SCOPE OF WORK GENERAL NOTES: Smart Energy Today Inc; <br /> PHOTOVOLTAIC SYSTEM SUMMARY 1. AN INVERTER OR AN AC MODULE IN AN INTERACTIVE PHOTOVOLTAIC SYSTEM SHALL AUTOMATIC ALL DE-ENERGIZE ITS OUTPUT TO THE _ - SOLAR <br /> CONNECTED ELECTRICAL PRODUCTION AND DISTRIBUTION NETWORK UPON LOSS OF VOLTAGE IN THAT SYSTEM AND SHALL REMAIN IN <br /> SYSTEM SIZE:DC STC-5.22 KW THAT STATE UNTIL THE ELECTRICAL PRODUCTION AND DISTRIBUTION NETWORK VOLTAGE HAS BEEN RESTORED.(NEC 690361). <br /> 2. ALL EXTERIOR ELECTRICAL METALLIC TUBING(EMT)CONDUIT FITTING SHALL BE RAIN TIGHT THREAD-LESS COMPRESSION TYPE. . <br /> MODULES:(18)iTEK ENERGY iT290-SE SOLAR MODULE 3. MODULES AND SUPPORT STRUCTURES SHALL BE GROUNDED. r <br /> MODULE MX POWER(P/MAX):290W 4. NAMEPLATES SHALL BE PROVIDED FOR ALL CIRCUITS IN THE SERVICE DISTRIBUTION AND POWER DISTRIBUTION SWITCH BOARDS,PANEL f 1001 Cooper Point Rd SW. <br /> INVERTER:(9)BLUE FROG SOLAR YC500A-MIW BOARDS.DISCONNECTING SWITCHES,TERMINAL CABINETS,ETC.ALL NAMEPLATES SHALL BE PERMANENTLY ATTACHED AND BE OF j} Suite 140-290 <br /> MICROINVERTER SUFFICIENT CAPACITY TO WITHSTAND THE WEATHER. / , Olympia,WA 98502 <br /> ARRAY TILT:34°,29° 5. JUNCTION BOX/COMBINER BOX HAVE TO USE COMPRESSION TYPE STRAIN RELIEF POSITIONED FOR APPROPRIATE WATER RUN OFF. .[ Phone:888-405-8689 <br /> AZIMUTH:174',84° 6. CONDUIT RUNS SHALL BE PROVIDED WITH SUFFICIENT WEATHERPROOF PULL BOXES OF JUNCTION BOX/COMBINER BOXES PER .0. 3Fax:855-350-9430 <br /> APPROPRIATE NEC REQUIREMENTS. support@smanenergytoday.nel <br /> ELECTRICAL INFORMATION 7. SEE PROVIDED CUT SHEETS FOR ADDITIONAL EQUIPMENT SPECIFICATIONS. <br /> COUNTY:N/A 8. WIRING MATERIALS SHALL BE SUITABLE FOR THE SUN EXPOSURE AND WET LOCATIONS.FIELD APPLIED PROTECTIVE COATINGS ARE NOT ;<.. REVISIONS <br /> UTILITY COMPANY:N/A ACCEPTABLE. , <br /> q DESCRIPTION DATE REV <br /> MAIN SERVICE AMPERAGE:200A 9. JUNCTION,PULL AND OUTLET BOXES LOCATED BEHIND MODULES SHALL BE SO INSTALLED THAT THE WIRING CONTAINED IN THEM CAN BE y <br /> BUILDING INFORMATION:TWO STORY HOUSE RENDERED ACCESSIBLE DIRECTLY OR BY DISPLACEMENT OF MODULE(S)SECURED BY REMOVABLE FASTENERS AND CONNECTED BY A .._ II - - - a INITIAL 00-00,/R, Cr <br /> FLEXIBLE WIRING SYSTEM.