Laserfiche WebLink
GENERAL NOTES <br />THIS ELECTRICAL PLAN IS THE ARCHITECT'S SUGGESTED LAYOUT. THE <br />ELECTRICAL CONTRACT IS ON A DESIGN -BUILD BASIS. ELECTRICAL <br />CONTRACTOR'S DESIGN SHALL BE APPROVED BY THE OWNER AND SHALL <br />CONFORM TO THE APPLICABLE ELECTRIC CODE REGARDLESS OF WHAT IS <br />SHOWN ON THIS DRAWING. <br />METER CENTER LOCATIONS SHALL BE COORDINATED WITH THE ARCHITECT. <br />HIGHEST OPERABLE PART OF ENVIRONMENTAL AND OTHER CONTROLS SHALL <br />MOUNTED NOT LESS THAN 36 INCHES ABOVE FLOOR. ELECTRICAL AND <br />COMMUNICATIONS SYSTEMS ON WALLS SHALL BE MOUNTED A MIN. OF 15 <br />INCHES ABOVE FLOOR. <br />OUTLETS, SWITCHES, TELEPHONE AND TV, ETC. BOXES IN PARTY WALLS OF <br />ONE UNIT SHALL BE IN DIFFERENT STUD SPACES THAN THOSE IN <br />THE ADJACENT UNIT. NO TWO ADJACENT UNITS SHALL HAVE SUCH BOXES <br />IN THE SAME STUD SPACE. BOXES SHALL BE SEPARATED HORIZONTALLY <br />�- <br />BY 24". <br />f <br />INDIVIDUAL ELECTRICAL OUTLET BOXES SHALL BE OF STEEL OR OTHER <br />j <br />W. I •C. <br />APPROVED MATERIAL AND SHALL NOT BE GREATER THAN 16 SQUARE <br />INCHES IN AREA. <br />THE WATER HEATERS SHALL BE STRAPPED PER !RC P2801.7 AT A POINT <br />I <br />I <br />I <br />I <br />WITHIN THE UPPER 1/3 AND THE LOWER 1/3 OF ITS VERTICAL DIMENSION <br />I <br />- <br />THE LOWER STRAP SHALL BE NOT LESS THAN 4" ABOVE ANY CONTROLS. <br />j <br />WATER HEATERS SHALL BE PROVIDED WITH A PRESSURE/TEMPERATURE <br />I <br />RELIEF VALVE THAT IS CONNECTED TO A DRAIN LINE. THE DRAIN LINE <br />I <br />SHALL BE DIRECTED TOWARD THE GROUND AND TERMINATE AT A POINT NO <br />I <br />LESS THAN 6" AND NO MORE THAN 24" ABOVE THE GROUND. <br />SMOKE DETECTORS SHALL BE EQUIPPED WITH A BATTERY BACK-UP, SHALL <br />EMIT A SIGNAL WHEN BATTERIES ARE LOW, SHALL BE PERMANENTLY HARD <br />WIRED AND WITHOUT A DISCONNECTING SWITCH OTHER THAN THOSE <br />REQUIRED FOR OVERCURRENT PROTECTION, AND SHALL SOUND AN ALARM <br />AUDIBLE IN ALL SLEEPING AREAS OF THE DWELLING IN WHICH THEY ARE <br />LOCATED. <br />ENERGY NOTES <br />SEE ENERGY NOTES ON SHEET Al & D5. <br />WATER HEATER SHALL BE FUELED BY GAS AND HAVE A MINIMUM EF OF <br />0.82. <br />HOT AND COLD WATER HEATER PIPES IN UNCONDITIONED SPACES SHALL BE <br />INSULATED WITH R-3 INSULATION WHICH HAS A FLAME SPREAD OF 25 OR <br />LESS. <br />VENTILATION NOTES <br />VENTILATION: SEE NOTES ON COVER SHEET. <br />ALL EXHAUST DUCTS SHALL BE RIGID METAL, AND SHALL BE FITTED WITH A <br />TIGHT FITTING BACKDRAFT DAMPER CAPABLE OF CLOSING WHEN THE FAN IS <br />NOT IN USE. <br />DUCTS IN UNHEATED SPACES INCLUDING ATTICS SHALL BE INSULATED TO A <br />MINIMUM OF R-8. <br />TOP FLOOR EXHAUST FANS SHALL VENT