Laserfiche WebLink
BEARING AND/OR BEARING AND/OR BEARING AND/OR BEARING AND/OR <br /> SHEARWA�L PER PLAN SHEARWALL PER PLAN SHEARWALL PER PLAN SHEARWALL PER PLAN , <br /> � <br /> PLATE NAII.ING PER PLATE NAILING PER PI�ATE NAILING PER PLATE NAILING PER � <br /> (3) 0.148" X 3" SHEARWALL SCHEDULE SHEARWALL SCHEDULE SNEARWALL SCHEDULE SHEARWALL SCHEDULE � <br /> 0.148"X3.25" � 6" O.C. MIN. 0.148"X3.25" C� 6" O.C. MIN. 0.148"X3.25" � 6" O.C. MIN. 0.148"X3.25" � 6" O.C. MIN. 4'-0" �; <br /> ; ' � � <br /> FLOOR SHEATHING AND NAILiNG y EDGE NAI�ING PER SCHED. FLOOR SHEATHING AND NAILING ► EDGE NAILING PER SCHED. FLOOR SHEATHING AND NAILING � EDGE NAILING PER SCHED. FLOOR SNEATHING AND NAILING � EDGE NAILING PER SCHED. (20) 12d <br /> PER STRUCTURAL NOTES S1.Q 1 PER STRUCTURAL NOTES 51.0 ` PER $TRUCTURAL NOTES S1.0 '� PER STRUGTURAL NOTES S1.0 � <br /> � RIM/BLOCKING TO TOP f RIM/BLOCKIN� TO TOP � RIM/BLOCKING TO TOP � RIM/BLOCKING TO TOP z � ' <br /> �� PLATE PER SNEARWALL � PLATE PER SHEARWA�L �� PLATE PEft SNEARWALL PLATE PER SHEARWALL a� �-., <br /> F� _ , - , SCHEDULE PRQVIDE � SCHEDEILE - PROVIDE „_ __ _ � � _ - � � <br /> � �V� SCHEDULE PROVIDE , SCHEDULE PROVIDE ,� , I <br /> . . . . . . . . . n . n. . �� . . . . .. " a� ii n � . �-..� . .. '�._:a��'rt'"=..�'.,. .�4t'S=��� �..i <br /> ^ 0.148 X3.25 @ 6 O.C. MIN.. 0.148"X3.25" @ 6" O.C. MIN. . . I 0.148"X3.25' @ 6" O.C. MIN.. . . � 0.148 X3.25 � 6 O.G. MIN. ��-� �X._�}_.��.�� \�r����-�-�.- - �, m <br /> ;; ,;, i`; � �j \ � � �� ��� o .� <br /> ,i _ i; � � � \ � cr, O <br /> � ;; �j i ;�',� �I � �� _�_� TOP PLA� , � � � • <br /> � <br /> " � � �=-_�—__..=��__-__��=..�..__ _ ,__ _ ..� _ � <br /> _� _.._� ._.._._ _ � .�. _�. �._ � �� � � <br /> _�__ �__..__�___-______ � . � - - � ----- `° <br /> ,_._�`:_�_.�.____.______� �.__._�__ ...._ ,�.______.___.__,_ . .._. ___.__�._ <br /> ________ __ _------___�. �___--- �._._ _______� ____.____._ ______..