My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
9331 5TH DR SE 2014 Plans 2022-11-22
>
Address Records
>
5TH DR SE
>
9331
>
Plans
>
9331 5TH DR SE 2014 Plans 2022-11-22
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/22/2022 3:46:18 PM
Creation date
7/27/2018 2:07:14 PM
Metadata
Fields
Template:
Address Document
Street Name
5TH DR SE
Street Number
9331
Permit
C1412-011
Year
2014
Notes
RB 1411-001 NEW SFR
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
42
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
, Ta61e R402.1.1 Footnotes <br /> For51: 1foot =304.8mm, ci .=continuousinsulation, int: intermediateframing. <br /> ' R-values are minimums. U-facmrs and SHGC are maximums. When insulation is installed in a cavity which is <br /> less than the la6el or design thickness of the insulation,the compressed R-value of the insulation from <br /> Appendix Ta61e AlO1A shall not 6e lessthan the R-value specified in the ta61e. <br /> °The fenestration LLfacmr column excludes skylights.The SHGC column applies to all glazed fenestration. <br /> Exception:Skylights may 6e excluded from glazed fenestration SHGC requirements in Qimate Zones 1 <br /> through 3 wherethe SHGC for such skylights does not exceed 030. <br /> `"10/15/21+T8" means R-10 continuous insulation on the exterior of the wall, or R-15 on the continuous <br /> insulation on the interiorof the wall, or R-21 cavity insulation plus a thermal 6reak 6etween the sla6 and the <br /> 6asement wall at the interior of the 6asementwall. "10/15/21.+T8" shall 6e permitted to 6e met with R-13 <br /> cavity insulation on the interior of the 6asement wall pWs R-5 continuous insulation on the interior or <br /> exterio rof the wall.'YO/13"means R-10 continuous insulation o n the interior or ewterior of the home or R- <br /> 13 cavity insulation at the interiorof the 6asement walL "Te" means thermal 6reak 6etween floor sla6 and <br /> 6asement wall. <br /> ° R-10 continuous insulation is required under heated sla6 on grade floors.5ee R4022.91. <br /> `There are no SHGC requirements in the Marine Zone. <br /> �easement wall insulation is not required in warm-humid locations as defined 6y Figure R301.1 and Ta61e <br /> R301.1. <br /> g Reserved. <br /> ° First value is cavity insulation, second is continuous insulation or insulated siding, so "13.+5" means R-13 <br /> cavity insulation plus R-5 continuous insulation or insulated siding. If struc[ural sheathing covers 40 percent <br /> or less of the exterior,continuous insulation R-value shall 6e permitted to 6e reduced 6y no more than R3 in <br /> the locations where strucmral sheathing is used to maintain a consistent mtal sheathing thickness. <br /> 'The second R-value applies when more than half the insulation is on the interior of the mass wall. <br /> ' For single rafter or joist-vaulted ceilings,the insulation may 6e reduced to R38. <br /> � Int �intermediate framing)denotes standard framing 16 inches on center with headers insulated with a <br /> minimum of R-10 insulation. <br /> � Log and solid tim6er walls with a minimum average thickness of 3.5 inches are exempt from this insulation <br /> requirement. <br /> Ta61e R402.1.3 Footnote <br /> ' Nonfenestration U-fac[ors shall 6e o6tained from measurement,calculation or an approved source or as <br /> specified in Sec[ion R402.13. <br />
The URL can be used to link to this page
Your browser does not support the video tag.