THROUGH ATTIC. <br />DRYER EXHAUST DUCT SHALL BE 4" RIGID METAL WITH A 4" OPENING ON <br />THE EXHAUST HOOD. THE DRYERS DUCTS SHALL BE GALVANIZED STEEL OR <br />ALUMINUM, MINIMUM 0.016" THICK. THE DRYERS SHALL BE GENERAL <br />ELECTRIC. DRYERS SHALL BE INSTALLED ACCORDING TO MANUFACTURER'S <br />INSTALLATION INSTRUCTIONS ON SITE. <br />WINDOW OUTDOOR AIR INLETS SHALL PROVIDE THE EQUIVALENT OF 4 SQ. <br />IN. OF NET FREE AREA. <br />ELECTRICAL LEGEND <br />DUPLEX RECEPTACLE OUTLET <br />DIRECTIONAL CEILING <br />MOUNTED LIGHT <br />DUPLEX RECEPTACLE OUTLET <br />SPLIT WIRED (SWITCH TOP HALF) <br />-0- <br />CEILING MOUNTED LIGHT <br />DUPLEX RECEPTACLE OUTLET <br />M <br />MICROWAVE <br />RECESSED CEILING LIGHT; <br />IC RATED -SEE 12/D1 <br />SINGLE RECEPTACLE OUTLET <br />208v (R: RANGE, D: DRYER) <br />{ <br />WALL MOUNTED LIGHT <br />Q <br />JUNCTION BOX <br />DOUBLE TUBE FLUORESCENT <br />TECH PORT <br />CEILING MOUNTED LIGHT <br />TEL.V <br />TELEPHONE JACK <br />17 <br />CEILING MOUNTED TRACK LIGHT <br />TV <br />TELEVISION JACK <br />HEAT LAMP, EXHAUST FAN <br />SINGLE POLE SWITCH <br />COMBINATION RECESSED CEILING <br />FIXTURE - 250W LAMP, 50 CFM <br />MIN., 3 SONES, 4" ROUND DUCT. <br />$3 <br />THREE WAY SWITCH <br />SEE 15/D1 <br />DIM.$ <br />DIMMER SWITCH <br />BEARING WALL - SEE NOTES <br />THIS SHEET REGARDING BOXES <br />T <br />TIMER SWITCH <br />AND FIRE -RATED WALLS <br />RECESSED CEILING EXHAUST FAN <br />C�� <br />METER CENTER <br />50 CFM MIN, 3 SONES MAX, <br />4" ROUND DUCT. SEE 15/D1 <br />o <br />ELECTRICAL PANEL <br />® <br />(-MW-� <br />MICROWAVE OVEN/RANGE HOOD <br />e8H <br />ELECTRIC BASEBOARD <br />COMBINATION, 100 CFM, 3 SONES <br />HEATER <br />SMOOTH DUCT. <br />OT <br />THERMOSTAT <br />RECESSED HEAT LAMP - <br />® <br />SMOKE DETECTOR <br />NUTONE 9410H, 250W LAMP <br />WITH BATTERY BACKUP <br />CEILING FIXTURE. SEE 12/D1 <br />CARBON MONOXIDE <br />PHOTOCELL SAFETY SENSOR <br />ALARM/SMOKE DETECTOR <br />TECH PANEL <br />AUDIBLE SPRINKLER <br />SFA <br />FLOW ALARM <br />0 <br />RECESSED CEILING WHOLE <br />HOUSE EXHAUST FAN <br />�- <br />WINDOW WITH OUTDOOR <br />WHF <br />AIR INLET <br />80 CFM MIN., 120 CFM MAX., <br />1.5 SONES, 6" ROUND DUCT <br />$Pa <br />PUSH BUTTON <br />VTR <br />VENT THROUGH ROOF <br />/ <br />1250W ELEC / <br />CEILING HEATER / <br />I <br />I <br />CFP I <br />� I <br />Master Bedroom <br />\ I <br />I TEL <br />I j <br />I j <br />I i <br />Patio <br />TV I I <br />1250W ELEC <br />I - CEILING HEATER <br />I <br />INIZ <br />' qUF <br />PwdrLiving <br />I _ i <br />J _ ` STOP <br />I / HALF <br />l------------------------------------- --! <br />I <br />I <br />M. Bath <br />j <br />! <br />,� <br />I <br />+ cl <br />I I <br />I <br />WAS+ <br />I <br />I I <br />L-- <br />1 <br />LF <br />Bath <br />\ <br />` <br />�' L +148" <br />nFj <br />VTR <br />j o <br />I ` <br />I <br />j <br />/ <br />L_J <br />VTR I <br />Lau ry j DRYE� <br />SD <br />STACK <br />THERMOSTA7� <br />T <br />& SWITCH <br />!SD <br />STACK <br />THERMOSTAT <br />j <br />I/ <br />& SWITCH <br />i TV <br />TV <br />Bedroom <br />Bedroom <br />I <br />2 <br />, <br />1000W ELEC <br />CEILING HEATER <br />750W ELEC <br />CEILING HEATER k <br />UNIT G UER LEVEL <br />UTILITY PLAN <br />7 <br />/ C <br />i <br />j Dining <br />1000W , - <br />ELEC / <br />CEILING <br />HEATER <br />\ <br />]T <br />-r- <br />I <br />/ s� <br />I I <br />I <br />I II <br />Kitche <br />j Family <br />jII I <br />I I I i i \ � <br />i I <br />\ O <br />II9DW j I <br />+44 / <br />GFa <br />TOP HALF �.� 1250W ELEC CEILING HETEL <br />FIN - - _1 <br />ATS <br />MAIN LEVEL <br />UNIT G UTILITY PLAN <br />1 /4 1 '-0" <br />-------------> <br />---------------------------- <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />TEL 750W ELEC 750W WALL <br />CEILING HEATER UNIT HEATER <br />WHI <br />' I <br />I <br />I <br />I <br />Bonus Room <br />I I <br />I � <br />I <br />_ I <br />250W LL <br />UNIT HEATER <br />I <br />\ I I <br />I I <br />I I I I <br />I I <br />I., <br />I I <br />I <br />I � <br />/ <br />I j <br />/ <br />d <br />AT <br />CEILING <br />I <br />2x8 FRAMING FOR <br />ELEC. ENTRANCE <br />TO <br />Garage <br />1 4" CLEAR INSIDE <br />ENTRY <br />AT CEILING: PREWIRE <br />JELECGARAGE <br />/ <br />LOW VOLTAGE WIRE FOR <br />\ <br />DOOR OPENER <br />\ <br />/ <br />/ <br />AND ELECTRIC EYES <br />\ <br />/ <br />/ <br />VERIFY LOCATION WITH <br />\ <br />+9'-6" <br />/ <br />/ <br />OPENER INSTALLATION <br />\ <br />A. F. F. <br />SLAB <br />I <br />I <br />0 <br />1 <br />HOSE <br />BIBB <br />I <br />I <br />TO <br />PHOTOCELL f <br />- <br />L-------------------�j <br />LEVEL <br />UNIT G UOTI I Y PLAN <br />V� <br />5052 REGISTERED <br />ARCHITECT <br />;4t� , <br />ROBERT E. WEIBLE <br />STATE OF WASHINGTON <br />to <br />o <br />d N <br />d , <br />a � <br />c <br />Z <br />co <br />Q <br />J <br />� <br />o <br />Qa N <br />0 <br />m a <br />3 � <br />c � <br />� V <br />Z oC <br />W <br />0 <br />u <br />E <br />o <br />w <br />o <br />= <br />o <br />c <br />a. <br />E <br />N <br />O <br />U <br />w <br />° <br />o <br />Z <br />.�.+ <br />LU <br />i <br />o <br />M <br />o <br />o <br />a <br />r <br />Q <br />Job No.: 13-47 <br />Sheet No.: <br />z <br />U15 <br />Sheet Order: A B U F R E 5 U I <br />