Laserfiche WebLink
. _ _ <br /> REVISIONS <br /> �., <br /> DOCJR SCHEDULE � „ � W�� <br /> a a R ZWo <br /> DOOR FRAME DETAILS <br /> N ��Z <br /> DOOR NO SIZE - W x H TYPE MATL FlN GLZ TYPE MATL FlN GLZ HEAD HINGE JAMB STRIKE JAMB SILL LABEL NOTES DOOR NO � <br /> BF � <br /> 232 36 x $0 (E) (E) (E) (E) F-1 HM PT - 3 4 3 5 - NOTE 2 232 <br /> 233 36 x 80 (E) (E) (E) (E) F-1 HM PT - 3 4 3 5 - NOTE 2 233 � <br /> 234 36 x 80 (E) (E) (E) (E) F-1 HM PT - 3 4 3 5 - NOTE 2 234 o w <br /> �n = <br /> 235A 36 x 80 (E) (E) (E) (E) F-1 HM PT - 3 4 3 5 - NOTE 2 235A W v�i � 2^ -fYP <br /> 240 36 x 80 A STG PT C F-1 KD PT - 6 7 7 4/A3.1 - NOTE 9 240 = ^ Q � <br /> 24QA 36 x 80 (E) (E) PT (E) F-1 HM PT - 6 7 7 5 - NOTE 2 240A � w � <br /> 241 36 x 80 A STC PT C F-1 KD PT - 6 7 7 4jA3.1 - NOTE 9 241 '� N � <br /> 241A 36 x 80 (E) (E) PT (E) F-1 HM PT - 6 7 7 5 - NOTE 2 241A _ _ _ � <br /> 242 36 x 80 A STC PT C F-1 KD PT - 6 7 7 4/A3.1 - NOTE 9 242 SEE DR � <br /> 242A 36 x 80 (E) (E) PT (E) F-1 HM PT - 6 7 7 5 - NOTE 2 242A A F'� SCHEp TY � <br /> 331 36 x 80 (E) (E) (E) (E) F-1 HM PT - 3 4 3 5 - NOTE 2 331 DUOR TYPES FRAME TYPES t"', <br /> � <br /> Scale: 1/4" = 1'-0" � <br /> DOOR GLAZING TYPES � <br /> TYPE A �" THiCK SINGLE SHEET TEMPERED SAFETY G�, CLEAR � <br /> TYPE B NOT USED. FACE OF WALL THICKNESS OF WALL INCLUDING <br /> TYPE C 1" INSULATED GL, BOTH SHEETS TEMPERED SHEATHING (INT. GWB AND/OR � <br /> TYPE D 1'� INSULATED GL �� � <br /> TYPE E �" THICK SINGLE SHEET GL, CLEAR 4 TO 4Yz EXT. GYP) `� <br /> (E) EXISTING '-�- � � <br /> � <br /> , �\ W ---�--� � w� � <br /> , .�../..::. ',' �� Y i� i i � !„_ <br /> � <br /> -' HINGE SIDE v � I �� I w z � <br /> '�� OF FRAME � I ���� I W � <br /> J / \� � <br /> i� � <br /> 3 -- --� � CJ � <br /> �� STUFF BATT -� J �` w <br /> 4:::<:T-:�:'::•�:.::�::,:=.;:�'� FRAMEINTO � 2,� <br /> R40M FINISH SCHEDULE �� <br /> TYP <br /> FLOORiNG BASE NQRTH WALL EAST WAI.L SOUTH WALL WEST WALL CEILING <br /> RQOM NO ROOM NAME MATL FIN CLR FlN CLR MATI FIN CLR MATL FIN CLR MATL FlN CLR MATL FIN CLR MATL FIN CLR CODED NOTES PLAM ROOM NO PERiMETER MULLION <br /> 230 WAITING CONC (E) CPT - RB - GYP PT - GYP PT - GYP PT - (E) - - (E) - - - - 230 D E FAU LT F RAM E O F F S ET <br /> 23, SE� �oN� (E) CPT - RB - GYP PT - GYP PT - GYP PT - GYP PT - (E) - - - - 231 AT CC�RNERS HM FRAME REFERENCE DIMENSIONS <br /> 232 QFFICE CONC (E) CPT - RB - (E) PT - (E)/GYP PT - GYP PT - GYP PT - (E) - - - - 232 N TS N TS NOTE: RABBETS VARY - SEE DETAILS. <br /> 233 OFFICE CONC (E) CPT - RB - GYP PT - GYP PT - GYP PT - (E)/GYP PT - (E) - - - - 