Laserfiche WebLink
E3 UNIT VARIATIONS <br /> A - BASIC PORCH/ NO POPOUT AT REAR <br /> B - BASIC PORCH/ POPOUT AT REAR <br /> C - ENHANCED PORCH/ NO POPOUT AT REAR <br /> D - ENHANCED PORCH/ POPOUT AT REAR � <br /> SEE BUILDING PLANS FOR WHERE <br /> VARIATIONS OCCUR ,� <br /> � <br /> �, > <br /> � � � � r � �1 � � �; <br /> INSU TION '� _� � � [' � � C �' S <br /> LA ��� �,� �� <br /> FOUNDATIQN PERIMETER - R-10 R[GID ' <br /> INSULATION TO A DEPTH OF 24" OR TO TOP ��������� ���` ���#� ��� <br /> OF FOOTING AT HEATED PER(METER <br /> ;��r�l�er��r`1��t��t�t�fo�i 98(l�� ; <br /> WALLS: 2x6 WALLS WITH FIBERGLASS BATTS F `� ���������� � ����� }��� <br /> OR BLANKETS - R21 `������������r����������� : <br /> FLOORS OVER UNHEATED SPACES - R-30 <br /> ATTICS AT TRUSSES - R-49 <br /> (R-38 SNALL BE DEEMED TO SATISFY TNE 5052 REGISTERED <br /> REQUIREMENT OF R-49 WHEREVER THE FIJLL � ARCHITECT <br /> HEIGHT OF UNCOMPRESSED INSULATION EXTENDS � <br /> OVER THE WALL TOP PLATE AT THE EAVES) <br /> ROBERT E. WEIB�E <br /> EXTERIOR DOORS: DOORS BETWEEN HEATED <br /> STATE OF WASHINGTON <br /> AND UNHEATED SPACES SHALL BE U=0.3Q <br /> OR BETTER <br /> WINDOWS: ALL WWDOWS AND SGD TO HAVE — <br /> U-FACTOR aF U=0.30 OR BETTER -a <br /> � <br /> > <br /> INSULATE UNDEft STAlRS AND !N WALL �; <br /> CAVITIES ABOVE BOTTOM OF STRINGERS i �' <br /> � <br /> � <br /> � <br /> � <br /> .� <br /> GYPSUM WALLBOARD SCHEDULE � `r <br /> �; <br /> %a" GYPSUM WALLBOARD (GWB) SHALL BE � <br /> USED THROUGHOUT ON INTERIOR WALLS, � <br /> INTERIOR SIDE OF EXTERIOR WALLS AND <br /> CEILINGS EXCEPT AT EXTERIQR WALLS AND v <br /> COMMON WALLS REQUIRED TO NAVE A 1-HR a' <br /> OR 2-HR FIRE-RESISTANCE RATING IN � <br /> WHICH CASE %a" TYPE 'X' GWB SHALL BE � <br /> USED. a <br /> � <br /> � <br /> M <br /> 0 <br /> � <br /> .� <br /> � � <br /> � � <br /> a <br /> � � �. <br /> � � <br /> 0 <br /> v <br /> I z o <br /> � <br /> M � � <br /> w � � <br /> �' N <br /> a� , <br /> c e- <br /> � � <br /> � <br /> � � <br /> � <br /> � <br /> W Z � o <br /> s N <br /> c � <br /> a � <br /> n � <br /> � � <br /> M � <br /> W ° <br /> O T � <br /> m <br /> � J o �' <br /> � �.�. o � <br /> 0 <br /> M <br /> W <br /> N o <br /> �, � �- <br /> .� a u <br /> � �, _ <br /> � <br /> j '��� C� i � � �� ABOVE. MIN.3¢" GWB APPLIED TO <br /> Z � : � ' � ALL WALLS, BEAMS, AND POSTS � <br /> � N N z : i � �I ( I WiTHIN GARAGE. <br /> Q � . . . i ii ;� � <br /> ; z , ,�—__ � � Carag� <br /> � <br /> � � ; I � I � 16 � � � � <br /> E..: . . i i i I (' D3 SIM. � 4'—i' s'-2l'Z" 9'-9Yz' � �, <br /> � z � i l � � _ <br /> v¢, Q � ,� .