My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3500 TERMINAL AVE 2018-06-08
>
Address Records
>
TERMINAL AVE
>
3500
>
3500 TERMINAL AVE 2018-06-08
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/8/2018 2:22:58 PM
Creation date
6/8/2018 2:22:33 PM
Metadata
Fields
Template:
Address Document
Street Name
TERMINAL AVE
Street Number
3500
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
223
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
HD Fowler Company Submittal -Bid Item#27 <br /> ROMAC INDUSTRIES, INC. <br /> ROMAGRIP <br /> MECHANICAL JOINT RESTRAINING GLAND <br /> 3 THROUGH 12 INCH <br /> SUBMITTAL INFORMATION <br /> USE The Romac RomaGrip restraining gland is used for the <br /> restraint of mechanical joint ductile iron pipe, valves, fittings, and fire <br /> hydrants in water transmission and fire protection lines. It may also <br /> be used on IPS sizes steel pipe(minimum thickness STD weight <br /> class pipe)with MJ by IPS transition gasket.The RomaGrip replaces <br /> costly concrete thrust blocks, corrodible steel tie rods and clamps. <br /> Not for use on plain end mechanical joint fittings. The RomaGrip may <br /> be used on cast iron pipe as long as it has the same OD as ductile <br /> iron pipe. <br /> Note: Some initial axial movement may occur in lug style restraints as the lugs seat. Movement is directly <br /> related to the size of the piping system and the system pressure. In general terms movement of <br /> approximately 0.25 can be expected in restraints under 16". For larger sizes, movement of <br /> approximately 0.40 may be seen. If this is critical to your application please contact Romac <br /> Engineering for additional information. <br /> MATERIALS <br /> Gland Ductile (nodular) iron, meeting or exceeding ASTM A 536-84, Grade <br /> 65-45-12. <br /> Gaskets A standard MJ gasket is used with this fitting. <br /> Meets ANSI/AWWA C111/A21.11 for gasket specs. <br /> Restraining Bolt 7/8—9 roll thread, Ductile (nodular) iron, meeting or exceeding <br /> ASTM A 536-84. <br /> Restraining Lugs Ductile (nodular) iron, meeting or exceeding ASTM A 536-84. <br /> Heat treated using a proprietary process. <br /> Lug Locators Polyurethane, a thermo-set plastic. <br /> Coatings Shop coat applied to the casting for corrosion protection in transit. <br /> Epoxy coating optional. <br /> PERFORMANCE <br /> Nominal Number of Approx. Working Test Maximum <br /> Pipe Restraining Weight Pressure Pressure Joint <br /> Size Bolts (lbs) (psi) (psi) Deflection <br /> 3 2 6 350 700 5° <br /> 2 7.5 350 700 5° <br /> 6 3 11 350 700 5° <br /> 8 4 16.5 350 700 5° <br /> 10 6 23 350 700 5° <br /> 8 29.5 350 700 5° <br /> FM Approved FM approved for cast iron and ductile iron pipe at 175 psi working <br /> pressure (4 : 1 test). <br /> UL Listed UL listed for cast iron and ductile iron pipe. <br /> Document Number 05-8-00 6/14 <br /> This information is based on the best data available at the date printed above,please check with Romac Engineering <br /> Department for any updates or changes. <br /> Phone (425) 951 6200 • Toll Free 1 800 426 9341 • Fax (425) 951 6201 • www.romacindustries.com <br />
The URL can be used to link to this page
Your browser does not support the video tag.