(NEC 690.34). a <br /> ROOF:COMPOSITE SHINGLE ° a. <br /> NUMBER OF LAYERS:Si 10. IN AN UNDERGROUND PHOTOVOLTAIC SYSTEM,THE POWER SOURCE SHALL BE LABELED WITH THE FOLLOWING WARNING AT EACH +! , <br /> ANNUAL AVERAGE WIND SPEED:110 MPH JUNCTION BOX,COMBINER BOX.DISCONNECT AND DEVICE WHERE THE UNGROUNDED CIRCUITS MAY BE EXPOSED DURING SERVICE:' + _ <br /> 41112OUND SNOW LOAD:15 PSF WARNING-ELECTRIC SHOCK HAZARD.THE CURRENT CIRCUIT CONDUCTORS OF THIS PHOTOVOLTAIC POWER SYSTEM ARE UNGROUNDED Signature with Seal <br /> BUT MAY BE ENERGIZED WITH THE RESPECT TO GROUND DUE TO LEAKAGE PATHS AND/OR GROUND FAULTS."(NEC 690.35(F)). <br /> 11. ALL PHOTOVOLTAIC MODULES AND ASSOCIATED EQUIPMENT AND WIRING MATERIAL SHALL BE PROTECTED FROM ANY PHYSICAL DAMAGE. <br /> 12. ALL ELECTRICAL DEVICES AND UTILIZATION EQUIPMENT SHALL BE LISTED BY AN APPROVED TESTING AGENCY. 'T •- <br /> 13. OUTDOOR EQUIPMENT SHALL BE AT LEAST NEMA 3R RATED. . <br /> 14. ALL SPECIFIED WIRING IS BASED ON THE USE OF COPPER P <br /> 15. CONTRACTOR SHALL OBTAIN ELECTRICAL PERMITS AND SHALL COORDINATE ALL INSPECTION.COMMISSIONING AND ACCEPTANCE WITH {i: ; <br /> THE CLIENT,UTILITY CO.AND CITY INSPECTORS AS NEEDED. ,;f ....lK='' , <br /> 16. DRAWINGS ARE DIAGRAMMATIC ONLY,ROUTING OF RACEWAYS SHALL BEAT THE OPTION OF THE CONTRACTOR UNLESS OTHERWISE ..,^. <br /> CODE SUMMARY NOTED AND SHALL BE COORDINATED WITH OTHER TRADE. <br /> 2015 WASHINGTON STA I E BUILDING CODE(2015 IBC) 17. IF DISTANCES OF CABLE RUNS ARE DIFFERENT THAN SHOWN,THE CONTRACTOR SHALL NOTIFY ELECTRICAL ENGINEER TO VALIDATE THE %",�.. <br /> 2015 WASHINGTON STAI E ENERGY CODE(20151ECC) WIRE SIZE.FINAL DRAWINGS WILL BE RED-LINED AND UPDATED AS APPROPRIATE. ". PROJECT NAME&ADDRESS <br /> 2015 WASHINGTON STATE RESIDENTIAL CODE 18. WHENEVER A DISCREPANCY IN QUANTITY OF EQUIPMENT.ARISES ON THE DRAWINGS OR SPECIFICATIONS.THE CONTRACTOR SHALL BE <br /> (2015 INTERNATIONAL RESIDENTIAL CODE WASHINGTON RESPONSIBLE FOR PROVIDING AND INSTALLING ALL MATERIAL AND SERVICES REQUIRED BY THE STRICTEST CONDITIONS NOTED ON THE <br /> AMENDMENTS 2014 WAC51-51-2300 SECTION M2302) DRAWINGS OR IN THE SPECIFICATIONS TO ENDURE COMPLETE COMPLIANCE AND LONGEVITY OF THE OPERABLE SYSTEM REQUIRED BY AERIAL VIEW <br /> 2014 WAC 296-468(2014 NEC) THE ARCHITECT/ENGINEERCt <br /> 2015 WASHINGTON STATE MECHANICAL CODE(2015 UMC) 19. ALL BROCHURES.OPERATION MANUALS.CATALOGS.SHOP