My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
9507 3RD AVE SE LOT 9 2014 Plans 2022-12-05
>
Address Records
>
3RD AVE SE
>
9507
>
Plans
>
9507 3RD AVE SE LOT 9 2014 Plans 2022-12-05
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/5/2022 8:44:40 AM
Creation date
7/12/2018 3:46:11 PM
Metadata
Fields
Template:
Address Document
Street Name
3RD AVE SE
Street Number
9507
Unit
LOT 9
Permit
C1403-014
Year
2014
Notes
RB1403-002 NEW SFR
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
54
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
� Table R402.1.1 Footnotes <br /> For SI: 1 foot .= 3Q4.8 mm, ci .= continuous insulation, int .= intermediate framing. <br /> a R-values are minimums. U-factors and SHGC are maximums. When insulation is installed in a cavity which is <br /> less than the label or design thickness of the insulation,the compressed R-value of the insulation from <br /> Appendix Table A101.4 shall not be less than the R-value specified in the table. <br /> b The fenestration U-factor column excludes skylights. The SHGC column applies to all glazed fenestration. <br /> Exception: Skylights may be excluded from glazed fenestration SHGC requirements in Climate Zones 1 <br /> through 3 where the SHGC for such skylights does not exceed 0.30. <br /> `"10/15/21.+T6" means R-10 continuous insulation on the exterior of the wall, or R-15 on the continuous <br /> insulation on the interior of the wall, or R-21 cavity insulation plus a thermal break between the slab and the <br /> basement wall at the interior of the basement wall. "10/15/21.+TB" shall be permitted to be met with R-13 <br /> cavity insulation on the interior of the basement wall plus R-5 continuous insulation on the interior or <br /> exterior of the wall. "10/13" means R-10 continuous insulation on the interior or exterior of the home or R- <br /> 13 cavity insulation at the interior of the basement wall. "TB" means thermal break between floor slab and <br /> basement wall. <br /> d R-10 continuous insulation is required under heated slab on grade floors. See R402.2.9.1. <br /> e There are no SHGC requirements in the Marine Zone. <br /> f Basement wall insulation is not required in warm-humid locations as defined by Figure R301.1 and Table <br /> R301.1. <br /> g Reserved. <br /> h First value is cavity insulation, second is continuous insulation or insulated siding, so "13.+5" means R-13 <br /> cavity insulation plus R-S continuous insulation or insulated siding. If structural sheathing covers 40 percent <br /> or less of the exterior, continuous insulation R-value sha(I be permitted to be reduced by no more than R-3 in <br /> the locations where structural sheathing is used to maintain a consistent total sheathing thickness. <br /> 'The second R-value applies when more than half the insulation is on the interior of the mass wall. <br /> ' For single rafter-or joist-vaulted ceilings, the insulation may be reduced to R-38. <br /> k Int_ (intermediate framing) denotes standard framing 16 inches on center with headers insulated with a <br /> minimum of R-10 insulation. <br /> � Log and solid timber walls with a minimum average thickness of 3.5 inches are exempt from this insulation <br /> requirement. <br /> Table R402.1.3 Footnote <br /> a Nonfenestration U-factors shafl be obtained from measurement, calculation or an approved source or as <br /> specified in Section R402.1.3. <br />
The URL can be used to link to this page
Your browser does not support the video tag.