My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
5700 23RD DR W 2018-06-28
>
Address Records
>
23RD DR W
>
5700
>
5700 23RD DR W 2018-06-28
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/28/2018 8:47:07 AM
Creation date
6/28/2018 8:46:35 AM
Metadata
Fields
Template:
Address Document
Street Name
23RD DR W
Street Number
5700
Notes
GEOTECHNICAL REPORT INCLUDED
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
201
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Envelope Summary ENV-SUM, <br /> 2015 WSEC Compliance Forms for Commercial Buildings including R2,R3,&R4 over 3 stories and all R1 Revised Jun 2016 <br /> Project Info Project Title: Northshore Academy-Pavilion 2 Date 07/01/2016 <br /> Como <br /> forms Applicant Information. Provide contact information for individual who can For Building Department Use <br /> C <br /> Co npl anterequia respond to inquiries about compliance form information provided. <br /> dpassword to use. Company Name: 2812 architecture <br /> Instructional and <br /> calculatingngcells areColby Company Address: 2812 Avenue,everett WA 98201 <br /> write-protected. Applicant Name: Adam Clark <br /> Applicant Phone: (425)252-2153 <br /> Applicant Email: adam@2812architecture.com <br /> Project Description ❑ New Building 0 Addition ❑Alteration <br /> Occupancy Type QQ All Commercial 0 Group R-All R1 and R2, R3,R4 over 3 stories 0 <br /> Selection required to enable forms. <br /> Envelope Compliance Path 0 Prescriptive QQ Component Performance <br /> Selection required to enable forms. <br /> Component Performance 0 Standard Q Change of Occupancy/Conditioning 0 <br /> Calculation Type <br /> Selection required to enable ENV-UA ❑Additional Efficiency Package Option-C406.8 Enhanced Envelope <br /> and ENV-SHGC forms. To comply,demonstrate building thermal envelope performance is 15%lower than the Target UA. <br /> ❑ Air barrier testing per Section C402.5.1.2 ❑Air barrier testing not required <br /> included in project scope <br /> Air Barrier Testing Q Additional Efficiency Package Option-C406.9 Reduced Air Infiltration <br /> To comply,demonstrate that measured air leakage of building envelope does not exceed 0.25 <br /> cfm/ft2(air barrier surface area)under test pressure of 0.3 inch w.g. <br /> Vertical Fenestration and Total Vertical Gross Exterior <br /> Skylight Area Calculation Fenestration Above Grade %Vertical <br /> Prescriptive Path-Enter values for (rough opening) divided by Wall Area times 100 equals Fenestration <br /> vertical fenestration,skylights,gross walls 967 . 0 _ 5927 . 0 X 100 = 16. 3% <br /> and roof on this ENV-SUM worksheet. <br /> Component Performance-Enter values Gross Exterior <br /> in ENV-UA and/or ENV-UA-GROUP-R Total Skylight divided by Roof Area times 100 equals %Skylight <br /> worksheet. These values auto-fill from <br /> ENV-UA and are write-protected on ENV- 0 . 0 - 7423. 0 X 100 = 0. 0% <br /> Vertical <br /> • Fenestration VERTICAL FENESTRATION AREA COMPLIES <br /> Fenestration Area Compliance Area <br /> Skylight Area SKYLIGHT AREA COMPLIES <br /> Vertical Fenestration 0 High performance fenestration U-factors and SHGC per C402.4.1.3 <br /> Alternates 0 Dedicated outdoor air system per C402.4.1.4 and C403.6 <br /> Show locations of qualifying daylight zone Q In buildings>3 stories,25%or more of NET floor area is in daylight zones per <br /> areas and ft2 on project plans. <br /> 0 In buildings<3 stories,50%or more of CONDITIONED floor area is within daylight zones per <br /> For Daylight Zone Area Calculations- C402.4.1.1 <br /> a)Sidelight areas include primary+ Daylight Zone Calculations <br /> secondary daylght zone areas. Daylight Zone Fenestration Alternate Sidelight Daylight Toplight Daylight Percent Daylight <br /> b)Include overlapping toplight and Not Selected.No Calculations Required Zone Area Zone Area Zone Area <br /> sidelight daylight zone areas under <br /> Toplight. <br /> c)Refer to Chapter 2 for net floor area <br /> Spaces in Single Story List all enclosed spaces that exceed 2,500 ft2,have ceiling height greater than 15 ft,and are space <br /> Building Requiring Skylights types required to comply with this provision. <br /> Code requires a minimum of 50%of the floor Space Area(ft2) DLZ Area(ft2) SRR or Aperature Exception <br /> area to be within a skylight daylight zone for <br /> snecific snace tvnes.Refer to C402.4.2 for <br />
The URL can be used to link to this page
Your browser does not support the video tag.