Laserfiche WebLink
COPYRlGHT NOTICE <br /> nNs.oa�r�u n��►� <br /> �a r�ae►nac�u n�a�a�cr� <br /> ar� r�n�rr oF��a�u n� <br /> ca�r�a�n �or�rr��ar�, <br /> NASH AtO HNL�I�S. P.S. t� <br /> PRRT SHAIJ.�f�, <br /> Di1PLlGATED� �OR <br /> iN�AWiLdIBLE PO 0�OR t�D 10 <br /> Niif EXfEHi �AS <br /> TELECOM CIRCUITS LIGHTING PANEL�OA�DS CIRCUITS WORK DEFINITION ����� <br /> EMER(�NCY NORMAL <br /> ♦ OUTLET (WALL MOUNTED) N/A LOWER-CASE LETTER NEAR FIXTt1RE DENOTES SWITCH LEG, TYP 208V SYSTEM PANELBOARD --�— RACEWAY CONCEALED IN CEILING OR WALL. HASH MARKS � FLAG NOTE �, <br /> a <br /> INDICATE NUMBER OF WIRES. #12 AWG WIRE UNLESS OTHERWISE � <br /> � OUTLET (FLOOR, FLUSH MOUNTED) � 0 RECESSED RECI'Ai�GULAR FIXTURE, DRAWN TO SCALE � 480V SYSTEM PANELBOARD NOTED. EXPOSED RACEWAY IS ALLOWED ONLY WHERE NOTED. � REVISION IDENIIFICATION <br /> � OUTLET (CEILING MOUNTED) � RECESSED BASKET FIXTURE, DRAWN TO SCALE ELECTRICAL RISER �� HOT (SHORT HASH MARK) � EQUIPMENT IDENTIFICATION <br /> WAP WIRELESS ACCESS POINT Q SURFACE MOUNTED RECTANGULAR FIXTURE, DRAWN TO SCALE —}-- NEUTRAL (LONG HASH MARK) # EQUIPMENT IDENTIFICATION z z <br /> _ . • ARRESTOR, SURGE � o <br /> ❑ O RECESSED DOWNLIGHT FIXTURE --� GROUND WIRE (JOGGED HASH MARK� Det# DETAIL REFERENCE � � <br /> TELE�OM OUTLET TYPES � a ARRESTOR, LIGHTNING Sheet# � � <br /> . LIGHTING SWITCHES AND C�NTROLS EXISTING RACEWAY (IF HASH MARKS ARE SHOWN, PULL NEW Det# � DETAIL REFERENCE W�ORIGINATING SHEET REFERENCE �sI�Y �� E�IE���� <br /> �`� AUTOMATIC TRANSFER SWITCH CONDUCTORS� Plansheet� DetSheet# � <br /> � � ��'�tEWE� FC�R ����l��' <br /> '� INDICATES QUANTITY OF DATA JACKS. PULLSTRING ALWAYS � a LOWER-CASE LETTER NEAR SWITCH DENOTES CIRCUIT RACEWAY BELOW SLAB OR UNDERGROUND � <br /> PROVIDED. WHERE NO QUANTITY IS NOTED, 2 DATA JACKS AND CONTROLLED (TYP) PS ACE BUS SPACE � a D PROJECT NORTH REFERENCE <br /> PULLSTRING. � <br /> � RACEWAY UP TNB � <br /> SINGLE POLE SWITCH BUS DUCT "°�t� � <br /> � AC MOUNTED 3" ABOVE COUNTER BACKSPLASH � 2 DOUBLE POLE SWITCH BUSWAY END TAP BOX �� RACEWAY DOWN a D <br /> PROJECT NORTH REFERENCE W/TRUE NORTH REFERENCE <br /> � NEW WORK ,..� d- <br /> � B BLANK FACEPLATE (ROUGH-IN ONLY) � 3 3-WAY SWITCH � RACEWAY STUB-OUT WITH BUSHING � r� <br /> � �.M <br /> CABLE TO BUS CONNECTION EXISTING � �� <br /> �' � DIRECT CONNECTION TO PANEL (PANEL BY I�THERS) $ 4 4-WAY SWITCH --� CIRCUIT CONTINUATION �N <br /> M � I CAPACITOR - - - - FUTURE '� � <br /> `� PATIENT MONITORING (� DIMMER SWITCH I I � CONTACT, NORMALLY OPEN AND NORMALLY CLOSED �� HOME RUN TO PANEL OR LOCATION NOTED / � �j �¢ <br /> � P PAY TELEPHONE �S � CONTROL STATION INDICATES STATION IDENTIFICATION �XxxX R E M O V E E X I S T I N G E L E C T R I C