<br /> GENERAL DEMOLITION NOTES �
<br /> 1. THE DEMOLITION PLANS INCLUDE THE SCOPE OF DEMOLITION WORK �
<br /> REQUIRED PRIOR TO STARTING THE MODERNIZATION WORK, BUT ARE �
<br /> NOT INTENDED TO INCLUDE ALL OF THE DETAIL REQUIREMENTS. ALL
<br /> DEMOLITION WORK NOT SHOWN ON DRAWINGS OR SPECIFIED WHICH IS �
<br /> REQUIRED FOR COMPLETION OF WORK INC�UDED IN THE CONTRACT
<br /> DOCUMENTS SHALL BE THE RESPONStBILITY OF THE GENERAL -��s
<br /> CONTRACTOR. ry
<br /> 2. COORDINATE ALL DEMOLITION WORK WITH ALL TRADES AND REVIEW �"�
<br /> DRAWINGS FOR EXACT LOCAl10NS OF ALL OPENINGS, ETC., PRIOR TO �--
<br /> STARTING WORK. �
<br /> 3. ALL EXISTING WAI.LS, STRUCTURE, DOORS AND OTHER ITEMS TO �
<br /> . REMAIN ARE SHOWN AS SOLID LINES OR INDICATED AS SUCH BY �
<br /> NOTE. ALL STRUCTURAL MEMBERS, SLABS AND ROOF �,.
<br /> STRUCTURE/DECKS ARE TO REMAIN UNLESS SPECIFICALLY NOTED �
<br /> OTHERWISE. ALL STRUCTURE, WAL�S, DOORS, WINDOWS, CABINETRY,
<br /> EQUIPMENT, �IXTURES, ETC., TO BE REMOVED ARE SHOWN DASHED OR �
<br /> NOTED AS SUCH. REMOVE ALL ACCESSORIES, EQUIPMENT, FIXTURES, r'1
<br /> FINISHES OTHER THAN PAINT, ETC. ... WHETHER SPECIFICALLY SHOWN �-�
<br /> OR NOT, UNLESS NOTED OTHERWISE. �
<br /> 4. SEE MECHANICAL AND ELECTRICAL DRAWINGS FOR DESCRIPTION OF
<br /> WORK UNDER THOSE SUBCONTRACTORS, INCLUDING UTILITIES AND
<br /> FIXTURES (I.E., SINKS, TOILET FIXTURES, EXTERIOR LIGHT FIXTURES)
<br /> SHOWN TO BE REMOVED ON TH1S PLAN.
<br /> �� �2 �� �� 5. EXTERIOR WALLS TO BE REMOVED ARE GENERALLY MASONRY OR
<br /> � � CONCRETE.
<br /> � L�_� _ '
<br /> � - — - - - .=w-.W._._ 6. ALL STRUCTURAL MEMBERS INCLUDING BEARING WALLS AFFECTED BY
<br /> THIS DEMOLITION ARE TO BE VERIFIED AND ADEQUATELY SHORED
<br /> � � 3 � � BEFORE REMOVAL.
<br /> �A� ! ' 7. REMAIN ALL EXISTING FINISH FLOORING IS TO BE REMOVED TO EXISTING
<br /> / SUBFLOOR, UNLESS NOTED OTHERWISE. A�L EXISTING FINISH
<br /> FLOORING IS ASSUMED TO BE VCT, CARPET OR SHEET VINYL UNLESS
<br /> � �= �(� 13 (E NOTED OTHERWISE. INFILL, PATCH AND REPAIR AS NECESSARY TO
<br /> � \ OFF PREP FOR NEW FLOORING INCLUDING AT REMOVED WALLS.
<br /> C�? (E) CMU 12 5 � 1
<br /> 3�
<br /> WA�L, FV O �E) � 8. REMAIN ALL EXISTING CEILINGS INCL.UDING ACOUSTICAL TILE, GRIDS,
<br /> EXISTING FEMALE � BOYS 2 � / GYPSUM BOARD, FURRING, INSULATION, �IGHT FIXTURES, MECHANICAL
<br /> RESTROOM 331 � DRESSING � GRILLES, AND OTHER CEILING-MOUNTED ACCESSORIES AND EQUIPMENT
<br /> Gg ___ � � 327 UP TO UNDERSIDE OF STRUCTURE, UNI.ESS NOTED OTHERWISE.
