My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
10200 25TH AVE SE 2017 Plans 2022-12-06
>
Address Records
>
25TH AVE SE
>
10200
>
Plans
>
10200 25TH AVE SE 2017 Plans 2022-12-06
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/6/2022 9:48:54 AM
Creation date
8/7/2018 8:54:09 AM
Metadata
Fields
Template:
Address Document
Street Name
25TH AVE SE
Street Number
10200
Permit
B1706-069
Year
2017
Notes
ADD 1 PORTABLE CLASSROOM WITH RAMP
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
20
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
#3 VIA PC3 �3,5.7 <br /> #5 VIA PC5 GENERAL NOTES: <br /> 1. WHEN STRANDED WIRE IS USED, ALL TERMINATIONS ARE MADE BY � <br /> A PRESSURE TERMINAL, BY TAILING OFF WITH SOLID CONDUCTORS <br /> (2) 8' x 4' WHITE BOARDS w� 3 5 7 rN OR OTHER APPROVED MEANS OFTERMINATION. <br /> MARKER TRAY (SHIP LOOSE) PCPCPC ELECTRIC <br /> WSTALLED ON SITE BY OTHERS PANEL 2. ALL CONDUCTORS ARE COPPER;TYPE THHN /THWN <br /> t O b T O b � O b 3. RATING OF STANDARD PANEL IS 22,000 A.I.C. <br /> � — � � - - - - - - - - - - � — - - - - - - - - #1 <br /> ( � 4. WIRING METHOD IN METALLIC CONDUIT OR M.C. CABLE. <br /> I <br /> GFCI <br /> � #2�4, 5. HVAC DISCONNECTS SHALL BE LABELED WITH AN IDENTIFICATION <br /> I PLATE SHOWWG CIRCUIT NUMBER AND EQUIPMENT SERVED. <br /> � o � WAC 296-46B-1 10 022 <br /> � �z <br /> � — — — — — — — — — — � o� 6. EXTERIOR WEATHER PROOF GFCI SHALL HAVE A"HEAVY DUTY" <br /> C ` — � r-- - - - - - - - _ � � — � �o <br /> WEATHER PROOF"IN USE"COVER.2014 NEC 406.9(B)(1) ONE-LINE-DIAGRAM <br /> ��`' 200 AMP FEEDER PANEL <br /> l �Q 7. CONTROLLED RECEPTACLES SHALL BE LABELED PER 2014 NEC <br /> 1 O 1 O 1 O � z� MAIN BREAKER <br /> b b b 4 0 6.3(E) W I T H T H E T E X T"C O N T R O L L E D"A N D T H I S S Y M B O L � 120/240 1� <br /> - - - - - - - - - - - - - - - �-- r- — - - <br /> 8. THIS PLAN IS NOT AN"AS-BUILT'CIRCUITS MAY BE RUN DIFFERENT 200 AMP <br /> � THAN SHOWN BASED ON OBSTACLES ENCOUNTERED. <br /> � � <br /> � . <br /> �r � 1/2" PVC 2" PVC STUB <br /> '-n � STUB FOR BY BLAZER <br /> � FUTURE (2) 3/0 Cu THHN <br /> .. � � 51-11 C WAC 2015 WSEC CHAPTER 4 NOTES: cRouN�iNc (�) �/o cu THHN <br /> � � a AND (1) #4 Cu <br /> - - - - - - - - - - - - -- --- - - - - - - - - -- -- � <br /> �� Q BONDING (WIRE ON SITE BY OTHERS) <br /> �-� 5 1. ALL LIGHTWG SHALL CONFORM TO SECTION C405 <br /> N j j <br /> ��, � <br /> � a a a � 2. BASE CLASSROOM LIGHTING POWER DENSITY (C405.4.2.1) <br /> �� I 833 SQ. FT.x 1 WATT PER SQUARE FOOT=833 WATfS ALLOWED <br /> �� � PANEL SCHEDULE <br /> � <br /> ADDITIONAL REDUCTION IN LIGHTING POWER DENSITY (C406.3.1) <br /> ''-� � � � � � <br /> 833 WATTS ALLOWED (BASE) x J5 = 625 WATTS ALLOWED NOTE:ALL CONDUCTORS COPPER. 