DRAWINGS.ETC.SHALL BE HANDED OVER TO THE OWNER'S REPRESENTATIVESCALE:NTS <br /> 2015 WASHINGTON STATE PLUMBING CODE(2015 UPC) AT THE COMPLETION OR WORK. PV-0 <br /> UJ <br /> 2015 WASHINGTON STATE FIRE CODE(2015 IFC) 20. ALL WIRING CONCEALED IN WALL AND CEILING SPACES SHALL BE IN METAL CONDUIT. /Il <br /> 21. THE SEISMIC BRACING AND ANCHORAGE OF ELECTRICAL CONDUITS SHALL BE IN ACCORDANCE WITH THE"SMACNA"-GUIDLINES FOR 0 <br /> SEISMIC RESTRAINS OF MECHANICAL SYSTEMS AND PLUMING PIPING SYSTEMS. , <br /> 22. ALL OF THE LISTED SYSTEMS REQUIRED THAT THE SEISMIC LATERAL FORCE F INCLUDING CONSIDERATION OF a"P AND OP BE <br /> SHEET INDEX DETERMINED AT EACH LEVEL OF THE BUILDING SO THAT BRACE SPACING CAN BE CALCULATED.THE DISTRICT STRUCTURAL ENGINEER W <br /> M � OD <br /> CAN APPROVE THE SEISMIC LATERAL FORCE DETERMINATION. W - M <br /> PV-0 COVER SHEET 23. A COPY OF THE CHOSEN BRACING SYSTEM(S)INSTALLATION GUIDE/MANUAL SHALL BE ON THE JOB SITE PRIOR TO STARTING THELo <br /> ;�. �/ 0 <br /> PV-1 PLOT PLAN WITH ROOF PLANS INSTALLING OF HANGERS AND/OR BRACES. - L.L IX N <br /> PV-2 ROOF PLAN WITH MODULES 24. WHEN INSTALUNG DRILLED-IN ANCHORS AND/OR POWDER DRIVEN PINS IN EXISTING NON-PRESTRESSED REINFORCED CONCRETE.USE <br /> PV-3 ATTACHMENT DETAIL CARE AND CAUTION TO AVOID CUTTING OR DAMAGING THE REINFORCED BARS.WHEN INSTALLING THEM INTO EXISTING PRE-STRESSED W CC Cp•,- <br /> PV-4 ELECTRICAL LINE DIAGRAM CONCRETE TENDONS BY USING A NON-DESTRUCTIVE METHOD PRIOR TO INSTALLATION.EXERCISE EXTREME CARE AND CAUTION TO <br /> PV-5 PLACARDS AVOID CUTTING OR DAMAGING THE TENDONS DURING INSTALLATION.MAINTAIN A MINIMUM CLEARANCE OF ONE INCH BETWEEN THE Q <br /> PV-6+ MANUFACTURER SPEC SHEET REINFORCEMENT AND THE DRILLED-IN ANCHOR. Q E v <br /> 25. THE WORKING CLEARANCES AROUND THE EXISTING ELECTRICAL EQUIPMENT AS WELL AS THE NEW ELECTRICAL EQUIPMENT WILL BE <br /> MAINTAINED IN ACCORDANCE WITH NEC 110.26. J W <br /> 26. CONDUCTORS EXPOSED TO SUNLIGHT SHALL BE LISTED AS SUNLIGHT RESISTANT.(NEC 300.6 01,310.8 D. _. W N Z <br /> 27. GROUNDING BUSHINGS ARE REQUIRED AROUND PRE-PUNCHED CONCENTRIC KNOCKOUTS ON THE DC SIDE OF THE SYSTEM.(NEC 250.97). I o <br /> 28. THE GROUNDING ELECTRODE CONDUCTOR MUST BE PROTECTED FROM PHYSICAL DAMAGE IF SMALLER THAN#6 COPPER WIRE.(NEC 59171"''-" ' <br /> 250.64 B). 