Laserfiche WebLink
3�2/3�03 FLOOR SURFACES � CW4NGES IN LEVEL 404 DOORS continued 502/5Q3 PARKING IWD PA� LQ�ING ZONES c:onti�� 604 WATER CLt�SEi'S �C TOILET (�IPAaTk1ENi'S continu�d 609 GRAB BAR.S 703 SIGNA�E continued <br /> GALVANIZm MOUNi1NG 90LTS OVERHEAD SIGNS <br /> ANSI/ICC A117.1 303 - CHANGES IN LEVEL (REFERENCE DEfAIL) ANSI/ICC A117.1 404.2.6 - DOOR HARDWARE ANSI/ICC A117.1 604J - DISPENSERS (REFERENCE DETAIL) ANSI/ICC A117.1 609.3.2 - SIZE AND SPACING <br /> � A. CHARACTERS AND NUMBERS ON OVERHEAD SIGNS SHALL BE SIZED ACCORDING TO THE <br /> A. Changes in level up to 1/4" may be vertical and without edge treatment A. Handles, pulls, latches, locks, and other operating devices shall have a shape that is - � A. Toilet paper dispensers shaU comply with Section 309.4 and 609.3. Where the A. Diameter or width of gripping surface shall be 1-1/4" to 7', or the shape shall VIEWING DISTANCE FROM WHICH THEY ARE TO BE READ. <br /> B. Changes in level between 1/4 and 1/2" shall be beveled with a slope no greater easy to grasp with one hand and does not require tight grasping, tight pinching, or dispenser is located above the grab bar, the outlet of the dispenser shall be located provide an equivalent gripping surface. 1. FOR SIGNS HIGHER THAN 70" A.F.F., CHARACTER SIZE SHALL BE 7' MINIMUM PLUS <br /> than 1:2. c twisting of the wrist to operate. � '�n 24 min-36" max from the rear wall. Where the dispenser is located below the grab 1. The space between grab bars and adjacent walls shall be 1-1/2" �" PER FOOT OF VIEWING DISTANCE ABOVE 15 FEET. <br /> �., 1. Lever-operated mechanisms, push-type mechanisms, and U-shaped handles are � bar, the outlet of the dispenser shall be located 24 min-42" max from the rear ,. <br /> '� � acce table desi ns. �A� i t. THE MINIMUM HEIGHT IS MEASURED USING AN UPPER CASE LETTER "I". <br /> � i 2 P 9 a$qe�p wall. The outlet of the dispenser shall be 18"-48" maximum A.F.F. ANSI/ICC A117.1 609.8 - STRUCTURAL STRENGTH 2. LOWER CASE LETTERS ARE PERMITTED. <br /> a 2. When sliding doors are fully open, operating hardwore shall be exposed and usable PARKING 1. Dispensers thot control delivery or do not permit continuous paper flow sholl not A. Grab bars and mounting devices shall meet the following requirements: <br /> `� � �� from both sides. REq iu� � �, <br /> � be used. 609.8 Allowable stresses shall not be exceeded for materials used where a vertical <br /> � 3. Hardware required for accessible door passage shall be mounted between 34" and � V�N or horizontal force of 250 Ibs. is applied at any point on the grab bar, fastener ANSI/ICC A117.1 703.3-703.5 - RAISED CHARACTERS, BRAILLE, & PICTOGRAMS <br /> 48" above finished floor. z o ACCESS�BLE ANSI/ICC A117.1 604.9 - WHEELCHAIR ACCESSIBLE COMPARTMENTS mounting device, or supporting structure. A. Raised characters shall comply with section 703.3 and shall be duplicated in braille <br /> De ail � o z A. V�tteelchair a�cessible compartments shall comply with Section 604.9. Toilet 1. Sltear stress induced by application of 250 Ib. shall be less than allowable shear complying with section 703.4. <br /> ANSI/ICC At 17.1 404.2.7.1 - DOOR CLOSERS �c� PRE-MlWUF. SIGN compartments shall comply with Section 604.9.2.1 or 604.9.2.2 as applicable. stress for material used. If connection between grab bar and mounting bracket B. Letter and numerals shall be raised 1/32", upper case, sans serif and shall be <br /> ANSI/ICC A117.1 302.2 - CARPET A. Door closers shall be adjusted so that from an open position of 90 degrees, the � m�' 4 DUl STEEL POSf W/ CAP is considered to be fully restrained, then direct and torsional shear stresses shall accompanied by grade 2 Braille. <br /> A. Carpet provided on a floor surFace shall be securely attached; have a firm pad or time required to move the door to an open position of 12 degrees shall be 5 � o FlNISH GRADE be totaled for the combined shear stress, which shall not exceed the allowable 1. Raised character height: �' minimum to 3" plus � per foot of viewing distance <br /> backing, or no pad; and have a level loop, textured loop, level cut pile, or level seconds minimum. '- . shear stress. above 21 feet. <br /> cut/uncut pile texture. Maximum pile thickness shall be 1/2". Exposed edges of �' i s�r Posr iN coHe. 36" MAX 36" MAX 2. Shear force induced in a fastener or mounting device from application of 250 Ib. 2. Braille shall be contracted (grade 2); shall be located below title