<br /> � 8 � I ��g� GISIEREQ
<br /> � 9. DOORS SHOWN TO BE REMOVED INCLUDE DOORS, FRAMES, SIDELITES, HITECT
<br /> ' TRANSOMS, CENTER POSTS, PIPE RAILS, HARDWARE, STOPS AND
<br /> I ADJACENT FURRING TO FUL�Y REVEAL ROUGH OPENING.
<br /> 5 12 C� (E) CMU ,
<br /> WAL�. FV 10. ALL MASONRY REMOVAL IS TO BE REMOVED BY SAWCUTTING. PATGH KE P. AGAN
<br /> � _ _ _ � AND REPAIR EXPOSED WALLS DAMAGED BY REMOVAL OF WORK AND STATE OF MIASHINGTON
<br /> ' LEAVE IN NEAT, CLEAN, FINISHED CONDITION. PROVIDE NEW LINTEL
<br /> TO SUPPORT CMU. SEE STRUCTURAL DRAWINGS FOR DETAILS.
<br /> E ,
<br /> EXISTING M LE SHOWER g 11. NEW WA�L OPENINGS IN EXISTING WALLS NOT DIMENSIONED ON THIS
<br /> RESTR00� 328 � PL.AN ARE SHOWN ON THE FLOOR PLANS. NEW OPENINGS IN
<br /> 330 EXISTING CONCRETE WALLS ARE TO BE SAWCUT.
<br /> G�--- - --- � - -- ---- ----- - - --- ----- - -- --- - -- 12. PATCH AND REPAIR ALL DAMAGED AREAS AFFECTED BY THIS WORK.
<br /> ' � 13. MISC NEW WORK TRIGGERED BY DEMOLITION IS SHOWN HERE ON
<br /> ' ' ' DEMOLITION PLANS.
<br /> �
<br /> � � � 14. ALL VOIDS IN GRADE OR BELOW SLABS RESULTING FROM THIS WORK
<br /> I ARE TO BE FII.LED WITH COMPACTED STRUCTURAL FILL OR
<br /> ' CONTROLLED DENSITY FILL TO REQUIRED NEW ELEVATION PRIOR TO
<br /> ' ' ' CONTINUING CONSTRUCTION.
<br /> �
<br /> G1 �Zl �3 G4 15. SEE SPECIFICATIONS FOR HAZARDOUS MATERIAL REMOVAL
<br /> ,✓ REQUIREMENTS. �
<br /> 16. AT INTERIOR CMU WALLS REMOVAL, VERIFY THE EXISTENCE OF �
<br /> FOUNDATION WALLS AND FOOTINGS. IF NOT SPECIFICALLY NOTED TO �
<br /> BE REMOVED ON THESE DRAWINGS OR STRUCTURAL DRAWINGS, THESE
<br /> FOUNDATION WALLS MAY BE ABANDONED IN PLACE. REMOVE TOP �
<br /> 3" OF FOUNDATION WALL AND FILL WITH CONCRETE FLUSH TO
<br /> ADJACENT SURFACE. �
<br /> �
<br /> N ,� DEM LITION PL,AN - BLDG 400 AREA �,
<br /> SC0�8: 1/8 = 1 —0 EXFP�-1 �
<br /> �
<br /> ��
<br /> �
<br /> �
<br /> �i�
<br /> CODED DEMOLITION NOTES �
<br /> Q OPENING IN (E) WA�L - SEE FLOOR PLAN FOR OPENINGS LOGATIONS & �
<br /> STRUCTURAL DWGS WHERE STRUCTURAL REINFORCEMENT IS REQUIRED. �
<br /> C� � �3 4 � 2U REMOVE DOORS, RELITES, FRAMES AND ALL ASSOCIATED HARDWARE TO
<br /> LEAVE CLEAN OPENING FOR INFILL. �
<br /> Q REMOVE SINKS. SEE MECH DWG FOR tNFO. �
<br /> I I I I � �4 REMOVE (E) RELITE, WINDOW & FRAME IN (E) WALL. CUT ROUGH �
<br /> � � , , �
<br /> OPENING FOR DOOR. SEE DOOR SCHED INFO.
