Laserfiche WebLink
. Permit#: B170Z-052 <br /> Site Address: 111Q POPLRR ST <br /> Owner: EVERETT SCHOOL DIST 2 <br />' Tenant: HAWTHORNE ELEMENTARY <br /> App. Date: 2/24/2017 <br /> = ABBREVIATIONS GENERAL NaTES Pr°p°S�d �s�: <br /> Descriptian: TRANSFER PORTABLE CLASSROOM TQ <br /> � ELEMENTARY SITE INCL <br /> 4 LAM LAMINATED <br /> s � & OI^ � AND LAV LAVATORY 1. ALL WORK ON THIS PROJECT SHALL BE IN CONFORMANCE WITH ALL LOCAL CODES AND Revizwed By: �/ '�, � !� � I� <br /> � ANGLE LB LAG BOLT ORDINANCES AND SHALL CONFORM TO ALL LOCALLY ADOPTEQ BUILDING CODES. oate: <br /> � � AT aff��e s�t 1ob Si e Set Fire/Plannin Set <br /> ; �. CENTER LINE LBS POUNDS 2, THE CONTRAGTOR SHALL VISIT THE SITE PRIOR TO WORK. VERIFY AND COORDINATE EXISTING E V E R E TT P U B L I C S C H O L <br /> LP LIGHT POLE <br /> � = EQUAL LT LIGHT SITE AND BUILDING CONDITIONS IN RELATIONSHIP TO NEW WORK. IF DISCREPANCIES ARE <br /> � � # NUMBER NOTED, THE CONTRACTOR SHALL CONTACT THE ARCHITECT PRIOR TO WORK FOR <br /> U P PENNY LTS LIGHT SWITCH CIARIFICATION. <br />. L PERPENDICULAR M MIRROR <br />� � PLATE OR PROPERTY LINE MAX MAXIMUM 3. IF CONFLICTS ARE FOUND BETWEEN THE DRAWINGS AND/OR THE SPECIFICATIONS, THE <br /> � ROUND OR DIAMETER MB MACHINE BOLT CONTRACTOR SHALL SEEK WRITTEN CLARIFICATION FROM THE ARCHITECT OR PROVIDE THE <br /> AB ANCHOR BOLT MDF MEDIUM DENSITY FIBERBOARD MORE EXPENSIVE. <br /> MDO MEDIUM DENSITY OVERLAY <br /> ACT ACOUSTICAL TILE MECH MECHANICAL 4. UNLESS OTHERWISE NOTED, EXISTING ITEMS TO REMAIN ARE SHOWN IN A LIGFiTER LINE 8879 REGISTERED <br /> AD ABOVE DATUM MED MEDIUM <br /> ADJ ADJUSTABLE OR ADJACENT MFR MANUFACTURER WEIGHT THAN NEW ITEMS. RCHI CT <br /> . AFF ABOVE FINISHED FLOOR MH MANHOLE 5. DO NOT SCALE DRAWINGS. THE CONTRACTOR SHALL USE DIMENSIONS SHOWN ON THE <br /> AL ALUMINUM MIN MINIMUM Scott Alan onnor <br /> ALT ALTERNATE MISC MISCELLANEOUS DRAWINGS AND ACTUAL FIELD MEASUREMENTS. PROMPTLY NOTIFY THE ARCHITECT IF STATE OF WASHINGTON <br /> APN ACOUSTICAL PANEL MO MASONRY OPENING DISCREPANCIES ARE FOUND. <br /> � ARCH ARCHITECT MOD MODIFY <br /> B.M. BENCH MARK MR MOISTURE RESISTANT 6. ITEMS NOTED AS 'TYPICAL' ON ANY DRAWING SHALL APPLY TO ALL DRAWINGS. <br />�, BD BOARD MTD MOUNTED 7. CONSULTANT DRAWINGS ARE DIAGRAMMATIC AND SUPPLEMENTARY TO THE ARCHITECTURAL P E R M I T S E T - 2 i 2 3 / 2 O 17 <br /> BFF BELOW FINISH FLOOR MTL MEfAL DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF EACH CONTRACTOR & SUB CONTRACTOR TO <br /> BLD'G BUILDING MW MICROWAVE BIQ AND INSTALL THEIR WORK IN ACCORDANCE WITH THE ARCHITECTURAL DRAWINGS. ANY <br /> BLK'G BLOCKING N NORTH DISCREPANCIES BETWEEN THE ARCHITECTURAL DRAWINGS