Laserfiche WebLink
GENERAL NOTES <br /> THIS ELECTf�lCAL PLAN IS THE ARCH(TECT'S SUGGESTED LAYOUT. THE <br /> ELECTRICAL, CONTRACT IS ON A DESIGN-BUILD BASIS. ELECTRICAL <br /> CONTRACTOR'S DESIGN SHALL BE APPROVED BY THE OWNER AND SHA�L <br /> CONFORM TO THE APPLICABLE ELECTRIC CODE REGARDLESS OF WHATIS <br /> SHOWN ON THIS DRAWING. <br /> � � , <br /> � METER CENTER LOCATIONS SHA�L BE CDORDINATED WITH THE ARCHITECT. <br /> � �: � <br /> HIGHEST OPERABLE PART OF ENVIRONMENTAL AND OTHER CONTROLS SHA�L � _ � � � �; � � �, � ', � �; � � <br /> MOUNTED NOT LESS THAN 36 INCNES ABOVE FLOOR. ELECTRICAL AND / \ <br /> COMMUNICATIONS SYSTEMS ON WALLS SHALL BE MOUNTED A MIN. OF 15 �[ �,, � � j� � � � � � <br /> ti <br /> INCHES ABOVE FLOOR. _____�TO PHOTOCELL T <br /> �-� � �� � ' � <br /> QU TLETS, SWI TGNES, TELEPHONE AND TV, ETC. BOXES IN PAR TY WALLS 0� .,,.._._,._..__ � L______________________L__ <br /> I � ---- � � �� �� C�ntraF Wdy, Sur#e�=i�� <br /> ONE UNIT SHALL BE IN DIFFERENT STUD SPACES THAN THOSE IN OPEN I � ��,�����,�p,�������� ����� , <br /> I <br /> THE ADJACENT UNIT. NO TWO ADJACENT UNITS SHALL HAVE SUCN BOXES � I � � � I ' / � ������ ���� �f ���� }�� <br /> SPACE � � ( � � I � � � ' <br /> IN THE SAME STUD SPACE. BOXES SHALL BE SEPARATED HORIZONTALLY TOP NALF ' 1000W ELEC �.� � � , <br /> BY 24��. TV 1000W ELEC — i CEILING HEATER I <br /> , t �.� � � � � ; �C��1 1�t�'�±,t�i���C�iC��CfttC�� t4i1� ; <br /> CEILING HEATER � � I � � ,. — — — — � \ � I \ ` �. I I <br /> / �L � � �.\ � I <br /> INDIVIDUAL ELECTRICAL OUT(�ET BOXES SHALL BE OF STEEL OR OTNER �.�� � <br /> APPROVED MATERIAL AND SNALL NOT BE GREATER THAN 16 SQUARE � � TV I i <br /> Mas�er Be,:�room E `I � , , <br /> INCHES 1N AREA. � CEILING FAN Liv�ng � �� SMURF � � � � I 5052 REGISTERED <br /> THE WATER HEATERS SHALL BE STRAPPED PER IRC P2801.7 AT A POINT j i� CEILING � j RATED BOX 1 � ��TUBE I � <br /> � ARCHITEGT <br /> � i FAN RATED I � �� � � � I � <br /> WITHIN THE UPPER 1/3 AND TNE LQWER 1/3 OF ITS VERTICAL DIMENSION. � � g�X I � } � � i �� � PREWIRE LOW � � <br /> THE LOWER STRAP SHALL BE NOT LESS THAN 4° A80VE ANY CONTROLS. I � <br /> WATER HEATERS SHALL BE PROVIDED WITH A PRESSURE/TEMPERATtIRE I j/ �� i � � �'` I ; ; j AT VOLTAGE WlRE j <br /> � ' ' { I CEILING� FOR GARAGE I � ROBERT E. WEIBL� <br /> I ' ' DOOR OPENER I STATE OF WASHINGTON <br /> IEF VALVE THAT IS CONNECTED TO A DRAIN LINE. THE DRAIN LINE / � �.� I I <br /> SHALL BE DIRECTED TOWARD THE GROUND AND TERMlNATE AT A POINT NO � j �� , � � TV & OUTLET j � ( I � & LEC. EYES <br /> LESS THAN 6" ANQ NO MORE THAN 24" ABOVE THE GROUND. 1 j � 1 i 72 OF� FLOOR � / , I <br /> � / � � j I <br /> SMOKE DETECTORS SHALL BE EQUIPPED WITH A BATTERY BACK-UP SHALL I � �� i i j � - - - " � ' I % <br /> EMIT A SIGNAL WHEN BATTERIES ARE LOW, SNALL BE PERMANENTLY HARD � � M I N! P E N D � � � � � <br /> WIRED AND WITHOUT A DISCONNECTING SWITCH OTHER THAN THOSE � � ! STACK ' � ANT I � � I � <br /> ---- -- ------- --------- -- °' <br /> REQUIRED FOR OVERCURRENT PROTECTION, AND SHALL SOUND AN ALARM � TRACK LIGHT ' � �. - �:---- �=--- - --------.