My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
5700 23RD DR W 2018-06-28
>
Address Records
>
23RD DR W
>
5700
>
5700 23RD DR W 2018-06-28
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/28/2018 8:47:07 AM
Creation date
6/28/2018 8:46:35 AM
Metadata
Fields
Template:
Address Document
Street Name
23RD DR W
Street Number
5700
Notes
GEOTECHNICAL REPORT INCLUDED
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
201
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
10. Fire flow for Buildings E, F, and G is 1,500 gpm. <br /> 11. Portable Fire Protection -A portable fire extinguisher with a minimum U.L. rating of 2-A:10- <br /> B:C shall be provided within 75 feet of travel on all floors of each building during <br /> construction and prior to occupancy. <br /> 12. Fire Alarm System -An approved automatic fire detection system shall be provided as <br /> required by City Ordinance No. 3021-07, Chapter 16/6, of the Everett Municipal Code. <br /> Plans for such system shall be submitted to the Fire Code Official for review and approval <br /> prior to installation. Submittal shall include cut sheets of all equipment intended for use. <br /> Appropriate trip tests, witnessed by a Fire Department Inspector, shall be performed, along <br /> with a certificate of completion, prior to final acceptance of the system. <br /> Fire alarm systems shall be installed according to NFPA Chapter 72. Installation of fire <br /> alarm components, including basic wiring, may not commence before plans are <br /> approved by the Fire Department Plan Reviewer. Fire alarm drawings must be <br /> professionally rendered, in sufficient detail, and must be internally consistent. Riser <br /> diagrams must match installation plans and load calculations. Components must be listed <br /> and-approved for use together. Changes to plans must include new drawings and <br /> calculations and must be approved by the Fire Department Plan Reviewer prior to <br /> installation. Fire alarm installation is subject to field inspection by a Fire Department <br /> Inspector. An approved set of plans and the Engineering & Public Services Department <br /> electrical permit must be present for any installation inspection: <br /> Fire alarm systems shall be installed under permit of the City of Everett Engineering & Public <br /> Services Department. Electrical inspections and approval are required prior to calling for <br /> acceptance tests. Call (425) 257-8810 for permit information. ' " <br /> The absence of working phone lines for the alarm system will be cause for <br /> postponing Fire Department inspection and testing and shall result in denial of <br /> occupancy. <br /> A copy of NFPA 72 Record of Completion form must be filled out prior to final occupancy <br /> (NFPA 72, 2007 Edition, page 72-33). <br /> Call for design requirements per Authority Having Jurisdiction: <br /> Automatic smoke detection is required. <br /> 13. For buildings with two or more floors, including sub-floors, the alarm system must call <br /> point-by-point reporting to an-alarm center. <br /> 14. Fire Suppression (Sprinkler) System -An approved automatic suppression system shall be <br /> provided as required by City Ordinance No. 3021-07, Chapter 16.76, of the Everett <br /> Municipal Code. The system must include a mechanical water gong bell. <br /> Plans for any such system shall be submitted to the Engineering & Public Services <br /> Department for examination and approval. Such plans shall include plans for the <br /> underground mains that will supply the sprinkler system. <br /> ��l/J <br />