Laserfiche WebLink
r- -------------------------------------� <br /> � � <br /> HOSE j ❑ ❑ j ' <br /> BIBB� — — — — — <br /> I _� �. .` \ i <br /> � � � � �. � ���]�� � i 3 <br /> +46"_GFI(��y� ( u J p ^ +46'' GFI �� � ��,J� � � <br /> iyr <br /> � _ ► , oW � Patio `�� � � <br /> ° P .`.� I \ DISP � � I � � I , ,� <br /> � <br /> � � � � � � <br /> _. � �. � � i i <br /> � — i � I I � ' � ,� 1 � � � � .,� � ; <br /> _—/�� 46"I GFI I / � � � � � � � � ,� L '1 �� ; <br /> �j, � �. <br /> � ` � � O �. I � '� � � <br /> � �TR� ----_._.---.- � � I .� �. \ � tm <br /> F F-- � '�._ ,. � � %i' � I , <br /> � �.\ �" _ _ - , � � ._ � � _ � � I � �'S �e�tr��a9 Wt�y'; S�e �I(,� .. <br /> ~� � � I ll� � - - - _ � K�,�kln��;f�1c�sh�r�g�t�� ����3� ' <br /> '.� 1', �.� i � iI I � i�� ��� r i��.� ��42�,454 �1t�0 F ���6'S�,�l���� �' <br /> _ _ _ _ � . <br /> , � , �. +46�'�F� Kitchen ; � �.� �. , � � <br /> ! � --- !-----------�� ! � �e� 4v�,�v rl����rdtu�c�t cnm <br /> M. Bath �•� � l � � --- -- -�-�----�'-Zi � �� I � +72" <br /> ,,. �.,,. _:_ . . ,_:. � ..:�. ,,, ,�: <br /> , - - - 1 , ,.� Master Bedroom ; � � � '�' , � i <br /> , <br /> _ I i +4s�� i � �� _ _ � �" � i i � i �'`'� <br /> +44" cF� �+4a" cFf j � � � / � \ I` i �" I ,� i 5052 REGISTERED <br /> Creafi Room — <br /> i i �� <br /> _ � ;� � T� � � 4 � \ i � � j \�J � � ARCHIT�GT <br /> � ��q� � � 1 \ � � �\ <br /> � � ' \ � � +46" GFl • I \. t <br /> I � � YY . . � � ---------------------- \�. �._` '—.-.. I \ � ROBERT E. WEIBLE <br /> � j ► OUTLET AT ATTIC� � T <br /> \ � �.� �� STATE OF WASNINGTON <br /> j � � LIGHT AT ATT1C �( _ _ \� � ���{ � � � � � <br /> � � �. � � � ~ � � � j SMURF TUBE � <br /> Bedroom 2 j I � � ' TEL • � �. W/BLANK PLATES � <br /> i � �� Sp /i � - \� I DO(1BLE-GANG WITH � � ..� <br /> � L _ � � Di�in� I I / � � � � COAX �& BLANK PLATE , � <br /> �•� — _ I I i I TV — °' <br /> � N <br /> ( � <br /> � /,�._.\ � � / I <br /> \ - � � � � I I - - - -- __ '�:.. <br /> � _ 3 3 � I I � O I I I � � <br /> � PLATFORM ACE �� � �' I I -�--,� AT CRAWL � <br /> � � ` � � I I �SD I �I SPACE � <br /> SD ABOVE �.� � ` - - - - � � EQ. E4. \ I I ( �I <br /> � - ----------=�- � ,� � � � i� v; <br /> TV I � O i.� I � �.— � o `� <br /> �I C �� \ i �� v <br /> �" ( �\�� ���� I `"� � i a'� � <br /> Laund �1 � � � ;%�� `� ' ` � � � <br /> ry ' `TIMER � I �- �._ � � I _ _ � � - - - <br /> .-' � <br /> �-� � TO LI WT � <br /> � ��-�- .-�Q_WNF � i �.� .\\ �I ,.� / A 0 � � <br /> . ., <br /> _. <br /> `i'`�. .,. ----.._� <br /> _. � <br /> , <br /> _._. �� � � '�---- � . ....� . � � .� <br /> � _ - - `.� , ...�..... .... .. . .. RETURN R �� � <br /> � �tn SD E-- - - - F....•.. ��....•- � <br /> ` � � ���� � GRILLE ABOVE I I � ..� <br /> WASHER •6RYER �v, � _ _ _ �..�.���:......