-- ----r-------. - � > <br /> � <br /> � -r_-.�. . . . . <br /> • <br /> � � � THERM. & � �1 .� . . . . . . .. . . �. �. . . i I � <br /> � , <br /> , � . �_ __-- ara e : ,. , <br /> AUDIBLE IN ALL SLEEP(NG AREAS OF THE DWELLING fN WHICN THEY ARE Linen I � � � SWITCH ' SOFFIT AB�VE T _'_______'_'_ _I <br /> LOCA�fED. ------------ --, -- �----�----------+-_-:_---=-- �, <br /> � T o � � ----- --------- � � ELEC T j / <br /> . . . . . <br /> - -- -------------------------- <br /> 3 3 S T A C K ' ; � i PANEL � � � � � <br /> I I I — <br /> I — <br /> Y N TES T . <br /> 3 3 ----------- --- ---- -------- —————-�—r� ' � <br /> � � o � I � r � <br /> THERM. & ' — � ' :..i _ _.— —.—.— — � TELfI-46 � II ( I I � <br /> SEE ENERGY NOTES ON SHEET A1 & D5. / � SWITCHES _ � <br /> � l I � <br /> `.. t � _� � � i i � � I II I I I . I <br /> W A T E R H E A T E R S H A L L B E F U E L E D B Y G A S A N D H A VE A MINIMUM EF OF i \ i �� '" � ' _. f I � � � � � I I i I � � � <br /> � . <br /> 0.�2. ' M. Bat� ` � i � � � i ii i i ';i i ' z <br /> � _LJ I i <br /> I � I � O N <br /> _,\ � <br /> NOT ANQ COLD WATER HEATER PIPES IN UNCONDITIONED SPACES SHALL BE 1 `� ao r I . .I 750W ELEC ' ��� / I �1 � I _ <br /> ' .i CEILING HEATER � 4 ISP. O i ----- i � <br /> � INSULATED WITH R-3 INSULATION WHICH HAS A FLAME SPREAD OF 25 OR � o o � � � <br /> LESS. T� R � � � <br /> � � - ' I � � �. � 3 9 � , <br /> C1RY W.H. � � i �.�i ' I , o <br /> � i <br /> \ � , i a <br /> VENTILATION NOTES ' � I ` � � ' � � Kitchen` ' � PB -� <br /> FAN <br /> � � VTR � ° I � �.�.�{�-�; 1 � � I I p � ; <br /> � i � .i � I i i�DW\ f� -f-14-6 ' TO � o DC�t� � � i i � <br /> � I � (I � <br /> VENTlLATION: SEE NOTES ON COVER SHEET. � � ABOVE . Q � <br /> WkSHER r----�� -.- ` i l.'.; I i i� � / I � i I ^ <br /> TO I ' � � � / j � � N <br /> ALL EXHAUST DUCTS SHALL BE RIGID METAL, AND SHALL BE FITTED WITH A � � � F � ; � � ��-- �"' I I ` o � o i � � <br /> NOT IN �USE.G BACKDRAFT DAMPER CAPABLE OF CLOS(NG WNEN THE FAN !S BELOW �/j Bat VTR �� � � <br /> T L--� . .i i ; -N46 i l ° 1 i a .a' <br /> ', ( / � � � a � o / � � <br /> -------- <br /> f 350W ELEC SD ( � <br /> � <br /> DUCTS IN UNHEATED SPACES INCLUDING ATTICS SHALL BE INSULATED TO A S� i � C � - - - - , ' BASE OARD <br /> MINIMUM OF R-8. � � C j i o O <br /> � -_____:�__________________________________ / z <br /> -------------- <br /> / <br /> � - � �. CHIME � � ' � i , <br /> T O P F L O O R E XHAUST FANS SHALL VENT THROUGH ATTIC. � \ ^ _ i � /Ent � , <br /> % So _�___ � �, - 0 <br /> � � � ' � ` � T T STACK \ ` I � � co <br /> DRYER EXHAUST DUCT SHALL BE 4" RIGID METAL WITH A 4" OPENING ON TEGH y i � � <br /> THE EXHAUST HOOD. TNE DRYERS DUCTS SHALL BE GALVANIZED STEEL OR � � � OVER <br /> ALUMlNUM, MINIMUM 0.016" THICK. THE DRYERS SHALL BE GENERAL PORT TECH ' � r <br /> ELECTRIC. DRYERS SHA�L BE INSTALLED ACCORQING TO MANUFACTURER'S T �� � �� Din./Fam. I � � 4 PORT