Laserfiche WebLink
c <br />d <br />t1 25'-7Y2" <br />5'_9 ° 19'-10Y2" <br />7'-3Y2" 7'- 2Y2„ 5,_ 4Y2„ <br />1 <br />7-0 5 0 DSL I <br />b <br />..................•.. <br />D1 <br />2 <br />................... <br />N <br />- EGRESS 2 <br />D3 <br />C <br />D3 <br />1 <br />4-------- <br />----- <br />1 <br />................................. <br />D1 <br />a <br />1 <br />Master Bedroom <br />F <br />STEP'j <br />N <br />- <br />o <br />I <br />P14 <br />I <br />! <br />W.I.C. <br />D1 <br />PLANT SHELF °' <br />�- <br />1 <br />j <br />@ 9" ABOVE <br />DOOR HEAD <br />81'-9Y2" <br />E11 <br />4'-10Y2" 3'-9» 3'-2" <br />1\ D1 <br />• 's <br />2-6 <br />1 <br />HCW................................ <br />2 <br />N <br />N <br />fillibnO 2-6 <br />,1 <br />48"x34" BIFOLD <br />M. Bath SHOWER LOW WALL N <br />O;�� II <br />Zx6WALL42 A.F.F.-- <br />[ 1 <br />1 <br />\ 3'-2" I <br />E)` O D5 <br />LOCATE j <br />24" TB TP DN <br />o <br />PLUMBING <br />z <br />2 "? <br />D1 0 CID <br />r--� <br />m <br />CN <br />ROUGH IN 15 <br />ACCOUNTING <br />D3 <br />FOR SHEAR <br />1 wtTp <br />WASHR <br />PANELING <br />AND (2) <br />(; ,_0 <br />11 Q o Q ( I <br />I J <br />Ln <br />LAYERS GWB <br />AT COMMON <br />WALL <br />1 Bath 18 nd r <br />-4 HCW D1 y cn <br />1' 24" TB .- <br />II <br />2-8 HCW I DRYS <br />:N <br />N <br />1 <br />1--------- -6 HCW 722"x30,� <br />N <br />N <br />1 I ATTIC I <br />( ACCESS <br />4-0 BIPASS <br />1 AT STEP 6-0 BIPASS o <br />1 18 = <br />N <br />14 8 N <br />1 D3 D1 5'-11Y2" 4'_0" 3 _g° 7'-10)12„ <br />1 Bedroom Bedroom 2 2 1 <br />I D3 D1 <br />'1 <br />1 1 `` <br />D1 <br />CN <br />2 1 <br />2 D1 <br />2 0------------- <br />D3 cv CD <br />---- EGRESS N <br />:............. <br />EGRESS <br />.............: 6-0 �-0 SL <br />N O T E S <br />FRAMING: 2x6's AT EXTERIOR WALLS <br />2x4's AT INTERIOR WALLS <br />UNLESS NOTED OTHERWISE. <br />SEE S1.1 FOR STUD SCHEDULE. <br />.................. R-21 BATT INSULATION <br />- - - - - - 3Y2" ACOUST. INSUL. EACH SIDE <br />OF PARTY WALL, UNO. <br />CONCEALED SPACES SHALL BE FIRESTOPPED IN BOTH <br />DIRECTIONS AT 10'-0" ON CENTER AND AT FLOORS. <br />TYPI CAL. <br />ALL ESCAPE OR RESCUE WINDOWS FROM SLEEPING <br />ROOMS SHALL HAVE A MINIMUM NET CLEAR OPENING <br />OF 5.7 SQUARE FEET. THE MINIMUM CLEAR OPENING <br />HEIGHT DIMENSION SHALL BE 24". THE MINIMUM CLEAR <br />OPENING WIDTH DIMENSION SHALL BE 20". SILL <br />HEIGHT SHALL BE NOT MORE THAN 44" ABOVE THE <br />FLOOR PER IRC SEC. R310.1.1. <br />WHERE SILL AT OPERABLE WINDOW IS LOCATED MORE <br />THAN 72 INCHES ABOVE FINISHED GRADE OR OTHER <br />SURFACE BELOW, SILL HEIGHT SHALL BE MINIMUM 24 <br />INCHES ABOVE FINISHED FLOOR. PER IRC SEC. 312.2.1. <br />ALL GLAZING SHALL CONFORM TO IRC SEC. R308.4, <br />HAZARDOUS LOCATIONS. GLAZING IN ALL DOORS SHALL <br />BE SAFETY GLAZED. ALL GLAZING WITHIN A 24" ARC <br />OF EITHER VERTICAL DOOR EDGE SHALL BE SAFETY <br />GLAZED. ALL GLAZING WITHIN 60" OF A HAZARDOUS <br />LOCATION, OR "WET SURFACE" SHALL BE SAFETY <br />GLAZED. <br />PROVIDE 5/s" (MIN.) GYPSUM SHEATHING ON <br />WALLS BEHIND TUB/SHOWERS TO SATISFY FIRE <br />REQUIREMENTS AT UNIT SEPARATION WALLS CONDITION, <br />5-0 +5-0 