Turnarounds Required- Roads with a length of 501-750 feet must be 26 feet wide; 96' <br /> diameter cul-de-sac, 120' Hammerhead or Y and 120' Tee is required. <br /> Abe erlrad uslmusf bgproide'd Existingrcurbsin`the area must be adjusted to meet turn <br /> ra®iu**.f cattoo <br /> 2. One Knox Box is required for each building, to be placed by the alarm/sprinkler room. <br /> 3. Fire lanes shall be provided as required in Everett Municipal Code 46.44. Fire lanes shall be <br /> identified by red curbs with White stenciling stating"NO PARKING FIRE LANE" and vertical <br /> signs stating "NO PARKING FIRE LANE -TOW AWAY ZONE - EMC 46.28.130". Location <br /> shall be approved by the Fire Code Official. <br /> 4. Easement Marking - Fire apparatus access roads on easements shall be marked whenever <br /> necessary to maintain the unobstructed minimum required width of roadways. The <br /> easement shall be marked as follows: <br /> a. Curbs shall be identified by red traffic paint with a 6-inch wide stripe on the top and front, <br /> extending the length of the designated fire lane. <br /> b. 'Rolled curbs shall be identified by red traffic paint with a 6-inch wide stripe on the curb, <br /> extending the length of the designated fire lane. <br /> c. Lanes without curbs shall be identified by red traffic paint with a 6-inch wide stripe on the <br /> pavement, extending the length of the designated fire lane. <br /> d. The words 'NO PARKING - FIRE LANE' shall be in 3-inch stroke white letters 18 inches <br /> in height, and placed 8 inches measured perpendicular from the red paint stripe on the <br /> pavement. In most cases, both sides of the access road shall be marked. Where long drives <br /> are to be marked, the repetitions shall alternate sides of the drive. <br /> e. Marking shall also include the addition of metal signs stating 'NO PARKING - FIRE <br /> LANE-TOW AWAY ZONE - EMC 46.28.130'to be installed at intervals or locations <br /> designated by the Fire Code Official. The signs shall be approximately 12 inches in width <br /> and 18 inches in height and have red letters on a white background. Metal signs shall be <br /> installed on either 2-inch metal pipes for private property or treated 4-inch by 4-inch wood <br /> posts for public property and shall be located so that the bottom of the sign is a minimum of <br /> 7 feet above the curb. Where fire lanes are adjacent to buildings or structures and when <br /> approved or directed by the Fire Code Official, the signs may be placed on the face of the <br /> building or structure. <br /> f. Where directed by the Fire Code Official, specific areas shall be designated and those <br /> areas are to be marked with diagonal striping across the width of the fire lane. Diagonal <br /> marking shall be used in conjunction with painted curbs and/or edge striping and shall run at <br /> an angle of 30 to 60 degrees from one side to the other. These diagonal lines shall be in red <br /> traffic paint, parallel with each other, at least 6 inches in width and 24 inches apart. Lettering <br /> shall appear as above. <br /> 9,1)U <br />