A L E Q U I P M E N T � �- � x <br /> � � # � CIRCUIT BREAKER Q� JUNCTION BOX � � W� <br /> �' R RACEWAY MOUNT�D DSC DIMMING SYSTEM CONTROLS CENERAL NOTES � � � O <br /> �' W TELEPHONE HANDSET OUTLET WALL MOUNTED ELCU ��-- CIRCUIT BREAKER, DRAWOUT <br /> � �,, o <br /> ( ) �� EMERGENCY LIGHTING CONTROL UNIT ��� 1. COMPLY WITH THE NATIONAL ELECTRICAL CODE AS ADOPTED AND AMENDED BY THE LOCAL � � a�oC°o <br /> ���L_I�� CIRCUIT BREAKER, DRAWOUT, MEDIUM VOLTAGE CIRCUITS RECEPTACLES AUTHORITY HAVING JURISDICTION. � � �� <br /> OS CEILING MOUNTED OCCUPANCY SENSOR SWITCH �F �+�c�,cY NORMAL � <C N� <br /> TELEGOM - MISCELLANEOUS � CIRCUIT BREAKER, GFI 2. THE LOCATIONS OF ELECTRICAL DEVICES OR LIGHTING FIXTURES INDICATED ON ARCHITECTURAL PLANS ;`j <br /> PC PC PHOTOCELL CONTROL GF �D � SINGLE RECEPTACLE 120V ELEVATIONS OR SECTIONS TAKE PRECEDENCE OVER LOCATIONS INDICATED ON THE ELECTRICAL e N <br /> _���� CIRCUIT BREAKER, G�I WITH DRAWOUT DRAW1NGS. ��' <br /> � CABLE TRAY WITH FLANGE SIDE RAILS AND LADDER RUNGS PS PHOTO SENSOR CONTROL � � �' <br /> � CIRCUIT BREAKER, MAGNETIC OVERLOAD DUPLEX RECEPTACLE 120V 3. REFER TO THE ARCHITECTURAL REFLECTED CEILING PLANS FOR EXACT LIGHTING FIXTURE LOCATIONS. o 0 <br /> � <br /> Na <br /> � RUNWAY CABLE TRAY R RELAY, NEC CLASS II 4. FOR LIGHTING CONIROLS WHICH INCLUDE DAYLIGHT OR OCCUPANT SENSING AUTOMATIC CONTROLS, N� <br /> � CIRCUIT BREAKER, NETWORK PROTECTOR � DOUBLE DUPLEX RECEPTACLE 120V <br /> �' BUNDLED CABLE SUPPORT, J-HOOK SYSTEM T LOW VOLTAGE 1RANSFORMER AUTOMATIC SHUT-OFF CONTROLS, OCCUPANCY SENSORS, OR AUTOMATIC TIME SWITCHES THE <br /> � sr"��� CIRCUIT BREAKER, THERMAL OVERLOAD RECEPTACLE TYPES EQUIPIMENT�ANDOSY TEMS ARE CALIBRAT�EDNADJUSTEDTA DN P�RATEINESACCORD�NCETWI <br /> � TELECOMMUNICATIONS GROUNDING BAR TH <br /> PROJECT PLANS AND SPECIFICATIONS. SEQUENC� OF OPERATION SHALL ALSO BE FUNCTIONALLY <br /> � �FUSE OR CURRENT LIMITER AC TESTED TO ENSUFtE IT IS OPERATING IN ACCORDANCE WITH PROJECT PLANS AND SPECIFICATIONS. A <br /> TELECOMMUNICATIONS MAIN GROUNDING BAR � MOUNTED 3" ABOVE COUNTER BACKSPLASH COMPLETE REPORT OF TEST PROCEDURES AND RESULTS SHALL BE PREPARED AND FILED WITH THE <br /> ,� FUSE (ISOLATING) p OWNER. <br /> DEDICATED CIRCUIT <br /> � FUSED SWITCH <br /> � �� GROUND FAULT CIRCUIT INTERRUPTER <br /> -�- GROUND <br /> A��REVIATION5 <br /> DRAWIN� LIST ��T GROUND FAULT CIRCUIT INTERRUPTER AND TAMPER RESISTANT <br /> PUSHBUTTON � � ABV ABOVE MAG MAGNETIC � <br /> E0.1 ELECTRICAL SYMBOLS AND ABBREVIAl10NS � � ISOLATED GROUND AC 3" ABOVE COUNTER BACKSPLASH MCC MOTOR CONTROL CENTER � <br /> E1.1 ELECTRICAL KEY PLAN � SPLICE <br /> E2.1 ELECTRICAL DEMOLITION PLAN AND ELECTRICAL PLAN <br /> E3.1 LIGHTING DEMOLITION PLAN