Laserfiche WebLink
���% roect: BelmarkLo ez b : RR sheet#: <br /> I��"a����E'.�'9�� location: Everett,WA date: ivvzoia <br /> �,��Slgil client: LCI ob#: 1487 <br /> .�i�l C <br /> Roof Loads <br /> Dead Load <br /> Sheathinq Joist Beam Min.w/Uplift <br /> Roofing 3.00 psf 3.00 psf 3.00 psf 2.00 psf <br /> Sheathing 1.50 1.50 1.50 1.00 <br /> Insulation 2.00 2.00 2.00 1.00 <br /> Sprinkler N/A NA NA NA <br /> Ceiling 0.00 2.50 2.50 0.00 <br /> Lights 0.00 0.50 0.50 0.00 <br /> Trusses 0.00 2.50 2.50 2.00 <br /> Mechanical 0.00 1.00 1.00 0.00 <br /> Misc 0.50 2.00 2.00 0.00 <br /> Total 7.00 psf 15.00 psf 15.00 psf 6.00 psf <br /> Snow Load Ground Snow Load Pg= Pg= 20 psf <br /> Minimum Roof Snow Load= 25 psf <br /> Exposure Factor Ce= Ce= 1.0 <br /> Thermal Factor Ct= Ct= 1.0 <br /> Design Roof Snow Load Ps= Ps= 14 psf =0.7CeCtIsPg <br /> 25 psf minumum roof snow load controls <br /> Wood Floor Loads <br /> Dead Loads <br /> Sheathinq Joist Beam <br /> Floor Covering 2.40 psf 2.40 psf 2.40 psf <br /> Gyperete 0.00 0.00 0.00 <br /> Sheathing 2.30 2.30 2.30 <br /> Insulation N/A 1.00 1.00 <br /> Sprinkler N!A 025 0.25 <br /> Ceiling N/A 2.80 2.80 <br /> Lights N/A 0.25 0.25 <br /> Joist N!A 2.50 2.50 <br /> Mechanical N/A 0.25 0.25 <br /> Misc 0.00 025 0.25 <br /> Total 4.70 psf 12.00 psf 12.00 psf <br /> Live Loads <br /> Residential 40 psf <br />