|
GABLE END GIRDER TRUSS
<br /> i
<br /> QRAG TRUSS 250 PLF U.N.O.
<br /> i PER PLAN 3
<br /> S9.3
<br /> i � � � o
<br /> i ^
<br /> �
<br /> w
<br /> i, I I �
<br /> II II I I I I
<br /> � f C� �
<br /> � - - - II II II II II II � r
<br /> - - - - - - - - --� z �
<br /> f f I U2 rs
<br /> II I � II ( I ( I II I PL2 �. . 3/4�, r
<br /> I _ _ � � �
<br /> i 6'-Q" � � o �'
<br /> II I II II II II , � � o
<br /> .
<br /> I I I I II II � �� � �
<br /> MST PER PLAN MST PER PLAN I 4 °�' �
<br /> i � _ PL. 26'-11" � � �
<br /> i � . ,
<br /> HEADER
<br /> (U o
<br /> — — — — — �- +, �?
<br /> , . . . . . .
<br /> — — RE: ARCH, FOR HT. �
<br /> 2'-2" g'_6" 4,^8,� TYPICA� �� �
<br /> l.TP4 W � ^
<br /> >
<br /> i
<br /> PLAN � � � ,
<br /> � - � �, �'
<br /> SCALE: 3/4" = 1'-0" � ,� �
<br /> ROOF ABQ1lE ��IIT E3 MSTR BDRM NEAOER
<br /> U � �
<br /> 4 � z �
<br /> RE: ARCH. FOR NT.
<br /> MST PER PLAN M5T PER PLAN TYPICAL i i- o �
<br /> �i i � � o
<br /> � U) .-, �
<br /> i
<br /> �:
<br /> L ,�
<br /> I• ;I �. .�
<br /> ' i � z �
<br /> � � s
<br /> NOTE: SHEATHING NOT ' ; ` ' �
<br /> �. �I I. •I s
<br /> SHOWN FOR CLARITY $ C�
<br /> � (' I (• ,I ' � _ GIRDER TRUSS ABOVE `
<br /> PPER 18'-9» , . � — — — — — -- — — — — — — — — �"� _
<br /> .
<br /> , , »
<br /> �
<br /> �
<br /> . - — — — — �
<br /> �. �, — —�'=8'=R.4— — — — — — —1--- i � ` � L f ,
<br /> �
<br /> z ;.�.. .. , ..�^'�,� � . 5�
<br /> III IVI IUI II(ill IIIIIIIIiI IIII IIiI IIII IIII IIIIUIUI lll I�.I .� Iill llll Illl ;I4 MST P�R PLAN ^
<br /> P�AN �
<br /> - - - -- - - - - - -
<br /> ,>��i i��i ifir �f�ii� ini�ifii ini i�i� ini u�� i���t�ini in t i �i ir�i ini ii�i ,,i. �
<br /> PLATE 17'-11 ' ' SHEARWALL � N �
<br /> �. . i
<br /> . . . . . . . . . . . . ,. . . . . . .
<br /> . . . � ��
<br /> ;.o ,o �
<br /> I (. .I I, •I TECH RM � � — � — � — � � — � ' �° �t� c
<br /> I' .) (• .� 20'-0 3/4" ti r���
<br /> � . �- . . . . . . = T -._. �. - '�,
<br /> I• :i �. •� o — �� � .
<br /> a
<br /> � 6X6 � �, � ,�
<br /> ' ' ° � w . _ o
<br /> ° . I'`� • - a
<br /> �°' — __Y_� — �,�?�y � ,���
<br /> . : � • � � �
<br /> � � UPPER 18'-10'� " • : ��,�
<br /> i
<br /> ° , PSL 3.25X9.25 CONT.
<br /> ( - ' � PLATE 18'-0" i�.�.� r'.�.•. ' �`�`� � `� �
<br /> �.� �"":"`., �:"'s`, i. r. �3
<br /> � ���� � �J 6X6 '�� •o` ti.� _ � C9 z �
<br /> � \ � �
<br /> � Q N � N
<br /> I I ( aoe 7 a � O N �
<br /> I � f I I I .� 59.3 • � .
<br /> 1 i — � � � . � �
<br /> II I I ) II I ) I ) � �
<br /> , I I ��-o° R•�•I I I _ �
<br /> ...
