10200 25TH AVE SE 2017 Plans 2022-12-06
>
Address Records
>
25TH AVE SE
>
10200
>
Plans
>
10200 25TH AVE SE 2017 Plans 2022-12-06
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/6/2022 9:48:54 AM
Creation date
8/7/2018 8:54:09 AM
Metadata
Fields
Template:
Address Document
Street Name
25TH AVE SE
Street Number
10200
Permit
B1706-069
Year
2017
Notes
ADD 1 PORTABLE CLASSROOM WITH RAMP
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
20
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
FASTENING SCHEDULE MATERIAL LIST � <br /> WALLS: FLOOR: <br /> PLATE—TO—STUD � ROOF: <br /> MIN. OF 3— 0.121" x 3" NAILS 2 x 8 FLOOR JOIST—TO—RIM MIN. OF 4— 0.131" x 3" NAILS (SENCO KC27 OR EQUAL) <br /> ROOFING. . . . . .. . . . . . .ARCH. SHINGLES OVER SELF—ADHERED � <br /> VW TACKBOARD—TO—STUD � INTERIOR 16 ga x 2" WIDECROWN STAPLES (SENCO P21) � 6" oc TOP & BOTTOM CLASS "A" BOTTOM BOARD—TO—JOIST 16 ga. x 3/8" WIDE CROWN Q 12"oc MAX. UNDER�AYMENT APPLIED SHINGLE FASHION <br /> AND GLUED IN FIELD <br /> FLOOR DECKING—TO-2x JOIST 0.113" x 2 3/8" RING SHANK C�? 6"oc EDGE, 12"oc FIELD —HIGH WIND APPLICATION— <br /> SHEETROCK—TO—STUD @ INTERIOR 0.091 x 2Y4" NAILS AT 16" oc EDGE AND CONSTRUCTION ADHESIVE IN FIELD. (SENCO GE-24). USE CONSTRUCTION ADHESIVE (AFG01) ON JOISTS <br /> BOTTOM PLATE—TO—FLOOR 0.131' x 3" NAILS � 8"oc (SENCO KC27 OR EQUAL) SHEATHING. . . . . . . . . . .7/16" APA RATED (24/16) MINIMUM <br /> ROOF: <br /> SHEATHING—TO—STUD � SIDEWALL 16 ga. x 1 3/4" STAPLES � 6"oc EDGE, 12"oc FIELD (SENCO N19) FRAMING . . . . . . . . . . . . .2 x 10 DF #2 RAFTERS � 24"oc <br /> ALL EDGES SUPPORTED BY FRAMING OR BLOCKING RIM—TO—RAFTERS MIN. OF 3— 0.131" x 3" NAILS (SENCO KC27 OR EQUAL) w/ 2" FURRING ON BOTTOM FOR R38 <br /> SHEATHING—TO—STUD � ENDWALL SEE ENDWALL FASTENING NOTES ON ELEVATIONS. FURRING—TO—RAFTERS MIN. 4— M20 2 x 3 (MIN.) PLATES EACH SIDE RIDGEBEAM. . . . . . .. . .DOUBLE 1 1/2" x 24" CONTINUOUS LVL 2.OE <br /> ROOF RIM—TO—TOP PLATE 0.131" x 3" NAILS � 8"oc (SENCO KC27 OR EQUAL) LEDGERS. . . . . .. . . . . . .2 x 4 D.F. TAPER CUT <br /> LAP SIDING TO STUD PER MANUFACTURES SPECIFICATIONS <br /> LEDGER—TO—RIDGEBEAM 0.131" x 3" NAILS C�? 3"oc & 3 C� BUTT JOINTS (SENCO KC27 OR EQUAL) RIMS. . . . .. . . .. . . .. . . .2 x 6 CONTINUOUS LVL 2.OE <br /> THREE STUD CORNER CONNECTION 0.131" x 3" NAILS � 12" (SENCO KC27 OR EQUAL) <br /> RAFTER—TO—RIDGEBEAM 4— 0.131" x 3" NAILS (SENCO KC27 OR EQUAL) WITH 2 x 10 DF VENT BLOCKS <br /> AIR BARRIER NOTES: RIDGEBEAM—TO—RIDGEBEAM 4 ROWS C� 0.131" x 3" NAILS Q 12"oc INSULATION. . . . . . . . . .R38 CELLULOSE BLOW—IN OVER CLASS "A" � <br /> MATERIAL (AIR BARRIER COMPONENT) <br /> SHEATHING—TO—ROOF MEMBERS 16 ga x 13/4" STAPLES � 6"oc EDGE, 12"oc FIELD (SENCO N19) -' <br /> THESE KEY AREAS SHALL BE SEALED BY CAULKING, GASKETS, TAPE OR WEATHER—STRIPPING: NOTE: SHEATHING TO BE INSTALLED PERPENDICULAR TO THE RAFTERS. CEILING. . . . . . . . . . . . . .SUSPENDED