My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
9330 4TH AVE SE 2014 Plans 2022-11-22
>
Address Records
>
4TH AVE SE
>
9330
>
Plans
>
9330 4TH AVE SE 2014 Plans 2022-11-22
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/22/2022 3:58:01 PM
Creation date
7/31/2018 8:39:20 AM
Metadata
Fields
Template:
Address Document
Street Name
4TH AVE SE
Street Number
9330
Permit
C1408-019
Year
2014
Notes
RB1408-001 NEW SFR
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
69
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Table R402.1.1 Footnotes <br /> For51: 1foot .= 304.8mm, ci :mntinuousinsulation, int .= intermediateframing. <br /> ° R-values are minimums. U-factors and SHGC are maximums. When insulation is installed in a cavity which is <br /> less than the label or design thickness of the insulation, the mmpressed R-value of the insulation from <br /> Appendix Table A101.4 shal I not be less than the R-value specified in the table. <br /> °The fenestration U-factor mlumn exdudes skylights.The SHGC mlumn applies to all glazed fenestration. <br /> &ception: Skylights may be exduded from glazed fenestration SHGC requirements in Qimate Zones 1 <br /> through 3 where the SHGC forsuch skylights does not exceed 030. <br /> "'10/15/21+T6" means R-10 mntinuous insulation on the exteriorofthe wall, or R-15 on the mntinuous <br /> insulation on the interior of the wall,or R-21 cavity insulation plus a thermal break between the slab and the <br /> basement wall at the interior of the basement wall. "10/15/21+T6" shall be permitted to be met with R-13 <br /> cavity insulation on the interior of the basement wall plus R-5 mntinuous insulation on the interior or <br /> exterior ofthe wall. "10/13" means R-10 mntinuous insulation on the interiororexteriorofthe home or R- <br /> 13 cavity insulation at the interior of the basement wall. "TB" means thermal break between floor slab and <br /> basementwall. <br /> � R-10 mntinuous insulation is required under heated slab on grade floors. See R4021.9.1. <br /> eThere are no SHGC requirements in the Marine Zone. <br /> f Basement wall insulation is not required in warm-humid locations as defined by Figure R301.1 and Table <br /> R301.1. <br /> g Reserved. <br /> ° First value is cavity insulation, semnd is mntinuous insulation or insulated siding, so "13.+5" means R-13 <br /> cavity insulation plus R-5 mntinuous insulation or insulated siding. If structural sheathing mvers 40 percent <br /> or less of the exterior, mntinuous insulation R-value shall be permitted to be reduced by no more than R3 in <br /> the locations where structural sheathing is used to maintain a mnsistenttotal sheathing thickness. <br /> �The semnd R-value applies when more than half the insulation is on the interior of the mass wall. <br /> � Forsingle rafter-orjoist-vaulted ceilings, the insulation may be reduced to R-38. <br /> " Int. (intermediate framing) denotes standard framing lfi inches on center with headers insulated with a <br /> minimum of R40 insulation. <br /> � Log and solid timber walls with a minimum average thickness of 3.5 inches are exempt from this insulation <br /> requirement. <br /> Table R402.1.3 Footnote <br /> ' Nonfenestration U-factors shall be obtained from measurement, calculation oran approved source oras <br /> specified in Section R402.13. <br />
The URL can be used to link to this page
Your browser does not support the video tag.