AND LIGHTING PLAN � T TAMPER RESISTANT ACH ABOVE COUNTER HEIGHT MH MANHOI_E <br /> E4.1 POWER ONE-LINE DIAGRAM Q STRESS RELIEF, MEDIUM VOLTAGE WP GROUND FAULT CIRCUIT INTERRUPTER WITH WEATHER PROOF AFF ABOVE FINISHED FLOOR MM MULTIMODE s�'°' � <br /> E4.2 PANEL SCHEDULES COVER <br /> AG ABOVE GRADE MTD MOUNTED C <br /> a� 5WITCH, 2-POLE A,AMP AMPERE MW MICROWAVE <br /> E4.3 PANEL SCHEDULES � <br /> E4.4 LQAD CALCULATIONS H � <br /> E5.1 GE X-RAY ELECTRICAL LAYOUTS � A CONTROLS A/V AUDIO/VISUAL N NEUTRAL � � <br /> E5.2 GE X-RAY ELECTRICAL LAYOUTS � � SWITCH, 3-POLE NIC NOT IN CONTRACT � � <br /> E5.3 GE X-RAY ELECTRICAL DETAILS ATS AUTOMATIC TRANSFER SWITCH � <br /> E6.1 SIEMENS X-RAY ELECIRICAL LAYOUTS p � FUSED DISCONNECT SWITCH (FUSE RATING I�IDICATED) AWG AMERICAN WIRE GAUGE OPER OPERATER/OPERABLE <br /> E6.2 SIEMENS X-RAY ELECTRICAL LAYOUTS � THERMAL ELEMENT � CATV COMMUNITY ACCESS TELEVISION OP01 OWNER PROVIDED OWNER INSTALLED <br /> � � DISCONNECT SWITCH CB CIRCUIT BREAKER PB PULLBOX � <br /> � m TRANSFORMER <br /> OUTLET MOUNTING HEI�HTS MOTOR STARTER CCTV CLOSED CIRCUIT TELEVISION PNL PANEL, PANELBOARD p <br /> (� TRANSFORMER, CURRENT <br /> CKT CIRCUIT POS POSITION/POINT OF SALE � � <br /> �� MANUAL MOTOR STARTER <br /> SPECIAL OUTLET HEIGHTS ARE SHOWN ON THE ELEC7RICAL DRAWINGS OR ON THE ARCHITECTURAL �„Y,� TRANSFORMER, ELEC7ROSTATICALLY SHIELDED, MAGNETIC CORE CLG CEILING PR PAIR � � <br /> DRAWINGS. IF SPECIAL OUTLET HEIGHTS ARE NOT SHOWN OR REQUIRED, THEN LOCATE OUTLETS AS �� SHOWN COMBINATION MOTOR STARTER FUSED DISCONNECT SWITCH CM CEILING MOUNTED PTS PNEUMATIC TUBE STATION � <br /> NOTED BELOW. OUTLET HEIGHTS ARE MEASURED FROM THE FINISHED FLOOR TO THE CENTERLINE OF � TRANSFORMER, MAGNETIC CORE SHOWN � � <br /> ENCLOSED CIRCUIT SREAKER COMM COMMUNICATIONS R RACEWAY <br /> THE OUTLET UNLESS OTHERWISE NOTED. C CONDUIT RO RACEWAY ONLY <br /> r�� M <br /> RECEPTACLES 18 INCHES (460 mm) VERTICALLY MOUNTED ��� TRANSFORMER, SHIELDED, MAGNETIC CORE SHOWN � MOTOR RATED TOGGLE SWITCH CO CONDUIT ONLY RECEPT RECEPTACLE <br /> SWITCHES 43 INCHES (1095 mm) VERTICALLY MOUNTED L��J CTRL CONTROL REF REFRIGERATOR � T <br /> �R RELAY, CONTROL TYPE � � � Q <br /> A AMMETER CU COPPER SLV SLEEVE � oF �'AS,yI <S' <br /> 72 INCHES (1830 mm) TO TOP OF PANELBOARD IF BOX < 68 ,��'�`' ��� <br /> PANELBOARDS INCHES (1730 mm) HIGH, OTHERWISE PER NEC 404.8 EQUIPN1ENT o DATA SM SINGLEMODE � ' ,�, <br /> �C CONTACTOR DED DEDICATED SPECS SPECIFICATIONS <br /> � EQUIPMENT CABINET DEV DEVICE SW SWITCH ~ 31 �� � <br /> TELECOM OUTLET, DESK HANDSET 18 INCHES (460 mm) VERTICALLY MOUNTED �G ENGINE-GENERATOR o �,� s� <br /> �� DN DOWN SWBD SWITCHBOARD � IONAL �� <br /> K KEY INTERLOCK � �E EQUIPMENT