My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
10019 12TH DR SE 2012 Plans 2022-11-09
>
Address Records
>
12TH DR SE
>
10019
>
Plans
>
10019 12TH DR SE 2012 Plans 2022-11-09
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/9/2022 11:23:57 AM
Creation date
7/30/2018 10:31:37 AM
Metadata
Fields
Template:
Address Document
Street Name
12TH DR SE
Street Number
10019
Permit
C1205-006
Year
2012
Notes
RB415 NEW SFR
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
89
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Simple Heating System Size: Climate Zone 1 <br /> P�roject/nformation Contact/nformation <br /> PI ai A222A Premier Communities <br /> 253-848-1440 <br /> Indoor Design Temperature 70 <br /> Outdoor Design Temperature 17 <br /> DE:sign Temperature Difference (oT) <br /> 4T=Indoor-Outdoor Design Temp 53 <br /> Conditioned Floor Area 1913 <br /> Conditioned Volume 16076 <br /> Glazing <br /> Copy Sum of UA from Glazing Schedule 120 <br /> Attic U-Factor X Area = UA <br /> R-49 0.027 647 17.5 <br /> R-38 Advanced 0.026 104 2.7 <br /> Single Rafter or Joist Vaulted Ceilings <br /> U-Factor X Area = UA <br /> �38 Vented _� 0.027I � � <br /> _ —J <br /> Above Grade Walls U-Factor X Area = UA <br /> R-r 21 � 0.0� 2349 131.� <br /> L— <br /> FNoors U-Factor X Area = UA <br /> R-30 0.029 382 11.1 <br /> I I i <br /> Below Grade Walls U-Factor X Area = UA <br /> 2' Depth Walls 0.042 <br /> 3.5' Depth Walls 0.041 <br /> 7' Depth Wails 0.037 <br /> Slab Below Grade F-Factor X Len th = UA <br /> 2' Dept h 0 . � <br /> 3.5' Dept h 0 . � <br /> 7' Depth 0.57 <br /> � <br /> I i <br /> Slab on Grade F-Factor X Length = UA <br /> R-10 2' perimeter 0.54 390 210.6 <br /> R-10 Full - Heated 0.55 <br /> � � <br /> Sum of UA 494 <br /> Envelope Heat Load [ 26162 Btu / Hour <br /> Sum of UA X 4T <br /> Air Leakage Heat Load 9202 Btu / Hour <br /> ((Volume X 0.6)X OT)X.018)) <br /> Building Design Heat Load 35364 Btu / Hour <br /> Air Leakage+Envelope Heat Loss <br /> Building and Duct Heat Load 1.15 40669 Btu / Hour <br /> If ducts are located in unconditioned space:Sum of Building Heat Loss X 1.15 <br /> If ducts are located in conditioned space:Sum of Building Heat Loss X 1 <br /> Maximum Heat Equipment Output 150% 61003 Btu / Hour <br /> Building and Duct Heat Loss X 1.50 <br /> WSEC Prescriptive Worksheet(2010 Edition) <br /> WSUEEP10-010 Copyright 2010 <br />
The URL can be used to link to this page
Your browser does not support the video tag.