GORDON HOMES Se tember 30, 2013 SDA Job # 7144 7 <br /> REAR SHEARWALL WIND SEISMIC <br /> Floor Info Tributary Width(Main Roor) Tributary Area(Main Floor) <br /> Main Floor Level,e.g. Upper,Main, Lower 3.o tributary width 3.o tributary area <br /> Lt-Rt Load Direction,e.g. Left-Right, Front-Rear 36.o total width 36.o total area <br /> (Por Left Wall,Use Front-Rear Load Direction) Not US2d NOt U52d <br /> CDX Sheathing type 1.0 tributary width 1.0 tributary area <br /> Values from table 2306.4.1 of the 2006 IBC 2 0 total width 2.0 total area <br /> RoOf � Resisting Dead Load Not Used Not Used <br /> (e.g.Roor.upper Roor,Main Roor) �,0 tributary width 1.0 tributary area <br /> 25.00 ft Total Length of Shearwalls 2.0 total width 2.o total area <br /> V(from upper�= 6840 Ib 4267 Ib Height of Shearwall= 8 5 ft Weight of Shearwall= 10.0 ibs <br /> V(from main)= 0 Ib 0 Ib Length of Shearwall= 4A ft Tributary width for dead load= 15.5 ft <br /> V(from lower)= 0 Ib 0 Ib Length of adjoining wall= 4.3 ft <br /> ?(S2�vfi)= 6,840 Ib z(�'��x)= 4,267 Ib Use alternate R factor for selsmic? No <br /> V= 23 PLF V= 14 PLF <br /> IBC 2306.4.1 1.4 x 0.93 x 260= 339 PLF USE 1 <br /> CTOTAL= (floor above)+(this floor)_ � + �g4 Ibs = �94 Ibs wind controis <br /> TTOTAL= (floor above)+(this floor)_ + -430 Ibs = 430 Ibs Load case e cornrols-Wind <br /> ------ --------------------------- <br /> � Where overstrength factor is applicable,use this NO HOLDOWNS REQUIRED OK <br /> � value for C in e uations 5,6,and 8: E_ �21 �bs ; <br /> �----------------------q----------------------------------------------------------' <br /> GARAGE FRONT SHEARWALL WIND SEISMIC <br /> Floor Info Tributary Width(Main Floor) Tributary Area(Main Floor) <br /> Main Floor Level,e.g. Upper, Main, Lower 11.0 tributary width 11A tributary area <br /> Ft-Rr Load Direction,e.g. Left-Right, Front-Rear 90.0 total width 90.0 total area <br /> (For Left Wall,Use Fronl-Rear Load Direction) Not Used Not Used <br /> CDX Sheathing type 1.0 tributary width �.0 tributary area <br /> Values from table 2306.4.1 of the 2006 IBC 2.0 total width 2.0 total area <br /> Roof Resisting Dead Load Not Used Not Used <br /> (e.g,Roof,Upper Floor,Main Floor) 1 0 t�ibut8ry width 1.0 tributary area <br /> 3.90 ft Total Length of Shearwalls 2.0 total width 2A total area <br /> V(from upper)= 13750 Ib 4267 Ib Heighi of Shearwall= 6.5 ft Weight of Shearwall= 10.0 Ibs <br /> V(from main)= 0 Ib 0 Ib Length of Shearwall= 1.9 ft Tributary width for dead load= 3.0 ft <br /> S V(from lower)= 0 ib 0 Ib �. Length of adjoining wall= 4.3 ft <br /> + ��(�2ivS)= 13,750 Ib 2;(?.'Fix)= 4,267 Ib Use alternate R factor for seismic? No <br /> V= 431 PLF V= 134 PLF <br /> ;3x framing required��er IE3C; <br /> IBC 2306.4.1 1 4 x 0.93 x 380= 495 PLF USE 2 <br /> CTOTAL= (floor above)+(this floo�)_ + 2801 Ibs = 2801 �bs Wind conlrols <br /> TTOTAL= (floor above)+(thi5 f100�)_ � + 2549 Ibs = 2549 Ibs Load case 6 controls-Wind <br /> ' �------ ------- -------- -------- ---- ----------- -- ----� ,�; �. . �.��.. � : ;.. ...:.....:: <br /> 4 <br /> ; 1Nhere overstrength factor is applicable,use thfs USE SIMPSON DESIGNED HOLDOWN: MST48 � <br /> ;_______value for E in ec�uations 5_6_and 8:___________ E= 869 Ibs � OR AT FOUNDATION/INTERIOR WALLS USE: STHD1 O/RJ <br /> GARAGE REAR SHEARWALL WIND SEISMIC <br /> f=loor Info Tributary Width(Main Floor) Tributary Area(Main Floor) <br /> � Main Floor Level,e.g. Upper,Main, Lower 34A tributary width 34.o tributary area <br /> Ft-Rr Load Direction,e.g. Left-Right, Front-Rear 90 o total width 90.o total area <br /> (For Left Wall,Use Front-Rear Load Direction) NOt Used NOt U58d <br /> l_ CDX Sheathing type 1.0 tributary width 1.0 tributary area <br /> Values from table 2306.4.1 of the 2006 IBC 2.0 total width 2A total area <br /> Roof Resisting Dead Load Not Used Not Used <br /> g (e.g.Roof.Upper Floor,Main Floor) 1.0 t�ibutary width 1.0 tributary area <br /> � 14.00 ft Total Length of Shearwalls 2.D total width 2.0 total area <br /> V(from upper)= 13750 Ib 4267 Ib Height of Shearwall= 8.5 ft Weight of Shearwall= 10 0 Ibs <br /> V(from main)= 0 Ib 0 Ib Length of Shearwall= 3.0 ft Tributary width for dead load= 5.o ft <br /> I V(from lower�= 0 Ib 0 Ib = •�. , . ' . Length of adjoining wall= 4.3 ft <br /> � ��(S2ivfi)= 13,750 fb �'(L"µx)= 4,267 Ib Use alternate R factor for seismlc? No <br /> � V= 371 PLF V= 115 PLF <br /> 3x framiny required per IBC <br /> IE3C 2306 4.1 1.4 x 0.93 x 380= 495 PLF USE 2 <br /> CTOTAL= (floor above)+(this floor)_ � + 3�54 Ibs = 3154 Ibs Wind controls <br /> TTOTAL= (floor above)+(this floor)_ + 2770 Ibs = 2770 Ibs Load case f3 controls-wind <br /> - ------ - ----------- ---------------------- -------; _ _.., s : <br /> �p I VVhere overstrength factor is applicable,use this USE SIMPSON DESIGNED HOLDOWN: MST48 � <br /> � value for E in e uations 5,6,and 8 _ E___ `��`��bs � OR AT FOUNDATION/INTERIOR WALLS USE STHD1 O/RJ <br /> a �..-------------------q------------------ <br />