corresponding <br /> carpet shall be fastened to floor surfaces and have trim alang the exposed edges. ANSI/ICC A117.1 404.2.7.2 - SPRING HINGES � `7 �•;., shall be less than allowable lateral load of either the fastener or mounting device text. <br /> NOTE: INSTALL StGN AT ALL ACCESSIBLE PARKING 24° MIN or the su ortin structure whichever is the smaller allowable load. 3. Picto rams shall be accom anied b the e uivalent verbal descri tion laced <br /> A. Door spring hinges shall be adjusted so that from the open position of 70 degrees, � ,i i z PP 9 � 9 P Y 9 P P <br /> , i I,', STALLS• SPACES DESIGNATED FOR VAN PARKING SHALL � 3. Tensile force induced in a fastener b a direct tension force of 250 Ib. lus the directl below the icto ram. <br /> ANSI/ICC A117.1 302.3 - GRATINGS the door shall move to the closed position in 1.5 seconds minimum. Y P y p 9 � � C � I � £ C '� 5 <br /> •.i i �vE aoomot�sicN"VAN ACCESSIBL� MOUNTED a maximum moment from the a lication of 250 Ib. shall be less than the 1. The border dimension of the icto ram shall be 6" min. in hei ht. <br /> A. If gratings are located in walking surfaces or along accessible routes, then they Shall 1-I ; BELOW. MOUM ON WALL OF BLDG WHEN POSSIBLE. c� z PP P 9 9 <br /> have spaces no greater than 1/2" wide in one direction. ANSI/ICC A117.1 404.2.8 and IBC with WA STATE AMENDMENTS - DOOR OPENING FORCE � � ,� � allowable withdrawal load between the fastener and the supporting structure. <br /> B. If ratin s have elon ated o enin s then the shall be laced so that the lon A. The maximum force for ushin or ullin o en doors shall be as follows: _�, � � 609.6 Grab bars shall not rotate within their fittings. ANSI ICC A117.1 703.3.12 - FINISH AND CONTRAST <br /> 9 9 9 P 9 � y P 9 p 9 p 9 P Deail � 2505 Third Avenue <br /> dimension is perpendicular to the dominant direction of travel. t. Fire doors shall have the minimum opening force allowable by the appropriate �'j �� '- � A. Characters and their background shall have a nonglare finish. Characters shall <br /> administrative authority. z � ? � ANSI/ICC A117.1 609.5 - ELIMINATING HAZARDS contrast with their background, with either light characters on a dark background, or Suite 324 <br /> � C�� �� �� 1. Other doors Handrail to extend Handrail to extend � � A. Grab bars and adjacent wall surfaces shall be free of sharp or abrasive surfaces. dork charocters on a light background. Seattle, WA 98'12'I <br /> a. Exterior hinged, sliding or folding door: 10.0 Ib. max. horizontally at top horizontally at top and � Edges shall be rounded. <br /> Bottom rail to rovide <br /> b. Interior hinged doors: 5.0 Ib. max. P extension bottom extension ANSI/ICC A117.1 703.3.10 & 703.3.11 - MOUNTING LOCATION AND HEIGHT (REFERENCE DETAIL) <br /> ANSI/ICC At 17.1 305.2 - SIZE AND APPROACH c. Interior slidin or foldin doors: 5.0 Ib. max. edge protection � 54" MIN A. Characters and their back round shall have a non lare finish. Characters shall <br /> A. Minimum clear floor s ace for a wheelchair and occu ant shall be 30" wide x 48" 9 9 / � � 9 9 206.720.700'I phone <br /> P P These forces do not apply to the force required to retract latch bolts or disengage If vertical rise is greater 4 MIN 4' MIN contrast with their background, with either light characters on a dark background, or 206.720.2949 fax <br /> lon . Clear floor s ace shall be centered on the element it serves. y P Handrail to extend with 42„ RX 42" AX 3g"_4�" dark characters on a light background. <br /> 9 P other devices that ma hold the door in a closed osition. slope at bottom extension than 6" then bottom rail <br /> Exception: Interior or exterior automatic doors complying with Section 404.3 of ICC g� to provide edge protection B. Where a tactile sign is mounted next to a door, it shall be placed to the latch side <br /> At 17.1. "' <br /> i Protruding D��e�ser Protruding Dispenser Recessed Dispenser 12" MAX 42" MIN � 36" MIN. of the door wherever possible. Where a tactile sign is placed adjacent a double door, WWW_craftarchitects.com <br /> �� PROIRUDING OB�lECTS (REFERENCE DETAILS) the sign shall be to the right hand door. If there is no wall space to the right, <br /> 4Q6 CURB I�PS (1) TREAD DEPTH 1'- R� � Below Grab_Bar Above Grab Bar <br /> M � 12" 24" signs shall be placed on the nearest adjacent wall. Exception: Door mounted signs <br /> ANSI/ICC A117.1 307 - GENERAL ANSI/ICC A117.1 406 - SLOPE (REFERENCE DETAIL) �-� � - � o� wide