01000: GENERAL REQUIREMENTS <br />THE STRUCTURAL NOTES SUPPLEMENT THE PLANS AND SPECIFICATIONS. ANY DISCREPANCY FOUND <br />BETWEEN THE DRAWINGS, NOTES, SPECIFICATIONS, SITE CONDITIONS, AND ARCHITECTURAL PLANS <br />SHALL BE REPORTED TO THE ARCHITECT WHO SHALL CORRECT THE DISCREPANCY IN WRITING. ANY <br />WORK COMPLETED AFTER DISCOVERY OF THE DISCREPANCY SHALL BE DONE AT THE CONTRACTOR'S <br />RISK. REFER TO ARCHITECTURAL PLANS FOR OPENINGS, ARCHITECTURAL TREATMENTS, AND <br />DIMENSIONS NOT SHOWN. CONSULT MECHANICAL PLANS FOR DUCTS AND PIPES ETC. NOT SHOWN. <br />THE CONTRACTOR SHALL PROVIDE BRACING AND SUPPORT REQUIRED FOR TEMPORARY CONSTRUCTION <br />LOADS AND FOR STRUCTURAL COMPONENTS AS REQUIRED DURING ERECTION. BACKFILL BEHIND WALLS <br />SHALL NOT BE PLACED UNTIL THE WALLS ARE PROPERLY SUPPORTED. <br />THE CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATION OF ALL WORK. THE CONTRACTOR <br />SHALL BE RESPONSIBLE FOR THE COORDINATION OF THE EXCAVATION, SHORING, AND OTHER WORK <br />WITH ALL UTILITIES AND ADJACENT PROPERTIES. CALL THE UTILITY LOCATE SERVICE PRIOR TO ANY <br />WORK AT 1-800-332-2344. <br />01100: CODE REQUIREMENTS <br />ALL DESIGN AND CONSTRUCTION SHALL CONFORM TO THE 2012 INTERNATIONAL BUILDING CODE AS <br />ADOPTED BY THE CITY OF EVERETT WASHINGTON. <br />01200: DESIGN LOADS <br />LIVE LOADS <br />ROOF (SNOW) 25 PSF <br />FLOORS (RESIDENTIAL) 40 PSF <br />SNOW LOAD DESIGN DATA: <br />Pg = 20 PSF, Pf = 14 PSF, Ce = 1.0, <br />Is = 1.0, Ct = 1.0, <br />WIND DESIGN DATA: <br />BASIC WIND SPEED: <br />110 MPH (ULT.) 85 MPH (ASD) <br />WIND IMPORTANCE FACTOR: <br />Iw = 1.0 <br />WIND EXPOSURE: <br />EXPOSURE B <br />TOPOGRAPHICAL FACTOR: <br />Kzt = 1.0 <br />INTERNAL PRESSURE COEFFICIENT: <br />GCpi = +/- 0.18 <br />COMPONENT/CLADDING WIND PRESSURE: <br />P(C) = 25 PSF <br />EARTHQUAKE DESIGN DATA: <br />SEISMIC IMPORTANCE FACTOR: <br />le = 1.0 <br />SPECTRAL RESPONSE ACCELERATIONS: <br />Ss = 1.302 S1 = 0.495 <br />SITE CLASS: <br />SITE CLASS E <br />SPECTRAL RESPONSE COEFFICIENTS: <br />SDS = 0.781 SD1 = 0.792 <br />SEISMIC DESIGN CATEGORY: <br />SEISMIC DESIGN CATEGORY D <br />BASIC FORCE RESISTING SYSTEM: <br />BEARING WALL SYSTEM <br />DESIGN BASE SHEAR: <br />Cs = 0.120 W <br />RESPONSE MODIFICATION FACTOR: <br />R = 6.5 (LIGHTFRAME WALLS) <br />ANALYSIS PROCEDURE: <br />EQUIVALENT LATERAL FORCE <br />01300: GEOTECHNICAL INFORMATION <br />EARTHWORK AND FOUNDATIONS ARE TO BE CONSISTENT WITH THE GEOTECHNICAL ENGINEERING <br />RECOMMENDATIONS. ALL FOUNDATIONS ARE TO BE FOUNDED ON COMPETENT NATIVE MATERIAL OR <br />BY OTHER MEANS AS DEFINED BY A LICENSED GEOTECHNICAL ENGINEER. <br />CONVENTIONAL FOUNDATIONS HAVE BEEN DESIGNED WITH THE FOLLOWING PARAMETERS: <br />ALLOWABLE BEARING PRESSURE 250OPSF <br />ACTIVE EARTH PRESSURE (YIELDING) 35 PCF <br />ACTIVE EARTH PRESSURE (AT -REST) 55 PCF <br />PASSIVE EARTH PRESSURE 350 PCF <br />COEFFICIENT OF FRICTION 0.35 <br />SOIL PROFILE SITE CLASS E <br />ALL FOUNDATION INSTALLATIONS ARE SUBJECT TO APPROVAL OF THE LOCAL BUILDING INSPECTOR OR <br />A LICENSED GEOTECHNICAL ENGINEER. <br />01330: SHOP DRAWING SUBMITTAL PROCESS <br />SHOP DRAWINGS ARE TO BE SUBMITTED TO THE ARCHITECT AN ENGINEER OF RECORD FOR APPROVAL <br />PRIOR TO FABRICATION. IF SHOP DRAWINGS DIFFER FROM THE APPROVED DESIGN DRAWINGS, NEW <br />DESIGN DRAWINGS BEARING THE SEAL AND SIGNATURE OF A LICENSED STATE OF WASHINGTON <br />STRUCTURAL ENGINEER SHALL BE SUBMITTED ALONG WITH THE SHOP DRAWINGS TO THE BUILDING <br />OFFICIAL FOR APPROVAL PRIOR TO FABRICATION. <br />SHOP DRAWINGS ARE REQUIRED FOR FOR PREFABRICATED WOOD TRUSSES. <br />CALCULATIONS BEARING THE SEAL AND SIGNATURE OF A LICENSED STATE OF WASHINGTON <br />STRUCTURAL ENGINEER SHALL BE SUBMITTED ALONG WITH THE SHOP DRAWINGS FOR PREFABRICATED <br />PLATED WOOD TRUSSES. <br />01400: INSPECTIONS AND SPECIAL INSPECTIONS <br />THE CONTRACTOR SHALL BE RESPONSIBLE TO COORDINATE ALL INSPECTIONS REQUIRED BY THE <br />LOCAL BUILDING DEPARTMENT. <br />SPECIAL INSPECTIONS ARE NOT REQUIRED UNLESS OTHERWISE REQUIRED BY THE BUILDING OFFICIAL. <br />01401: STRUCTURAL OBSERVATION <br />STRUCTURAL OBSERVATION IS NOT REQUIRED. <br />02000: SITE CONSTRUCTION <br />ALL SITE CONSTRUCTION SHALL BE CONSISTENT WITH THE GEOTECHNICAL ENGINEERING <br />RECOMMENDATIONS AS NOTED IN THE GEOTECHNICAL ENGINEERING REPORT (SEE SECTION 01300) AND <br />IN SUBSEQUENT DIRECTIVES. <br />02260: EXCAVATION SUPPORT AND PROTECTION <br />EXCAVATION FOR FOUNDATIONS SHALL BE PER PLAN DOWN TO UNDISTURBED NATIVE MATERIAL PER <br />THE GEOTECHNICAL ENGINEERING RECOMMENDATIONS, OVER -EXCAVATED AREAS SHALL BE <br />BACKFILLED WITH LEAN CONCRETE OR PER GEOTECHNICAL RECOMMENDATIONS AT THE CONTRACTOR'S <br />EXPENSE. <br />EXCAVATION SLOPES SHALL BE SAFE AND SHALL NOT BE GREATER THAN THE LIMITS SPECIFIED BY <br />LOCAL, STATE, AND NATIONAL SAFETY REGULATIONS. <br />INSTALLATION OF CONSTRUCTION SHORING, IF REQUIRED, SHALL BE PER THE SHORING DRAWINGS, <br />NOTES, AND SPECIFICATIONS. <br />02300: BACKFILL AND COMPACTION <br />BACKFILL SHALL NOT BE PLACED UNTIL THE REMOVAL OF FORMWORK AND OF ANY DEBRIS. BACKFILL <br />BEHIND ALL WALLS SHALL NOT