<br /> - n �
<br /> � - _ MST PER PLAN MST PER PLAN CONT. DOUBLE TOP PLATES o
<br /> I II II , I I I �
<br /> S�A�E: 3�4�� '� °�� D E TA I L A T U�1 T E 3 TE C N R M�B D R�1 F�L 0 0 R LTP4 � 10�� � o 0
<br /> 0 �
<br /> � o
<br /> � a
<br /> � �, ,.
<br /> , ;
<br /> 2'-2" 8'-&" �
<br /> 2'_�„ 1�_��� ��_g�� I w
<br /> � �
<br /> Q �---
<br /> f- ..
<br /> � Q .
<br /> _ _ _ _ _ _ _ PSL 3.25X9.25 CONT. _ _ _ _ _ _ � � v
<br /> — — — — �
<br /> � — — — — — — — — — — — — — — — v'
<br /> �
<br /> MST PER PLAN 1'-6" 7'-0" R,O. 1'-6" �
<br /> POWDER ROOM i U, � �
<br /> i MST PER PLAN FLOOR FRAMING MST PER PLAN z � F-
<br /> _ o �
<br /> � . — — — — — — — — —
<br /> P�A�1 - - - . �
<br /> - , .
<br /> i. .i ,2 , � o , W
<br /> � �, e� s�.3 - - - - - - � � —. — - -.
<br /> SHEARWALL
<br /> MAIN 8`-11" J �I PWDR RM
<br /> _�. AN
<br /> � i� 10'-1" -
<br /> VI / I�ll / Illl � Iilllll f llillillll �� Illl �� IUI �� Illl �� IUI � 11�1111 � IIIII�J �) �� Illl �� IUI �� IVI !111111 ''' � � � — � \
<br /> � _
<br /> , lli / Ilif / IIII � Illllll � 1111111111 � Illl � Illl � Illl � Illl � Illlll�lll � Illll�l =� � illl � Illl � �IU/ Illlll " � �.,.,
<br /> PLATE 8'-1' � /� �. .�. �.�.�. � �i�,�.�. � W�, ��,�.�� � .. . � ._. � � , i� � i ii 6X6 Q �
<br /> �. . . . . . ..�.�. •.•.•. '�'�' ' ' ' ' ' . . . _____ __�:'��-.�_.�"----. �. ���=-:_�� — _
<br /> _._�V� L�G_ ,1 � � w �-1
<br /> . . . ��•- � � � I( �1
<br /> . . . . . . . . . .
<br /> PROVIDE LAP FROM STRAPS . ''s , �-� 'Y � _�-i ii
<br /> Iv..Ie �r��_._ ` � f ! MAIN 8'-11 � �
<br /> ' ABOVE PAST PORTAL STRAPS i•'.� � � � I � # � � � �� � M �i
<br /> •� �, TO SWSB BELOW RE: � ' ' ' ' � i � i i �i 2X10 LEDGER
<br /> � . .o o. , ��..__�_____�.�_____.___�__�____�.�_ .��._�..e.___.�� �� ,
<br /> . . �
<br /> � • SCHEDULE, DO NOT NAIL OVER ' , �•�•�� ° � 1 ; i i�� '� �
<br /> ° • PORTAL STRAPS : . , . ': ! � _ � >_ „ a : . � O r
<br /> '°.o 0 0 0.°• g CONT. DOUBLE TQP a� o. � �----------- -�--------- -- ------� �� � PLATE 8 1 BEAM PER PLAN s . �
<br /> , . . . .
<br /> I I . LTP4 PER SCHED. �o o � � o o -�_-- � . '
<br /> . , . . . . . .
<br /> � _ _ ' . ' '_ `'�'�"• '; '•'� �
<br /> i . . 59.4 PLATES . �-�--_.�___.__- �
<br /> � � i . . �.
<br /> ,o• I I •o. FURR DOWN TO � 1 � g 1 . . . . . . . . . . . . . . . . . . �
<br /> . . . . . . . . . . . . . . . . . . . . . . . .•
<br /> PSL 5.25 X 16 � � ` �
<br /> � � U.N.O. PER PLAN DOOR R.O. �� � �' � j � S9.4 � � .