233 �n �, <br /> 234 OFFICE CONC (E) CPT - RB - (E) PT - GYP PT - GYP PT - GYP PT - (E) - - - - 234 <br /> 235 ALCOVE CONC {E) CPT - RB - GYP PT - GYP PT - GYP PT - GYP PT - (E) - - - - 235 PROVIDE A1 OR M BACKER FOR SIGN <br /> 237 HALLWAY CONC (E) CPT - RB - GYP PT - GYP PT - GYP PT - GYP PT - 3/4" RAISED <br /> (E) - - - - 237 ADHESION TO GLAZING. SIZE BACKER I � Z LETTERS <br /> 240 ACHIEVE CONC (E) CPT - RB - PLYWD PT - PLYWD PT - PLYWD PT - PLYWU PT - (E) - - - _ 24,p TO MATCH SPEClFIED SIGN. J �" RAISED <br /> 240A QUIET CONC (E) CPT - RB - PLYWD PT - PLYWD PT - PLYWD PT - P�YWp PT - (E) - - - - 240A C L A S S R 00 M ��MBERS <br /> �'-o~ � <br /> 241 ACHIEVE CONC (E) CPT - RB - PLYWD PT - PLYWD PT - PLYWD PT - PLYWD PT - (E) - - - - 241 GRADE 2 <br /> 241A QUIET CONC (E) CPT - RB - PLYWD PT - PLYWD PT - PLYWD PT - PLYWD PT - (E) - - - - 241A �� i� BRAI�LE, TYP 715t GISTERED <br /> 242 ACHIEVE CONC (E) CPT - RB - PLYWD PT - PLYWD PT - PLYWD PT - PLYWD PT - (E) - - - - 242 � SLIDE-IN ITECT <br /> 242A QUIET CONC (E) CPT - RB - PLYWD PT - PLYWQ Pi - PLYWD PT - PLYWD PT - (E) - - - - 242A =� �S MS. CRABAPPLE INSERT PANEL <br /> 331 COACH (E) (E) - - - (E) - - (E) - - (E) - - (E) - - (E) - - - - 331 �, � KE P. AGAN <br /> ��I C �-��D 1�/A�� � �C lT S(G�t�(�� `'' ��P�S� Lt�(T-rl�p, � TYPE A: STATE OF NVASHIN�TON <br /> ___' <br /> �.- �V 12'E D .�`(" �1K�� lx�� <br /> CLASSROOM SIGN (NTS) <br /> ,-,..x--„�-----1 . O <br /> - �—�L��� � �f � S I G N LOCATE <br /> � � � �. : , o DETAIL #1 <br /> _ , � <br /> � i � Scale: 1 f 4" = 1'-0" <br /> � � �--� � '------ <br /> INSTAI.L SALVAGED 3'X6' R L_J / <br /> 11'-t1" BOOK CASES FROM (E) 3�0� �i � � ��� / <br /> LIBRARY, TYP. .rYP � Q <br /> / <br /> - �-�, � <br /> , � <br /> �� � � � i � � DOOR SCHEDULE GENERAL NOTES <br /> �, � �, ABBREVIATIONS <br /> � 1. ALL DOORS TO BE 1�4" THiCK, UNO. BF BOTTOM OF FRAME NTS NOT TO SCALE � <br /> INSTALL (3) SALVAGED / <br /> 9'-0� DOUBLE SIDED 5'H TEXT � (E) EXISTING OF OUTSIDE OF FRAME <br /> � � �� 2. INSTALL SALVAGED <br /> ________ (E) DOUB�E PORTABLE SPACE BOOK/NOVEL STORAGE (E) DOOR. FF FACTORY FINISH OP OPERABLE WAL� <br /> j j FROM (E) LIBRARY. O CONTRACTOR TO REMOVE & RELOCATE (E) DOORS FROM F1N FINISH PG PLEXI GIASS <br /> i i ; I� OTHER (E) BLDG ON CAMPUS. AREAS TO BE DETERMINED. FLR FLOOR PL PLASTIC LAMtNATE � <br /> U � CG CORNER GUARD PR PAIR OF DOORS '�'J <br /> � CLEAR SPACE � _ 3. GLAZING DIMENSIONS FOR DOOR TYPES ARE TO INSIDE OF GL GLASS PT PAINT G. <br /> i F4R TABLE i o FRAME CLEAR GLAZING AREA . GYP GYPSUM WALL 80ARD RB RUBBER BASE <br /> STORAGE i I �` ( � H HINGE JAMB S SIRIKE JAMB � <br /> i i r' '' 4. S T R I K E J A M B D E T A I L I S S I M I L A R T O H I N G E J A M B H M H O L L O W M E T A L SS STAINLESS STEEL � <br /> i i _ �.