AND THE CONSULTING ENGINEER(S) ���� �� ������� <br /> BM BEAM NFHB NON-FREEZE HOSE BIBB DRAWINGS SHALL BE BROUGHT TO THE ATfENTiON OF THE ARCHITECT BY WRITTEN ���,/I��I�� ��� ������� <br /> BOT BOTTOM NIC NOT IN CONTRACT NOTIFICATION FOR CLARIFICATION PRIOR TO THE COMMENCEMENT OF THE WORK AFFECTED. <br /> BTWN BEfWEEN NO NUMBER <br /> ' C CLOCK OR COFFEE NOM NOMINAL 8. THE CONTRACTOR SHALL PROTECT, REPAIR, MODIFY AND/OR REPLACE ALL UTILITIES, �/I C I N I TY MAP S H E ET I N D EX <br /> CABS CABINETS NTS NOT TO SCALE PAVEMENTS, PUBUC & PRIVATE PROPERTIES, INSTALLATIONS, STRUCTURES, BUILDINGS OR <br /> CB CATCH BASIN OR CHALKBOARD OC ON CENTER PORTIONS OF, ABOVE OR BELOW GROUND DURING THE COURSE OF CONSTRUCTION TO <br /> CC CENTER TO CENTER OD OUTSIDE DIAMETER COMPLETE WORK SHOWN IN THE CONSTRUCTION SET. NOT ALL PROTECTION, REPAIR, NOT TO SCALE <br /> � CFCI CONTRACTOR FURNISHED & INSTALLED OFCI OWNER FURNISHED MODIFICATION OR REPLACEMENT REQUIRED IS SHOWN ON THE DRAWINGS. THE CONTRACTOR COVER � <br />, � CFI CONTRACTOR FURNISHED ITEM CONTRACTOR INSTALLED SHALL PROVIDE SUFFICIENT BUDGET TO COVER ALL PROTECTION, REPAIR, MODIFICATION <br />�. CH COAT HOOK AND/OR REPLACEMENT OF EXISTING UTILITIES, PAVEMENTS, PUBLIC & PRIVATE PROPERTIES, A0.1 COVER SHEET <br /> CJ CONTROL JOINT OF01 OWNER FUI�NISHED, <br /> OWNER INSTALLED INSTALLATION, STRUCTURES, BUILDINGS OR PORTIONS OF, ABOVE OR BELOW GROUND WITHIN <br /> CL. CENTER LINE OH OVERHEAQ THE BID SUM. PUGET S 529 SITE WORK <br /> CLG CEILING OHL OVERHEAD LINE sauND N0h°Mis <br /> CLR CLEAR OPNG OPENING 9. THE REPAIR, MODIFICATION OR REPLACEMENT OF ANY EXISTING UTILITY, PAVEMENT, PUBLIC & N R/VER ARCHITECTURAL (SCR ARCHITECTS) � <br /> CMP CORRUGATED METAL PIPE PRIVATE PROPERTY, INSTALLATION, STRUCTURE, BUILDING OR PORTIONS OF, ABOVE OR BELOW �. A1 .1 OVERALL SITE PLAN <br /> CMU CONCRETE MASONRY UNIT P POWER GROUND, SHALL MATCH THE ORIGINAL CONDITION IN QUALITY, SUBSTANCE AND APPEARANCE. o � � <br /> . C.O. CLEAN OUT P&S POLE AND SHELF PORT �� A1 .2 PARTIAL SITE PLAN <br /> COL COLUMN PL PLASTIC 10. WHERE EXISTING WORK IS CHANGED, MODIFIED, OR NEW WORK ADJOINS, CONNECTS TO OR cAR�NER �, A2.1 ENTRY RAMP/STAIR - PLAN & ELEVATIONS — <br /> CONC CONCRETE P-LAM PLASTIC LAMINATE ABUTS EXISTWG, THE EXISTING WORK SHALL BE ALTERED AS NEGESSARY, JOINED & �� Q <br /> CONT CONTINUOUS POC POINT OF CONNECTION CONNECTED IN A SUBSTANTIAL, NEAT AND WORKMANSHIP MANNER. �P OJ�� CO�RSE PORTABLE <br /> � CPP CORRUGATED PLASTIC PIPE - PLYW PLYWOOD <br /> . CPT CARPET PP POWER POLE 11. IT IS THE RESPONSIBILITY OF EACH CONTRACTOR & SUB CONTRACTOR TO REVIEW ALL ��°� PORTABLE CLASSROOM (1990 DWGS FROM