aide shall be permitted on the push side on the doors with closers and without hold open <br /> A. Objects projecting from walls (for example, telephones) with their leading edges A. Slopes of curb ramps shall comply with 406 � �� � devices. <br /> between 27'-80" above the finished floor shall protrude no more than 4 into walks, B. Maximum slopes of adjoining gutters, road surface immediately adjacent to the curb � _ ��� '� x a- � C. Raised characters shall be 48" minimum above the floor, measured to the baseline <br /> halls, corridors, passageways, or aisles. Freestonding objects mounted on posts or ramp, or accessible route shall not exceed 1:20. "i' a' o, "i' of the lowest raised character and 60" maximum above the floor, measured to the <br /> €� � M i� baseline of the highest raised character. <br /> pylons may overhang 12" maximum from 27"-80" above the ground or finished •� ,., t � ,., <br /> floor. Protrudin ob'ects shall not reduce the clear width of an accessible route or ANSI ICC A117.1 406.4 - WIDTH REFERENCE DETAIL ANSI/ICC At 17.1 605 - URINALS � � D. Mounting location for such signage shall be so that a person may approach within <br /> 9 J � � ) Handrail at Stair Handrail at RamR A. Accessible urinals shall comply with Section 605. 3" of si na e without encounterin rotrudin ob'ects or standin within the swin of � <br /> maneuvering space. A. The minimum width of a curb ramp shall be 36", exclusive of flared sides. 1 1/2' 1 1/4" to 2" � � 9 9 9 P 9 � 9 9 � <br /> a door. <br /> ANSI/ICC A117.1 406.3 - SIDES OF CURB RAMPS (REFERENCE DETAIL) ANSI/ICC A117.1 605.2 - HEIGHT & DEPTH (REFERENCE DETAIL) Side Wall Grab Bar for Water Closet Rear Wall Grob Bor for Water Closet <br /> I A. If a curb ramp is located where pedestrians must walk across the ramp or where it A. Urinals shall be stall-type or wall hung with a tapered, elongated rim ot 17' IBC with WA STATE AMENDMENTS 1101.2.6 - INTERNATIONAL SYMBOL OF ACCESSIBIUTY <br /> maximum above the finished floor. The rim shall extend a minimum of 1�' from A. Where the International Symbol of Accessibility is required, it shall be proportioned <br /> 4" MAX. EAR WIDT ANY AMOUNT is not protected by handrails or guardrails, it shall have flared sides; the maximum � <br /> LOBBY= the walL � -� complying with ANSI/ICC A117.1 Figure 703.6.3.1. All interior and exterior signs ' . <br /> slope of the flare shall be 1:10 � <br /> Han�Section depicting the International Symbol of Accessibility shall be white on a blue <br /> r AN51/ICC A117.1- 605.3 - CLEAR FLOOR SPACE (REFERENCE DEfAIL) background. � � � <br /> � .--- ' Adjoining Slope Shall A. A clear floor space 30" wide by 48" deep minimum sholl be provided in front of t5��� <br /> .�- Not Exceed 1:20 ANSI/ICC A117.1 602.1 - GENERAL utinal to allow forward approach. 0 <br /> I � HAND SHOWER/ X ^, <br /> z If x Is less than 48" A. Accessible drinking fountains shall comply with Sections 602 and 307. 1. This space shall adjoin or overlap an accessible route. 24" SLIDE BAR � w `� <br /> � � Then The Slope Of The Flare Flared side 2, Urinal shields that do not extend beyond the front edge of the urinal rim may be <br /> � �a I �q Sides Shall Not Exceed 1:12 ANSI/ICC A117.1 602.2 - CLEAR fL00R SPACE provided with 29" clearance between them. ^ ^ � I � � � <br /> A. A clear floor space complying w/ Section 305, positioned for a forward approach 3. Urinals installed in alcoves deeper than 24" require a maneuvering area of at T VI � \� Z L/! <br /> � i � 3Fj" 1"(��n to the drinking fountain, shall be provided. Knee & toe space complying with least 36" minimum wide, centered on fixture. °� � � <br /> � Section 306 shall be provided. The clear floor space shall be centered on the � � � .. .� .� � W Q <br /> N � drinking fountain. ANSI/ICC A117.1 605.4 - FLUSH CONTROLS (REFERENCE DETAIL) T � �� � �� � � � <br /> EXCEPTIONS: <br /> Detail Detail Controls shall comply with ANSI/ICC At 17.1 309 OPERABLE PARTS z o <br /> 1. Drinking fountains for standing persons. Letter & numbers on si ns shall have a width <br /> Ramp (1:12 Max. Slope) � � i F g <br /> Shall Have Detectable Warnin s 2. Drinking fountains primarily for children's use. �, 4'Mp,)( �r �' � •- <br /> � g � i to height ratio of between 3:5 & 1:1 and � � <br /> � � � � �� � �� P� � and contrasting color. 