<br /> I5� REMOVE WALLS. �
<br /> 6Q REMOVE & SALVAGE (E) CASEWORK, COUNTERTOP & SHELVES TO .i.
<br /> � � � �
<br /> UNOCCUPIED AREA, UNO. SEE DWG A3.1 �
<br /> � - - - �_/ �7 SALVAGE & RE�OCATE (E) SINK. SEE DWG A3.1 V�,I
<br /> � , , �
<br /> 80 REMOVE TOILET, SHOWER PARTITIONS & FiXTURES. SEE PLUMBiNG DWG J I.LI
<br /> 4 4 4 o FOR MORE INFO.
<br /> 12 O (E) 8" 12 � (E) 8" Gl.AY 12 � (E) 8" CLAY Q REMOVE BASE CONC CURB AS INDICATED. 0 � o
<br /> C�AY BLOCKS BLOCKS, FV BLOCKS, FV = � �
<br /> 10 SALVAGE & RELOCATE (E) DOOR. `U � �
<br /> � � _. _ T ' ' 11 NOT USED U t=
<br /> G
<br /> ( EXISTING �� �0 SALVAGE BOOK CASES, DOUBLE SIDE� 5' HIGH 12 SALVAGE (E) CMU OR (E) CI.AY BLOCKS. � j
<br /> LIBRARIAN � TEXT BOOK/NOVEL STORAGE. � 13 SALVAGE (E) MODULAR LOCKERS � � j
<br /> -� � 53 (150) 3'X6' BOOK CASES '
<br /> 6 � (3) DOUBLE SIDED 5' HIGH TEXT BOaIK/NOVEL � �� �
<br /> � � � STORAGE. SEE SHEET A3.2 FOR PORTABLE �; `-"
<br /> { 10 LIBRARY SPACE LAYOUT � � � z
<br /> I � � C� Q C�n � �„_ W `r
<br /> RESOURCE W � N
<br /> �� � _ J� � _ i � CE55ER
<br /> � � _ _ _ O � � � � O O O . O . ° 8��0� v�-�—
<br /> -- --- - --- - —�EXisTING - --�- - ---- --- --- ---------- - - - - � ------- --- - --- - --- - -------� \\��\\�\\ �\ \�\\\ \ � ' CX� O�C� O�
<br /> � WORK & STOR � I EXISTWG COL X�
<br /> I 52 I 2 � �
<br /> , EE - � 6 300 �
<br /> , � 4 � , b �
<br /> � � �
<br /> �-`� _ - - ' �
<br /> � � �10 i REMOVE MOVABLE PARTITION ONLY. , BLDG � � �
<br /> NO WORK ON TRACKS. PATCH CLG, ��O � �
<br /> (��. - - �� i-- - BULKHEADS & WALL TO MATCH a
<br /> BLDG �OO ° o
<br /> 2 � _ � _ ADJACENT FIN AS NEEDED, � �
<br /> I I AUDIQS VI SUAL 3 1 � , I � � ^ ,
<br /> IL — �o � EXISTING � # ARCHITECTURE
<br /> 51 MEDIA PRODUCTION � � I
<br /> nacarchitecture.com
<br /> - � ._. 6 I � 54 . . .
<br /> SEATTLE WA 98121
<br /> � � 7 j � a 2025 FIRP 206.41.4522 ITE 300
<br /> I T OPENING � 5 G
<br /> I I � BULKHEADFIN O I o0
<br /> � � , ,
<br /> � — — — � (—� ( � I „ : ¢ NAC NO 121-16027
<br /> � � — J =_ __ =_ �-� , ' , aRawr� CLC
<br /> -- - - -— -- - - -- - --- - ---- - --- _ ^ - --- - ----- - ----- - - --� �
<br /> I - _-_ ' _- r I I W��,,.. _ ,...�,.��., .,., r�.��t
<br /> v � L_� CHECKED MG
<br /> � , , , ;� BLDG 20 0
<br /> �� DATE 06-07-2017
<br /> �
<br /> ����� � � ��`��
<br /> n o
<br /> ;� �-- ri ,� �--
<br /> �
<br /> N 2 DEMOLITION PL,RN - BLDG 200 AREA N KEY PLAN DEMOLITION PLANS
<br /> Scale: 1/8 = 1 -0 �xF���-, NTS