Laserfiche WebLink
__ _ __ _ _ <br /> COMPOSITION ROOFING <br /> � METAL FLASHING OVER ROOF SHEATHING <br /> 1 x3 TRIM 12 <br /> 2 LET-W OR HOLD 6 � <br /> OUTRfGGER DOWN TOP CNORD <br /> OF GABLE TRUSS <br /> 5/4x8 RAKE BOARD A35 AT 4 METAL +8�-8'�4�� <br /> EASE FACE EDGES EACH BEAM FLASHING COMPOSITION RQOFING FOR OUTRIGGERS � ABOVE <br /> L� 2X4 TRfM I � 1X3 TRlM OVER ROOF SHEATHING � A35 MAAT 24TRU�S�SES INTERIOR <br /> , F.F. <br /> ' . GABLE TRUSS � - -- , <br /> � 2x8 RAKE 2 2 2 \ 2 '' <br /> ' <br /> 1'-0" i BOARD A 3 5 A T �-VENTE FIBER- <br /> � z � <br /> ,� � '�� � � �! � ;C I � �1; � � <br /> ,, 2 , CEMENT SOFFIT „ <br /> � CHAMFER EACH BEAM <br /> 6x10 BEAM TO ; '� TOP OF , � , , ���� 4 �� � <br /> BOXED � � ��' � � �;� � � � S_� ; <br /> EXTEND BACK AND � � EXPOSED '--� 2X4 TRIM ; � � BEAM +7'-11" � � �, <br /> ' ABOVE : � <br /> ATTACH TO TRUSS � ' BEAM 10° � ; � f, �o io io �o ! FRAMING �NTERIOR �� ��nti��tl We��+, ���f�2�U! <br /> TOE NAIL BEAM ' ATTIC , , , - GABLE TRUSS <br /> F.F. <br /> TO BLOCKWG ; � 1'-6" � 2 ���2������� ����6�$�C�{�$ ; <br /> � , ; <br /> � � � <br /> � 4X8 BEAM � 2 2x10 BEAM 2x10 TRIM OVER � " <br /> '/z PLYWOOD ��`� ��r'�`'�i���k����i�€h�e��t` '; <br /> � EASE EDGES� � TYP. EACH SlDE ` a <br /> TOE NAIL BEAM COL. BEYOND <br /> 5!a" TRIM UNDER BEAM DEATIL, � I TO BLOCKING » » <br /> SEE ELEVATIONS HARDIPANEL SMOOTH SOFFITING <br /> ; i I NON-VENTED <br /> 5052 REGISTEREQ <br /> SIQING � I I SIDING � CAULK GAP BETWEEN 1x4 AND � ARCHITECT <br /> ; OVER SNEATHlNG SOFFIT AT THIS LOCATION � <br /> STRUCT. <br /> DECORATIVE GABLE BEAM POST <br /> VENT BLOCK �2 STAT�BEOF WA HE NGTON <br /> 7 W/ (3) 2" o�A. 4 � MA��F. �R�SSES BOXED BEAM SECTI�N <br /> 1` SCREENED VENTS <br /> � �; � <br /> �� = � �� 1-1/2�� - ,�-o�� SECTI4N <br /> 1-1/2 � -o ECTI N 3�4 63/4 AT 24 O.C. <br /> METAL EAVE � <br /> FLASHING ' A35 i � � <br /> EASE FACE 1 -6 - ---�-- � <br /> EDGES AT z z 2 � 2 il -- - -. .--,- --- � <br /> END ' VINYL SQFFIT f `^ <br /> � <br /> �X8-\� 2x10 TRIM ' II OVER (2) LAYERS TYPE 'X' GWB �a' <br /> 3" �'�?�2" �X8 FORMS BOXED-BEAM OVER �/2" FURR STRIPS AT 24" O.C. - <br /> � <br /> (2)2x10 BEAM I�� �'�, � BOXED-BEAM FRAMWG <br /> POST CAP PER � 10 �o io 2 2 �o �� ___TYP._(3) SIDES OF PATIO � <br /> - --- --� <br /> rRAMING PLANS �, ' � � � � <br /> '� ' 2 4 �; 2x10 TRIM, FORMS BOXED-BEAM <br /> 3X3 �� 1x4 TRIM, TYP. AL.L FOUR SIQES � <br /> FIRE BLOCKING AT I � COMPOSITION SHINGLES <br /> TOP OF COLUMN ONLY '� � � f� <br /> _ � i I QVER ROQF SHEATHING STRUC. a <br /> i CENTER ; � 3" ROUND ALUM. OR PVC VENT P�ST <br /> ALL <br /> 4x4 STRUCT, POST � � PAINT TO MATCH TRlM 12 Q <br /> � VENT BLOCK -a <br /> 2x6 PARTS LOCATE ON INSIDE COLUMN FACE 6 � <br /> 3X3 ON 2X6 PER ROOF PLAN 