3. In existing building, existing drinking fountains providing a parallel approach � � a stroke - width to height ratio between � <br /> � complying w/ Section 305, centered on the drinking fountain shall be permitted. a 48" MIN. "' 1:5 & 1:10. Letters and numbers shall be raised � <br /> 1:10 Max. slope 4. Where specifically permitted by the administrative authority, a parallel approach ; � 1/37', upper case, sans serif or simple serif � � <br /> ANSI/ICC A117.1 308 - HEIGHT (REFERENCE DETAIL) � e and shall be accom anied with <br /> Standard Curb Ramo shall be permitted that replace existing parallel approach drinking fountains. �------- � typ p <br /> A. Unobstructed front approach - 48" max. to 15" min. A.F.F. Controls located in an 36" Min. �N i <br /> alcove >24° deep must have 3C>" clear floor width. Adjoining Slope Shall '� 0 5 � CONTROL AREA grade 2 Braille, raised characters shall be at - T � <br /> ANSI/ICC A117.1 602.3 - OPERABLE PARTS � � o�,.� � � least 5/8' 3' high plus 1/8" per foot of <br /> B. Unobstructed side approach - 48` max. to 15" min. A.F.F. Controls located in an Not Exceed 1:20 A. 0 erable arts shall com I with Section 309. viewin distance above 21 feet. � O w <br /> alcove >15" deep must have 60" clear floor width. p p Py `� =� �______ _ Side Wall Grab Bar for Shower Rear Wall Grab Bar for Shower 9 M � <br /> C. Electrical & communication s stem rece tacles shall be mounted no less than 15" � 'E� � J <br /> Y P ANSI/ICC A117.1 602.4 - SPOUT OUTLET HEIGHT = „ � Detail � <br /> above the floor. Location of Typical p. Wheelchair accessible spout outlets shall be 36 inches max. aff. Standing person \ �� 14 MIN � O <br /> �Parking Access Ais�e sp�ut outlets shall be 38 inches min. & 43 inches max. aff. pe}g ��G � 702 � <br /> ANSI/ICC A117.1 309 - OPERABLE PARTS � /� 7� <br /> Operable parts shall be operable with one hand and shall not require tight grasping, ANSI/ICC A117.1 602.5 - SPOUT LOCATION ANSI/ICC At17.1 702.1 - GENERAL International Symbol � <br /> pinching, or twisting of the wrist. The force required to activate operable parts shall be � Ramps (1:12 Max. Slope) A. Spout shall be located 15 inches min. from the vertical support and 5 inches max. A. When required, visual alarms shall be provided in each of the following areas, as a of Accessibility <br /> 5.OIbs maximum. 1:12 Max. slope Shall Have Detectable Warnings from the front edge of the drinking fountain, including bumpers. �6 ����� minimum: rest rooms and an other eneral usa e areas e meetin rooms <br /> and contrasting color. Y 9 9 � •9•� 9 �. � � <br /> Curb Ramp Parallel to Curb Note : If Slope is 1:20 or less ANSI/ICC A117.1 606.3 & 606.2 - HEIGHT & CLEARANCES (REFERENCE DETAILS) hallways, lobbies, and any other area for common use. O <br /> �� no contrasting color or texture ANSI/ICC A117.1 602.6 - WATER FLOW <br /> ,l is required A. Spout shall provide a flow of water 4 inches min. in height. The angle of the water A. Lavatories shall be mounted with the rim or counter surface no higher than 34" Accessible audible and visible alarms and notification appliances shall be installed in <br /> ��� above the finished floor. » <br /> ,��,� 0 stream from spauts within 3 inches of the front of the drinking fountain shall be 30 accordance with NFPA 72. Light switch 8 MAX <br /> ��� � degrees max. and from spouts between 3 inches & 5 inches from the front of the 1. Lavatories shall extend 17' minimum from the wall. Thermostats, Etc. <br /> ` � ANSI/ICC A117.1 406.10 - DIAGONAL CURB RAMPS drinking fountain shall be 15 degrees max., measured horizontally relative to the 2. Clearance of 27' minimum shall be provided fram the finished floor to bottom of NFPA 72 - AUDIBLE ALARMS w <br /> � o �,:�.� � Y A. If diagonal curb ramps have returned curbs or other well-defined edges, such edges front face of the drinking fountain. apron. A. If provided, audible alarms shall produce a sound that exceeds the prevailing � w <br /> � o \�;�� � �� � oo shall be parallel to the direction of pedestrian flow. The bottom of diagonal curb � 3. Knee clearance of 27' high minimum shall extend 8" minimum under the edge of equivalent sound level in the room or space by at least 15 dba or exceeds any c``'i� � 0 0 <br /> -«, ���` i = ramps shall have 4 8" minimum clear space outside active traffic lanes of the 5 MAX 15 MIN t he lava tory, 3 0" wi de minimum, an d 1 9" deep minimum. maximum soun d leve l wi t h a dura tion o f 6 0 secon ds by 5 d ba, w hic hever is lou der. m � � <br /> �n '� � o roadway. If diagonal curb ramps are provided at marked crossings, the 4 8" clear 4. Toe c learance o f 9" minimum s ha l l be provi de d for t he fu l l dep t h o f t he B. Soun d leve ls for a larm signa ls s ha l l no t excee d 1 2 0 d ba. � c..