EVERGREEN MOBILE) � <br />. CR CLASSROOM PR PAIR DRAWINGS AND SPECIFICATIONS INCLUDING ADDENDA TO IDENTIFY ALL WORK REQUIRED. THE -a`� 1 OF 7 FLOOR AND CEILING PLANS <br />' CORR CORRIDOR OR CORRUGATED PSI POUNDS PER SQUARE INCH CONTRACTOR OR SUB CONTRACTOR SHALL REVIEW EACH DRAWING AND COORDINATE BEiWEEN �'v 2 OF 7 REVERSE FLOOR AND CEILING PLANS � <br /> CT CERAMIC TILE PSL PARALLEL STRAND LUMBER ALL PLANS AND SPECIFICATIONS. FURTHER, EACH SUB CONTRACTOR SHALL COORDINATE o �- <br /> CUST CUSTODIAN THEIR WORK WITH THE GENERAL CONTRACTOR TO PROVIDE PROPER SEQUENCE, PLACEMENT, r �ER� ' 3 OF 7 SECTION <br /> PT POINT icoMMUN�tYi <br /> CW COLD WATER PTD PAPER TOWEL DISPENSER TOLERANCES AND REQUIREMENTS OF OTHER SUB CONTRACTORS. SUB CONTRACTORS SHALL � I COLLEGE � w 4 OF 7 ELECTRICAL PLAN � � <br /> BE RESPONSIBLE FOR THE REMOVAL & REPLACEMENT OF THEIR WORK THAT MUST BE Q 10 H ST. COLLEGE > 5 OF 7 EXTERIOR ELEVATIONS O <br /> DBL DOUBLE QT QUARRY TILE P�zn w <br /> DEPT DEPARTMENT MODIFIED, REPLACED, REPAIRED OR OTHERWISE ALTERED TO ACHIEVE THE DESIGN INTENT OR z a � 6 OF 7 INTERIOR ELEVATIONS � <br /> R RADIUS OR RISER CODE REQUIREMENT DUE TO LACK OF COORDINATION WITH THE GENERAL CONTRACTOR. Q <br /> . DTL DEfAIL RB RUBBER BASE c� �12 H ST � 7 OF 7 FOUNDATION PLAN O <br /> DF DRINKING FOUNTAIN RD ROOF DRA�N 12. WORK INSTALLED IN CONFLICT WITH CONSTRUCTION DOCUMENTS WILL BE CONSIDERED IN � O <br /> DIA DIAMETER RECP ELECTRICAL RECEPTICAL � - PROJECT SITE � <br /> DIFF DIFFERENCE REF REFRIGERATOR NON-CONFORMANCE AND SHALL BE CORRECTED A7 NO EXPENSE TO OWNER OR ARCHITECT. � a' HAVYTHORNE ELEMENTARY PORTABLE FOUNDATION �ARIES BUILDING SYSTEMS� <br /> � DIM DIMENSION o � 1110 POPLAR ST F1 FOUNDATION PLAN/NOTES/DETAILS � <br /> DIV DIVISION REV REVISIONS 13. FOLLOW MANUFACTURER'S INSTRUCTIONS, EXCEPT WHERE MORE STRINGENT REQUIREMENTS a EVERETT, wA. s82o� � <br /> DN DOWN REQ'D REQUIRED ARE INDICATED OR REQUIRED BY CONSTRUCTION DOCUMENTS OR APPLICABLE CODES, m 5 � <br />- RM ROOM ORDINANCES AND REGULATIONS. RAMP SYSTEM (WELCOME RAMP SYSTEM) � <br />� DR DOOR RO ROUGH OPENWG <br /> DS DOWN SPOUT RTDBcWR RECESSED TOWEL DISPENSER 1 of 1 ACCESS RAMPS & STAIRS � <br /> DVII DISHWASHER AND WASTE RECEPTACLE 19T T STANDARD PLANS/DETAILS/NOTES � � � <br /> DWG DRAWING RWL RAINWATER LEADER <br /> E�, EAST �NG S SOUTH OR SINK � <br /> S&P SHELF AND POLE � � <br /> EFC PDXY FLOOR COVERING SCD SEAT COVER DISPENSER - O J � � <br /> EJ EXPANSION JOINT SC SOLID CORE � N <br /> ELEC ELECTRICAL SD SOAP DISPENSER O I--� <br /> SHLV SHELVING <br /> � EO ELECTRICAL OUTLET SHT SHEET = z � <br /> ELEV ELEVATION SHTHNG SHEATHING L E GAL D E S C R I PT I O N n/ <br />_ EQ EQUAL SIM SIMILAR E Av <br />� EQUIP EQUIPMENT ■ <br /> SND SANITARY NAPKIN DISPENSER PARCEL 29051700212800: � Q <br /> EWC EPDXY WALL COVERING SNR SANITARY NAPKIN RECEPTACLE � <br /> EXIST EXISTING SPECS SPECIFICATIONS � H �� E � �� SEC 17 TWP 29 RGE 05LOT 1 CITY OF EV SP NO 5-92 REC AF NO 9207160196 & � � � �'j <br /> EXP EXPANSION w 2 <br /> EXT EXTERIOR SS� ST�AINRESS STEEL OR I Y 529 a SURV REC VOL 38 PG 118 OF SURVS AF NO 9207165001 BEING A PTN OF SE1/4 ^ <br /> FC FILE CABINET <br /> SANITARY SEWER � �o s❑ IFIC AV z NW1/4 LESS R/W TO CIIY EVE PER REC AF9807200464 U � W -+--+ <br /> FD FLOOR DRAIN STSWR STORM SEWER � Q � <br /> FDN FOUNDATION STD STANDARD � � <br /> � FE FIRE EXTINGUISHER STDPP STANDPIPE O L <br /> U FEC FIRE EXTINGUISHER CABINET � <br /> W SYMBOLS LEGEND PROJECT DATA <br /> � STL STEEL <br /> = FF FINISHED FLOOR STOR STORAGE %' <br /> • U <br /> a • FH FIRE HYDRANT STRUCT STRUCTURAL � �" w <br />_ �� FIN FINISH SUSP SUSPENDED <br />� o= FLR FLOOR SVF SHEET VINYL FLOORING BUILDING SECTION NUMBER �o, a;,o: CONCRETE STEEL NAME OF PROJECT: RELOCATE PORTABLE CLASSROOMS CODE DATA: � � -�-� <br /> �a FRP FIBERGLASS REINFORCED PLASTIC SWC SPECIAL WALL COATING a3.0 DRAWING SHEET NUMBER � (large � HAWTHORNE ELEMENTARY � <br /> FT FOOT OR FEET SITE JURISDICTION: CITY OF EVERETT � � <br /> a� TB TACK BOARD OR TOWEL BAR SCaIe� � <br /> FTG FOOTING TD TOWEL DISPENSER q.p SECTION NUMBER GLASS BUILDING CODE: 2015 INTERNATIONAL BUILDING CODE � L <br /> _° GALV GALVANIZED � � OWNER/AGENT: EVERETf SCHOOL DISTRICT #2 Q � <br /> �Z T&G TONGUE AND GROVE DRAWING SHEEf NUMBER ... ..�� CONCRETE � 3900 BROADWAY ZONING: R4 � � <br /> N� GB GRAB BAR TEMP TEMPERATURE � EVERETT, WASHINGTON 98201 = — <br /> �o GFB GYPSUM FIBER BOARD TME TO MATCH EXISTING � �small ��\ � \ EARTH ATTENTION: JENNIFER COLLINS TAX PARCEL #: 29051700212800 W U � <br /> � �� TOIL TOILET DETAIL NUMBER scale� ; �� ���;; CAPITAL PROJECTS � O <br /> NQ GL GLASS TOM TOP OF MASONRY •� DRAWING SHEET NUMBER �Un- 425-385-4190 LOT A R E A: s.8 4 A C R E S �/ O � <br /> GM GWB GLASS MAT GYPSUM WALL BOARD disturbed <br /> � o� GV GATE VALVE T O P T O P O F P L A T E } <br /> `�� GWB GYPSUM WALL BOARD TOS TOP OF STEEL � INTERIOR ELEVATION � � �"� }�` GRAVEL ARCHITECT: SCR ARCHITECTS PORTABLE: w � O <br /> � �� TP TEST PIT �y 6 �. ���c � � �: — � EARTH 1916 PIKE PLACE, SUITE 12-3fi7 <br />. �= GYP GYPSUM TPH TOILET PAPER HOLDER \ A5.I � DRAWING SHEET NUMBER ; / SEATTLE WA 98101 AGENCY OF JURISDICTION: WA STATE LABOR & INDUSTRIES (PORTABLE ONLY) W Q` r <br /> a~ S I I I ' \f I��� ' S 4 1990 SER. N0. 