My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1312 MARYLAND AVE 2018-07-18
>
Address Records
>
MARYLAND AVE
>
1312
>
1312 MARYLAND AVE 2018-07-18
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/18/2018 2:54:23 PM
Creation date
7/18/2018 2:54:19 PM
Metadata
Fields
Template:
Address Document
Street Name
MARYLAND AVE
Street Number
1312
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
31
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
111111111k.'-j.4 . <br /> Residential Photovoltaic OTC Permit Application <br /> oivomminA <br /> Contractors can apply for an Over-The-Counter(OTC)permit where the PV system meets the requirements listed <br /> . in this Checklist.All project plans and supporting documentation must be provided on site for the inspector. <br /> --___-_-TCS BE COMPLETED BY APPLICANT <br /> et Project Information • <br /> Property Owner Name: _ Tanya Pitts <br /> Project Address: 1312 Maryland Ave Parcel# 00407801500700 <br /> City: Everett State: WA ZIP: 98203 <br /> Day Phone: (425)258-1860 <br /> Contractor Name Smart Energy Today <br /> Contractor License#: SMARTET870BS <br /> Contractor Day Phone: 360-339-6660 <br /> PV system description <br /> (include manufacturer Installation of residential rooftop pv solar system 7.67kW with micro-inverters <br /> containing automatic rapid shutdown <br /> and model#of PV (26x)Itek Energy IT295-SE-Modules. <br /> modules and (13x)Blue Frog Solar YC500A-MIW-Micro-Inverters <br /> inverters): <br /> °Determine if your project qualifies for expedited permitting: <br /> Yes No <br /> 1. PV system is designed and proposed for a detached one-or two-family dwelling or <br /> townhouse not more than three stories above grade or detached accessory structure that ' ❑ <br /> is code compliant to setbacks and height,or code allows expansion of nonconformity for <br /> solar modules.[IRC 101.2] <br /> 2. Modules on pitched roofs do not exceed the highest point of the roof unless approved by '12' ❑ <br /> . the local jurisdiction. <br /> 3. Rooftop is made from lightweight material such'as a single layer of composition shingles, L' ❑ <br /> metal roofing,lightweight masonry,or cedar shingles. <br /> 4. The installation shall comply with the manufacturer's instructions.[IRC M2302.2] iSil 0 <br /> 5. The installation shall meet the requirements of NFPA 70 National Electric Code,and all <br /> required electrical permit(s)must be obtained from the Authority Havingiurisdiction to 62' 0 <br /> administer the electrical code.[IRC M2302.2] , <br /> 6. The installation shall meet the requirements of the International Fire Code as amended .RI' ❑ <br /> by WA State.[IRC M2302.2] <br /> 7. The PV system is designed for the wind speed of the local area,and will be installed per l2/ Q <br /> the manufacturer's specifications.[IRC M2302.2.1(1)] . . <br /> 8. The ground snow load does not exceed 70 pounds per square foot.[IRC M2302.2.1(2)] iSf 0 <br /> 9. Total dead load of modules,supports,mountings,raceways and all other appurtenances <br /> weigh no more than-four pounds per•square foot.[iRC M2302.2.1(3)] iZ ' 0 <br /> Enter total dead load of system(lbs/ft2): <br /> 10. To address uplift,modules are mounted no higher than 18"above the surface of the Vt, ❑ <br /> roofing to which they are affixed. [IRC M2302.2.1(4)] <br /> e� ) <br />
The URL can be used to link to this page
Your browser does not support the video tag.