI LITY PLAN W
<br /> MOUNTED LIGHT
<br /> � DUPLEX RECEPTACLE OUTLET 1/4"=1'-0" 1 J4"=1'-0" 1/4"=1'-0"
<br /> SPLIT W(RED (SWITCH TOP HALF) � GEILING MOUNTED LIGHT o
<br /> M� DUPLEX RECEPTACLE OUTLET
<br /> � �
<br /> MICRQWAVE � RECESSED CEILING LlGNT; �
<br /> IC RATED - SEE 92/Q1
<br /> � SINGLE RECEPTACLE OUTLET
<br /> �
<br /> 208v (R: RANGE, D: DRYER) -�- WALL MOUNfiED LfGHT
<br /> Q JUNCTION BOX
<br /> �F+
<br /> DOUBLE TUBE FLUORESCENT �
<br /> � TECH PORT CEIL,ING MOUNTED LIGNT �
<br /> TEL� TELEPHONE JACK �- GEIUNG MOUNTED TRACK LIGNT �
<br /> —� � �
<br /> TV TELEVISION JACK � HEAT LAMP, EXNAUST FAN �
<br /> � S(NGLE PQLE SWITCH COMBINATION RECESSED CEfLING O �
<br /> FIXTURE - 250W LAMP, 50 CFM � �
<br /> 3 THREE WAY SWITCH MIN., 3 SONES, 4" ROUND DUCT.
<br /> � SEE 95/D1 � �
<br /> DIM.� DIMMER SWITCN =������� BEARING WALL - SEE NO7ES W Q 0 U
<br /> THIS SNEET REGARDING BOXES
<br /> �T TIMER SWITCH AND FIRE-RATED WALLS � Q� � N
<br /> � RECESSED GEILING EXHAUST FAN � METER CENTER � � � �
<br /> 50 CFM MIN, 3 SONES MAX, O � �
<br /> 4" ROUND DUCT. SEE 15/D1 o ELECTRICAL PANEL � �
<br /> � esH ELECTRIG BASEBOARD = a.+" �
<br /> MICROWAVE OVEN/RANGE HOOD �
<br /> �
<br /> MW� COMBINATION, 100 CFM, 3 SONES HEATER � � � O
<br /> SMOOTN DUCT. OT THERMOSTAT
<br /> W 0 > Z
<br /> � RECESSED HEAT LAMP - � SMQKE DETECTQR � W �
<br /> "f" NUTONE 9410H, 250W LAMP WITH BATTERY BACKUP .�.� O
<br /> CEILING FIXTURE. SEE 12/D1 '�' �
<br /> CARBON MONOXIDE _ �
<br /> PHOTOCELL SAFETY SENSOR ALARM/SMOKE DETECTOR �
<br /> � �
<br /> ❑ TECH PANEL � AUDIBLE SPRINKLER � 0'
<br /> SFA FLOW ALARM �
<br /> � RECESSED CEILING WHOLE WINDOW WITH OUTQOOR ' �
<br /> �F HOUSE EXHAUST FAN �- AIR INLET Q
<br /> 80 CFM MIN., 120 CFM MAX.,
<br /> 1.5 SONES, 6" ROUND DUC�
<br /> �PB PUSH BUTTON
<br /> o Job No.: 13-47
<br /> � Sheet No.:
<br /> VTR VENT THROUGH ROOF
<br /> z
<br /> � U15�
<br /> Sheet Order: A B U F R E S D I ..
<br /> _
<br />
|