________ -_ - �s � _ � <br /> i �' � � � �- � <br /> 1� � �n <br /> EDGE NAILWG PER SCHED. EDGE NAILING PER SCHED. j� —EDGE NAILING PER SCHEQ. � EDGE NAILING PER SCHED. � � <br /> FRAMING PER PLAN ;r � ;t � '� � <br /> �� SEARING AND/OR � BEARING AND/OR {� BEARING AND/OR BEARING AND/OR � � <br /> BLOCKING AT 48" O.C. � SHEARWALL PER PLAN FRAMING PER PLAN � SNEARWALL PER PLAN FRAMING PER PLAN �� SHEARWALL PER PLAN FRAMING PER PLAN � SHEARWALL PER PLAN S7UDS W � ^ <br /> e f <br /> ADQ RIM JOIST/BLKG. I NOTES: � ADD RIM JOIST/BLKG. #� NOTES: ADD RIM JOIST/BI.KG. � NOTES: � � � <br /> AS REQUIRED BY j� 1. SECURE JOIST TO WALL � AS REQUIRED BY �� 1. SECURE JO1ST TO WALL AS REQUIRED BY � 1. SECURE JOIST TO WALL � � � <br /> SHEARWALL SCHEDULE WITH 0.131"X2.5 EA. SIDE, DOUBLE JOIST SHEARWALL SCHEDULE WITN Q.131'X2.5 EA. SIQE, SHEARWALL SCNEDULE WITH 0.131'X2.5' EA. SIDE, � a� �, <br /> 1 1/2" MIN. FROM END. 1 1/2' MIN. FROM END. 1 1/2' MIN. FROM END. NOTE: � � � <br /> 2. SECURE RIM JOIST TO �� ASL�SHOWNNQI ALL�EXTERIOR, � Q co <br /> PARALLEL BLKG. WITH 0.131"X2.5 PARALLEL PERPENDICULAR 2. SECURE RIM JOfST T0 <br /> PERPENDICULAR JOIST WITH 0.131 X2.5 <br /> NAIL TOP AND BOTTOM. NAIL TOP AND BQTTOM. A DMAT ROOFRTY & SHEAR <br /> � o <br /> (� �--� c� <br /> SCALE: 3/4" = 1'-0" SCALE: 3 f 4" = 1'-p" SCALE; 3 f 4" = 1°-0° SCALE: 3�4" = 1'-0" SCALE: 3�4" = 1'-0" : ,��� y <br /> �� TO �RANi �1G 2 NTER OR WA�� TO FRAMI�IG 3 If�TERIOR WA��. TO FRA�I�1G 4 EXTERIOR WA�� TO FRANI �1G 5 TOP P�ATE SP�ICE = � t,: �-- � h <br /> 1 EXTERIOR WA �� ❑ <br /> � ❑ <br /> � : <br /> . � <br /> , � <br /> _ _ � ;� . <br /> � <br /> JOISTS PERPENDICU�AR JOISTS PARALLEL JOISTS PERPENDICULAR JOISTS PARALLEL <br /> � � :; <br /> PLATE NAILING PER <br /> PLATE NAILING PER SHEARWALL SCHED. TYP. V � <br /> 1 �. <br /> SHEARWALL SCHED. TYP. k. r, SHEARWALL SNEATHING & ,� <br /> �: ' NOTE: `R <br /> �f� �.� NAILING PER SCHED. f�� ;� � �� � � � � <br /> � SHEARWALL SNEATHING & j; �� ,� „ SEE D�TAIL 6 THIS SHEET � ��� � <br /> NAILING PER SCHED. �; a; ;�: ; t7 0 <br /> CONTINUE WALL SHEAT I ` FOR BALANCE <br /> �1 �:; TO RIM W/ EDGE NAILWG �t =.� LAP JOIST 4" AND TOP PLATE ti ���'G�� <br /> RfM TO TOP PLATE A35/LTP4 �'_,. . ELSE PROVIDE RIM TO TOP r; ;! JOIST HANGER USE (3) 8d NAILS SPLICE SEE 5 � '"� <br /> PER SHEARWALL SCHED. `E " PLATE A35 LTP4 PER ,�: �� JOISTS AT SOLID BLOCKING THI$ SHT, � � ; a � <br /> i�' {"; � �; E F ' �� <br /> , y; SHEARWALL SCHED. ;;. Y; TO BEAM �` o � o <br /> . z � PANEL BLOCKlNG AT NON BEARING WALLS � <br /> � _: � � ;�' 1 r;i \ AT BEARING WA�LS HEADERS - MAY BE � �� <br /> ¢ � AS REQ. ATTACHED TO KING STUQ ��`�`�� , �� <br /> � �t t�:: <br /> � � HEADERS: W/HUC HANGER OR A34/ `��,� <br /> ; ; <br /> � ;� ,; � PLYWOQD PLYWOOD 1TUDS AT <br /> ` {;� � \ � u # � 3� 2X8 @ 2X6 WALLS A252X4PMIN. <br /> ` � - - . . . <br /> �� <br /> ..._�___.