CONNECTION, E = EMERGENCY F'OWER DW DISHWASHER TELECOM TELECOMMUNICA110NS sS � <br /> TELECUM OUTLET, WALL HANDSET 43 INCHES (1095 mm) VERTICALLY MOUNTED � <br /> rr�r GROUND BAR, LENGTH TO SCALE EF ENTRANCE FACILITY TGB TELECOMMUNICATIONS GROUNDING '� "u�� <br /> �M METER - ,�� <br /> ER EQUIPMENT ROOM/EMERGENCY BUSBAR �� <br /> PM POWER METER ROOM TMGB TELECOMMUNICATIONS MAIN �_�8_�y <br /> � �R RELAY �I�HTIN� FIXTURE SCHEDUL� Ewc ELECIRIC WATER COOLER GROUNDING BUSBAR �� � <br /> � LAMP INPUT FA FIRE ALARM TR TELECOMMUNICATIONS ROOM � <br /> �, � RELAY, GF) ALTERNATE ,pi� � <br /> m TYPE DESCRIPTION MANUFACTURER MANUFACTURERS # CODE WATTS VOLT* COMMENTS FB FLOOR BOX TV TELEVISION �� <br /> � SURGE PROTECTIVE DEVICE L1 2X2 LENSED TROFFER LED 3500K LITHONIA 2GTL2 OR APPROVED EQUAL 1 34 MVOLT FBOIC FURNISHED BY OTHERS, INSTALLED TYP TYPICAL <br /> � , � , ; , 4000 LUMEN BY CONTRACTOR UF UNDER FLOOR �� <br /> ' ` ' ' " ' L2 RECESSED 6"ROUND APERTURE LITHONIA LDN6 LIGHTOLIER 1 LED-Wl-fITE- 27 MVOLT <br /> � ', . ;:� � '; __- - . '� �,` �`` V VOLTMETER <br /> o � �' , ;� � � :� � LED DOWNLIGHT,NOMINALLY 7- LYTEPROFILE; INTEGRAL TO FI FILM ILLUMINATOR UG UNDER GROUND <br /> 1/2 R E C E S S D E P T H. 1 6-G A U G E A T L A N T I C L I G H T I N G F I X T U R E, UON UNLESS OTHEftWISE NOTED ��������'�L <br /> � ! ' WHM WA7T HOUR METER GALVANIZED STEEL MOUNTING LED6 SERIES;OR 2,400 LUMEN FO FIBER OPTIC(AL) �Y����� ��� <br /> _ +t► FRAM WITH TRIM CLIPS 70 APPROVED EQUAL INITIAL FOC FACE OF COLUMN UTP UNSHIELDED TWI5TED PAIR �����VI�T,�ONa�' . <br /> Q MOUNT OPEN CONICAL SHAPE FIXTURE G,GND GROUND V VOLT OR VOICE � <br /> o REFLECTOR.GALVANIZED STELL OUTPUT, VEL VERIFY EXACT LOCATION <br /> i JUNCTION BOX WITH BOTTOM- MEDIUM BEAM GD GARBAGE DISPOSAL <br /> � <br /> QHINGED ACCESS COVER AN DISTRIBUTION GFI,GFCI GROUND FAULT CIRCUIT <br /> ¢ SPRING LATCHES.0-10V W WIRE, WATT, OR WALLPHONE <br /> j WAP WIRELESS ACCESS POINT Permit#: E17os-zao <br /> ELECTRONIC DIMMING DRIVER. INTERRUPTER Site Address: 128�019TFf AVE SE <br /> � HH HAND HOLE � WEATHERPROOF Owner: PROVIDENCE HEALTFf&SERVICES <br /> � L3 2X4 LENSED TROFFER LED 3500K LITHONIA 2GTL4 OR APPROVED EQUAL 1 31 MVOLT Tenant: PRMC RADIOLOGY <br /> 0 <br /> � 4000�UMEN XFMR TRANSFORMER <br /> HP HORSEPOWER App. Qate: 8/30/2017 <br /> i IDF INSTA-HOT WATER DISPENSER � PHASE Prapased Use: COMMERCIAL <br /> w Descriptian: FEEDER T�XRAY ROOM-PRMC <br /> � *Voltage(s) listed are options available. Refer�electrical drawings for ach�al voltage. J—BOX JUNCTION BOX �0�% ��-�T�r�-r�� T��T�� T ���� <br /> i <br /> o l�l � t,� 1 l�I Reviewed B Date: <br /> y: ,� ��_/�/i� <br /> % /t Office Set 1ob Site Set Fire/Planning Set <br /> > ' ' <br />