My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3500 TERMINAL AVE 2018-06-08
>
Address Records
>
TERMINAL AVE
>
3500
>
3500 TERMINAL AVE 2018-06-08
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/8/2018 2:22:58 PM
Creation date
6/8/2018 2:22:33 PM
Metadata
Fields
Template:
Address Document
Street Name
TERMINAL AVE
Street Number
3500
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
223
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
HD Fowler Company Submittal-Bid Item#27 <br /> SPECIFICATIONS/AVAILABLE CONFIGURATIONS& STYLE NUMBERS (2"-20") <br /> M&H AWWA C515 RESILIENT WEDGE GATE VALVES (2000) <br /> M&H Valve AWWA C515 Resilient Wedge Gate Valves <br /> Meet or Exceed the Requirements of AWWA Standard C515 <br /> Size Range Water Working Bubble Tight Hydrostatic Shell <br /> Pressure psi Seat Test psi Test psi <br /> AWWA 2"—20" 250 Water Works 250&400 500 <br /> ULFM 4"—16" 200 Fire Protection 250&400 500 <br /> Style No. Style No. Style No. <br /> Available End Connections(No Gear) Size With With With <br /> Range 2"Nut Hand wheel Post Plate <br /> Mechanical Joint(NRS) (no 2'/2") 2"-16" 7571 7571-HW 7571-P (3"-16") <br /> Flanged Ends(NRS) 2"-16" 7561 7561-HW 7561-P (3"-16") <br /> I Flanged End X Mechanical Joint(NRS) ( 3"-16" 7572 7572-HW 7572-P (3"-16") <br /> Push-on (NKS)(For PVC/SDK) 2"-12" 7597 7597-HW 7597-P (3"-12") <br /> Threaded(NRS) 2"-3" 7057 7057-HW 7057-P (3"only) <br /> Threaded(NRS)(With T-Head Nut) 2"-3" 7067-07THN(With T-Head Nut) <br /> ***Threaded(OS&Y) 2"-3" N/A 7067 N/A <br /> Tyton X Tyton(NRS)(For D.I./C900) 4"-12"&16" 7901 7901-HW 7901-P(4"-12"&16") <br /> Tyton X Flange(NRS)(For D.I./C900) 4"-12" 7902 7902-HW 7902-P(4"-12") <br /> ***Flanged Ends(OS&Y) 2"-16" N/A 7068&7068A* N/A <br /> **Tapping Valve(NRS) 4"-16" 7950 7950-HW 7950-P (4"-16) <br /> M.J.Cutting-in Valve(NRS) 4"-12" 7576 7576-HW 7576-P(4"-12") <br /> ****Flanged End(Open Mitre Box) 3"-12" 7211-0 7211-O-HW N/A <br /> ****Flanged End(Enclosed Mitre Box) 4"-12" 7211-C 7211-C-HW N/A <br /> Style No. Style No. <br /> Available End Connections(Bevel Gear) Size With With <br /> Range 2"Nut Hand wheel <br /> Mechanical Joint(NRS) 14-20" 7571-B 7571-BHW <br /> Flanged Ends(NRS) 14"-20" 7561-B 7561-BHW <br /> Flanged End X Mechanical Joint(NRS) 14"-20" 7572-B 7572-BHW <br /> Tyton X Tyton(NRS)(For D.I./C900) 16" 7901-B 7901-BHW <br /> Flanged Ends(OS&Y) 14"-20" 7068-B 7068-BHW <br /> **Tapping Valve(NRS) 14"-16" 7950-B 7950-BHW <br /> Style No. Style No. <br /> Available End Connections(Spur Gear) Size With With <br /> Range 2"Nut Hand wheel <br /> Mechanical Joint(NRS) 14-20" 7571-S 7571-SHW <br /> FlangedEnds(NRS) 14"-20" 7561-S 7561-SHW <br /> Flanged End X Mechanical Joint(NRS) 14"-20" 7572-S 7572-SHW <br /> Tyton X Tyton(NRS)(For D.I./C900) 16" 7901-S 7901-SHW <br /> Flanged Ends(OS&Y) l4"-20" 7068-S 7068-SHW <br /> **Tapping Valve(NRS) 14"-16" 7950-S 7950-SHW <br /> Note: 2"to 3"sizes full wall ductile iron(per AWWA Dimensions) <br /> *7068A is Tapped&Plugged in"A"Position (2"—4" =''A"tap)(6"—12"=3/o"tap) <br /> **Each size accommodates a full size diameter tapping cutter.. OF <br /> `l <br /> °""° ***2"OS&Y Flanged and Threaded versions are UL Listed <br /> ****All other end connections available. <br /> •U' 4 18"and larger RS gate valves will be furnished with either bevel or spur gearing. <br /> Corded to <br /> MEMBER ` By-pass valve not required on gate valves through 24" / 1G <br /> NOTE: It is recommended that valves be installed with stems vertical when used in <br /> raw sewage or sludge applications or in water with excessive sediment. <br /> Sizes 2"-12" <br /> September 1, 2012 / C515 Gate Valves <br />
The URL can be used to link to this page
Your browser does not support the video tag.