T—BAR (PER IBC 808.1) <br /> —JOINTS AROUND FENESTRATION (WINDOWS AND DOOR FRAMES): USE APPROPRIATELY SIZED BACKER ROD WITH MINIMUM OFFSET SHEATHING 4 ft. AND BLOCK EDGES OF ANY PIECES LESS THAN 24" <br /> 2" LAP AT ENDS. ARCHITECTURAL . . . . .12" OVERHANG <br /> —JUNCTIONS BETWEEN WALLS AT: MODLINE CONNECTION: NOTE: ALL MODLINES DEFINED AS THE SPACE BETWEEN ADJOINING MODULES <br /> —BUILDING CORNERS: USE CAULKING MUST BE INSU ATED AT THE ROOF, FLOOR AND WALLS ON SITE. ) SOFFIT. . . . .. . . . . . . .. . .FIBER CEMENT PANEL, PERFORATED FOR <br /> —STRUCTURAL FLOORS: USE SILL SEAL OR CAULKING VENTING AS REQUIRED <br /> �— —ROOFS (AT RIM): USE SILL SEAL OR CAULKING <br /> rt —PENETRATIONS OF UTILITY SERVICES THRU THE AIR BARRIER Cs� ROOFS, WAL�S, AND FLOORS: USE CAULKING, SPRAY RIDGEBEAMS 1/2" BOLTS w/ 1Y2" DIA. WASHERS Q 6'-0"oc AND 8" FROM EACH END VENTING. .. . . . . . . .. . .SOFFIT AND RIDGE <br /> �s FOAM, OR AIR BARRIER TAPE. (MINIMUM 2�� EDGE DISTANCE) <br /> � —BUILDING ASSEMBLIES USED AS DUCTS OR PLENUMS: USE BACKER ROD, CAULK, SPRAY FOAM OR AIR BARRIER TAPE. RIM JOISTS 1/2" BOLTS w/ 1Yz" DIA. WASHERS � 4'-0"oc AND 8" FROM EACH END <br /> o —JOINTS, SEAMS, AND PENETRATIONS OF VAPOR RETARDANTS: USE CAULK OR APPROVED TAPE. (MINIMUM 2" EDGE DISTANCE <br /> .. —RECESSED LIGHTING FIXTURES: USE CAULK OR SPRAY FOAM � WALLS: <br /> � SIDING. . . . .. . . . . . . .. .FIBER CEMENT LAP SIDING WITH 8" EXPOSURE . <br /> �� <br /> OVER BUILDING WRAP. BUILDING WRAP TO <br /> \ EXTEND TO BOTTOM OF FLOOR RIM (MIN.) <br /> � MOISTURE . . . .. . . . .WRAP LOWER 12" OF BUILDING & CORNERS WITH <br /> � C B q PROTECTION MOIST—STOP. WRAP BUILDING w/BUILDING WRAP <br /> � 4 6 SHEATHING. .. . . . . . . . .Y2" CDX PLYWOOD (MIN.15/32" RATED SHEATHING) <br /> N <br /> � ' A-4 A-4 <br /> `t � '� \ FASCI A. . .. . . . . .. .. . .1 x 6 <br /> �, <br /> s I TRIM. . .. . . . . .. . . . . . . .1 x 4 AT CORNERS, WINDOWS, DOORS AND ' <br /> � I I ' <br /> 12 <br /> 1 x 6 � MODLINE <br /> J LU26 HANGERS AT ALL RAFTERS �,, 2 3 2 NOTE:2"x 2" GALV. FLASHWG UNDER CORNERS <br /> cv ,f��co OVER DOOR & WINDOW OPENINGS l �_ � _— � A-4 A-4 SHIP LOOSE TO BE INSTALLED ON SITE BY <br /> r� WITH 6— 0.131" x 1�/" NAILS � � i�`I I fll�l ,� OTHERS <br /> �� -� INTO LVL ROOF RIM - 'Y� � � I \` I � � -- <br /> c� '� ' ��� I �� RIDGEBEAM BRACING / I /� I � � FRAMING. . . .. . . . . . . . .2 x 6 D.F. �3 or BETTER STUDS Q 16"oc . <br /> '. � �I\ � �� SEE DETAIL I � \ <br /> � : \�\ � , 5 � � , , <br /> ' TOP PLATE. . . . . .. . . .2 x 6 CONTINUOUS LVL 2.OE <br /> � ` � : � <br /> i i .:;: <br /> T' � ' i A-4 i� � � BOTTOM PLATE. . . . . .2 x 6 D.F. <br /> ___ <br /> i <br /> � � �24 I INSULATION . . . .. . R-21 FIBERGLASS BATTS PLUS ' <br /> _� <br /> �' SEAL <br /> J AT ROOF � 6 FT. WIDE WINDOWS � FLAME SPREAD / Y2" (R3 MIN.) CONTINUOUS FOAM BOARD AT <br /> I RIM/TOP —USE 2— 2x6 D.F. #2 w/ MIN. R10 RIGID FILLER IS 25 OR LESS � ,� INTERIOR