SL <br />5,-0" 1 5,_1y" 5,-0" 6'-4y2" <br />10'-1Y2" 11'- 4Y2" <br />21'-6" <br />UPPER LEVEL <br />UNIT G FLOOR PLAN <br />1 /4"=l'-O" <br />THE FIREPLACE SHALL BE LISTED BY UL OR FM AND <br />SHALL BE INSTALLED IN ACCORDANCE WITH THAT <br />LISTING <br />PROVIDE WATER RESISTANT GYPSUM WALLBOARD <br />BEHIND TUB AND SHOWER ENCLOSURE MATERIALS <br />TO A HEIGHT OF 70" MINIMUM ABOVE THE <br />DRAIN INLET. <br />NO PLUMBING, MECHANICAL EQUIPMENT, DUCTS OR <br />VENTS SHALL BE LOCATED IN THE COMMON UNIT <br />SEPARATION WALLS PER IRC SEC. R302.2 (EXCEPTION) <br />ALL BEDROOM AND BATHROOM DOORS SHALL BE <br />UNDERCUT A MINIMUM OF %" ABOVE THE ADJACENT <br />FLOOR COVERING. <br />THE FRONT DOOR SHALL BE OPENABLE FROM THE <br />INSIDE WITHOUT THE USE OF A KEY OR ANY SPECIAL <br />KNOWLEDGE OR EFFORT. IT MAY BE PROVIDED WITH A <br />NIGHT LATCH, DEAD BOLT OR SECURITY CHAIN, <br />PROVIDED SUCH DEVICES ARE OPENABLE FROM THE <br />INSIDE WITHOUT THE USE OF A KEY OR TOOL, AND <br />MOUNTED NOT TO EXCEED 48" ABOVE THE FINISHED <br />FLOOR. <br />STAIR NOTES: <br />LOCATE HANDRAILS AT 34'-38" ABOVE THE <br />STAIR NOSING. <br />HANDRAIL GRASP DIMENSION SHALL BE BETWEEN 1" & <br />1-1/4". PROVIDE CONTINUOUS HANDRAIL OR <br />TERMINATE <br />AT NEWEL POSTS OR SAFETY TERMINAL. <br />WHERE USED AS A GUARDRAIL, A MAX. OPENING OF <br />4". <br />GYPSUM WALLBOARD SCHEDULE <br />V GYPSUM WALLBOARD (GWB) SHALL BE <br />USED THROUGHOUT ON INTERIOR WALLS, <br />INTERIOR SIDE OF EXTERIOR WALLS AND <br />CEILINGS EXCEPT AT EXTERIOR WALLS AND <br />COMMON WALLS REQUIRED TO HAVE A 1-HR <br />OR 2-HR FIRE -RESISTANCE RATING IN <br />WHICH CASE V8" TYPE 'X' GWB SHALL BE <br />USED. <br />INSULATION <br />FOUNDATION PERIMETER - R-10 RIGID <br />INSULATION TO A DEPTH OF 24" OR TO TOP <br />OF FOOTING AT HEATED PERIMETER <br />WALLS: 2x6 WALLS WITH FIBERGLASS BATTS <br />OR BLANKETS - R21 <br />FLOORS OVER UNHEATED SPACES - R-30 <br />ATTICS AT TRUSSES - R-49 <br />(R-38 SHALL BE DEEMED TO SATISFY THE <br />REQUIREMENT OF R-49 WHEREVER THE FULL <br />HEIGHT OF UNCOMPRESSED INSULATION EXTENDS <br />OVER THE WALL TOP PLATE AT THE EAVES) <br />EXTERIOR DOORS: DOORS BETWEEN HEATED <br />AND UNHEATED SPACES SHALL BE U=0.30 <br />OR BETTER <br />WINDOWS: ALL WINDOWS AND SGD TO HAVE <br />U-FACTOR OF U=0.30 OR BETTER <br />INSULATE UNDER STAIRS AND IN WALL <br />CAVITIES ABOVE BOTTOM OF STRINGERS <br />25'- 7Y2„ <br />5'-9" 14'-6" 5 -4Y2" <br />2'-13�43'-7y4„ 3'-9y2„ 5-6„ 5,_2Y2» <br />l D4 <br />1 <br />1Y4» 14'-3Y2 1,4 <br />„ <br />I I <br />Deck, <br />11 1n <br />, D4 <br />I -� 7-0 14-0 DSL <br />............. <br />1 _ <br />o I <br />SAFETY GLAZING 1 <br />20 D1 <br />1-0 3�O SH j I b D5 0 <br />}�....... I TOP AT i <br />T� --� + 51 A.F.F. <br />1 18" TB 00 <br />f� Pwdr. (- � Living o ---------------- <br />i <br />pj _ - <br />iDIRECT VENT @-4 <br />FIREPLACE p <br />N <br />1 2ni <br />4 N <br />6'_2Y" 15" D o V-4" 3'-6» D6 <br />................... <br />SIM. <br />p ������.' ----------------- -------------- ---------------- - <br />.. .. .. .. <br />j <br />r. 1 .. .. •________________ <br />1 O � \ <br />10"lo <br />G1, <br />10 N I 6`Z` z I I `1' <br />D5 � I '-----+ - <br />5,_2„ UP Q Q <br />1 I� I <br />1 FLOOR LINE I 3-0 SCW 8 I � <br />Q STEP I `V _ <br />1 18 ABOVE. 