200 AMP 1� 22,000 AIC <br /> �� <br /> � I TOTAL WATfS ALLOWED= 625 CKT TRIP WIRE VOLT 20O VOLT WIRE TRIP CKT <br /> DESCRIPTION DESCRIPTION <br /> T Q�v TOTAL WATTS INSTALLED —477 WATfS No. a,nnPs size AMPS ��q g�� AMPS sizE AMPS Na <br /> J %OF ALLOWED INSTALLED = 76% 1 uGHTs 20 12 552 — 7244 4 90 HVAC 2 <br /> �� __..__.�_...__._....._......._._ _____________. 3 RECEPTACLES 20 12 1260 �� �� 7244 / / / 4 <br /> � 3. 100%OF LIGHTING FIXTURES HAVE EMBEDDED OCCUPANCY AND 5 RECEPTACLES 20 �2 �oso �� �� --- -- 2o SPARE s ' <br /> N DAYLIGHT SENSORS FOR INCREASED ENERGY SAVINGS, AND ARE 7 RECEPTACLES 20 12 soo �� �� --- -- 2o SPARE s ' <br /> � � INDIVIDUALLY ADDRESSABLE. (C406.4) g ���:,C;r_ - �� �� --- -- 20 SPARE 10 <br /> .>, ,. <br /> � 11 �p;°,�:,�;_ �\ �� ..... 20 SPARE 12 <br /> ,� 4. 100�OF LIGHTING IS SET FOR CONTINUOUS DIMMING AND IS ..... ,..,;.. �1 /'� <br /> 13 :>�;.�v�_ _ _.. — — _ 20 SPARE 14 <br /> °J ADJUSTABLE BY OCCUPANTS, FOR OCCUPANT COMFORT, VIA �� �� 2o SPARE 1s <br /> u 15 S�F��;,'�_ — — <br /> WALL PODS. (C406.4) <br /> � LE TRICAL PLAN �� <br /> �;��.���_ r� �"� _ _... 20 SPARE 18 <br /> Q 5. 50�OF RECEPTACLES ARE CONTROLLED BY LOCAL OCCUPANCY 19 `��'=��;�� -- -- -- �� ��' -- -- 2o SPARE 20 <br /> � 1�4" = 1'-0" ARS 2/21�2017 SENSORS (C405.10) � <br /> � <br /> �, ELECTRICAL SYMBOLS <br /> � <br /> � SYMBOL DESCRIPTION AFF REMARKS <br /> TO TOP , <br /> � XX nLIGHT DIMMING CONTROL DIMMING CONTROL. LOWER CASE <br /> c� �� SWITCH CAT5E CONNECTED 48 LETTERS DESIGNATE ZONWG <br /> a� <br /> � H.V.A.C. (MOTOR, COMPRESSOR, HEATER S�ZES� ELECTRICAL PLAN REVIEW PP PLUG LOAD2CONTROL RELAY CEILOING FIXTUR�LOCCU ANCYH ENSORSED <br /> � OPERATION VOLTAGE 197 MIN. 253 MAX. LOAD CALCULATIONS TR DUPLEX RECEPTACLE 180 VA EACH <br /> � COMPRESSOR 14.6 RLA 112 LRA � HALF CONTROLLED HALF HOT 20 TAMPER RESISTANT <br /> �`� oUTDOOR FAN 1.5 FLA 1/5 H.P. <br /> � INDOOR BLOWER FAN 2.6 FLA 1�3 H.P. VOLTAGE: 120/240 PHASE: 1� �TR QUADPLEX RECEPTACLE 20» 180 VA EACH <br /> HALF CONTROLLED HALF HOT TAMPER RESISTANT <br /> _,� HEAT STRIP 10 KVA CONNECTED LOAD CALC. LOAD <br /> °� MINIMUM CIRCUIT AMPS 8'I AMPS � SINGLE RECESSED CLOCK 84�� 180 VA EACH <br /> � <br /> LIGHTING HANGER RECEPTACLE <br /> u MAXIMUM OVERCURRENT PROTECTION 9O AMPS NOTE: ALL DEVICES 8c FACE EXTERIOR 75 VA x 125 % = 94 VA �c ci RECEPTACRESISTANT GFCI 20�� 180 VA EACH <br /> � OVERCURRENT PROTECTION— DUAL ELEMENT TIME DELAY FUSE PLATES TO BE IVORY . <br /> � OR HACR CIRCUIT BREAKER INTERIOR 477 VA x 125 % = 596 VA 4" SQ BOX SINGLE GANG MR WITH <br /> � , PHONE / DATA BOX 20�� 3/4" CONDUIT UP AND DOWN <br /> � <br /> � QTY. SIZE DESCRIPTION RECEPTACLES � FIRE ALARM PULL STATION 48" <br /> � THRU 10,000 3240 VA x 100 % = 3240 VA 4" SQUARE BOX w/ SINGLE GANG MUD <br /> ELECTRICAL PANEL 1 200 120/240V — SINGLE PHASE — STUB THRU — METALLIC RACEWAY SYSTEM � FIRE ALARM INTERIOR RING — 3/4" RACEWAY STUB UP ONLY <br /> ' HORN STROBE 84 PAINT BOX, MUDRING AND RACEWAY <br /> I OVER 10,000 0 VA x 50 % = 0 VA � <br /> �3' 9 2 x 4 LED VOLUMETRIC TROFFER— nLIGHT ENABLED— 6000 LUMEN— 53 WATTS— 4000K "RED" IN CO�OR <br /> � MOTORS, COMPR. FIRE ALARM EXTERIOR <br /> � WITH EMBEDDED OCCUPANCY AND DAYLIGHT SENSORS COMMUNICATING ON CAT5E � HORN / STROBE 84 . <br /> LIGHTING LOCAL NETWORK LITHONIA - BLT460LADPEZ1LP840N100NES7ADCX TOTA� 4488 VA x 100 % = 4488 VA <br /> � 4" SQ BOX SINGLE GANG MR WITH <br /> c� LARGEST (3504) VA x 25 % = 876 VA O THERMOSTAT 48 1/2" CONDUIT STUB UP <br /> 1 72 WATT LED WALL PACK w/ INTEGRAL PHOTOCELL ECONOLIGHT E-WP11 L07CZ / E-ACP1 <br /> � HEATING 10000 vA x 100 / = 10000 vA � <br /> � HVAC 1 3 TON 10 KW BARD WALL HUNG HEAT PUMP w/ ECONOMIZER- 10 EER RATED �ED WALL PACK 84" 75 VA EACH <br /> � <br /> � nLIGHT ENABLED LED TROFFER <br /> THERMOSTAT 1 HONEYWELL VISIONPRO TH8320R1003 W/ MICROPROCESSOR— 7 DAY PROGRAMMABLE TOTAL KVA �H.2H TOTAL KVA 19.Z7 � W� INTEGRAL SENSORS CEILING 53 VA EACH <br /> � AUTOMATIC SETBACK— DEADBAND CONTROL <br /> CONNECTED CALCULATED <br /> � 1 BARD CMH-28 LOAD AMPS 76,1 7 LOAD AMPS 80,28 S ELECTRICAL PANEL 72" <br /> 0 <br /> � <br /> �n <br /> a 1-23-17 PRELIM REVIEW-SP LDG COPYRIGHT 2017, BLAZER INDUSTRIES, INC. � MODULAR Classroom for.� Approved for Const: Job No; 18869-18873 <br /> � 2-21-17 ELECTRICAL ENGINEERWG ARS THIS MATERIAL IS THE EXCLUSIVE PROPERTY <br /> � OF BLAZER INDUSTRIES, INC.AND SHALL ■■ File Copy: " <br /> �, 2-24-17 ENGINEERING REVIEW HEM NOT BE REPRODUCED, USED, OR DISCLOSED � 2$ X 32 KC DA - Eve rett S■D■ <br /> � �� INDUSTRIES,INC. <br /> '= TO OTHERS EXCEPT AS AUTHORIZED BY THE �� www.blazerind.com Drawn By: LDG � <br /> ° DATE REVISION BY WRITTEN PERMISSION OF BLAZER INDUSTRIES. �� p,0.BOX489 ■ ,4umsvi�le,OR 97325-0489 W/4. GOLD Pacific Mobile 17 BLMP-04 A4 WA Issue Date: 2-10-17 <br /> � <br /> � � <br /> 0 <br /> N <br /> / <br /> (1' <br />
The URL can be used to link to this page
Your browser does not support the video tag.