BE PLACED UNTIL THE WALLS ARE PROPERLY SUPPORTED. ALL <br />BACKFILL MATERIAL AND PLACEMENT PROCEDURES SHALL BE CONSISTENT WITH THE GEOTECHNICAL <br />ENGINEERING RECOMMENDATIONS. <br />STRUCTURAL NOTES <br />03000: CONCRETE <br />CONCRETE CONSTRUCTION SHALL CONFORM TO THE AMERICAN CONCRETE INSTITUTE STANDARD ACI <br />318-11 "BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE". <br />CEMENT AND CONCRETE SHALL CONFORM TO IBC SECTION 1903. ADMIXTURES SHALL BE APPROVED <br />BY THE ENGINEER OF RECORD AND SHALL COMPLY WITH ACI 318-11 SECTION 3.6. CONCRETE <br />EXPOSED TO FREEZING AND THAWING SHALL HAVE AN AIR ENTRAINING ADMIXTURE CONFORMING TO <br />IBC SECTION 1904.2. THE USE OF WATER SOLUBLE CHLORIDE ION SHALL NOT BE USED. <br />THE CONTRACTOR SHALL SUBMIT MIX DESIGNS TO ENGINEER OF RECORD FOR APPROVAL FOUR WEEKS <br />PRIOR TO PLACING CONCRETE. MIX DESIGNS SHALL BE REVIEWED FOR CONFORMANCE TO IBC <br />SECTIONS 1904 AND 1905. <br />CONCRETE MIX DESIGNS SHALL MEET THE FOLLOWING REQUIREMENTS: <br />28 DAY MAX. MAX. AIR SPECIAL LOCATION <br />STRENGTH W/C SLUMP ENTRAINMENT INSPECTION AND <br />f'c (PSI) RATIO (INCHES) (PERCENT) REQUIRED APPLICATION <br />2500 0.45 4±10±1 NO FOOTINGS <br />3000 0.45 4±1 5±1 NO FOUNDATION AND STEM WALLS <br />3000 0.45 4±1 5±1 NO EXTERIOR SLAB ON GRADE, <br />DRIVEWAYS, CURBS, WALKWAYS, PATIOS, PORCHES, STEPS EXPOSED TO <br />WEATHER, AND GARAGE FLOORS. <br />2500 0.50 5±1 Oft NO ALL OTHER CONCRETE <br />ONE COMPRESSION TEST MINIMUM SHALL BE COMPILED FOR EVERY 150 CUBIC YARDS OR 5000 <br />SQUARE FEET OF SURFACE AREA FOR EACH MIX DESIGN PLACED EACH DAY. A TEST SHALL BE THE <br />AVERAGE STRENGTH OF TWO CYLINDERS MADE FROM THE SAME SAMPLE AND TESTED AT THE <br />SPECIFIED AGE. ADDITIONAL CYLINDERS MAY BE MADE FOR INFORMATION REGARDING POST <br />ACCEPTABLE IF: <br />1. NO TEST FALLS 500 PSI BELOW THE SPECIFIED STRENGTH <br />2. THE AVERAGE OF ALL SETS OF 3 CONSECUTIVE TESTS DOES NOT FALL <br />BELOW THE SPECIFIED STRENGTH. <br />CONCRETE NOT MEETING THE ABOVE CRITERIA SHALL BE SUBJECT TO FURTHER TESTING AT NO <br />ADDITIONAL EXPENSE TO THE OWNER. <br />RESHORING, WHERE REQUIRED, SHALL CONFORM TO ACI 301 SECTION 4.6. SUBMIT PROPOSED <br />RESHORING PLANS TO THE ENGINEER OF RECORD FOR REVIEW. <br />CHAMFER ALL EXPOSED CORNERS PER THE ARCHITECTURAL PLANS OR 3/4 INCH IF NOT SPECIFIED <br />BY THE ARCHITECT. <br />03100: REINFORCING STEEL <br />REINFORCING STEEL DETAILING, FABRICATION, AND PLACEMENT SHALL BE PER ACI 318-11. <br />REINFORCING STEEL SHALL MEET THE FOLLOWING REQUIREMENTS: <br />ASTM A-615 DEFORMED