390-149 B � <br /> HB HOSE BIBB TFMR TRANSFORMER �/ -- WOOD ATT'ENTION: SCOTT CONNOR ORIGINALLY PERMITTED / / , � � � r <br /> �� HC HANDICAPPED TW TACK WALL SCOTT�SCR-ARCH.COM <br /> �= TYP TYPICAL - (milled� � <br /> � HD HAND DRIER 23 DOOR NUMBER PLYWOOD 206-458-7517 CONSTRUCTION TYPE: V-B (IBC - ORIGINALLY V-N UNDER UBC) <br /> �� HDBD HARDBOARD UPC UNIFORM PLUMBING CODE � HARDWARE GROUP NUMBER � , <br /> Zo HDWD HARDWOOD UG UNDERGROUND � WOOD PROJECT DESCRIPTION: RELOCATE PORTABLE CLASSROOM TO OCCUPANCY GROUP. E <br /> Qa HM HOLLOW MEfAL UL UNDERWRITERS LABORATORY (framing) ` ASPHALT EXISTING ELEMENTARY SCHOOL. <br /> . �W HO HOLD OPEN UNFIN UNFINISHED � ROOM SIGNAGE LOCATION �Y EXISTING ELEMENTARY SCHOOL BUILDING ON SITE: COVER SHEET <br /> Z� HR HOUR UON UNLESS OTHERWISE NOTED , ` (large <br /> �° HT HEIGHT /`� INSUl�TION ESTIMATED PROJECT VALUE: $ 16,400 BUILDING 1 MAIN 1952 & 1964 48,256 SQ. Ff. f SCALE AS NOTED <br /> � `�� HW HOT WATER UP UTILITY POLE I WINDOW TYPE ��`�"�� �� ri id scale� # � � <br /> =a UV UNIT VENTILATOR O C 9 � ACTIVITIES ON SITE: NORMAL ELEMENTARY SCHOOL EDUCATION & ACTIVITIES BUILDING #2 (ANNEX) 1992 24,139 SQ. FT. t <br /> � �o HWG HIGH WALL GRILLE COVERED PLAY 1987 3 960 SQ. FT. f <br /> HWH HOT WATER HEATER VNR VENEER ,,_ ,,,_ ,_,; � ASPHALT HOURS OF OPERATION: APPROX. 7:00 AM - 10:00 PM ' <br /> � � HWR HOT WATER RETURN VCT VINYL COMPOSITION TILE INSULATION -= small <br />� Z� HWS HOT WATER SUPPLY VEST VESTIBULE q LOUVER TYPE (batt) � SITE ADDREss: HA4VTHORNE ELEMENTARY SPRINKLERS: NO <br /> - � scale� 1110 POPLAR ST. <br /> �� HWT HOT WATER TANK VG VERTICAL GRAIN <br /> IBC INTERNATIONAL BUILDING CODE VWF VINYL WALL FABRIC EVERETi', WASHINGTON 98201-1439 AREA OF WORK: <br /> Z <br /> �� <br /> o� <br /> 0o IFC INTERNATIONAL FIRE CODE W WEST 1,191 SF +/- (INCLUDES 1 PORTABLE + RAMP SYSTEM AND ASPHALT) <br /> Q� ID INSIDE DIAMETER W/ WITH PROJECT SCOPE: <br /> �z IE INVERT ELEVATION W/0 WITHOUT <br /> , �o INSUL INSULATION WB WHITE BOARD PERMIT SET: 2/23/17 <br /> WORK UNDER THIS CONTRACT INCLUDES THE ADDITION OF ONE CLASSROOM <br /> INT INTERIOR WD WOOD � /a,ppROV�C� <br /> �� PORTABLE BUILDING ON SITE, INCLUDING SITE WORK AND ELECTRICAL p�gLIC �����E�'A��M�N� <br /> INV INVERT WIN WINDOW PROVISIONS. ELECTRICAL PROVISIONS INCLUDE POWER, FIRE ALARM, DATA �J <br /> ¢m WGL WIRE GLASS .� ��~'" <br /> Zo JST JOIST AND COMMUNICATIONS CABLING. � �""!' BY_ ,, ��'� �-� <br /> , <br /> w JT JOINT WM WATER MAIN �,y � _� � <br /> �Z WP WEATHERPROOF <br /> " KIT KITCHEN WR WASTE RECEPTACLE � '� �►�aF�vER�rr'����EW���0�P��M�T <br />` �� KPL KICK PLATE WT WEIGHT PLANNED OCCUPANCY: � ' �� ���,��,��1�. f�r)�F <br /> s <br /> �a WWM WOVEN WIRE MESH SEPTEMBER, 2017 <br />