---- . . .�:�. . . . . . ,----_-------- � � � L --=;:�: � G� <br /> �� , , � .... . .. :... .. � <br /> : <br /> . . .. ... .. .. . ... <br /> ^ <br /> __��_,� _ -__ �_, __ . <br /> .. <br /> . -_-- -- <br /> -__. <br /> . -- ---- --------------------------- --- <br /> N O T E S �� � �� i _—_ I INSULATE SOFFIT AROUND BEAM <br /> ' �. �; 10 ��2 ;N OFFlT 16 OFF CEILING 2> 8>: , -- �STAIRS AND BATH EXHAUST 8 � � � <br /> FRAMlNG: 2x6 s AT EXTERIOR WALLS THE FIREPLACE SHA�L BE LlSTED SY UL. OR FM AND _____�� D5 � a O � <br /> SHALL BE INSTALLED IN ACCORDANCE WITH TNAT CONTWUE COMMON WALL � ;, I I � � <br /> 2x4's AT iNTERIOR WALLS \ N C° 2 2 i� �� � ' :r I I o, ' <br /> UNLESS NOTED OTHERWISE. LISTWG ; �-- D� � � , -� � � <br /> SEE S1.1 FOR STUD SCHEDULE. � a : p5 GWB THROUGH TYPICAL j� � 5 - 1� ' s 3 <br /> R-21 BATT (NSULATION PROVIDE WATER RESfSTANT GYPSUM WALLBOARD : SiM. - �"""" '� uP D2 D2 Dt � <br /> 3. . . . . . . . A+ <br /> '""""""""' � BENIND TUB AND SHOWER ENCLOSURE MATERIALS e = i� �N siM. � �� � , W <br /> ...... .. <br /> ------ .t►-i. . . . . . . . . . _ . SQFFIT � 1 ..O�, = 4 <br /> .- . ° : . <br /> 3/2" ACOUST. INSUL. EACN SIDE Tp A NEfGHT OF 70" MINIMUM ABOVE THE : � � � � p� : o• N " "' "' m�� ' m W 0 ��.+ U <br /> ti <br /> Din /Fam � � � , �, <br /> OF PARTY WAL.L, UNO. DRAIN INLET. � <br /> 7 -10 A.F.F. I � � � ��z� w �� � �, N � �s �a � <br /> p`�, �+ i LOW WALL A7 ; � <br /> N 1 .Y.Y�1 i, . . . . X ' � ti8" ABQVE : o �Z � � N� � Bath � o s�M. G� � <br /> CONCEALED SPACES SHRLL BE FIRESTOPPED IN BOTH NQ PLUMBWG MECHANlCAL EQUIPMENT DUCTS OR � 24 T8 � � NOSING. RAILING � o N , � N � <br /> r . � . � � i� tv I 24'TB <br /> DIRECTIONS AT 10'-0" ON CENTER ANQ AT FLOORS. VENTS SHA�L BE LOCATED IN THE COMMON UNIT I � neov� ro +3s^ i o <br /> INSULAT� FLOOR OVER Z—g yC LOCATE PI <br /> TYPICAL. SEPARATION WALLS PER IRC SEC. R302.2 (EXCEPTlON) UNHEATED SPACE j �, ? � s ' o, ROUGN-IN � O � ^� <br /> t :'. . . . . .'TP. . . . . . , ...