> � COWSULTANT <br /> i space shall be within the markings. If diagonal curb ramps have flared sides, they �----- --- � �a�a{ory, m � � z <br /> � N �n shall also have at least a 24" long segment of straight curb located on each side j =� � NFPA 72 - VISUAL ALARMS a = 5�, � 0 0 <br /> � � of the curb ramp and within the marked crossing. I I a� ANSI/ICC A117.1 606 - DEPTH A. Ysual alarm signal appliances shall be integrated into the building or facility alarm � c� � ;r, -,,- �--------�-w----�� <br /> � � -� A. E a c h s i n k s h a l l be a maxi mu m o f 6-1 2" dee . system. If single station audible alarms are provided then single station visual alarm � _ '- "}�' �, � .�^; � <br /> � \ �------ � I P . . � ?cC�,.�, EF�t�D <br /> N si nals shall be rovided. `` �,,, , r <br /> ANSI/ICC A117.1 406.11 - ISLANDS ` 9 P � � � � �... ;�;=1(,;r-11 i �C�r <br /> FULL LENGTH MOP BROOM STAINLESS SOLID HAT COAT o Ysual Alarm appliances shall have the following features: � <br /> � � A. Any raised islands in crossings shall be cut through level with the street or curb � � �_ <br /> M I R R O R H O L D E R S T E E L P I A S T I C HOOK \ •� 1. T h e l a m p s h a l l b e a x e n o n s t r o b e t y p e o r e q u i v a l e n t. C o n v e n i e n c e O u t l e t s <br /> ramps at both sides and a level area at least 48" long and 36" minimum wide / o -� <br /> SHELF BENCH between the curb ramps in the part of the island intersected by the crossings. Forward roach � t 2. The color shall be clear or nominal white (i.e. unfiltered or clear filtered white Detail Data, Tel., Etc. j �� � � <br /> � �E � light). / <br /> �3 TAILET �S E ,� 17' MIN � 3. The maximum ulse duration shall be two-tenths of one second with a maximum h� 7h; tYPJ P�i CRF��� <br /> 410 PLA1FORkl LIFI'S � � duty cycle of 40�. (The pulse duration is defined as the time interval between 804 KQCHENS ANU KRCNENEII'ES �TF�� �����'�x���� <br /> ANSI/ICC A117.1 603.2.2 - DOORS � � ? � initial and final oints of 109� of max si nal ""� �,a • �'� ��^ <br /> 403 AI:CFSSIBI.F ROLITE - WN.KING SURFACES ANSI/ICC A117.1 410.1 - GENERAL A. Doors shall not swing into the clear floor space or clearance for any fixture. o o � clear P 9 ) ANSI/ICC A117.1 804.5.6 - REFRIGERATOR/FREEZER `� � <br /> A. Plotform lifts shall comply with Section 410 and ASME A18.1 listed in Section Z Z � � -�' Z � floor �° 4. The intensity shall be a minimum of 75 candela. Combination refrigerators and freezers shall have at least 50% of the freezer <br /> IBC 1104 - LOCATION 105.2.6. Platform lifts shall not be attendant o erated and shall rovide unassisted - � `M space 5. The flash rate shall be a minimum of 1 Hz and a maximum of 3 Hz compartment shelves, including the bottom of the freezer 54 inches (1370mm) <br /> P P ANSI/ICC A117.1 603.2 - CLEARANCES - _ � � L- - - 6. The a liance shall be laced 80" above the hi hest floor level within the s ace <br /> A. At least one accessible route within the site shall be provided from public entry and exit from the lift. A. The accessible fixtures and controls required shall be on an accessible route. An o, N N M =d. � PP p 9 P maximum above the floor when the shelves are installed at the maximum heights <br /> transportation stops, accessible parking and accessible passenger loading zones, and ' unobstructed turning space complying with 304 shall be provided within an accessible 1 g M� or 6" below the ceiling, whichever is lower. possible in the compartment. A clear floor space, positioned for a parallel approach <br /> public streets or sidewalks to the accessible building entrance served. ANSI/ICC A117.1 410.2 - LIFT ENTRY toilet room. The clear floor space at fixtures and controls, the accessible route, and a. In large rooms and spaces exceeding 100' across, without obstructions 6' to the space dedicated to a refrigerator/freezer, shall be provided. The centerline of the <br /> 9 PY P the turning space may overlap, however; the only turning space provided shall not be g� MIN MAX 48'� MIN above the finished floor, such as auditoriums, devices may be place around the clear floor s ace shall be offset 24 inches 610 mm maximum from the centerline of <br /> A. Lifts with doors or ates shall com I with Section 410.2.1. Lifts with ram s shall P � ) <br /> ANSI/ICC A117.1 403.5 - CLEAR WIDTH comply with Section 410.2.2. located within a stall. perimeter, spaced a maximum 100' apart, in lieu of suspending appliances from the dedicated space. <br /> A. The minimum clear width shall be 32" at a oint for a max. len th of 24" and 36" 17' MIN ; the ceiling. <br /> P 9 ; 7. In general, no place in any room or space shall be more than 50' from the <br /> continuously, per Table below. ANSI/ICC At 17.1 410.2.1 - DOORS AND GATES ANSI/ICC At 17.1 603.3 & 606 - LAVATORIES AND MIRRORS signal (measured in a horizontal plane). <br /> A. Doors and gates shall be low energy power operated doors or gates complying with A. If lavatories and mirrors are provided, then at least one of each shall comply 902 D� SURFACES dt �ORK SURFI4CES <br /> Section 404.3. Doors shall remain open for 20 seconds minimum. End door clear with 603.3 & 606. Accessible lavatories and mirrors shall not be located within toilet ' 8. No place in common corridors or hallways shall be more than 50' from the <br /> signal. ANSI ICC A117.1 902.2 - CLEAR FLOOR SPACE <br /> opening width shall be 32 inches minimum. Side door clear opening width shall be stalls unless other Qccessible lavatories and mirrors are provided in the toilet room. ' / <br /> Mlro��u►� 42 inches minimum. \ A. A clear floor space complying with Section 305, positioned for a forward approach, <br /> SEGMEMT LENGTH SEGMENT WIDTH xce tion� ANSI/ICC At 17.1 603.3 - MIRRORS (REFERENCE DETAIL) \� f,,., shall be provided. Knee and toe clearance complying with Section 306 shall be <br /> iess �,an or 32' Lifts serving two landings maximum and having doors or gates on opposite sides A. Mirrors shall be mounted with the bottom edge of the reflecting surface 40" � � WHERE APPLICABLE provided. <br /> e ual to: 24' shall be permitted to have self closing manual doors or gates. maximum A.F.F. Mirrors not located above lavatoreis, sinks or counters shall be ,� `� A. Signs which designate permanent rooms and spaces shall comply with the <br /> qreater than: 24 3s' mounted with the bottom edge of the reflecting surface 35" maximum above the '� � requirements listed below for: ANSI/ICC A117.1 902.4- HEIGHT <br /> ANSI/ICC A117.1 410.2.2 - RAMPS floor. � Ao � � �o � i z 1. Raised and Braille Characters, and Pictograms A. The tops of accessible tables and counters shall be 28" minimum, and 34 Submittals/Revisions: <br /> A. End ramps shall be 32 inches minimum in width. Side ramps shall be 42 inches "� „� 2. Finish and Contrast maximum, above the finished floor. <br /> IBC with 1NA STATE AMENOMENTS 1101.2.1 - CLEAR WIDTH minimum in width. �Q} ��R �,�$ � j(n�„ET (�IP/IR'l�(EJr(r$ `� �;, � `'� �:, � Exception: Employee name signs are not required to comply. <br /> A. Clear width of an accessible route shall comply with Table above. For exterior routes N CV 11/03/16 FOR PRICING & PERMIT <br /> of travel, the minimum clear width shall be 44. ANSI/ICC A117.1 410.3 - FLOOR SURFACES ANSI/ICC A117.1 604.3 - CLEARANCES � WHERE APPLICABLE 903 BENCHES <br /> A. Floor surfaces of platform lifts shall comply with Section 302 A. Clear floor space for water closets not in stalls shall be provided as follows: A. Signs which provide direction to, or information about, functional spaces of the <br /> ANSI/ICC A117.1 403.5.2 - PASSING SPACE _ Clearance around a water closet shall be 60" minimum in width, measured WALL MOUNTED LAVATORY MOUNTED IN building shall comply with the requirements listed below for: ANSI/ICC A117.1 903.2 - CLEAR FLOOR SPACE <br /> A. If an accessible route is less than 60" in width, then passing spaces of at least ANSI/ICC A117.1 410.4 PLATFORM TO RUNWAY CLEARANCE perpendicular from the sidewall. Clearance around the water closet shall be 56" LAVATORY COUNTER 1. Character Praportion A. a clear floor space complying with section 305, positioned for parallel approach to <br /> 60°x60" shall be provided at 200' max. spacing. A. The clearance between the platform sill and the edge of any runway landing shall be minimum in depth, measured perpendicular from the rear wall. (Reference Detail) 2. Character Height the bench seat shall be provided. <br /> 1 1/4 inch maximum B. No door swin s are allowed in clear floor area. 3. Fnish and Contrast <br /> B. The minimum clear width for two wheelchairs to pass is 60" 9 ANSI ICC A117.1 606.6 - EXPOSED PIPES AND SURFACES <br /> � Exception: Building directories, menus, and all other signs which are ANSI/ICC A117.1 903.3- SIZE <br /> ANSI/ICC A117.1 307.2 ANSI ICC A117.1 410.5 - CLEAR FLOOR SPACE 56" MIN. WALL MOUNTED W.C. A. Hot / cold water and drain pipes under lavatories shall be insulated or otherwise tem ora are not re uired to com I . <br /> / ( ) P rY 9 PY A. Benches shall have seats 42" minimum in length and 20" minimum and 24" <br /> 18C 1009.2 and 1010.5.2 A. Clear floor space of platform lifts shall comply with Section 305. 