BARS GRADE 40 (fy=40 KSI) FOR #3 BARS ONLY <br />ASTM A-615 DEFORMED BARS GRADE 60 (fy=60 KSI) FOR #4 BARS AND LARGER <br />ASTM A-706 DEFORMED BARS GRADE 60 (fy=60 KSI) FOR ALL WELDABLE BARS <br />ASTM A-185 SMOOTH BAR (fy=60 KSI) FOR WELDED WIRE FABRIC <br />REINFORCING FOR SLABS ON GRADE SHALL BE 6X6 W1.4XW1.4 WELDED WIRE FABRIC OR FIBER MESH <br />UNLESS NOTED OTHERWISE. PROVIDE LAP SPLICES PER THE LAP SPLICE SCHEDULE ON SHEET S6.0. <br />REINFORCING STEEL AT ALL WALLS, SLABS, AND FOOTINGS SHALL BE CONTINUOUS AROUND CORNERS <br />ELSE CORNER BARS SHALL BE PROVIDED. <br />COVER REQUIREMENTS SHALL BE AS FOLLOWS UNLESS NOTED OTHERWISE: <br />CONCRETE CAST AGAINST EARTH <br />ALL BAR SIZES .............. 3" <br />FORMED SURFACE EXPOSED TO EARTH OR WEATHER <br />#6 AND LARGER .............. 2" <br />#5 AND SMALLER ............. 1 1/2" <br />CONCRETE NOT EXPOSED TO EARTH OR WEATHER <br />WALLS AND JOISTS <br />#11 BARS AND SMALLER ......... 3/4" <br />SLABS AND JOISTS <br />#11 BARS AND SMALLER ........ 1" <br />BEAMS, COLUMNS <br />PRIMARY REINFORCEMENT ....... 1 1/2" <br />TIES, STIRRUPS, AND SPIRALS .... 1 1/2" <br />REINFORCING STEEL SHALL BE ACCURATELY PLACED AND ADEQUATELY SECURED IN PLACE PRIOR TO <br />CONCRETE PLACEMENT. REINFORCING STEEL SHALL NOT BE FIELD BENT EXCEPT AS NOTED IN THE <br />DESIGN DRAWINGS. WELDING OF REINFORCING STEEL SHALL NOT BE PERMITTED WITHOUT PRIOR <br />APPROVAL OF THE ENGINEER OF RECORD EXCEPT AS NOTED ON THE DESIGN DRAWINGS. <br />06071: PRESERVATIVE TREATED WOOD PRODUCTS <br />PRESERVATIVE TREATED WOOD SHALL BE REQUIRED FOR ALL WOOD THAT FORMS THE STRUCTURAL <br />SUPPORT OF THE BUILDING, BALCONIES PORCHES, OR SIMILAR PERMANENT BUILDING APPURTUNENCES <br />THAT ARE EXPOSED TO THE WEATHER WITHOUT ADEQUATE PROTECTION FROM A ROOF, EAVE, <br />OVERHANG OR OTHER COVERING TO PREVENT MOISTURE OR WATER ACCUMULATION AT THE SURFACE <br />OR AT JOINTS BETWEEN MEMBERS. <br />ALL WOOD INSTALLED ABOVE GROUND AND RESTING ON AN EXTERIOR CONCRETE OR MASONRY <br />FOUNDATION WALL LESS THAN 8 INCHES FROM EXPOSED EARTH. <br />POSTS OR COLUMNS SUPPORTING PERMANENT STRUCTURES AND SUPPORTED BY A CONCRETE SLAB <br />OR FOOTING THAT IS IN DIRECT CONTACT WITH THE EARTH. EXCEPT; <br />1. IF LOCATED IN BASEMENTS ON A CONCRETE PIER OR METAL PEDESTAL 1 INCH ABOVE THE <br />SLAB AND SEPARATED THEREFROM BY AN IMPERVIOUS MOISTURE BARRIER. <br />2. IF IN AN ENCLOSED CRAWL SPACE OR AN UNEXCAVATED AREA WITHIN THE BUILDING <br />PERIPHERY AND SUPPORTED BY A CONCRETE PIER OR PEDESTAL MORE THAN 8 INCHES FROM <br />EXPOSED GROUND AND SEPARATED THEREFROM