SWITCH � W � N <br /> � Bedroom \ , , o � <br /> I N S T A L L A T l O N l N S T R U G T(O N S O N S I T E. 6�-8�� I i 1 I Bedroom <br /> Tech � f � <br /> WINDOW OUTDOOR A!R INLETS SHALL PRQVIDE THE E QUIVAL E N T O F 4 S Q. � <br /> E . . . . . <br /> IN. OF NET FREE AREA. � � I <br /> 750W ELEC <br /> CEILING HEATER ��r•'.". ."l . . . P I � <br /> � � � � <br /> � ��- F :�. � I CEIL5NG HEATER � <br /> . � , � M Z � <br /> � <br /> � <br /> 1004W ELEC i f000W ELEC � I I <br /> CEILING HEATER in I W J o N <br /> CEILING HEATER Q , <br /> TV � �-------- <br /> �ATH � � a �' <br /> FAN i I " o <br /> I � <br /> i J <br /> �--------------------� Q <br /> M c� <br /> W � T � <br /> � m � <br /> TRICAL LEGEND . „ v � � <br /> Q W o � <br /> 0 <br /> � DUPLEX RECEPTACLE OUT�ET DIRECTIONAL CEILING M W <br /> � DUPLEX RECEPTACLE OUTLET MOUNTED UGHT UPPER LEVEL MIDDLE LEVEL LOWER LEVEL �`+ <br /> U N 1 T E3A E3 B E3 C & E3 D ELECTRICAL PLAN U N 1 T E3A E3 B E3 C & E3 D ELE�TRICAL P W <br /> SPLIT WIRED (SWITCH TOP HALF) � CEILING MOUNTED LIGHT 1 1 'l— � " � j �N U N 1 T E3A, E3 B j E3 C & E3 D ELE�TRICAL PLAN o <br /> M� DUPLEX RECEPTACLE OUTLET 1�4"=1'-0" 1�4 —1 —0 � �_ �_�� � � <br /> MICROWAVE — � � <br /> � a 11 <br /> RECESSED CEILING L(GHT; , <br /> IC RATED - SEE 12/D1 ` <br /> � SINGLE RECEPTACLE OUTLET � � et <br /> 2Q8v (R: RANGE, D: DRYER) WALL MOUNTED LIGHT r <br /> � � <br /> Q JUNCTION BOX <br /> C�'`='-� DOUBLE TUBE FLUORESCENT � <br /> � TEGN PORT CEILING MOUNTED LIGHT � <br /> TEL.� TELEPHONE JACK �- CEILING MOUNTED TRACK LIGHT � <br /> � <br /> TV TELEVISION JACK H � HEAT LAMP, EXHAUST FAN � � <br /> � SINGLE POLE SWITCH COMBfNATION RECESSED CEILING O � <br /> FIXTURE - 250W LAMP, 50 CFM <br /> �3 THREE WAY SWITCH MIN., 3 SONES, 4" ROUND DUCT. <br /> � � <br /> SEE 15/D1 � � <br /> DIMMER SWITCH BEARING WALL - SEE NOTES > � <br /> DIM.� �azs�s:;s��dr� � � O <br /> T TIMER SWITCH THIS SHEET REGARDING BOXES <br /> � AND FIRE-RATED WALLS W 0 �,�,, U <br /> t!� � _ � <br /> � RECESSED CEILfNG EXHAUST FAN � METER CENTER = N <br /> 50 CFM MIN, 3 SONES MAX, � � y � <br /> 4" ROUND DUCT. SEE 15/D1 �� ELECTRICAL PANEL — Q � � <br /> eeH ELECTRIG BASEBOARD � � � � <br /> � MICROWAVE OVEN/RANGE HOOD � � � � <br /> LMw-� COMBINATION, 100 CFM, 3 SQNES NEATER <br /> SMOOTN DUCT. OT THERMOSTAT � � L � <br /> � RECESSED HEAT LAMP - � SMOKE DETECTOR <br /> ��t�� NUTONE 9410H, 250W LAMP WITH BATTERY BACKUP <br /> W p � Z <br /> CEILING FIXTURE. SEE 12/D1 � � (j� O <br /> CARBON MONOXlDE .— � <br /> � PHOTOCELL SAFETY SENSQR ALARM/SMOKE DETECTOR = <br /> O AUDIBLE SPRlNKLER � <br /> ❑ TECH PANEL � FLOW ALARM � O <br /> 0 RECESSED CEILING WHOLE � n' <br /> � HOUSE EXHAUST FAN ��y.. W�NDOW WITH OUTDOOR � <br /> �F 80 CFM MIN., 120 CFM MAX., NLET <br /> � <br /> 1.5 SONES, 6" ROUND DUCT �PB PUSH BUTTON � <br /> VTR VENT THROUGH ROOF <br /> � � <br /> 0 1ob No.: 13-47 <br /> � <br /> � <br /> r Sheet No.: <br /> z <br /> � U9�v <br /> sheer order: A B U F R E S D I � <br /> _ <br />