My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
615 80TH ST SW 2022-01-03
>
Address Records
>
80TH ST SW
>
615
>
615 80TH ST SW 2022-01-03
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/3/2022 3:30:11 PM
Creation date
6/28/2018 10:26:31 AM
Metadata
Fields
Template:
Address Document
Street Name
80TH ST SW
Street Number
615
Notes
GEOTECHNICAL REPORT INCLUDED
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
106
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Compliance Forms for Commercial Buildings including R2, R3, & R4 over 3 stories and all R1 Revised Jun2016 <br />Project Info <br />Project Title: POCOCK RACING SHELL ADDITION <br />Date 12/15/2016 <br />Compliance forms <br />do not require a <br />password to use. <br />Instrcalculating sand <br />calculating cells are <br />Applicant Information. Provide contact information for individual who can <br />respond to inquiries about compliance form information provided. <br />For Building Department Use <br />Company Name: SUPERSTRUCTURES BUILDING SYSTEMS <br />Company Address: 221 EVERETT AVE, SUITE #204, EVERETT WA 98021 <br />Applicant Name: JIM ARMSTRONG <br />write: protected. <br />Applicant Phone: 425-252-9000 (206-T86-0918 CELL) <br />Applicant Email: jimarmstrong@superstructuresinc.com <br />Project Description <br />❑ New Building P Addition ❑ Alteration <br />Occupancy Type <br />QQ All Commercial O Group R - All R1 and R2, R3, R4 over 3 stories O <br />Selection required to enable forms. <br />Envelope Compliance Path <br />O Prescriptive © Component Performance <br />Selection required to enable forms. <br />Component Performance <br />Standard Q Change of Occupancy/Conditioning 0 <br />Calculation Type <br />❑ Additional Efficiency Package Option - C406.8 Enhanced Envelope <br />To comply, demonstrate building thermal envelope performance is 15% lower than the Target VA. <br />Selection required to enable ENV-UA <br />and ENV-SHGC forms. <br />Air barrier testing per SectionC402.5.1.2 Air barrier testing not required <br />included in project scope <br />Air Barrier Testing <br />Q Additional Efficiency Package Option - C406.9 Reduced Air infiltration <br />To comply, demonstrate that measured air leakage of building envelope does not exceed 0.25 <br />cirnlW (air barrier surface area) undertest pressure of 0.3 inch w.g. <br />Vertical Fenestration and <br />Total Vertical Gross Exterior <br />Skylight Area Calculation <br />Prescriptive Path -Enter values for <br />Fenestration Above Grade % Vertical <br />(rough opening) divided by Wail Area times 100 equals Fenestration <br />0.0 6473.0 X 100 = 0.0 % <br />vertical fenestration, skylights, gross walls <br />and roof on this ENV -SUM worksheet. <br />Component Performance - Enter values <br />in ENV-UA and/or ENV-UA-GROUP-R <br />worksheet. These values auto -fill from <br />ENV-UA and are write -protected on ENV- <br />Gross Exterior <br />Total Skylight divided by Roof Area times 100 equals % Skylight <br />0.0 _ 11144.0 X 100 = 0 . 0 0 <br />Vertical <br />Fenestration VERTICAL FENESTRATION AREA COMPLIES <br />Fenestration Area Compliance <br />Area <br />Skylight Area SKYLIGHT AREA COMPLIES <br />Vertical Fenestration <br />C7 High performance fenestration U-factors and SHGC per C402.4.1.3 <br />Alternates <br />0 Dedicated outdoor air system per C402.4.1.4 and C403.6 <br />Show locations of qualifying daylight zone <br />areas and ft2 on project plans. <br />Q in buildings k 3 stories, 25% or more of NET floor area is in daylight zones per <br />Q In buildings < 3 stories, 50% or more of CONDITIONED floor area is within daylight zones per <br />For Daylight Zone Area Calculations - <br />a) Sidelight areas include primary + <br />C402.4.1.1 <br />Daylight Zone Calculations <br />Daylight Zone Fenestration Alternate <br />Not Selected. No Calculations Required <br />Sidelight Daylight <br />Zone Area <br />Toplight Daylight <br />Zone Area <br />Percent Daylight <br />Zone Area <br />secondary daylght zone areas. <br />b) include overlapping toplight and <br />sidelight daylight zone areas under <br />Toplight. <br />c) Refer to Chapter 2 for net floor area <br />Spaces in Single Story <br />List all enclosed spaces that exceed 2,500 ft2, have ceiling height greater than 15 fi, and are space <br />Building Requiring Skylights <br />hypes required to comply with this provision. <br />Space <br />Area (ft) <br />DLZ Area (ft2) <br />SRR or Aperature <br />Exception <br />Code requires a minimum of 50% of the floor <br />area to be within a skylight daylight zone for <br />specific space types. Refer to C402.4.2 for <br />requirements. <br />DLZ = Daylight zone, <br />SRR = Skylight to roof ratio <br />Indicate aperature with "AP" prefix ( AP 1.1%) <br />
The URL can be used to link to this page
Your browser does not support the video tag.