59" MIN. (FLOOR MOUNTED W.C.) configured to protect against contact. maximum in depth. <br /> B. There shall be no sharp or abrasive surfaces under lavataries. WHERE APPLICABLE (REFERENCE DEfAIL) <br /> A. Accessible routes shall have 80" min. clear head room. ANSI/ICC A117.1 410.6 - OPERABLE PARTS 42" K�IN. A. Element and spaces of accessible facilities which shall be identified by the ANSI/ICC A117.1 903.4 - BACK SUPPORT <br /> A. Controls for latform lifts shall com I with Section 309. �� �� ANSI ICC A117.1 606.4 - FAUCEfS Intemational S mbol of Accessibilit are: <br /> ANSI ICC A117.1 403.3 - SLOPE P Py � Y Y A. The bench shall provide for back support or shall be fixed to a wall. Back support <br /> � A. Controls shall be operable with one hand and shall not require tight grasping, 1. Parking spaces designated as reserved for persons with disabilities. shall be 42" minimum in length and shall extend from a point 2" maximum above the <br /> A. Running slope shall not exceed 1:20. pinching, or twisting of the wrist. 2. Accessible passenger loading zones. <br /> B. Cross slope shall not exceed 1:48 seat surface to a point 18" above the seat surface. <br /> �/503 PARI9NG AND PASSFJdGER LO�ADING ZOdES � B. The force required to activate controls shall be no greater than 5 Ib. 3. Accessible entrances when not all are accessible (inaccessible entrances shall have <br /> i � N 6"MAX. C. Lever-operated, push-type, and electronically controlled mechanisms are examples of directional signage to indicate route to nearest accessible entrance). <br /> ANSI/ICC A117.1 502 - PARKING SPACES � � __ � acceptable designs. 4. Accessible toilet and bathing facilities when not all are accessible. <br /> � A. Accessible car parking spaces shall be 96" minimum in width. Van parking spaces I I , � D. If self-closing valves are used the faucet shall remain open for 10 seconds <br /> shall be 132" minimum in width. � N minimum. ANSI/ICC A117.1 703.2.4 - CHARACTER HEIGHT (REFERENCE DETAIL) � ���'E <br /> ANSI/ICC A117.1 404.2.1 - DOUBLE - LEAF DOORWAYS EXCEPTION: Van parking spaces shall be permitted to be 96" minimum in width � � D � � � Z Height: The uppecase letter "I' shall be used to determine the allowable height of all ANSI/ICC A117.1 905.2 - CLEAR FLOOR SPACE <br /> A. Doorwa s with two inde endentl o erated leaves shall have at least one active leaf where the ad'acent access aisle is 96" minimum in width. � i � ANSI/ICC A117.1 603.6 - OPERABLE PARTS A clear floor space complying with Section 305 shall be provided. <br /> Y P Y P 1 � i characters of a font and shall be a minimum of �' and 2" maximum. <br /> that meets the requirements in 404.2.2 and 404.2.3 B. Parkin access aisles shall be 60' wide. Van accessible access aisles shall be 96" I a i � A. Operable parts on towel dispensers and hand dryers shall comply W�tn rabie beioW. Sheet Title: <br /> 9 � L _ _ _ _ ACCESSIBILITY GUIDELINES <br /> wide. � � ? EXCEPTION: Where separate tactile and visual characters with the same information are ANSI/ICC A117.1 905.3 - HEIGHT <br /> ANSI/ICC A117.1 404.2.2 - CLEAR WIDTH C. Surface slope shall not exceed 1:48 in all directions � Detail 'Eo Maximum o.5 2' 5" 6' 9" 11' provided, the height of the tactile upper case letter "f' shall be permitted to be �" Accessible storage elements shall comply with at least one of the reach ranges specified <br /> A. Doorways shall provide a clear opening of 32° minimum, with the door open 90'. (Note : no built up curb ramp may be located in an accessible parking access 6� MIN. Reach Depth minimum. in Section 308. <br /> 1. Clear opening shall be measured between the face of the door and opposite stop. aisle.) 0 A ITIO TO C NC klaximum qg. � 47 ,w. 36" 34 <br /> 2. 