� z UP D5 � FOR (2) L � � i <br /> ALL ESCAPE QR RESCUE WINDOWS FROM SLEEPING ALL BEDROOM AND BATNRQOM DOORS SHALL BE �••••••••• -� •••••••••••••••••••••• ••••••••• � � Entry i AT COMMC � n � <br /> RQOMS SHALL HAVE A MINIMUM NET CLEAR OPENING 3 " ' : �-_s" 2�-°Yzr '�-3Y� � '�,' � <br /> UNDERCUT R MINIMUM OF /a ABOVE THE ADJACENT 1-6 ,2-6 F 7-0 5-0 DBL SL " R � � '�"' <br /> OF 5.7 SQUARE FEET. THE MINIMUM CLEAR OPENING FLOOR COVERING. � �� �, � � I "i ' '�g� � N U � � O <br /> HEIGHT DIMENSION SHALL BE 24". TNE MINIMUM CLEAR �° AT 6 -9 ABOV ; AT 8-0 A.F.F. ! N � /• � � L <br /> ANDI G F.F. :...... ....... :. ... Bedroom 3 , � O � Z <br /> OPENING WfDTH DIMENSION SHALL B� 20". SILL THE FRONT DOOR SHALL BE OPENABLE FROM THE � ��j , � � , s a ^ W > <br /> HEIGHT SHALL BE NOT MORE THAN 44" ABOVE THE I N S I D E W f T H O U T T H E U S E O F A K E Y O R A N Y S P E C I A L , � 2•_3 y2• 2�-,yz ; � � o, � W = <br /> FLOOR PER IRC SEC. R310.1.1. KNOWLEDGE OR EFFORT. 1T MAY BE PROVIDED WITH A ' " � I <br /> NIGHT LATCH, DEAD BOLT OR SECURITY CHAIN, , ' " � I Porch i � �o�� � � <br /> WHERE SILL AT OPERABLE WINDOW IS LOCATED MORE PROV(DEQ SUCH DEVICES ARE OPENABLE FROM THE � � � ;, nr s•-s'aF.F. '�' � <br /> TNAN 72 INCHES A80VE FINlSHED GRADE OR OTHER INSIDE WITHOUT TNE USE OF A KEY OR TOOL, AND � ' � �,,.�5'-63/4~ � z�e• � ����������� �� <br /> SURFACE BELOW SILL HEIGHT SHALL BE MINIMUM 24 MOUNTED NOT TO EXCEED 48" ABOVE THE FINISH�D � , >� �� � » � R � p, = O <br /> INCNES ABOVE FINISHED FLOOR. PER IRC SEC. 312.2.1. FLOOR. 2'-9" 2 -4 5'-0 5'-0 , "' �' - �— Dz I � O Q• <br /> 5-1" 2'-0" 10�-0" 2'-0" • � -- --- 1, iYs, � <br /> _ � � � <br /> ALL GLAZING SNALL CONFORM TQ IRC SEC. R308.4, STAIR NOTES: �g,_�» � �2 uP � <br /> HAZARDOUS LQCATIONS. GLAZING IN ALL DOORS SHALL LOCATE NANDRAILS AT 34'-38" ABOYE THE °s -- 5`-9'---.__ <br /> . BE SAFETY GLAZED. ALL GLAZING WfTHIN A 24" ARC STAIR NOSING. '-'y '��`"y4' Q <br /> OF EITHER VERTICAL DOOR EDGE SHALL BE SAFETY U N IT E3A & E3 B MIDDLE LEVEL PLAN <br /> GLAZED. ALL GIAZING WITHIN 60" OF A HAZARDOUS HANDRAIL GRASP DIMENSION SHALL BE BETWEEN 1" & <br /> GLAZED.N, OR "WET SURFACE" SHALL BE SAFETY fiER INATE ROVIDE C0�lTINUOUS HANDRAIL OR I 1/4"=1'-0" BUILDINGS 17 & 18 UNIT E3A & E3B LOWER LEVEL PLAN � Job No.: 13-47 <br /> 1/4"-1' 0" BUILDINGS 17 dc 18 W <br /> AT NEWEL POSTS OR SAFETY TERMINAL. SEE U�� FOR INTERIQR ELEVATIONS � SheetNo.: <br /> PROVIDE 5/a" (MIN.) GYPSUM SHEATNING ON ? <br /> WALLS BEHIND TUB/SHOWERS TO SATISFY F1RE WHERE USED AS A GUARDRAIL, A MAX. OPENING OF A N D I N T E R I�R S T A I R P L A N S � � � ■ � <br /> REQUIREMENTS AT UNIT SEPARATION WALLS CONDITION. 4��• � <br /> � <br /> SheetOrder: A B U F R E S D I � <br /> _ <br />