Laserfiche WebLink
METAL RAKE <br />FLASHING <br />w 1 X3 TRIM <br />j 2X8 TRIM c <br />SIDING� � <br />i <br />COMP. ROOFING --�' <br />(2) LAYERS 5/8" TYPE 'X' GYP. <br />SHTG.OVER GABLE TRUSS, EA. <br />SIDE SEE 17/03 FOR 2—HOUR <br />TEST ASSEMBLY DETAILS <br />( ♦ ♦ 1AL11 ..SR <br />fill <br />— <br />NO OPENINGS WITHIN 4'-0" <br />0 NO OPENINGS WITHIN 4'-0" <br />OF PROPERTY LINE EITHER SIDE <br />OF PROPERTY LINE EITHER SIDE <br />ROOF SHTG. <br />CENTER COMMON WALL <br />OVER PROPERTY LINE---� <br />ROOF SHEATHING <br />-GABLE TRUSS <br />(2) LAYERS Va" <br />FIRE —RETARDANT <br />EXTERIOR WALL SHEATHING <br />TYPE 'X' GWB <br />X <br />TREATED PLYWOOD <br />X I <br />4'-0' EITHER SIDE <br />STEP FLASHING <br />CONT. DRAG TRUSS <br />OF Il?. <br />END TRUSS WITH <br />VERTICALS AT <br />TYPICAL FLOOR <br />�I <br />0 <br />. • (III <br />• �ijl ��Ilil • <br />BATT INSUL. <br />'Ii ►-�Ilii <br />WIN <br />IN <br />r i <br />�� <br />��I��I <br />i I � • <br />NW-3010111AI'Ml MIA <br />• M• <br />. <br />T' <br />FIRE—SAFING INSUL........ <br />t0 4 �0 AS FIREBLOCK, TYP 2 4 E2t4 <br />2 4 INSULATE 2 4 z 4FLOOR <br />INSULATE FLOOR 2 4 8 OVER UNHEATED <br />OVER UNHEATED D1 TYP. COMMON WALL V8" TYPE 'X' GWB SPACE <br />SPACE 1 FIREBLOCKING , <br />NO INSUL. AT GARAGE-] <br />1 <br />NON —BEARING BEARING <br />SITUATION SITUATION <br />COMMON WALL AT STEPPED FLOOR <br />18 14 COMMON WALL AT FLOOR <br />1-1/2" = 1'-O" SECTION 1-1/2" = 1'-0" SECTION <br />EXTEROR WALL <br />INTERIOR <br />WALL —TO —ROOF <br />— FLASHING <br />12 <br />riz%� PER ROOFING OVER <br />PLAN r—ROOF SHEATHING <br />2x BLOCKI <br />2 <br />TRUSS HANGER IPORCH ROOF <br />MONO TRUSSES <br />AT 24" O.C. <br />5/4x3 TRIM <br />5 <br />s40 <br />D1 <br />I <br />FIBER —CEMENT SOFFIT <br />INTERIOR <br />I <br />WITH STRIP VENTING <br />1 <br />I <br />1x3 TRIM AT PERIMETER <br />D1 <br />OF PORCH CEILING <br />2x10 TRIM AT <br />PERIMETER OF PORCH <br />19 LOW ROOF AT ENTRY <br />SECTION <br />Fr'WALL—TO—ROOF <br />EXTEROR WALL <br />1 <br />FLASHING <br />D1 <br />ROOFING OVER <br />ROOF SHEATHING <br />12 <br />PER PLAN <br />INTERIOR 2x BLKG. <br />PORCH ROOF <br />MONO TRUSSES <br />s AT 24" O.C. <br />2 BEAM PER STRUC. <br />-----------TRUSS HANGER <br />s 5 4x3 TRIM <br />PER PLAN <br />FIBER —CEMENT SOFFIT PORCH <br />I —SIDING 1x3 TRIM AT 2x1O TRIM AT <br />III OVER EXTR. PERIMETER OF PERIMETER OF <br />WALL SHTG. PORCH CEILING PORCH <br />20 <br />LOW ROOF AT CANTILEVER <br />1" = 1'-0" SECTION <br />2x4 BLOCK BEHIND <br />TUB NAILING FLANGE <br />CONT. V8" TYPE 'X' GWB <br />PRE —INSTALL %" TYPE 'X' GWB <br />BEHIND TUB/SHOWER. <br />EXTERIOR GRADE PLYWD. BEHIND <br />TUB/SHOWER UP 70" MINIMUM <br />ABOVE THE DRAIN INLET <br />APPROVED <br />FIRESTOPPING <br />t----f—MATERIAL <br />COMPOSITION SHINGLES <br />OVER ROOF SHEATHING <br />2x4 VENT BLOCK <br />USE SOLID BLOCKING <br />AISE EL WITHIN 5'-0" OF II? <br />RUSSES A <br />4" O.C. 12 SEE ROOF PLANS <br />,",,,—SEE <br />SLOPE <br />I <br />SOLID 2x METAL <br />L T U S / FLASHING <br />�0< <br />Ld U-- <br />4, <br />SEE ROOF PLANS <br />v`'i � <br />FOR GUTTER <br />Q <br />LOCATIONS <br />C 1 TIT ' 2X8 FASCIA <br />2 6 <br />SIDING OVER <br />D1 I SHEATHING <br />VARIES SEE <br />ROOF PLANS <br />SEE S SHEETS FOR <br />I 1 TRUSS BLOCKING <br />I D1 CONNECTION <br />9 OVERHANG W/ RAISED HEEL <br />1-1/2" = 1'-O" SECTION <br />INSULAT <br />OVER UI <br />DLID RIM BOARD BLOCKING <br />NO INSUL. AT GARAGE <br />10 COMMON WALL AT FLOOR <br />1-1/2" = 1'-O" SECTION <br />STAIR STRINGS <br />BEYON <br />Ye" GAP BETWEEP <br />STRINGER AND GWE <br />STRINGER OF NO i <br />LESS THE (2) 2x JOIST; <br />4" NOMINAL THICKNESS <br />CENTER WALL OVER <br />COMMON PROPERTY LINE <br />I <br />COMPOSITION SHINGLES OVER #15 <br />FELT OVER ROOF SHEATHING <br />INSULATION BAFFLE SHALL EXTEND 6" VERTICALLY <br />ABOVE SURFACE OF BATT. INSULATION, OR 12" <br />ABOVE SURFACE OF BLOWN IN INSULATION. <br />SEE ROOF PLAN FOR SLOPE <br />12 VENT BLOCK WITH (3) <br />'IV2" 0 SCREENED VENTS. <br />�' USE SOLID BLOCKING <br />WHEN WALL IS WITHIN <br />A D Z 5'-0" OF R <br />J UL TI N ; <br />METAL <br />EAVE <br />2 s FLASHING <br />OOF PLAN <br />UTTER <br />ION <br />5 TYPICAL EAVE <br />1-1/2" = l'-O" SECTION <br />TYPICAL 1 ` <br />UNIT EXTERIOR <br />WALL D1 LAP OUTER LAYER <br />OF BUILDING PAPER <br />(2) LAYERS 5/8" TYPE 'X' GWB 6 ; OVER FLASHING. <br />ADDED AT RATED FLOOR D1 1, INNER LAYER RUNS <br />CONDITIONS (SEE BLDG. BEHIND SIDING <br />PLANS FOR LOCATIONS) 2 s AND FURR STRIPS <br />BELLY BAND f3 <br />2 2 2 1 FLASHING D3 <br />T E M L <br />N J <br />BELLY <br />BAND <br />p� I 2x6 TRIM <br />t <br />TYP. <br />FLOOR/CEILING <br />FIBER CEMENT <br />EXTERIOR <br />I SOFFIT BOARD <br />UNIT i VARIES <br />REMOVE INSULATION 1 <br />AT UNHEATED SPACE D1 <br />PROJECTING FLOOR <br />6 <br />1-1/2" = 1'-O" SECTION <br />EXTERIOR Ip D1 <br />UNIT <br />TYPICAL <br />EXTERIOR <br />NO PLUMBING IN D1 <br />WALL U.N.O. <br />8" COMMON WAL — <br />fP <br />15 TUB/SHOWER AT COMMON WALL STAIR STRINGER AT COMMON WALL COMMON WALL AT EXTERIOR WALL <br />11 <br />1" = 1> -o» 7 SECTION 1-1/2" = 1'-O" SECTION 1-1/2" = 1'-O" PLAN <br />[tMETAL <br />PIPE <br />Z <br />CENTER COMMON WALL <br />OVER PROPERTY LINE <br />A" II' A" <br />TYP. IN <br />E <br />UN! T <br />p <br />4" 4" <br />UNIT <br />4 2—HR. COMMON <br />;PACE D1 WALL ASSEMBLY <br />1" CLEAR , <br />AIRSPACE z _` 7 _' <br />16 COMMON WALL 0 INTERIOR WALLS <br />1-1/2" = 1'-0" PLAN <br />I 1 <br />UNIT I D1 <br />12 I EXTERIOR <br />TYP. <br />EXTERIOR <br />Q <br />WALL <br />J <br />CL <br />SIDING OVER (1) LAYER <br />I TYPE 'X' GYP. SHEATHING <br />OVER WOOD SHEATHING <br />z s z s z z <br />CENTER WALL OVER <br />COMMON PROPERTY LINE <br />7---------------- FI' <br />12 <br />2-HR COMM. WALL AT BLDG. JOG <br />1" = 1'-o" PLAN <br />COMPOSITION ROOFING <br />OVER ROOF SHEATHING <br />M TL. RAKE <br />FLASHING <br />2x OUTRIGGERS <br />I 2x2 �--_P�:Ix3 TRIM <br />AT 24" O.C. <br />EXTEND BACK TO <br />i <br />2x8 FASCIA <br />NEXT TRUSS <br />LET —IN OR HOLD <br />VARIES SEE DOWN TOP CHORD <br />ROOF PLANS OF GABLE TRUSS <br />GABLE END FOR OUTRIGGERS <br />I <br />I TRUSS <br />I <br />I <br />j TOP PLATE <br />j <br />17 TYP. ROOF/CLG. 2 s <br />D1 ASSEMBLY <br />I EXTERIOR <br />I <br />UNIT <br />I 1 <br />TYP. EXTERIOR WALL <br />I D1 <br />I <br />I <br />EXTERIOR WALL <br />1 <br />AT ROOF <br />1 <br />1-1/2" = 1'-0" SECTION <br />I <br />I <br />TYP. EXTERIOR WALL <br />TYP. FLOOR/CLG. <br />I 1 <br />CONSTRUCTION <br />I D1 <br />5 <br />I <br />I <br />D1 <br />1 <br />i <br />s <br />I FIN. FLOOR <br />I WALL BATT 'INSUL. <br />SOLID RIM BOARD BLOCKING <br />2x10 JOISTS © <br />16" O.C. U.N.O. <br />I <br />I <br />I <br />2 <br />fi <br />6 <br />I <br />INSULATE FLOOR <br />2 <br />OVER UNHEATED <br />I NO INSULATION AT <br />SPACES <br />I UNHEATED SPACES D1 <br />I <br />i <br />EXTERIOR <br />WALL AT FLOOR <br />2 <br />1-1/2" = 1'-O" <br />SECTION <br />LAP OUTER LAYER OF BUILDING PAPER <br />OVER FLASHING. INNER LAYER RUNS <br />BEHIND SIDING & TRIM <br />SEE DETAILS 7/15 <br />METAL FLASHING FOR BELLYBAND <br />FLASHING DETAIL <br />5/4 TRIM BEVEL TOP AND <br />BOTTOM OF BELLY <br />BAND 10 DEGREES <br />FURR STRIPS <br />16" O.C. <br />ALIGN WITH ADJACENT <br />TRIM AT DECKS OR <br />CANTILEVERED FLOOR <br />VERIFY ON ELEVATIONS <br />YPICAL EXTERIOR WALL <br />TYPICAL BELLY BAND <br />3 <br />Y = 1'-0" SECTION <br />UNIT <br />FULLY INSULATE CORNER <br />STUDS <br />16" OC 2x NAILER <br />4. <br />2 y y y y 1�2. <br />T E M <br />N UL i <br />6 -44/ <br />------------------------------ — <br />EXTERIOR EXTERIOR SIDING <br />�� & CORNER CONDITION <br />PER ELEVATIONS <br />4 TYPICAL EXTERIOR CORNER <br />3" = 1'-0" PLAN <br />Sheet Order: A B U F R E S <br />5052 REGISTERED <br />ARCHITECT <br />ROBERT E. WEIBLE <br />STATE OF WASHINGTON <br />CO <br />o, <br />a. N <br />o� <br />m <br />U) <br />a <br />T <br />o <br />o N <br />C � <br />L <br />U. <br />Q <br />0 <br />0 <br />m <br />3 <br />0 <br />N <br />'L <br />a <br />E <br />O]WOMEN <br />M <br />0. <br />wcl) <br />o <br />0 <br />y <br />0 <br />t <br />F— <br />Lu <br />Z <br />.F+ <br />0 <br />.j <br />75 <br />0 <br />0. <br />r <br />a <br />Job No.: <br />13-47 <br />Sheet No.: <br />D 3 <br />