10" � W/ (3) 2" DEA. <br /> TRIM � $CREENEQ VENTS � M <br /> (RIP IF 2 Z i� �/s" x 1%a" CORiVER TRIM o <br /> _ NECESSARY) I TYP. ALL CORNERS <br /> ' � � � � <br /> �' ( 4 ' 4 � '' HARDIPANEL "SMOOTH" OVER o '�- <br /> I <br /> 2X3 2X3 � �--- 2 4 �'I %z" PLYWOOD SHEATHING OVER FLASH NG o <br /> t° � �;I; 2x FRAMING +8'-S�/4" 13�4" � o O <br /> I z <br /> � 2 4 � 4 � ( �' T O P P L A T E S A B O V E NT. F.F. 5� <br /> � <br /> 4 2 4 �_T_ .���f � , <br /> ��� 2 � i � <br /> BRACKET IS NOT STRUCTURAL FIBER CEM NT SQFFIT � � <br /> - P.T. PLYWOOD BASE (BELOW) WITH STR P VENTING , ' '�' 2x10 � cc <br /> BRACKET " UPPER C'OLUMN PLAN CUT OUT FOR POST i FORMS o r <br /> 1 A 3 ROUND ALUM. OR PVC VENT BOXED- EAM FRAMlNG <br /> L. 4x4 P.T. POST WITH ABU44 ;', ' � BOXED-BEAM � N <br /> � t P A I N T T O M A T C H T R I M , T Y P. (3) S D E S O F P A T I O ' I�'� � r, <br /> 1-1/2" = 1'-0" L O C A T E O N I N S I D E G O L U M N F A C E ' 3/4" P.T. P L Y W O O D, C U T O U T F Q R P O S T B A S E � �0 2 �� 4x10 BEAM �, <br /> HARDIPANEL "SMOOTH" ' I�'� BUILDING PAPER LAPS OVER MTL FLASHING --- --------- �, 4 ; POST CAP PER <br /> fe"x1%a" CORNER TRIM "� � 2x10 TRIM, FORMS ; , FRAMING PLANS <br /> 5/4 x 4 TRIM, CHAMFER TOP TQ DRAIN � ; 4 2 � „ ' <br /> TOP OF FLASNING %4"x 4 TRIM � BOXED-BEAM I ' 1 -0" OH <br /> MTL FLASNlNG ON TOP CONT. BEAD OF CAULK 1x4 TRIM, TYP. � <br /> 100 DEGREES LAP W.R.B. OVE z ��' FIRE BLOCKING AT � <br /> 2x6 CAP TRIM ' NOLD HARDIPANEL �/2" UP FROM FLASHING ALL FOUR S1DES � i �- <br /> '�, (PRE-FLASH) AND � I > �,! , T UC ,� TOP OF COLUMN ONLY �; Q <br /> N METAL FLASHING ` � � SLOPED 2x6 CAP TRIM m P ST � y a N <br /> 2 a. a q 'I 4x4 P.T. PQST � � <br /> , � ; D1 m T.O. CMU/CONC. � 2 4 2x4 P.T. SPACER � 3" ROUND ALUM. ; ';� � o <br /> �MOUNT BOARD ; r'�1 � � 5 '� Q ' 5/4 x 6 SK(RT TRIM OVER Y2" PLYWD. SPACER j OR PVC VENT � �� <br /> FLASNING � �; ; o � / x 6� SKlRT TRIM � � . F., PAINT TQ MATCH TRIM ��� � <br /> �� � � v P _ a � � + ���� ��� � <br /> f�OCATE ON <br /> I � � INSIDE COLUMN FACE i�' � � <br /> 3x10 P.T. TRELLI --� � � HARDIPANEL � Q �� - HARDIPANEL SMOOTH OVER 1x4 P.T. FURRING � <br /> ; m o �' m <br /> � `t v 1x2/1x23/a" TRIM , ° �1 � 16x16x8 CMU FILLED SOLID W/ CONC. � COVERED PORCN � � 3 <br /> , ; �-� � <br /> ��� - � <br /> � I � `� 1x2" TRIM „ „ � � <br /> ; 2x10 MOUNTlNG + � �/s x 1�/4 CORNER TRIM - - <br /> � BOARD, TO 1x2�/4" TRlM TYP. ALL CORNERS ' i 2 4 z 4 � <br /> T RI GE �_= I BLOCKING ' HARDEPANEL "SMOOTH" OV�R /z" P(,YWOOD i � �' <br /> � HARDIPANE� SMOOTH i � � , l � <br /> ; � ; ¢ <br /> " � � <br /> - � � � ' � ° { � � SHEATHING OV�R �'� � c� <br /> ; 2 i � ; g�. I a 9�/g 16x16x8 CMU FILLED SOLID WITH CONCRETE 2x FRAMWG ji , _I_ � � ' `" � d <br /> � � � d a �,, i 2 0 0 '�.. <br /> , �� � INSTALL W.R.B. UNDER � � � ��-,-�I TOP PLATES ABQVE ; ,' 4 4 ��� "' j <br /> � �' MOUNTING BOARD, � � ° .