BY AN IMPERVIOUS MOISTURE BARRIER. <br />3. SLEEPERS AND SILLS ON A CONCRETE SLAB ON GRADE THAT DOES NOT HAVE AN IMPERVIOUS <br />MOISTURE BARRIER SEPARATION WITH EXPOSED EARTH. <br />4, LEDGERS AND FURRING ATTACHED DIRECTLY TO THE INTERIOR OF EXTERIOR CONCRETE OR <br />MASONRY WALLS BELOW GRADE. <br />PRESERVATIVE TREATMENT SHALL BE PER AMERICAN WOOD PRESERVERS' ASSOCIATION (AWPA) <br />SPECIFICATION C2 AND C9 OR APPLICABLE STANDARDS. <br />ALL FASTENERS (NAILS, BOLTS, ANCHOR BOLTS, PLATES, HANGERS, ETC.) IN CONTACT WITH TREATED <br />LUMBER SHALL BE CORROSION RESISTANT G-185 HOT DIPPED GALVANIZED PER ASTM A153 OR <br />STAINLESS STEEL. <br />06100: ROUGH FRAMING <br />SAWN LUMBER SHALL CONFORM TO WEST COAST LUMBER INSPECTION BUREAU (WCLIB) "GRADING AND <br />DRESSING RULES" NO. 17 LATEST EDITION. SAWN LUMBER SHALL BE S4S AND SURFACED DRIED, 19 <br />PERCENT MAXIMUM MOISTURE CONTENT. PROTECT LUMBER FROM WEATHER AND PROVIDE FURTHER <br />DRYING OF ASSEMBLED FRAMING TO MINIMIZE WOOD SHRINKAGE POTENTIAL. ALL LUMBER EXPOSED <br />TO WEATHER OR IN CONTACT WITH CONCRETE OR MASONRY SHALL BE PRESERVATIVE TREATED U.N.O. <br />PER PLAN. LUMBER SPECIES, GRADE, AND PROPERTIES FOR EACH USE/LOCATION SHALL BE AS <br />FOLLOWS U.N.O. PER PLAN/SCHEDULE: <br />Fb Fv Fcp Fc E <br />USE/LOCATION SPECIES GRADE (PSI) (PSI) (PSI) (PSI) (PSI) <br />WALL STUDS/BLOCKING <br />2X, 3X HEM -FIR STUD 675 150 405 800 1.2E6 <br />4" WIDE <br />2X, 3X HEM -FIR NO. 2 850 150 405 1300 1.3E6 <br />6" & WIDER <br />WALL PLATES <br />2X4, 3X4 HEM -FIR STUD 675 150 405 800 1.2E6 <br />2X6, 3X6 HEM -FIR NO. 2 850 150 405 1300 1.3E6 <br />JOISTS <br />2X, 3X HEM -FIR NO. 2 850 150 405 1300 1.3E6 <br />LEDGERS <br />2X, 3X DOUGLAS FIR -LARCH NO. 2 900 180 625 1350 1.6E6 <br />4X DOUGLAS FIR -LARCH NO. 1 1000 180 625 1500 1.7E6 <br />BEAMS AND POSTS <br />4X DOUGLAS FIR -LARCH N0, 2 900 180 625 1350 1.6E6 <br />6X DOUGLAS FIR -LARCH NO, 1 1200 170 625 1000 1.6E6 <br />06101: STRUCTURAL FINGER JOINTED LUMBER <br />STRUCTURAL FINGER JOINTED LUMBER SHALL BE PERMITTED TO BE USED INTERCHANGEABLY WITH <br />SAWN LUMBER MEMBERS OF THE SAME SPECIES AND GRADE. STRUCTURAL FINGER JOINTED LUMBER <br />SHALL BE GRADED UNDER AMERICAN LUMBER STANDARD COMMITTEE "PRODUCT STANDARD PS <br />20-99". LUMBER CLASSIFIED AS STUD USE ONLY SHALL BE LIMITED TO VERTICAL APPLICATIONS <br />ONLY. LUMBER WITH CERTIFIED EXTERIOR JOINTS IS NOT RESTRICTED TO ANY TYPE OF LOADING. <br />06102: FRAMING NOTES <br />FRAMING CONNECTORS, ACCESSORIES, AND FASTENERS AS NOTED IN THE PLANS AND DETAILS SHALL <br />BE AS