10 Entry D2-----+ - <br />=� 1 D3 Dining D5 2 <br />( I � I <br />I <br />pi ( 14 8 N U P o> ;; N <br />03 D1 - 0" 5'-4" 2 I z_ <br />1 D1 n¢¢ I N <br />D5 I cn � I t <br />1 • �- 1 <br />1------------- <br />1 19 <br />D1 _ <br />1 SIM. p - - - - - I I I <br />------ --------......... ----....... ----...... .1- ----- 4 _ <br />1' �63�4" <br />CONTINUE COMMON WALL = I <br />1 p I I 1 <br />GWB THROUGH FURRING <br />IN <br />1 TYPICAL 1 C,4,„ I I I 1 1 <br />I 1 1 1 <br />11 I i 1 1 <br />1 1 1 1 <br />1 1 <br />INSULATE FLOOR OVER <br />UNHEATED SPACE I 3 I L_ I ' _J <br />I 2 <br />I I I <br />p <br />1 18-1 <br />3'-2» 8„ >; 1 1 <br />i Family o o Kitche I <br />'00 <br />O <br />� I 1 <br />I I <br />1 j DW I 2 1 <br />1 'L- - - I <br />1 L D3 D1 <br />II <br />3 5- - - - - - - - - - - --------- - - - <br />WALL BELOW CO <br />�r <br />6------------ <br />D3 `a A <br />1 6 _ N <br />D1 D3 `y <br />...........00 7-0 15-0 DSL <br />I 5-0 5;-0 SL o <br />5'-0" 5'-1Y2" 5-0" 6'-4Y2„ <br />10'-1Y2" 11'-4Y2» <br />21'-6" <br />MAIN LEVEL <br />UNIT G FLOOR PLAN <br />1 /4"=1'-0" <br />SEE U20 FOR INTERIOR ELEVATIONS <br />AND INTERIOR STAIR PLANS <br />0 <br />cc <br />00 <br />i <br />d- <br />25'-7y" <br />5'-9" 14'-6" <br />7'-3" 7,-3" <br />-3" <br />I I <br />I ' I <br />I � I <br />I D5 I I <br />I - 6-0 16-10 SGD <br />.................. .... ........................ <br />3'- 7Y2» <br />— 2X4 FUR WALL <br />AT WH LOCATION <br />Bonus Room <br />5'-11Y2" <br />5'-4 2" I 6'-0" <br />� a N <br />1• N................................. <br />-2X4 FUR ---- <br />WALL '6 <br />CNQ UP <br />9 N z o �E t <br />� <br />Stor. <br />a <br />D2 00 <br />ry <br />I 8 ao <br />.........................................I....I D2 <br />07 0 <br />D2 I I I I I I <br />5-6" 2'-3y2" 1'-2» 7'-9h I 4'-3j/2„ m <br />L-i_s-L-1-�--- d <br />NOTE: PER IRC R302.6 MIN. <br />%" TYPE X GWB SHALL BE 2'-3Y2» <br />APPLIED TO CEILING OF GARAGE 2Y2" <br />\ WHERE HABITABLE ROOMS ARE p <br />7 ABOVE. MIN.Y2" GWB APPLIED TO p1 2 <br />ALL WALLS, BEAMS, AND POSTS N _ o <br />WITHIN GARAGE. 1 <br />a <br />Garage 2x8 FRAMING FOR <br />ELEC. ENTRANCE <br />14" CLEAR INSIDE 6 Li <br />A <br />V-9" 1 3'-10" 1 <br />1 <br />I D5 <br />ice- � 16-0 7-0 SOHD <br />I 16 11 I <br />D5 D2 <br />I I <br />--------- -----I <br />I <br />---- ---------------I <br />2'-7Y2" 16'-0" 2'-10Y2„ <br />21'-6" <br />25'-1Y2" <br />WER LEVEL <br />UNIT G LOOOR PLAN <br />1 /4"=1 '-0" <br />Sheet Order: A B U F R E S D <br />5052 REGISTERED <br />\ ARCHITECT <br />ROBERT E. WEIBLE <br />STATE OF WASHINGTON <br />� m <br />� T <br />o <br />a N <br />a� , <br />o � <br />0 <br />Z <br />c� <br />C <br />a N <br />a <br />c <br />0 <br />0 <br />F= <br />a <br />Z <br />= <br />O <br />o <br />J <br />LL <br />U <br />m Q <br />�- <br />3 <br />o <br />0 <br />0 <br />v+ _ <br />E <br />MONSOON <br />W <br />C <br />V <br />Cn <br />4) <br />C <br />U) <br />W <br />° <br />Z <br />FNNNNW <br />A-& <br />i <br />C <br />O <br />o <br />a. <br />r <br />a <br />Job No.: 13-47 <br />Sheet No.: <br />U13 <br />