�� � � � a �' I 4 <br /> "i' j 4x4 WOOD POST AB4VE <br /> TYP. RAKE � i (PRE-FLASH), SLIP W.R.B. � �_�_� <br /> ; ' SIDING � UP & UNDER PRE-FLASH � a <br /> i AT WALL 1x4 P.T. FURR STRIP AT EACH GORNER <br /> �1�+ <br /> � � OVER SHEATHING `� <br /> i 2'-0" i = <br /> i i II <br /> i � <br /> i. <br /> i � <br /> i I- <br /> I <br /> = � �li ATTIC 1'-0" 6" HARDIPANEL � �I � <br /> ; � L4WER C�oLUMN PLAN , 2�.� '�!, � <br /> � 1 x 2/ x 4 T R I M � � <br /> ' 2X8 P.T. � � <br /> � �; I ��.-=_=�- I' ' I � <br /> ;i � � 3 ROUND ALUM. , I)i O � <br /> ; I, H A RDIPANEL "SMOOTH" OVER 1x4 P.T. FURRING O R PVC VENT ' I; � � Q <br /> HARDIPANEL > � <br /> 1 0 i; ___�^ a PAINT TO MATCH TRIM , � <br /> �i � 1x2�1x23/a" TRIM , � a. 16x16x8 CMU FILLED SOLID WITH CONCRETE LOCATE ON � �� � <br /> � � � Q � INSIDE COLUMN FACE � <br /> � ' �'�, 3X10 P.T. EA. SIDE ----�- ' �� � � � � V <br /> � ) -- -- —--— 2 �8 TRIM <br /> , x <br /> _-- -- <br /> ; �,\ � '�,\ a � � 4x4 P.T. POST � (� � N <br /> � , q.5° �•, �,� 2x8 TRIM a p� POST BASE � � � <br /> LOUVER ASS Y � ,\ ,\ � a 2x8 TRIM, CHAMFER TOP 20B � <br /> . . » , PER STRUC. <br /> I OVER BLDG. CO �, �, �__ -_ � SLOPE �/a PER FOOT ( O c'C � <br /> PAPER. � �` ��i" GAP MINIMUM <br /> �� � SLAB EDGE BEYOND a >, � 2x8 TRIM, CHAMFER TOP � � ._ <br /> �I d , a : . 3�/2 CONG SLAB ' ' �/2" GAP MIN)MUM � _ ++ � <br /> SEE STRUCTURAL SHEETS FOR i l �+. <br /> ' THRU-BOLT � � - " � <br /> - COLR JOINT " � FOO7ING DETAIL AND PaST BASE V � � O <br /> � & WASHERS 45° � � � �. '- � .a � - � i l a <br /> li � � - - _��_.__--�_-tt�---_--=--a� � � ATTACHMENT � � Q � Z <br /> - �-- . . - � � W <br /> \ 4X4 PT - - - —� ` � — — — I I <br /> i BRACKET Q �° �� S UGT. . a � � � �_ � � _� y � I I I=I ( I—� I I=I I Q I" .�.r W O <br /> i; r" > �Q POST a - -° - —� 69� � �� ; iy { I .� <br /> ! --� - ( �—I i�—���—� ( (—� — a. � <br /> � __= _� —� —� -,� - : . � . . a " a � - a I � �—d . ,���r� �—I�� � C-I����—� � � a 3 � _ >+ <br /> — <br /> , <br /> —11_, , I, � �Il �lll� � � � <br /> �, <br /> I n O � <br /> ii ' � I=1 I � <br /> I� a CONCRETE FOOTING � � <br /> ELEVATION SECTION SIDE ELEVATION _ <br /> SEE STRUC. SHEETS II 8 SEE STRUCTURAL � � <br /> FOR FOQT►NG DETAIL �i FOR REINFORCWG � � <br /> � <br /> a <br /> . J . . . ... . . . . <br /> � <br /> DECORATIVE CABLE VENT �j FACE-MOUNT CARA�E TRELLfS TYPICAL PORCH C4LUMf� AND ROOF UNIT G/G1 COLUMN o 1obNo.: 13-47 <br /> 2 0 ,> > „ � "' » , » �� » , „ � �, , �, � Sheet No.: <br /> 1-1/2 = 1 -0 ELEVATION & SECTION 1 1/2 = 1 -0 1-1/2 = 1 -0 1-1/2 = 1 -0 0 <br /> ^ D6� <br /> sheet ora�r: A B U F R E S D I �� <br /> _ <br />