MANUFACTURED BY SIMPSON STRONG -TIE. EQUIVALENT HARDWARE MAY BE USED WITH PRIOR <br />APPROVAL BY ENGINEER OF RECORD. INSTALL ALL HARDWARE PER MANUFACTURERS' SPECIFICATIONS. <br />WHERE STRAPS CONNECT TWO MEMBERS TOGETHER, PLACE HALF OF THE REQUIRED FASTENERS INTO <br />EACH MEMBER. PROVIDE SOLID BLOCKING AT ALL BEARING POINTS. SEE SECTION 06071 FOR <br />FASTENER REQUIREMENTS AT TREATED LUMBER. TYPICAL NAILING NOT SHOWN PER PLAN, DETAIL, OR <br />SCHEDULE SHALL CONFORM TO FASTENING SCHEDULE PER IBC TABLE 2304.9.1 OR TO THE FASTENING <br />SCHEDULE ON SHEET S1.0. <br />NAILS SHALL BE COMMON UNLESS NOTED OTHERWISE COMMON NAIL DIMENSIONS ARE AS FOLLOWS: <br />NAIL SIZE DIAMETER LENGTH <br />8d 0.131" 2.5" <br />10d 0.148" 3.0" <br />12d 0.148" 3.25" <br />16d 0.162" 3.5" <br />UNLESS NOTED OTHERWISE PER SHEARWALL SCHEDULE OR PLANS, ANCHOR BOLTS AT SILL PLATES <br />SHALL BE 5/8" DIAMETER WITH 7" MINIMUM EMBEDMENT INTO CONCRETE AND SHALL BE SPACED NOT <br />MORE THAN 4 FEET APART. THERE SHALL BE A MINIMUM OF TWO BOLTS PER SILL PIECE WITH ONE <br />BOLT LOCATED NOT MORE THAN 12" NOR LESS THAN 4.5" FROM EACH END OF THE PIECE. A <br />3"X3"XO.229" PLATE WASHER SHALL BE PROVIDED FOR ALL ANCHOR BOLTS (DO NOT COUNTER -SINK <br />PLATE WASHERS). A 13/16" X 1 3/4" DIAGONAL SLOTTED HOLE IN THE 3" X 3" PLATE WASHER IS <br />ALLOWED WITH A STANDARD CUT WASHER. <br />06103: JOIST AND BEAM HANGERS <br />JOIST AND BEAM HANGERS AS NOTED IN THE PLANS SHALL BE AS MANUFACTURED BY SIMPSON <br />STRONG -TIE. EQUIVALENT HARDWARE MAY BE USED WITH PRIOR APPROVAL BY ENGINEER OF RECORD. <br />JOIST AND BEAM HANGERS SHALL BE INSTALLED PER MANUFACTURERS' SPECIFICATIONS AND SHALL <br />BE AS FOLLOWS UNLESS NOTED OTHERWISE PER PLANS OR DETAILS: <br />MEMBER SIZE <br />HANGER <br />SAWN LUMBER <br />"U" SERIES TO MATCH LUMBER SIZE <br />3.125" WIDE GLULAM BEAM <br />HGUS3.25/10 <br />5.125" WIDE GLULAM BEAM <br />HGUS5.25/10 <br />6.75" WIDE GLULAM BEAM <br />HGUS6.88/10 <br />8.75" WIDE GLULAM BEAM <br />HGU9.00-SDS <br />MANUFACTURED WOOD "I" JOIST <br />"IUS" SERIES TO MATCH "I" JOIST SIZE <br />1.75" WIDE PSL OR LVL BEAM <br />"LBV" SERIES TO MATCH DEPTH <br />2.69" WIDE PSL BEAM <br />"LBV" SERIES TO MATCH DEPTH <br />3.5" WIDE PSL OR LVL BEAM <br />"GLTV" SERIES TO MATCH DEPTH <br />5.25" WIDE PSL OR LVL BEAM <br />"GLTV" SERIES TO MATCH DEPTH <br />7" WIDE PSL BEAM <br />"HGLTV" SERIES TO MATCH DEPTH <br />06104: SHRINKAGE OF WOOD FRAMING <br />SHRINKAGE IN WOOD FRAMING IS DUE TO LOSS OF MOISTURE CONTENT AND TO COMPRESSION OF <br />ASSEMBLIES OF WOOD COMPONENTS. PLUMBING, ELECTRICAL, AND