My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
5700 23RD DR W 2018-06-28
>
Address Records
>
23RD DR W
>
5700
>
5700 23RD DR W 2018-06-28
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/28/2018 8:47:07 AM
Creation date
6/28/2018 8:46:35 AM
Metadata
Fields
Template:
Address Document
Street Name
23RD DR W
Street Number
5700
Notes
GEOTECHNICAL REPORT INCLUDED
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
201
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
c r <br /> PUBLIC WORKS <br /> February 3, 2017 <br /> Manal Shawish <br /> 2812 Architecture <br /> 2812 Colby Avenue <br /> Everett, WA 98201 <br /> Owner: Northshore Christian Church <br /> Job Address: 5700 23rd Drive W <br /> Plan Check No: B1612-008 <br /> RE: Corrections Letter <br /> Dear Ms. Shawish, <br /> In response to the application for a building permit, the plans have been examined and you are <br /> advised that revisions may be necessary before a permit can be issued. Please review and <br /> respond to the comments below. <br /> In order for the processing of your application to continue, it will be necessary to provide the <br /> Building Division with two new sets of revised construction documents reflecting the corrections <br /> requested. Please include a response letter which indicates how the corrections were resolved. <br /> General <br /> 1. An elevator (or interior ramp) should be provided for this project. Section 1104.5 <br /> 2. It should be verified that a grease interceptor will be provided for this project or that an <br /> existing interceptor on site is adequate for the increased discharge as required by <br /> Industrial Pre-Treatment. <br /> 3. The Type I hood and exhaust duct will be reviewed under separate permit however the <br /> wall behind the hood should be shown as steel-stud framed. IMC <br /> 4. Emergency egress lighting should be shown at the exterior of the building at the exit <br /> discharge locations. Section 1008.3.2 <br /> 5. The rise and run of the stairs should be shown on the plans. Section 1011.5.2 <br /> 6. Handrail extension requirements should be shown on the plans. Section 1014.6 <br /> 7. The storage under the stairs should be noted to be of minimum one-hour fire-resistive <br /> construction. A detail should be provided for the fire-resistive lid (as fire-tested in the <br /> horizontal configuration). Section 1011.7.3 <br />
The URL can be used to link to this page
Your browser does not support the video tag.