_�:.�:...:r.�"....... �- � � • ,._ — <br /> 1 -- <br /> ---- -�Tf�----------- <br /> _ R RN - l � <br /> --- 1 AI l �.., �.\ ........�.......�.... .�.....� LJ �. I I � � <br /> /� G L �.\ � : : .PW.d�: :.-��:�:�:•:�:�:�:�;�:�:�. \ I I �H�E � � <br /> ,. � � Den .� <br /> , _._ _. , � � � <br /> oc � � �_ � P� t / \ o �A <br /> i � Bonus i ' �� �/ � +48 Ent�y i � - - ' — `7 <br /> PRESSURE � <br /> o O <br /> VTR , Br�.�h � j� RELIEF VALVE � � l � � �„� z <br /> � J� � TO OUTSIDE �� 1\ � � i <br /> � �� PREWIRE LOW VOLTAGE j �� <br /> � � � � <br /> � � � _ _ _ _ WIRE FOR GARAGE DOOR , . <br /> � �-� � OC ` _ � OPENER & ELEC. EYES. �- \� -" -" � � <br /> � a o " VERIFY WITH MFR. _ �. � � o � <br /> -�- 9 - - � ` � � 1 � � � � <br /> �' j `,. , °' c0 <br /> _ � <br /> TV �----------- - ———� � � � <br /> � � i � �AT CElLING 3 `• � �/� <br /> / � SD SD \. r-----------------------------� I � � � � I 1// <br /> � \ � I � / \ � ' I � <br /> � � i � �.� � e �� � I <br /> \ i � / � /. i � <br /> � �i I / � <br /> I �\ � GAS I � \ \ � � o; �' <br /> I / I p <br /> � i i � � _ _ � METER i /�� \\ Porch i � � M <br /> � � � \ o <br /> I , - I �� i <br /> I � Q HOSE +as" I f \ \ � � <br /> , ° ' Gara�e �� , � � <br /> , � Bedroom 4 � BiBB � � %� ; � <br /> Bedroom 3 i i _ E�Ec__ ; ELEC � � � w� � � <br /> � � METER � PANEL� i � i � <br /> i I ■r� <br /> � i � l � �a � <br /> I � <br /> " � l <br /> I � _ � 3 = <br /> __ � <br /> TV � co -----------r----- -7 <br /> � � i �--�--- / � � <br /> `r I�-----------------------------� <br /> � � <br /> �. <br /> � � <br /> ' - -�— _ _ _._ _ _ _ _ _ _,_ _ _ _ ` — � _. � � <br /> +84" _._._._. +84" � <br /> � <br /> ABOVE SLAB ABOVE SLAB ;; �- <br /> � u <br /> �, _ <br /> ELEVATION OF ELECTRICAL OUTLETS A.F.F. � <br /> P <br /> AT KITCHEN REVISED. <br /> �� " SECOND FLOOR ELECTRICAL PLAN � " FIRST FLOOR ELECTRICAL PLAN <br /> 1/4"=1'-0" 1/4"=1'-0" <br /> .E-� <br /> � � <br /> � _ <br /> E L E C T R I C A L L E G E N D G E N E R A L N O T E S DUCT AND VENTILATION NOTES �, Q <br /> THIS ELECTRICAL PLAN IS THE ARCHITECT'S SUGGESTED VENTILATION: SEE NOTES ON COVER SHEET. 1 L � � <br /> � DUPLEX RECEPTACLE OUTLET DIRECTIONAL INCANDESCENT � HEAT LAMP, EXHAUST LAYOUT. THE ELECTRICAL CONTRACT IS ON A DESIGN-BUILD � o O <br /> CEI�ING MOUNTED LIGHT � FAN COMBINATION RECESSED BASIS. ELECTRICAL CONTRACTOR'S DESIGN SHALL BE KITCHEN EXHAUST FAN TO BE 100 CFM MIN. AND SHALL VENT U <br /> � � <br /> � DUPLEX RECEPTACLE OUTLET CEILING FIXTURE - 250W LAMP APPROVED BY THE OWNER AND SHALL CONFORM TO THE TO OUTSIDE. � � � <br /> SPLIT WIRED SWITCH TOP HALF INCANDESCENT RECESSED 50 CFM MIN 4.0 SONES, APPLICABLE ELEGTRIC CODE REGARDLESS OF WHAT IS SHOWN � <br /> � � » ' ON THIS DRAWING. ALL EXHAUST DUCTS SHALL