�a..•.e.::....� .. -.. �. . ^ � 44 . . . <br /> �»___��.:,�_..._�:- .t— -'______.___„._S�.T=:��.c_., :.,._=__�__-..'-_"_:___..._.... W t3 `L <br /> _ � _ <br /> r_���______�.m�__. �;, F; f � :f $� �._���k�� -�m, U.N.O. <br /> _._ .___ .�------_ __�. _ C ) <br /> � , �„ , � UNLESS NOTED � <br /> '-; �_ ;; OTHERWISE PER PLAN �" o <br /> 9� ivS <br /> *` � BUNDLED „ � \ z � <br /> �'= JOfSTS (2) 16d @ 12 <br /> � �� <br /> JOIST PER PLAN TYP. `Q� �� JOIST PER PLAN TYP. � �;, JOIST PER PLAN TYP. <br /> „ > t;, ¢ �, � � <br /> t� "�� �.._�:__>� _____._ __ _ __ __.�� �,, - ,�� TYP. � Q � N <br /> r ; �t PROVIDE INTERIOR CROSS rj,; �:=j KING STUD-TYP. "� '-n <br /> ���' �� WALL OR B�AM AT 12' O.C. ��� � ��; FACE NAIL W� � � �� � � <br /> tt ft f C.: <br /> DOUBLE JOIST MIN. s�t �s ELS� BLOCKING AT 6' O.C. �A? �2 JOIST PER JOIST PER (2) 16d � 12" O.C. � � <br /> ,;.; �_. JO1ST PER PLAN TYP. ��� �E PLAN PLAN TYP. � p <br /> !;�3 "; DOUBLE JOIST MIN. ��x ,�; AT BEARING WALLS AT NON-BEARING WALLS w ~� <br /> SHEATHING AND NAILING PER "�� '.' SHEATHING AND NAILING PER {'# �� JOIST HANGER 2X BLOCKING TRIMMER STUDS: (1) TRIMMER STUD <br /> �.�a ; t.;.� :_� <br /> SHEARWALL SCNED. TYP. SHEARWALL SCHED. TYP. 1) C� OPENINGS UP TO 5'-0" WIDE <br /> BEAM PER PLAN BEAM PER PLAN � t� � <br /> 2} � OPENINGS 5-1 & GREATER <br /> NOTE: FIRE AND SOUND NOTE: FIRE AND SOUND UNLESS NOT�D OTHERWISE PER PLAN � <br /> RATWG INFORMATION PER RATING INFORMATION PER A: FLUSH BEAM B: DROPPED BEAM <br /> 0 <br /> SCALE: 3/4° = 1'_0" ARCH. SCALE: 3 j4" = 1'-0'> ARCH. _ SCALE: 3/4" = 1'-0" SCALE: NONE � � � <br /> 6 TYPICA� PARTYWA�� 7 TYPICA� PARTYWA�� AT STEP 8 B�I�T UP BE�i� g0 TYP� CO�1N. TQ WOOD BEAM 10 TYP. HDR. AT STRUCT. WA�� ~ �' <br /> 0 <br /> o a � <br /> _ � <br />� . . . .. . . .. . . .