My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
13 115TH ST SE 2015 Plans 2022-11-01
>
Address Records
>
115TH ST SE
>
13
>
Plans
>
13 115TH ST SE 2015 Plans 2022-11-01
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/1/2022 1:15:16 PM
Creation date
7/17/2018 1:54:58 PM
Metadata
Fields
Template:
Address Document
Street Name
115TH ST SE
Street Number
13
Permit
C1502-006
Year
2015
Notes
RB1501-002 NEW SFR
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
46
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Simple Heating System Size: Washington State <br /> This heatinq system sizinq calculator is based on the Prescriotive Requirements of the 2012 Washington State Enerqy Code(WSEC)and ACCA <br /> Manuals J and S.This calculator will calculate heating loads only.ACCA procedures for sizinq cooling systems should be used to determine coolinq <br /> loads. <br /> The glazing(window)and door portion of this calculator assumes the installed glazing and door products have an area weighted average U-factor of <br /> 0.30. The incorporated insulation requirements are the minimum prescriptive amounts specified by the 2012 WSEC. <br /> Please fill out all of the green drop-downs and boxes that are applicable to your project.As you make selections in the drop-downs for each section, <br /> some values will be calculated for you. If you do not see the selection you need in the drop-down options,please call the WSU Energy E�ension <br /> Program at(360)956-2042 for assistance. <br /> Project Information � Contact Information <br /> Plan 2128 <br /> Heatinq System Tvpe: <br /> To see detailed instructions for each section,place your cursor on the word"Instructions". <br /> Desiqn Temperature <br /> � �����0�' �`��� - ------� � � � Design Temperature Difference(oT) 49 <br /> Everett Pame AFB � .3 <br /> � �T=Indoo�(70 degrees)-Outdoor Design Temp <br /> Area of Buildinq <br /> Conditioned Floor Area <br /> ��°""��'�'�"b�`� Conditioned FloorArea(sq ft) 2,12$ <br /> Average Ceiling Height Conditioned Volume <br /> •�_�°� • �°� Average Ceiling Height(ft) 8.5 18,088 <br /> Glazinq and Doors U-Factor X Area = UA <br /> _�:�'°"`��'� 0.30 423 126.90 <br /> Insulation <br /> Attic U-Factor X Area = UA <br /> _. _ . _ , <br /> r� :r;r,4ie:;s R�9 . � 0.026 1,356 35.26 <br /> Single Rafter or Joist Vaulted Ceilings U-Factor Area UA <br /> __ _._.... _._ __� � <br /> .I���'ft^YI�.t'a <br /> No Vaulted Ceilings in this projed. "-- <br /> Above Grade Walls�see Fiyure t� U-Factor Area UA <br /> �P.'::7r;FZ:�'li)riS . ..____....._.__'___"_'_�_'.'"--__.—' 7 <br /> R-zi � 1 <br /> 0.056 2,400 134.40 <br /> .:�.�.--�-- 3 <br /> Floors U-Factor Area UA <br /> i;;�;-:r.':c�z:, -- --------------_____ <br /> R-3o . ' 0.029 1,356 39.32 <br /> _���,�� _�r.:,. 3�:.,.. ;, ; <br /> w�sa..y- —— - <br /> Below Grade Walls�SeeF�y�re» U-Factor Area UA <br /> Et'.,tt'1^..asrnS — ---- ._._ . . .. -._— � � <br /> No Below G2de Walls in this project. � � --- --- <br /> Slab Below Grade(see Figure 1) F-Factor Length UA <br /> i.l?Si.�<t3.:°IC;:S � ___ � <br /> ��.No Slab Below Grade in this project. �..� <br /> , .�:.:s�,.:;�,, � "� <br /> Slab on Grade�see F�y�re�� F-Factor Length UA <br /> . •.'3f;l�?$ .._...___. __...._. ...._... __... ..._ ._._.._..'_"_ . � <br /> No Slab on Grade in this project. • <br /> Location of Ducts <br /> ��'�'"�`°`�='�"y - - Duct Leakage Coefficient <br /> Unconditioned Space �� <br /> � • <br /> , .:- 1.10 <br /> Sum of UA 335.88 <br /> Envelope Heat Load 16,458 etu/Hour <br /> Fi ure 1. somofu,ax�r <br /> ��^°~�� Air Leakage Heat Load 9,572 Btu/Hour <br /> ....,....._,.__.,......,. Volume X 0.6 X dT X.018 <br /> no„�< ,�,de Building Design Heat Load 26,030 Btu/Hour <br /> ... ..,._.,.,. <br /> . Air Leakage+Envelope Heat Loss <br /> Ltelow Gra�e <br /> -• - --•""" Building and Duct Heat Load 28,633 Btu/Hour <br /> Ducts in unconditioned space:Sum of Building Heat Loss X 110 <br /> Ducts in conditioned space:Sum of Building Heaf Loss X 1 <br /> Maximum Heat Equipment Output 40,087 Btu/Hour <br /> Building and Duct Heaf Loss X 1.40 for Fo�ced Air Furnace <br /> Building and Duct Heat Loss X 125 for Heat Pump <br /> (07/Ol/13) <br />
The URL can be used to link to this page
Your browser does not support the video tag.