My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
5700 23RD DR W 2017 Plans 2022-10-27 (5)
>
Address Records
>
23RD DR W
>
5700
>
Plans
>
5700 23RD DR W 2017 Plans 2022-10-27 (5)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/27/2022 10:55:31 AM
Creation date
8/23/2018 2:54:29 PM
Metadata
Fields
Template:
Address Document
Street Name
23RD DR W
Street Number
5700
Permit
M1702-049
Year
2017
Notes
NORTHSHORE CHRISTIAN ACADEMY - MECHANICAL FOR EDUCATIONAL BUILDING
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
13
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
� 9. Allowable fan motor horsepower shall not exceed cooling loads greater than 5 watts/ftZ shall be ■ <br /> a 90%of the allowable HVAC fan system bhp provided with separate,independent HVAC : t� <br /> n (Option 2)as defined by Section C403.2.11.1. systems to allow the VAV air handlers to turn off o <br /> � 10. All fan powered VAV terminal units(series or during unoccupied hours in the office space and to 0 <br /> : parallel)shall be provided with electronically allow the supply air temperature reset to occur. o <br /> : commutated motors.The DDC system shall be Exception: The VAV air handling unit and : <br /> : configured to vary the speed of the motor as a VAV terminal units may be used for secondary : <br /> : function of the heating and cooling load in the backup cooling when there is a failure of the o <br /> : space.Minimum speed shall not be greater than 66 primary HVAC system. e <br /> : percent of design airflow required fbr the greater of Additionally,server rooms,electronic equipment : <br /> : heating or cooling operation.Minimum speed shall rooms,telecom rooms,or other similar spaces shall 0 <br /> o be used during periods of low heating and cooling be provided with airside economizer per Section e <br /> 0 operation and ventilation-only operation. 403.3 without using the exceptions to Section a <br /> : Exception: For series fan powered terminal C4033. e <br /> : units where the volume ofprimary air required to Exception:Heat recovery per exception 9 of : <br /> : deliver the ventilation requirements at minimum Section 403.3 may be in lieu of airside : <br /> : speed exceeds the air that would be delivered at economizer for the separate,independent HVAC : <br /> : the speed defined above,the minimum speed system. : <br /> � setpoint shall be configured to exceed the value 15. HVAC system central heating or cooling plant will � <br /> ■ required to provide the required ventilation air. include a minimum of one of the fbllowing . <br /> � 11. Fan-powered VAV terminal units shall only be options: : <br /> : permitted at perimeter zones with an envelope 15.1. VAV terminal units with hydronic heating : <br /> : heating load requirement.All other VAV terminal coils connected to systems with hot water : <br /> : units shall be single duct terminal units. generation equipment limited to the : <br /> � 12. When in occupied heating or in occupied deadband fbllowing types of equipment: gas-fired o <br /> � between heating and cooling all fan powered VAV hydronic boilers with a thermal ' <br /> : terminal units shall be configured to reset the efficiency,Et,of not less than 90 percent, ; <br /> : primary air supply setpoint,based on the VAV air air-to-water heat pumps or heat recovery : <br /> : handling unit outdoor air vent fr•action,to the chillers. : � <br /> ; minimum ventilation airfl.ow required per 15.2. Chilled water VAV air handing units : <br /> : International�Lfechanical Code without utilizing connected to systems with chilled water e <br /> : exceptions 2,3,or 4 of Section C403.4.4. generation equipment with IPLV values : <br /> % 13. Spaces that are larger than 150 square feet(14 m2) more than 25 percent higher than the : <br /> : and with an occupant load greater than or equal to minimum part load efficiencies listed in : <br /> : 25 people per 1000 square feet(93 m2)of floor area Table C403.23(7),in the appropriate size e <br /> a (as established in Table 4033.1.1 of the category, using the same test procedures. : <br /> : International�Llechanical Code)shall be provided Equipment shall be listed in the : <br /> : with all of the fbllowing features: appropriate certification program to : <br /> ° 13.1. A dedicated VAV terminal unit capable of qualify.The smallest chiller or : <br /> o controlling the space temperature and compressor in the central plant shall not : <br /> ° minimum ventilation shall be provided. exceed 20%of the total central plant : <br /> ; 13.2. Demand control ventilation(DCV)shall cooling capacity or the chilled water � <br /> ° be provided that utilizes a carbon dioxide system shall include thermal storage sized . <br /> ■ sensor to reset the ventilation setpoint of fbr a minimum of 20%of the total central m <br /> � the VAV terminal unit from the design cooling plant capacity. o <br /> a minimum to design maximum ventilation 16. The DDC system shall include a fault detection and ■ <br /> • rate as required by Chapter 4 of the diagnostics(FDD)system complying with the a <br /> : International�Llechanical Code. following: e <br /> 0 133. Occupancy sensors shall be provided that 16.1. The fbllowing temperature sensors shall a <br /> : are configured to reduce the minimum be pernianently installed to monitor : <br /> ; ventilation rate to zero and setback room system operation: a <br /> ; temperature setpoints by a minimum of 16.1.1. Outside air. : <br /> 0 5°F,fbr both cooling and heating,when 16.1.2. Supply air. e <br /> � the space is unoccupied. 16.13. Return air. o <br /> a 14. Dedicated server rooms,electronic equipment 16.2. Temperature sensors shall have an a <br /> a rooms,telecom rooms,or other similar spaces with accuracy of t2°F(1.1°C)over the range ; � <br /> - of 40°F to 80°F(4°C to 26.7°C). a <br /> CE-70 2015 Washington State Energy Code <br />
The URL can be used to link to this page
Your browser does not support the video tag.