Table R402.1.1 Footnotes <br /> For SI: 1 foot .=304.8 mm, ci .= mntinuous insulation, int.=intermediate framing. <br /> � 'R-,alues are minimums. U-factors and SH6C are maximums. When insulation is installed in a cavitywhich is <br /> less than the label or designthickness of the insulation,the mmpressed R-value of the insulation from <br /> Appendix Table A101.4shall not be lessthanthe R-value specified inthe table. <br /> °The fenestration U-factor mlumn exdudes skylights.The SH6C mlumn applies to all glazed fenestration. <br /> Exception: Skylights may be exduded from glazed fenestration SH6C requirements in Climate Zones 1 <br /> through 3 where the SHGC for such skylights does not exceed 030. <br /> `"10/15/21+TB" means R-10 mntinuous insulation on the exterior of the wall, or R-15 on the mntinuous <br /> insulation on the interior of the wall, or R-21 cavity insulation plus a thermal break between the slab and the <br /> basement wall at the interior of the basement wall. "10/15/21.+T6" shall be permitted to be met with R-13 <br /> cavity insulation on the interior of the basement wall plus R-5 mntinuous insulation on the interior or <br /> exterior of the wall. "10/13" means R-10 mntinuous insulation on the interior or exterior of the home or R- <br /> 13 cavity insulation atthe interior ofthe basement wall. "TB" means thermal break betweenfloorslab and <br /> basement wall. <br /> ° R-10 mntinuous insulation is required under heated slab on grade floors.See R4022.9.1. <br /> e There are no SH6C requirements in the Marine Zone. <br /> �Basement wall insulation is not required in warm-humid locations as defined by Figure R30L1 and Table <br /> R301.1. <br /> gReserved. <br /> ° First value is cavity insulation, semnd is mntinuous insulation or insulated siding, so"13+5" means R-13 <br /> cavity insulation plus R-5 mntinuous insulation or insulated siding. If structural sheathing covers 40 percent <br /> or less of the exterior, mntinuous insulation R-value shall be permitted to be reduced by no more than R3 in <br /> the locations where structural sheathing is used to maintain a mnsistent total sheathing thickness. <br /> �The semnd R-value applies when more than halfthe insulation ison the interior ofthe mass wall. <br /> � Forsingle rafter-orjoisrivaWted ceilings,the insulation may be reduced to R-38. <br /> �InL (inlermediate framing) denotes standard framing 16 inches on center with headers insulated with a <br /> minimum of R-10 insulation. <br /> � Log and solid timberwalls with a minimum average thickness of 3.5 inches are exemptfrom this insulation <br /> requirement. <br /> Table R402.1.3 Footnote <br /> ° Nonfenestration U-factors shall be obtained from measurement, calculation or an approved source or as <br /> specified in Section R402.13. <br />