i 1 <br /> GENERAL NOTES <br /> FOR WINDOWS WITH OPERABLE OPENINGS MORE THAN 72' Z L <br /> ABOVE THE FINISHED GRADE OR SURFACE BELOW,THE 6 <br /> LOWEST PART OF THE CLEAR OPENING SHALL BE 24' W 2$ <br /> MINIMUM ABOVE THE FLOOR EXCEPTIONS ¢FULLY OPEN y <br /> WINDOWS WHERE A 4'SPHERE MAY NOT PASS THROUGH a z 212 <br /> OR WHERE FALL PREVENTION DEVICES ARE PROVIDED PER ,..., i <br /> ASTM F 2090 OR R612.3. <.`.a• <br /> 24'-O' .1'7 / 24'-0' PROVIDE SAFETY GLASS'PER IRC R308. 5 <br /> an <br /> SKYLIGHTS TO BE DOUBLE PANEL,SHATTER RESISTANT •21 <br /> 3-3' / / APPROVED RIGID PLASTIC,LAMINATED SAFETY GLASS, w ' <br /> FULLY TEMPERED GLASS.HEAT-STRENGTHENED GLASS. i 17,PO <br /> r----, OR WIRED GLASS.PROVIDE 4-11114141.11.1 CURB(OR SELF x ,, <br /> 3'x3'MIN I. I FLASHING ASSEMBLY WITH 3:12 MINIMUM PITCH OR PER 3 <br /> 0/HANG �'G -$ MANUFACTURER INSTRUCTIONS). J W <br /> WISP T : WISP - 7�'MAX STEP -I - — — — — — i— — I I HOSE BIBBS TO BE BACKFLOW PREVENTION AND FREEZE "' <br /> — <br /> �� r I/ .r/r.r, . ,i ,.r./ , ,�,,, ra,.., ., „,v//i .i:,,./a i I " , r I �t RESISTANT.. TYPE - - c.> <br /> 'I% (2)2x6 fiF/2 I - _ I ALLiHOLDDNNS.FRAMING ANCHDRS k S IEARWALI <br /> ', I <br /> I/1 I o .NA IN M T INSPF.TED BEF CO RIN.: <br /> i I I ArnC ACCESS PER R807.1 8°o <br /> I I '-. 2 - I 3° I q - - - O 22'x30'-MINIMUM ROUGH FRAMED OPENING.INSULATE o <br /> • <br /> I )0. I J I STEP I AND WEATHERSTRIP DOOR.12 HEIGHT INSULATION DAM. 0 <br /> , <br /> I FIND -..30'MINIMUM CLEAR HEADROOM. <br /> . .. I j . I I • <br /> .\ I - - - I C TRUSSES TO EIE DESIGNED&MANUFACIUREO PER p a <br /> r 1 .4. I O ANS/TPI 1. DESIGN BY STATE LICENSED ENGR.& s <br /> -5' O =3 o I I r I MANUFACTURED AT APPROVED PUNT. SUBMIT • <br /> TRUSS DESIGN DRAWINGS TO BURDNG OET71OAL FOR �.. <br /> o J APPROVAL PRIOR TO INSTALLATION&SHIP <br /> N M I I DRAWINGS TO JOB STE WITH TRUSSES DESIGN <br /> j - v • 3 DRAWINGS- TO INCLUDE ALL LOADS,LUMBER INFO., <br /> I II I CONNECTIONS,HANGERS,PERMNENT REVD. <br /> I . I 16'Ti 210 0 16'0/, 4 BRACING LOCATIONS,&RELATED!FORMATION AS <br /> SPECIFIED PER 880210.1. TRUSSES TO BE BRACED v <br /> ABIIJTY PER OTRUSS DESIGN DRAWINGS,BULEIING TATION&TO PROVOE LATERAL c <br /> ,'I I PLANS t PER S1ILDING LATERAL ENGINEERING. N <br /> 15 FIELD CUTS OR MODIFICATION OF TRUSSES NOT a <br /> ( I - J - I _ _ ,I I# AND PERMITTED WITHOUT ENGINEER'S CALCS.APPROVAL BY THE-BIDDING/-D o <br /> j PREFAB ROOF TRUSSES 0 24'0/ I :II DEPARTMENT.BOTTOM CHORD OF TRUSSES TO BE ¢ m N <br /> . 4:12 PITCH 124'-0'PATTERN - W o w <br /> 1 HELD OFF OF NON BEARING INTERIOR ALLS WITH <br /> 0 0 0 <br /> - SMPSON STC ROOF TRUSS CLP OR EQUIVALENT. - <br /> 0 <br /> ;; I =1I "' GABLE END TRUSS TO HAVE VERTICAL MEMBERS <br /> I l I I GARAGE I 24•o.°.FOR SIDING. GABLE END TRUSS IO BE <br /> o - SHEATHED:&NAILED PER WALL BELOW. <br /> • ' . -. c I - <br /> 4'CONC <br /> I o: ROOF & ATTIC VEN11LA110N <br /> Jr CORROSION <br /> A I I - I - - SLOPE 36":1•-0"TOE. <br /> R - ALL- RESISTANT METAL MESH.SCREENED TO BE 3)w/ <br /> 0 H1 PER VENT L i <br /> STORAGE ROOM I ; I BLOCK=7.0 SQ.IN.NET AREA(74%). LOCATE VENT _J <br /> OB - - BLOCKS AT CORNERS&EVENLY BETWEEN FOR ATTICS <br /> I I INSTALL VENT BLOCK EA.RAFTER SPACE FOR = <br /> I .i I /. I - CATHEDRAL ROOFS THE MINIMIAI NET FREE (,� <br /> 3 / '`- S /I(�n I \ \J\(\ ' I O I j y` \ . 