SIDE OF EXTERIOR WALLS <br /> � PLATE —USE (2� FULL HEIGHT STUDS AND Q INTERIOR FINISH. . . . . .MATERIAL INSTALLED FROM STUDS OUT <br /> � �1� TRIM STUD AT EA. SIDE OF WINDOW m � EXT. WALLS:LAYER 1: FOAM INSULATION BOARD <br /> �� _ � � LAYER 2: 5/8" TYPE 'X' SHEETROCK (AIR BARRIER) <br /> ,,� �ICO BACKER � ;� o LAYER 3: Y2" VINYLWRAP TACKBOARD (FINISH) <br /> �� � ROD � '; � i <br /> � I AROUND ' '' _ � ABOVE WALL FINISH: LAYER 1: Y2" FOAM BOARD <br /> INTERIOR I � � AT GABLE ENDS LAYER 2: 5/$" SHEETROCK <br /> � � SIDE OF � g ONE DRY CUP PERM VAPOR � <br /> � � WINDOWS I o BARRIER ON THE WARM SIDE, ` <br /> � � , ; � f— i — SKIRTING. .. . . . . . . .. . .SHIP LOOSE <br /> �� AND DOORS � W O TYPICAL THRU—OUT BUILDING. =� <br /> � � ' ! � v m � � GUTTER� . . . . . .. . . . . .PROVIDED AND INSTALLED ON SITE BY OTHERS <br /> � 1 <br /> � N il i o � o = <br /> " CAULK WALL CO � ~ � ' <br /> � CORNERS FROM °° o FLOOR: <br /> � TOP TO BOTTOM � <br /> ' COVERING. . . .. . . , . . , .ON SITE BY OTHERS <br /> �� AT INTERIOR �- �' . <br /> i <br /> �' � DECKING. .. . . .. . . .. . .23/32" APA RATED T&G — GLUED AND NAILED <br /> '� � 7 (AIR BARRIER COMPONENT) <br /> � SEAL r`' <br /> � A-4 <br /> � AT FLOOR i <br /> � RIM/BOTTOM 4 7 FRAMING. . . .. . . . . . . . .2 x 8 DF #2 JOISTS � 16"oc <br /> PLATE � � 1 � A-4 A-4 ' <br /> � , / � / � RIMS. . . . . . . . . . . . . . .. .2 x 8 CONTINUOUS LVL 2.OE ": . <br /> � - \ NOTE:12" HIGH MOISTURE BARRIER INSTALLED ON <br /> � � � '�� � ��� � ��� ������� '���� �Y�� I � � I I�i �I �� � � �II � PERIMETER (OVER GYPSUM) AT RIMS AND END <br /> � � � � � JOISTS <br /> � � �� �� � �� �� JOIST HANGERS. . . .. .AT ALL RIMS � <br /> "� MIDSPAN MIDSPAN <br /> � �» INSULATION. . .. .. . . . .R-30...USE TWO LAYERS OF R-15 <br /> I SUPPORT 2 SPACE SUPPORT UNFACED FIBERGLASS BATT FIBERGLASS <br /> °� REQUIRED REQUIRED <br /> � 6'-11" 6'-11" 6'-11" 6'-11" BOTTOM COVER. . .. . .CLASS A 03/01/2017 . <br /> � 13'-10" 13'-10" G�wa��Tl <br /> � <br /> � � wa : . I���'� <br /> T � � <br /> � <br /> � �� � o <br /> � <br /> � <br /> � <br /> }r <br /> � � S E C T I O N — A A �o� ��G�s°°ER����ww� <br /> 0 1/2" = 1'—0" �SSj�NAL E�� <br /> � <br /> a 1-23-17 PRELIM REVIEW-SP LDG COPYRIGHT 2017, BLAZER INDUSTRIES, INC. � MODULAR Approved for Const: ,Job No: 18869-18873 <br /> �-� 2-23-17 ENGINEERING LDG THIS MATERIAL IS THE EXCLUSIVE PROPERTY Classroom for.� <br /> �n OF BLAZER INDUSTRIES, INC.AND SHALL �� 2$ X 32 KC DA File Copy: ' <br /> �, 2-28-17 � ADD GUTTERS&GUTTER NOTE, REV BOTTOM BOARD LDG NOT BE REPRODUCED, USED,OR DISCLOSED �� - Eve rett S�D■ <br /> �� TO OTHERS EXCEPT AS AUTHORIZED BY THE INDUSTRIES,�Nc. <br /> � i� www.blazerind.com Drawn By: LDG � <br /> � DATE REVISION BY WRITTEN PERMISSION OF BLAZER INDUSTRIES. �� p,o,soxaas ■ Aumsville,OR 97325-0489 WA. GOLD Pacific Mobile 17 BLMP-04 A4 WA Issue Date: 2-28-17 <br /> � <br /> r <br /> O <br /> N <br /> / . <br /> � <br />