MECHANICAL SYSTEMS AS WELL <br />AS EXTERIOR FINISHES SHALL BE DESIGNED AND BUILT TO ACCOMMODATE 1/4 INCH PER FLOOR <br />WOOD SHRINKAGE. THE USE OF KILN DRIED LUMBER AND PROVIDING A DRYING PROCESS TO THE <br />FRAMING MEMBERS PRIOR TO APPLICATION OF FINISHES WILL HELP CONTROL BUT WILL NOT ELIMINATE <br />SHRINKAGE. <br />06160: WOOD SHEATHING <br />STRUCTURAL WOOD SHEATHING PANELS SHALL HAVE APA GRADE TRADEMARK OF THE AMERICAN <br />PLYWOOD ASSOCIATION. WOOD SHEATHING PANELS SHALL BE C-D INT APA WITH EXTERIOR GLUE <br />(CDX). ORIENTED STRAND BOARD (OSB) PANELS SHALL BE EXPOSURE 1. PANELS SHALL HAVE THE <br />FOLLOWING THICKNESS, SPAN RATING, AND FASTENING UNLESS NOTED OTHERWISE PER PLAN: <br />EDGE FIELD <br />NAILS NAILS <br />ROOF: 7/16" 40/20 APA RATED OSB 8d AT 6" 8d AT 12" <br />FLOOR: 3/4" APA RATED STURD-I-FLOOR OSB 40/20 T&G 10d AT 6" 10d AT 12" <br />SHEARWALL: 7/16" APA RATED 24/16 EXPOSURE 1 OSB SEE SCHEDULE SHEET S1.1 <br />ALL ROOF AND FLOOR SHEATHING PANELS SHALL BE INSTALLED FACE GRAIN PERPENDICULAR TO <br />SUPPORTS AND IN A STAGGERED PATTERN UNLESS NOTED OTHERWISE PER PLAN, BLOCKING AT <br />INTERMEDIATE FLOOR AND ROOF SHEATHING JOINTS SHALL NOT BE REQUIRED UNLESS NOTED <br />OTHERWISE PER PLAN. SHEARWALL SHEATHING SHALL BE BLOCKED AT ALL EDGES WITH 2X OR 3X <br />FRAMING PER SHEARWALL SCHEDULE <br />06176: METAL PLATE CONNECTED WOOD TRUSSES <br />PREMANUFACTURED PLATED WOOD TRUSSES SHALL BE MANUFACTURER DESIGNED AND SHALL COMPLY <br />WITH THE TRUSS PLATE INSTITUTE (ANSI/TPI 1-2002, NATIONAL DESIGN STANDARD FOR METAL PLATE <br />CONNECTED WOOD TRUSS CONSTRUCTION) AND OSSC SECTION 2303.4. SHOP DRAWINGS AND <br />CALCULATIONS SHALL BE SUBMITTED PER THE REQUIREMENTS OF SECTION 01330. DESIGN FOR THE <br />SPANS AND CONDITIONS SHOWN ON THE PLANS, LOADS PER SECTION 01200, AND THE FOLLOWING: <br />ROOF FLOOR <br />TOP CHORD LIVE LOAD SEE SECTION 01200 SEE SECTION 01200 <br />TOP CHORD DEAD LOAD 10 PSF 10 PSF <br />TOP CHORD DRAG LOAD SEE PLAN SEE PLAN <br />TOP CHORD NET WIND UPLIFT 7 PSF (NET) N/A <br />BOTTOM CHORD DEAD LOAD 5 PSF 5 PSF <br />HVAC SEE MECHANICAL SEE MECHANICAL <br />LIVE LOAD DEFLECTION L/360 L/360 <br />06185: STRUCTURAL GLUED LAMINATED TIMBER <br />GLUED -LAMINATED MEMBERS SHALL HAVE AMERICAN INSTITUTE OF TIMBER CONSTRUCTION (AITC) <br />IDENTIFICATION MARK. EXPOSED MEMBERS SHALL RECEIVE ONE COAT OF END SEALER APPLIED <br />IMMEDIATELY AFTER TRIMMING IN EITHER SHOP OR FIELD. SHOP DRAWINGS SHALL BE SUBMITTED PER <br />THE REQUIREMENTS OF SECTION 01330. DESIGN MATERIAL PROPERTIES SHALL BE AS FOLLOWS: <br />USE COMBINATION SYMBOL SPECIES CAMBER <br />SIMPLE SPAN BEAM 24F-V4 DF/DF STANDARD <br />CONTINUOUS BEAM 24F-V8 DF/DF ZERO <br />CANTILEVER BEAM 24F-V8 DF/DF ZERO <br />UNEXPOSED GLUED -LAMINATED TIMBER SHALL BE INDUSTRIAL GRADE. TYPICAL, UNLESS NOTED <br />OTHERWISE. EXPOSED GLUED LAMINATED TIMBER SHALL BE APPEARANCE CLASS PER ARCHITECT. <br />06190: MANUFACTURED WOOD BEAMS <br />MANUFACTURED/ENGINEERED WOOD BEAMS SHALL BE THE SIZE AND TYPE SHOWN ON THE DRAWINGS <br />AS MANUFACTURED BY TRUS-JOIST OR APPROVED EQUAL. STORAGE, ERECTION, AND INSTALLATION <br />SHALL BE PER MANUFACTURER SPECIFICATIONS. MICROLAM AND PARALLAM MEMBERS SHALL NOT <br />HAVE NOTCHES OR DRILLED HOLES WITHOUT PRIOR ENGINEER OF RECORD APPROVAL. SHOP DRAWINGS <br />SHALL BE SUBMITTED PER THE REQUIREMENTS OF SECTION 01330. DESIGN MATERIAL PROPERTIES <br />SHALL BE AS FOLLOWS: <br />MEMBER E (PSI) Fb (PSI) Fcp (PSI) Fv (PSI) <br />LVL = MICROLAM 1.9 E6 2600 750 285 <br />PSL = PARALLAM 2.0 E6 2900 650 290 <br />LSL = 1.75" TIMBERSTAND 1.55 E6 2250 750 400 <br />LSL RIM = 1.5" TIMBERSTAND RIM BOARD <br />STRUCTURAL DRAWING SHEET <br />INDEX <br />SHEET <br />DESCRIPTION <br />DATE <br />S1.0 <br />STRUCTURAL NOTES <br />01/21/16 <br />S1.1 <br />STRUCTURAL NOTES AND SCHEDULES <br />01/21/16 <br />S1.2 <br />SHEARWALL SCHEDULE AND DETAILS <br />01/21/16 <br />S1.3 <br />HOLDOWN SCHEDULE AND DETAILS <br />01/21/16 <br />S1.4 <br />SWSB DETAILS <br />01 /21 /16 <br />S6.0 <br />TYPICAL CONCRETE DETAILS <br />01/21/16 <br />S9.0 <br />TYPICAL FLOOR FRAMING DETAILS <br />01/21/16 <br />S9.1 <br />TYPICAL ROOF FRAMING DETAILS <br />01/21/16 <br />S9.2 <br />FRAMING DETAILS <br />01/21/16 <br />S9.3 <br />FRAMING DETAILS - UNIT ETC & E1D <br />01 /21 /16 <br />S9.4 <br />FRAMING DETAILS - UNIT ElB, D, F & E3 <br />01/21/16 <br />S9.5 <br />FRAMING DETAILS - UNIT E & E3 <br />01/21/16 <br />S9.6 <br />FRAMING DETAILS - UNIT G & F <br />01/21/16 <br />0 <br />cc <br />w <br />Q) <br />U <br />Z <br />- Q) <br />U w <br />00 <br />o <br />� o <br />0 <br />cc <br />N ul co <br />o <br />Q) <br />Q) <br />W <br />C) o <br />4 <br />U Lo <br />U co <br />z CQ <br />o Q0 <br />+ cc o <br />cn ­� C\2 <br />U <br />(] <br />N <br />o <br />Mi <br />cc) <br />CN <br />w <br />o <br />00 <br />N <br />L(j <br />- <br />4t <br />� <br />O <br />0 <br />O <br />0 <br />O <br />a <br />t- <br />C1 <br />m <br />cn <br />v <br />F <br />V) <br />w <br />w <br />F- <br />� <br />w <br />n� <br />F� <br />>o <br />Q> Q <br />o <br />�--' <br />a3 <br />ct <br />U I-, + <br />c/D 4 W <br />