BE RIGID METAL, AND SHALL BE � y � <br /> � CEILING LIGHT 4 ROUND DUCT FITTED WITH A TIGHT FITTING BACGGAFT DAMPER CAPABLE OF � Rf `�'y <br /> MW� DUPLEX RECEPTACLE OUTLET F RECESSED CEILING ALL SWITCHES, OUTLETS AND ENVIRONMENTAL CONTROLS CLOSING WHEN TNE FAN IS NOT IN USE. M � � � <br /> MICROWAVE � INCANDESCENT WALL � EXHAUST FAN SHALL BE MOUNTED NOT LESS THAN 15" NOR MORE THAN 48" (� �,; L <br /> MOUNTED LIGHT 50 CFM MIN, 1.5 SONES, ABOVE FINISHED FLOOR AND SHALL BE ALIGNED VERTICALLY. DUCTS IN UNHEATED SPACES INCLUDING ATTICS SHALL BE <br /> INSULATED TO A MINIMUM OF R-4. ,� � � � <br /> � SINGLE RECEPTACLE OUTLET 4" ROUND DUCT � �. Z <br /> 208v (R: RANGE, D: DRYER) I � DOUBLE TUB� FLUORESCENT APPLIANCES DESIGNED TO BE FIXED IN POSITION SHALL BE G� � <br /> J CEILfNG MOUNTED LIGHT ��J HOOD COMBI�ATI�NRANGE SECURELY FASTENED IN PLACE. TOP FLOOR EXHAUST FANS SHALL VENT THROUGH ROQF. � � � 0 <br /> Q JUNCTION BOX Mw <br /> EXHAUST FAN TO PROVIDE WATER HEATERS SHALL BE ANCHORED OR STRAPPED AT MECHANICAL VENTII_ATING SYSTEMS IN BATHROOMS AND � � � <br /> � SINGLE POLE SWITCH -�- RECESSED HEAT LAMP - A MIN. OF 100 CFM. POINTS WITHIN THE UFPER 1/3 OR LOWER 1/3 TO RESIST LAUNDRY ROOMS SHALL EXHAUST DIRECTLY TO TH� OUTSIDE. � <br /> "I" NUTONE 9410H, 250W LAMP � � '-' , METER CENTER EARTHQUAKE MOTION. DUCTS PENETRATING OCCUPANCY S�PARATION BETWEEN '� �- <br /> 3 THREE WAY SWITCH CEILING FIXTURE �/� <br /> � LIGHT FIXTURES THAT SERVE TO IL�UMINATE INTERIOR STAIRS GARAGE AND DWELLING, AND WITHIN THE GARAGE SHALL BE y� <br /> INCANDESCENT CEILING � ELECTRICAL PANEL SHALL BE LOCATED IN THE IMMEDIATE VICINITY OF EACH STAIR CONSTRUCTED OF N0. 26 GAUGE SHEET STEEL. <br /> oiM.� DIMMER SWITCH � MOUNTED LIGf-IT LANDING AND SHALL PROVIDE A MIN. LIGHTING LEVEL OF 1 � <br /> � <br /> �T THERMOSTAT FOOT-CANDLE MEASURED AT CENTER OF TREADS AND DRYER EXHAUST DUCT SHALL BE 4" RIGID M�TAL WITH A 4" � <br /> �T TIMER SWITCH LANDINGS PER IRC R303.7. OPENING ON THE EXHAUST HOOD. THE DRYERS SHALL BE � <br /> 24 HR CLOCK TIMER - O CARBON MONOXIDE � SMOKE DETECTOR GENERAL ELECTRIC. DRYER SHALL BE INSTALLED ACCORDING ;� <br /> � AUTOMATIC DETECTOR � E N E R G Y N O T E S TO MANUFACTURER'S INSTALLATION INSTRUCTIONS ON SITE. � <br /> FLOOR REGISTER '�� <br /> SEE ENERGY NOTES ON SHEET D1. � <br /> � � SMALL FLUORESCENT � REGESSED CEILING WHOLE HOUSE o Job No.: 14-38 <br /> STRIP LIGHT EXHAUST FAN MEETING CFM TEL� TELEPHONE JACK FURNACE AND WATER HEATER SHALL BE FUELED BY � — <br /> WHF REQUIREMENTS OUTLINED IN IRC TV TELEVISION JACK NATURAL GAS. THE PILOTS, BURNERS, HEATING ELEMENTS �� Sheet No.: <br /> �� PENDANT LIGHT SECTfON M1057.3. � <br /> t'P AND SWITCHES SHOULD BE A MINIMUM OF 18" ABOVE THE � <br /> GARAGE FLOOR. � <br /> � <br /> T <br />