32, I �.. I THE VENTED.SPACE IXCEP710N: THE MINIMUM NET W CO`�v <br /> „/r �,v C' I I I FREE VENTILATION AREA SHALL BE 1/300 OF THE I� o O'°,�°.. <br /> ® I <br /> .5 in I 'o ;I VENTED.SPACE PROVIDED THE FOLLOWING CONDITION m ,-4c I <br /> j -= - '" - I I I I IS MET:- AT LEAST 40%AND NOT MORE THAN 50% 2 <br /> ij $.I OF THE REQUIRED VENTILATING AREA IS PROVIDED BY I`1 <br /> I I VENTILATORS LOCATED IN THE UPPER PORTION OF r N <br /> I THE ATTIC OR RAFTER SPACE.UPPER VENTILATORS ' �'`,1- <br /> I <br /> I SHALL BE LOCATED NO MORE THAN 3 FEET BELOW L 1_l L <br /> I I THE RIDGE OR HIGHEST PONT OF THE SPACE. Q <br /> ( -I'� MEASURED VERTICALLY,WI H THE BALANCE OF THE <br /> - - . 13 I '�"'o I REQUIRED VENTILATION PROVIDED BY EAVE OR -.- <br /> 0, <br /> I 1$ ,. g<> i CORNICE VENTS.WHERE THE LOCATION OF WALL OR U <br /> §I I _ ° I I �-�3 sem ROOF FRAMING MEMBERS COINFECTS WITH THE c_ <br /> '� 5° Si DO SAF GL I s 16° X 8° O.H. GAR. DR. 3 MORE lE1TION ar 3�FEEUTPeaOW THEE RIDGE OR INSTALLATION <br /> G <br /> (2)2x6 HF#2 -- (2)2U6 02/2 (2)2x6 HF#2 - I? L' 3 J6 x i3'¢24F-V4 Df M-02 ▪ I \ POINT OF THE SPACE SHALL BE.PERMITTED. <br /> ,; 1 _ <br /> N. ° N. N. T r -- -- <br /> �s`r ._...-•- I ^. . EAVE BAFFLES: <br /> 1 304t0SH ZMA TTEPTO 3�103H I BWP12:. T ,,r I ABIIPr FOR.AI BAFFLE SHALLBBE INSTALLEDUS IN VENTEDTO SOFFIT <br /> L,CD ec <br /> A BE INSTALLED ADJACENT TO SOFFIT <br /> 0 ANG 3'-SO)QI Q . 16'-3' / I3,-101¢' AND CAVE VENTS BAFFLES SHALL MAINTAIN AN 7 \ <br /> 6'-3' 3'-0' �3' 5-(1' 3i� 3'-O' : 6'-3' o ..'OPENING EQUAL OR GREATER THAN DIESIMOF THE <br /> I 4x4 P.T.COL d ' 7x15x15 CONC. I " .o VENT.THE BAFFLE SHALL EXTEND OVER THE TOP OF <br /> . - CBSO44 TO FTNG m - FTNG _ THE'ATTIC INSULATION.THE BAFFLE SHALL BE <br /> CK I - - PERMITIED.TO-BE ANY SOLID MATERIAL J <br /> - - - f1- 5 .I. f' TII5 WSEC.R40223 <br /> 3)6x15 24F-V4 DF M-01 ' ' 'x1 <br /> 1 J PRESSURE TREATED - —T • <br /> 2 <br /> 4'-6' , 4'-11' , 4'-11' �, 4'-6. ATTIC VENTILATION <br /> 2'-7' 18'-10, V-7- 2'-7. I. t8.-0. " )5 2.-7' AREA=768 SF � 52, <br /> ,• ,• - / LKS♦ 7 768+150=5.12- SF VENTILATION REQ'D lr� N w <br /> K 24'-0' - - .- 24'-0' - - LOWER PART OF ATTIC: v M Q a <br /> INSTALL 2-AF50 ROOF VENTS NEAR WALL.LME 0.347 SF NET <br /> EA.=.69 SF NET x I <br /> . - - - - - INSTALL 16 VENT BLOO(S'0.0492 SF NET EA.=.79 SF NET ",- <br /> CV M U <br /> UPPER PART OF ATTIC: <br /> FLOOR / ROOF PLAN scAu:r=t-D' FLO R /' FOUNDATION PLAN SCALE r=,'-D- 4.00 NET CONTINUOUS RIDGE VENT 0.125 S NET/FT= I- ©W <br /> 768 S0.FT.BONUS ROOM - 768 SQ.FT.GARAGE - - TOTAL VENTING PROVIDED=5.48 SF. '_ <br /> cT5 <br /> CL.UJ <br /> U opo <br /> ALL EXTERIOR FOOTINGS TO EXTEND <br /> 18' BLW FIN. GRADE MIN. UNLESS <br /> NOTED OTHERWISE. STRIP ALL WOOD <br /> 2 <br /> FORMS.PRIOR TO BACKFILLING. ,-(2/5 <br /> y <br />