—� . . . . . . . . . __ . . . .. .. .. . . . . . .. . . . . .. . . . . .. . . .. . --. . . . . . . . . . . . J � <br /> UPPER WALL: NOTE: SEE ARCH. FOR STAIR DIMENSIONS � ~ <br /> UNLESS HANGERS/HARDWARE ARE SHOWN WALL PLATE NAfLING PER BEARING/SHEAR WAL� � �= Q <br /> ON PLANS, sEAMS BEARING ON STUD WALLS AND BLOCKING REQUIREMENTS 0.148'X3.25" <br /> SCHFD, FOR UPPER WAI L PER PLAN AND SCHEDULE � 4" O,C. �-��{ � v <br /> SHALL BE ANCHOftED W/(4) 8d TOENAILS STAGGERED �I "' <br /> FLOOR NAILING PER L = HORIZONTAL RUN ' - -� '= w <br /> STRUCTURAL NOTES P.E.N. PER UPPER WALL » ��j i � � <br /> MST37 STRAP 2X12 STRINGERS FOR L<84 <br /> 1.75X14 LVL STRINGERS FOR 84"<�<14 ° �� °- <br /> � <br /> CONT: RIM JOIST — _ - - A35 j��``.= O � � <br /> 2X BLOCKING TYP. 2 <br /> TOP PLATE A TOP PLATES 4����.,, <br /> TOP PLATE BEYOND � <br /> � BEAM BEAM <br /> PER PLAN PER PLAN � T � � � � ' <br /> I i WALL STUD <br /> - - - - _ _ - - - - - - - - - - 1/�'�MIN. <br /> - - - - - - - - - - _ _ - - - - <br /> _ � BLOCK FLOQR �«ANDING � <br /> - DIAPNRAGM EDGES STRINGERS � <br /> w r-- <br /> n_���._�_�_���--��=-�:�,�.---� �-__�___��-=--_�_�_-� <br /> � ' _____ �- -� v.� � <br /> PROVIDE (4) LTP4 BEAM PER PLAN PROVIDE (4) LTP4 r�� � <br /> EACH SIDE OF EACH SIDE OF (2} 8d TOENAILS (2) 8d TOENAILS 2x � ��� 2X RIM JOIST �� I�I) II/I }� • � Q <br /> BEAM BEAM BEAM PER PLAN EACH SIDE EACN SIDE PER PLAN � �� IIII IIII i � � <br /> AN ON} P ANS U.N.O. 2x BLOCKING � ��--LL-���������� `� � <br /> POST PER PL � P.E.N. PER LOWER WALL � <br /> BEAM/HDR � SIM. � � <br /> EXTERIQR INTERIOR WALL AND CEILING � W = WIDTH �/4" VERIFY � <br /> WALL WALL PER ARCH. LOWER WALL: q (3) STRINGERS FOR W<42" � <br /> BEARING/SHEAR WALL (4) STRINGERS FOR 42"<W<48" � <br /> PER PLAN AND SCHEDULE y,(� � <br /> TYP. TQ P P LA TE TYP� TLJ P P�A TE SCALE: 3�4" = 1'-0" TRUSSES PERPENDICULAR ELEVATION AT WALL SECTION A-A AT WALL �J�� <br /> SCALE: 3/4" = 1'-0" � Q <br /> 11 SP�ICE AT F�USH BEA�1 12 SP�ICE AT DROPPED BEANI 13 BEAN1 TOE�1A � NG 14 CANT �E�ER F�OOR JOIST 15 TYP. STA R FRAN11�1G AT WA�� • � � <br /> 0 � <br /> 0 _ <br /> UPPER WAIL• UPPER WALL• � <br /> WA�L PLATE NAILING PER BEARING/SNEAR WALL WALL PLATE NAILING PER BEARING jSHEAR WALL � Q <br /> SCHED. FOR UPPER WALL PER PLAN AND SCHEDULE SCHED. FOR UPPER WALL PER PLAN AND SCNEDULE t , � <br /> NOTE: NO WALL ABOVE AT SIM. SEE ARCHITECTURAL �1 <br /> _ _ 1 FOR ALL FLASHWG