0 enin s more than 24 in de th shall rovide a clear o enin of 36" minimum. Reach Heiqht ANSI/ICC A117.1 905.4 - OPERABLE PARTS <br /> p 9 P P P 9 ANSI/ICC At17.1 703.2.5 - CHARACTER WIDTH Date: <br />• ANSI/ICC A117.1 604.4 - HEIGHT (REFERENCE DETAIL) � p Operable parts of storage facilities shall comply with Section 309. �O�Z4�16 <br /> ANSI/ICC A117.1 502J - SIGNAGE (REFERENCE DEfAIL) A. Width: Yhe uppercase letter 0 shall be used to determine the allowable width of all <br /> A. The height to the top of the toilet seat shall be 17" - 19" above floor. <br /> ANSI/ICC A117.1 404.2.3 - MANEUVERING CLEARANCES AT DOORS A. Each accessible parking space must have individual vertically mounted or suspended characters of a font, and shall be 55� min. and 110� max. of the height of the • <br /> Provide level 1:48 max. slo e and clear maneuverin area at doors as follows: si n. Re uired van accessible s aces must be desi nated. 1. Seats shall not be sprung to return to a lifted position. �eSl n: <br /> ( P ) 9 9 q P 9 uppercase "I" of the font. g <br /> A. Front approach pull side -360" min. width & 18° min. beside strike edge B. Characters and symbols on such signs shall be located 60" minimum above the ANSI/ICC A117.1 604.5 - GRAB BARS (REFERENCE DETAILS) <br /> Front appraach push side - 48" min width & 0" beside strike edge ground. A. For water cl�ts not located in toilet stalls, the following grab bars shall tre Drawn: <br /> (17' � strike if door has both a closer and a latch) CLEAR FLOOR SPACE <br /> a ANSI ICC A117.1 503.5 - VERTICAL CLEARANCE p r o v i d e d, 3 3" - 3 6" a b o v e t h e f i n i s h f l o o r: o 0 <br /> B. Hinge side approach pull side - 60" min. width; 36" min. beside strike edge or - � 1. Side wall horizontal: 42° in length minimum, 17' max from rear wall, extending Z A. Floor space shall comply with ANSI/ICC A117.1 305 to allow a forward, parallel <br /> Q 54" min. width� 42" min. beside strike edge A. Provide minimum vertical clearance of 114" at accessible passenger loading zones p � ,,, Z � approach or both. Pr0 eCt N0: <br /> � � an d a lon a t leas t one ve hic le access rou te from si te en trances an d exi ts. 54 min. from rear wall � ,,,., J 16-144 <br /> a Hinge side approach push side - 42" min. width & 22" min. beside hinge edge 9 2. Side wall ve�tical: 18" in length minimum, bottom of bar located 39" min/41" 3 � � <br /> N (4gmin. width if door has both a closer and a latch) max. above the floor, centerline 39" min 41" max from rear wall � = x = _,�, HEIGHT <br /> ~i C. Latch side approach pull side - 48" min. width and 24 min. beside strike edge ANSI/ICC A117.1 503 - PASSENGER LOADING ZONE � � � � � � � � 5 � b � A. Operable parts shall be placed within one or more of the reach ranges specified in Approved: KCR <br /> � A. Passenger loading zones shall provide an access aisle at least 60" wide and 20 ft 3. Back wall; 36" in length minimum, extend from centerline of water closet 12" � ao ANSI/ICC A117.1 section 308, summarized earlier in this sheet. <br /> r (54 min. width if door has a closer) long adjacent and parallel to the vehicle pull-up space. If there are curbs between min. on side closest to the wall, 24 min. on transfer side. N Q <br /> � Latch side approach push side - 42" min. width and 24 min. beside strike edge the access aisle and the vehicle pull-up space, then a curb ramp complying with B u i I d i n g N 0: <br /> � (48"min. width if door has a closer) 4.7 shall be provided. Vehicle standing spaces and access aisles shall be level with ANSI/ICC At17.1 604.6 - FLUSH CONTROLS � <br /> � surface slopes not exceeding 1:48 in all directions. A. Flush controls shall be hand operated or automatic, and located on the open side of R-TOILET SEAT R-PAPER TOWEL S-ELECTRIC R-PAPER R-SANITARY R-WASTE <br /> o ANSI/ICC A117.1 404.2.4 - THRESHOLDS AT DOORWAYS the water closet. Hand operated flush controls shall comply with Section 309. THIS SHEET IS PROVIDED FOR YOUR CONVENIENCE. IT CONTAINS SELECTIONS FROM THE <br /> A. Maximum threshald height: t/2". Raised thresholds and floor level changes shall be COVER DISPENSER/ HAND DRYER TOWEL NAPKIN RECEPTACLE CURRENT ACCESSIBILIT( REFERENCED STANDARDS (2015 IBC CHAPTER 11 WITH WA STATE <br /> C° beveled with a slope no greater than 1:2 IBC with WA STATE AMENDMENTS 1101.2.5 - FLUSH CONTROLS DISPENSER WASTE DISPENSER DISPENSER AMENDMENTS AND ANSI/ICC A117.1), BUT IS NOT INTENDED TO BE A COMPLETE OR Sheet No: � <br /> o A. Hand operated flush controls shall comply with Section 309, except the RECEPTACLE EXHAUSTIVE COPY OF THE CURRENT ACCESSIBILITY STANDARDS. <br /> � maximum height above the floor shall be 44". <br /> COPYRIGHT CRAF7 ARCHITECTS 2016 <br />