<br /> - �
<br /> i BEAM PER PLAN ^
<br /> � ���.A�
<br /> � HDU PER PLAN �
<br /> � � �
<br /> � , �
<br /> , , MST PER PLAN CONT. DOUBLE TOP PLATES CONT. DOUBIE TOP PLATES !
<br /> � , SCALE: 3/4" = 1'-0" �
<br /> 'L J ' 12 DETAI� AT U LTP4 C� 10��
<br /> � � , 0 NIT E3 PWDR DIN NG F�OOR ,
<br /> � / I �
<br /> , ,
<br /> _ ' o
<br /> � �,
<br /> _ � �
<br /> r i � _ _ _ _ _ - _ _ _ _ _ � _ _ _ _ _ _ _ _
<br /> r � r � r �
<br /> � . — ._ � T _ T — _ _.,— ..— _ _ .� .._ — ` , - - - - - - - - - - - -�- - - - - - � � , � � � a . . . - - - - -,- - - . - - - - - - .. -.- - _ _.__ —� - - - - • !� .
<br /> • T..i
<br /> r � �
<br /> .., — f � - - - - - - -
<br /> I � I - - - - -- - - - - - - - - - - - � .. .. ... . . . . - - - - - - - - _- - - - - - - - - - - - - _ - - J .
<br /> 4 �
<br /> - 2=6" - - - - 5 0" R.O. 3r 6,> i .
<br /> — � — � � T � T _ T � —._ — — .�, _ � _ � .�
<br /> � z � �
<br /> . f � BEAM ABQVE PER PLAN o �
<br /> ( — — — — — � � � �
<br /> r � r � r� � r -i r- � r -i r � r -i r- � N �
<br /> ( ( —� �
<br /> L L J L J L J- - L - -L J J L J �
<br /> �
<br /> � __ � - _
<br /> SWSB PER PLAN SWSB PER PLAN i � ' � ; i � P�A N 3 PROVIDE BLKG. AND � �
<br /> ( :.. i .. :: :: 9 � � I { � I 2'-3" 5'-0° STRAPP NG PER 8/S1.3 3'-3" 1'-3" � � •r-+
<br /> � ... .. i . � , � � i � � �, .-L�
<br /> :: � :: A.BOLTS PER SBA-3 f S1.4 A.BOLTS PER SBA-3/S1.4 ;: ::: � � I � � $ � i - S EARWALL PER PLAN � �^ � �
<br /> ` C�
<br /> I �� .. � :: i � � � ; _ -- - _ - 1 PLAN �
<br /> � � II � 11 ( �
<br /> � ;
<br /> GROUND 0'-0"� �� ;: i ,..-i �_�_�.�__. 6X6 - - - _ _ _ _ _ - - - -_ � +-�
<br /> o ; �
<br /> ' '.o._--_ � -- -- 9» � ��� 1 �, „ 1, 4„ �, 4„ � o e �
<br /> I ABU66 z 1' 1'-4' 10° 8" 9"
<br /> � . . . . . . . v o N � � � .
<br /> � � , „ �� _ 1 N I �, � � ry
<br /> � ^ � GROUND 0-0 �� � •+� �� ' � W
<br /> � - - - - - - - - - - - - -
<br /> iii iii o yi qi iii ii� qi iii iii yi qi iii {{{
<br /> II II 1 I II II II II I! il kl Il I( II _ i � _
<br /> I •
<br /> - - - -II - - - - i - - - -Il - - - -
<br /> T �N T E GARAGE E�lTRY 4 � — ;p — �- - -�� - - �� �� �- - - - �� �� �- - �'� — � ;�,
<br /> SCALE: 3 4" = 1'-fl° - - - - - - � MUDSILL/ANCHOR BOLTS PER i0! i ��
<br /> � � �-- � SHEARWALL SCHED. �
<br /> � _ � — � � T — — T — — — � � ^ _.__ —.. — i SCALE: 3/4" = 1�-0" i i
<br /> � � AA gg }5 14 13 '
<br /> S9.� 59.� 16 59.3 59.� DETAI� AT U�11T E3 E�lTRY BDR� �OUNDAT 0�1 S9.3 •
<br /> �
<br />
|