DETAILS r T , � <br /> FLOOR NAILING PER P.E.N. PER UPPER WALL CONTINUOUS STRAP ; � <br /> FLOOR NAILING PER P.E.N. PER UPPER WALL ;��' �� POST - WRAP PER ARCH. �"""� � � <br /> STRUCTURAL NOTES I DRAG STRUT PER PLAN STRUCTURAL NOTES �� ° <br /> 2X4 RAFTER EA. JOIST P.E.N. PER LOWER WALL ��I-'' �I � <br /> BEAM PER PLAN 1 3/4" PSL BLOCKING DIAPHRAGM NAILING 2X BLOCKI�IG DIAPHRAGM NAILING _ 6X6 POST WITH ABU66 � � <br /> � � —ii� �� BEAM - ALIGN WITH � <br /> ` BLOCKING � `- . . ;; . • „ . CENTER OF WOOD POST � � � <br /> � . '� u� u <br /> ��. • DI PHRAGMLEDGES — — ;�.f � O <br /> ( � , � _ �.,, bJJ <br /> � �'� � <br /> � -- ; <br /> _ _____�_.__.._____.______ _,._._____�_..______----.._ ;, <br /> --�.__�___.�_�.�_�.�_.._R.._�._�_._____....__�..__w____.__.__.___�_ <br /> � _ -- --- --._ ._ :_ �. . <br /> I -� _�___. , ^ <br /> _ _ __ _�_ __ _ ,,, i ,a <br /> �._-� d�-�=.��..��.__�.-��-_ __.-�_-�-�. -.� <br /> � �;, �; <br /> � <br /> _ w�..��-__�:_ � <br /> ,, _._.____� .,,___._�_T <br /> � i BEAM/HDR � SIM. + � l��a.- •,� � � <br /> SIMPSON A35 B�KG. : /\ , JOIST � /\ � r� , \':� TRIM RE:ARCH. � � <br /> JOIST JOIST PER � TO TOP PLATE BEYOND � P.E.N. PER LOWER WALL �` � ��� I{' � � <br /> PER PLAN PLAN - TYP. �� SPACING PER � � <br /> PER PLAN i <br /> BEAM TO POST W/ EPC ' � � � <br /> SHEARWALL SCHEDULE � PANEL SHEATING�NAILING � » �i� I�i POST CAP <br /> � � (2) 0.228 DIA. Ledger�Qk j;) ��; � E--I �; <br /> � SQFFIT RE: ARCH. TO MATCH LOWER WALL ' ^ ,; <br /> � SHEARWALL BEYOND NOTES: — � PENETRATION/TO RIM AT �� �, � <br /> E�I � I.� � <br /> HOLDOWN STRAP PER SHEAR WALL SCHED. CANT'L. JQIST LOWER WA�L: 24 Q.G. STAGGERED fi� ��! �� 4� <br /> CEILING PLAN � � SEE ALSO DETAIL 7 SHEET A9 WALL AND CEILING � i ��I I`;�T � <br /> TYP. BEARING SHEAR WALL � �T� w <br /> PER ARCH. PER 13/S1.3 PER ARCH. PER PLAN AND SCHEDULE E���{ <br /> 2X LEDGER <br /> NOTE: <br /> LedgerLok Fasteners shall <br /> be per ICC ESR-1078 <br /> SCALE: 3�4" = 1'-0" SCALE: 3/4" = 1'-0" SCALE: 3/4" = 1'-0'� JOIST PERPENDICULAR SCALE: 3'f4" = 1'-0" JOIST PERPENDICULAR SCALE: 3/4° = 1'-0" <br /> � 17 TYPIC�� DRAG STRUT 18 �OW ROOF 1 g �QAD TRANSFER DETAI� 20 TYP. SECTI0�1 AT DECK FRMG. � <br /> 16 SNEAR WAL TQ BEAM C� 0 <br /> � 0 <br /> 0 � <br />