�, DETAIL, UNO. HR HQUR ST� STEEL F.. <br /> I I STC STEEL CLAD DOOR <br /> i i ' fGU INSUL GLAZING UNIT � <br /> L_________J �_ � � � 5. VERIFY WALL CONSTRUCTION FOR FRAME DEPTH. KD METAL KNOCK DOWN FRAME TG TEMPERED GLASS <br /> LG LAMINATED GLASS UNO UNLESS NOTED OTHERWISE <br /> ' 7. ALL DOOR HARDWARE SHOULD COMPLY WITH 'ADA' MATL MATERIAL WG WIRE GLASS �� <br /> '"""`�" �� REQUIREMENTS. SEE SPEC FOR HARDWARE SET MB MARKERBOARD (IMPACT RESISTANT) � <br /> � INFORMATION. MTL METAL ACTURER WD WOOD <br /> a 8. VERIFY EXISTING WALL CONSTRUCTION FOR FRAME <br /> � <br /> O� DEPTHS. � <br /> 9. INSTALL STEEL CI.AD DOOR W/ METAL KNOCK DOWN C' <br /> N N FRAME. <br /> 2 FURNITURE PLAN DOUBLE PORTABLE KEYP PLAN <br /> � <br /> Scale: 1 f8" = 1'_0" � <br /> N TS <br /> � � <br /> � <br /> —Ti_—"__-`� 1I— � <br /> � `��/�� ..� —SEE FLOOR PLANS FOR DOOR AS � <br /> SALVAGED DR II Ij <br /> SCHEDULED �� II CONCRETE � <br /> �� ' WALL TYPE, TYP. �� �� <br /> ��--� �� DR FRAME PER SCHED I� I� �� <br /> ��\ HEADER PER STRUCT VCT OR SPORT �� �� VINYL REDUCER <br /> � � <br /> FLOORING �L_____Jj SECURED TO O � <br /> ��� SEALANT - TYP. � <br /> ----- SLAB <br /> �.,.� . o <br /> o a � a � ' O � � <br /> �__ BATT INSULATION, �rrnrn. -�� � DOUBLE STUD, rw " ° ^ � ` ROOM FINISH SCHEDULE C4DED NOTES U Q <br /> i , DR FRAME PER SCHED � � VCT TO CONCRETE � � � <br /> � � G A � <br /> � <br /> � � � DOOR PER SCHED r�`" —T�-'� � VCT OR SPORT 1Q PATCH/REPAIR (E) FLOOR FINISH & BASE AS REQD FOR NEW _J � W <br /> I I I ---------�� DOOR AS �� �� FL04RING CONSTRUCTION. (� a <br /> I II --T----r - ' SCHEDULED----�� II � w <br /> U �I VINYL CARPET 2 MATCH E PT COLOR � � Q <br /> I I I NOTE: REFER TO SHT A3.7 � CPT OR I� II Q ( } <br /> ADAPTER SECURED � <br /> � � � �L____Jj TO SLAB W � z <br /> FOR HM FRAME REFERENCE WOM � �� � � <br /> � EQ �, I_ EQ I. DIMENSIONS WALL TOPE, Pnp S FOR � � _ <br /> -�r--,�- -,�---,i�- � � <br /> TYP INT DOOR HEAD , a � , � ° ° Q e _ ABBREVIATIONS ROOM FINISH SCHEDULE GENERAL NOTES W � � <br /> TYP INT DOOR JAMB N <br /> 3 SCALE: 3"=1'-0" �0004 � SCALE: 3"=1'-0" i0005 CARPET TO VCT ACT ACOUSTICAL CEILING TILE 1. AN ASTERISK (*) IN THE FINISH SCHEDULE REFERENCES CODED <br /> B CLR COLOR NOTES IN THE REMARKS COLUMN. <br /> �T�� —T►— VCT OR CONC CONCRETE <br /> CPT CARPET 2. AT ALL ROOMS AND/ OR CORRIDORS TURNED AT A 45' ANGLE, THE <br /> DOQR AS �� �I SHEET VINYL EM ENTRY MAT <br /> NORTH WALL REFERENCE ON THIS FINISH SCHEDULE REFERS TO THE <br /> VCT aRLED---fi ii (E) EXISTING NORTHWEST WALL IN PLAN. <br /> METAL THRESHOLD FAF FLUID APPLIED FL.00RING <br /> SHEET I� I� SECURED TO SLAB FWC FABRIC WALL COVERING 3. ALL FLOORING/ COLOR TRANSITIONS, WHERE REQD, SHALL BE <br /> VINYL �L==__-Jj FIN FINISH CENTERED UNDER DOOR. <br /> GYP GYPSUM BOARD <br /> � � � KD METAL KNOCK DOWN FRAME 4. ALL GYP, PLYWD WALLS ARE PAINTED W/ SHERWIN WILLIAMS SW <br /> I� �_I � 7014 EIDER WHITE. <br /> � �\��� � � � _ a MATL MATERIAL <br /> `� � � ° � s MB MARKERBOARD <br /> �I4 ' \ \ " � " MDF MEDIUM DENSITY FIBERBOARD 5. F1.00RING MATERIAL IS EXISTING CONC UNO. <br /> I PL PLASTIC LAMINATE <br /> • LINTEL � �� <br /> � \ � � (E) CMU, FV VCT TO VCT PWP PLASTIC WALL PROTECTION 6. PAINT ALL DOOR FRAMES PAINT W/ SHERWIN WILLIAMS SW 7014 <br /> PLYWD PLYWOOD EIDER WHITE. <br /> i'/ CUT 1/2"D DRiP EDGE, � E `�� CUT TO PROVfDE DRIP <br /> � PATCH (E) HERDER AS \ � � EDGE —Tri��-- PT PAINT <br /> I . I\ RB RUBBER BASE 7. ALL EXISTING WOOD WALL PANELS TO REMAIN ARE TO BE PRIMED /� R C H I T E C T U R E <br /> NEEDED, TYP. I� II <br /> ,t..__._._.._____:.__: _ [ _______�I_ �� �� SLR SEALER AND PAINTED TO MATCH WALL COLOR. <br /> \-- -�---� f <br /> ` STC STEEL CLAD nacarchitecture.com <br /> ,\ � � I \ I�` � I� I� MARBLE TRANSITION TBS TO BE SELECTED 8. TYP RUBBER BASE FlNISH IS JOHNSONITE CEMENT 121. 2025 FIRSTAVENUE � SUITE 300 <br /> � �� / � � � .I �I \ VCT U II THRESHOLD <br /> \ I� II VCT VINYL COMPOSITION TILE SEATTLEWA98121 <br /> � � �. , \ \ �� L�—===-=-�J VWC VINYL WALL COVERING 9. PROVIDE ENTRY MAT � RM 236, 240, 241, 242. P,206,441.4522 <br /> r---f---j--- <br /> ,�;. - WD WOOD <br /> - KD HEAD i I I � n ^ a � ' � .: '°::. '~'.a��:�a '`. NAC NO 121-16027 <br /> o �_=J 5-1/2 KD JAMB � � - oRawN CLC <br /> 1" �" <br /> � <br /> � D VCT TO CERAMIC TILE �HE�KEo MG <br /> � „ � PATCH (E) FiN AS <br /> 5� v 2" NEEDED, PT TYP. DATE 06-0I-2017 <br /> NOTES: <br /> STC aR, PT TYP. 1. REFER TO ROOM FINISH SCHEDULE & PLANS <br /> • STC DR, PT TYP. <br /> FOR SPECIFIC FLOOR FINISHES. <br /> 2. REFER TO DOOR HARDWARE SETS FOR OTHER <br /> ROOM FINISH, <br /> SPECIFIED TRANSITIONS / THRESHOLDS. <br /> DOOFt TYPES, <br /> SCHEDULES, <br /> FURNITURE PLAN & <br /> YP EXT D04R HEAD @ (E) CMU � TYP EXT DOOR JAMB @ (E) CMU TYP FLOOR TRANSITIONS bETAILS <br /> 6 SCALE: 3"=1'-0" 1°001 � p ► p ID001 � „ , „ <br /> SCALE: 3 =1 —0 SCALE: 6 =1 —0 i000� <br /> � <br /> � <br /> � <br /> Q <br /> z <br /> � <br /> N • <br /> � <br />