Simple Heating System Size: Washin ton State <br /> This heatinq svstem sizina calculator is based on the Prescriptive Recauirements of the 2012 Washinaton State Enerqy Code(WSEC)and ACCA <br /> Manuals J and S This calculator will calculate heatinq loads onlv ACCA procedures for sizinq cooling systems should be used to determine coolinQ <br /> loads. <br /> The glazing(window)and door portion of this calculator assumes the installed glazing and door products have an area weighted average U-factor of <br /> 0.30. The incorporated insulation requirements are the minimum prescriptive amounts specified by the 2012 WSEC. <br /> Please fill out all of the green drop-downs and boxes that are applicable to your project.As you make selections in the drop-downs for each section, <br /> some values will be calculated for you. If you do not see the selection you need in the drop-down options,please call the WSU Energy Extension <br /> Program at(360)956-2042 for assistance. <br /> Project Information Contact Information <br /> Plan 2006 <br /> Heatinp Svstem Tvpe: O Forced Air Furnace Q Heat Pump <br /> To see detailed instructions for each section,place your cursor on fhe word"Instructions". <br /> Desiqn Temperature <br /> E`'���"b�°°"� Design Temperature Difference(4T) 49 <br /> Everett Paine AFB � � <br /> � :,, �.;�, �T=Indoor(70 degrees)-Oufdoor Design Temp <br /> Area of Buildinq <br /> Conditioned Floor Area <br /> '�'��'��'r°"��'`� Conditioned Floor Area(sq ft) 2,006 <br /> Average Ceiling Height Conditioned Volume <br /> �"`"£"`"'`;"`� Average Ceiling Height(ft) 8.5 17,051 <br /> Glazinq and Doors U-Factor X Area = UA <br /> €""�"�``°'�' 0.30 334 100.05 <br /> Insulation <br /> Attic U-Factor X Area = UA <br /> �'''���'�`'`"� Ray . � 0.026 1,431 37.21 <br /> ��:.c:..; :_...... - <br /> Single Rafter or Joist Vaulted Ceilings U-Factor Area UA <br /> (r�s;ruCt�c>nv � 9 � ` � <br /> � ... Project. � : j --- <br /> No Vaulted Ceilin s in th�s <br /> � .:�" <br /> S .�.r�iv�.r. <br /> Above Grade Walls�SeeF�y,.reT� U-Factor Area UA <br /> [n�tr�cl�.;u��. . , . ... . . ._----_._..---.�.�_. : <br /> R-zl . ' 0.056 2,390 133.84 <br /> � r� J <br /> Floors U-Factor Area UA <br /> ,u . ,___.__._.____..__.___._ _�._ � 0.029 1,300 37.70 <br /> ir�s,t.s;ac:i^ri�, � <br /> ,R-30 � <br /> (. `�r::-.�:.:...: .. -- .�,. <br /> Below Grade Walls�see Fry�.e�� U-Factor Area UA <br /> (ns;,::;,;;,;r.; ---- � <br /> 'No Below Grade Walls in this projecL � �{ --- "- <br /> __ __�____._._._.—_ .:=F�':e5.�.,i <br /> Slab Below Grade/5ee Fry�re» F-Factor Length UA <br /> ii1S�#�:i<^.'IC'it_^� _--' R ___ � <br /> �`No Slab 8elow Grade in this project. � . } <br /> ��- ... . . ..::..;_�.....>�. ..... i�aae� <br /> Slab on Grade�5ee Fry�.e�� � F-Factor Length UA <br /> !a-:sY¢�:�cetc�G�s - � � � ----� G � <br /> �No Slab on Grade in this projed. � <br /> �t.:..._;.,t;-.�� � ��=� --�e.�-_....._.w . � :� <br /> .._..� `��¢-- - <br /> Location of Ducts <br /> `�"`�'���''�"`�' � Duct Leakage Coefficient <br /> �Umm�ditioned Space � <br /> '',�.v�:,��:� ���:;��= . 1.10 <br /> Sum of UA 308.80 <br /> Envelope Heat Load 15,131 Btu/Hour <br /> Fi ure 1. s�moruaxoT <br /> ��4� Air Leakage Heat Load 9,023 Btu/Hour <br /> , VolumeX 0.6XdTX.o18 <br /> AboveGrade Building Design Heat Load 24,154 Btu/Hour <br /> ~�� Air Leakage+Envelope Heaf Loss <br /> ' � Building and Duct Heat Load 26,570 Btu/Hour <br /> Ducfs in unconditioned space:Sum of Building Heat Loss X 1.10 <br /> Ducfs in conditioned space:Sum of Building Heat Loss X 1 <br /> Maximum Heat Equipment Output 37,198 Btu/Hour <br /> Building and Duct Heat Loss X 1.40 for Forcetl Air Fumace <br /> 8uilding and Duct Heat Loss X 125 for Heaf Pump <br /> (07/01/13) <br />