015 > 0- <br /> 29. <br /> 29. GROUNDING ELECTRODE CONDUCTOR WILL BE CONTINUOUS.EXCEPT FOR SPLICES OR JOINTS AT BUSBARS WITHIN LISTED EQUIPMENT. W(NEC 250.64 C). } <br /> 30. RACEWAY FOR GROUNDING ELECTRODE CONDUCTOR SHALL BE BONDED AT EACH END.(CEC 250.64(E). <br /> 31. WHERE ALL TERMINALS OF THE DISCONNECTING MEANS MAY BE ENERGIZED IN THE OPEN POSITION,A SIGN WILL BE PROVIDED WARNING ---( <br /> OF THE HAZARD PER NEC 690.17.34.EACH UNGROUNDED CONDUCTOR OF THE MULT-IWIRE BRANCH CIRCUIT WILL BE IDENTIFIED PER J <br /> PHASE AND SYSTEM PER NEC210.5. W <br /> 32. CIRCUITS OVER 250V TO GROUND SHALL COMPLY WITH NEC250.97&250.92(B)&LAMC 93.250.97. `� <br /> 33. DC CONDUCTORS EITHER DO NOT ENTER THE BUILDING OR ARE RUN IN METALLIC RACEWAYS OR ENCLOSURES TO THE FIRST 1 <br /> ACCESSIBLE DC DISCONNECTING MEANS PER NEC 690.31(E),LAMC 93.690.31(E). <br /> 34. ALL METALLIC FRAME RAILS AND OTHER CURRENT CARRYING METALLIC COMPONENTS(CONDUIT,JUNCTION&PULL BOXES,RACEWAY, <br /> ETC)SHALL BE SOLIDLY GROUNDED PER THE MANUFACTURER'S INSTALLATION INSTRUCTIONS LAMC 93.690.110.3&93.110.3(B). <br /> 35. SCREWS.NUTS,BOLTS&WASHERS THAT ATTACH EQUIPMENT GROUNDING LUGS SHALL BE STAINLESS STEEL LAMC 93.110.3(0). SHEET NAME <br /> 36. NO PIPING.DUCTS OR EQUIPMENT FOREIGN TO ELECTRICAL EQUIPMENT SHALL BE PERMITTED TO BE LOCATED WITHIN THE DEDICATED <br /> SPACE ABOVE THE ELECTRICAL EQUIPMENT. COVER SHEET <br /> 37. ALL FIELD INSTALLED JUNCTION,PULL AND OUTLET BOXED LOCATED BEHIND MODULES OR PANELS SHALL BE ACCESSIBLE DIRECTLY OR <br /> BY DISPLACEMENT OF A MODULE(S)OR PANEL(S)SECURED BY REMOVABLE FASTENERS. <br /> 38. REMOVAL OF A DWP-INTERACTIVE INVERTER OR OTHER EQUIPMENT SHALL NOT DISCONNECT THE BONDING CONNECTION BETWEEN THE SHEET SIZE <br /> GROUNDING ELECTRODE CONDUCTOR AND THE PHOTOVOLTAIC SOURCE AND/OR OUTPUT CIRCUIT GROUNDED CONDUCTOR. <br /> 39. THE ROOF MOUNTED PHOTOVOLTAIC MODULES,PANELS,OR SOLAR VOLTAIC ROLL ROOFING MATERIAL SHALL HAVE THE SAME OR ANSI B <br /> BETTER LISTED FIRE-RESISTANCE RATING THAN THE BUILDING ROOF-COVERING MATERIAL. <br /> 40. ALL ROOF MOUNTED CONDUIT WILL BEA MINIMUM 6"OFF THE ROOF SURFACE. j 11"X 1TI <br /> 2 <br /> VICINITY MAP SHEET NUMBER <br /> PV_ll SCALE:NTS PV-O <br />
The URL can be used to link to this page
Your browser does not support the video tag.