Laserfiche WebLink
INSULATION <br />FOUNDATION PERIMETER - R-10 RIGID <br />INSULATION TO A DEPTH OF 24" OR TO TOP <br />OF FOOTING AT HEATED PERIMETER <br />WALLS: 2x6 WALLS WITH FIBERGLASS BATTS <br />OR BLANKETS - R21 <br />FLOORS OVER UNHEATED SPACES - R-30 <br />ATTICS AT TRUSSES - R-49 <br />(R-38 SHALL BE DEEMED TO SATISFY THE <br />REQUIREMENT OF R-49 WHEREVER THE FULL <br />HEIGHT OF UNCOMPRESSED INSULATION EXTENDS <br />OVER THE WALL TOP PLATE AT THE EAVES) <br />EXTERIOR DOORS: DOORS BETWEEN HEATED <br />AND UNHEATED SPACES SHALL BE U=0.30 <br />OR BETTER <br />WINDOWS: ALL WINDOWS AND SGD TO HAVE <br />U-FACTOR OF U=0.30 OR BETTER <br />INSULATE UNDER STAIRS AND IN WALL <br />CAVITIES ABOVE BOTTOM OF STRINGERS <br />GYPSUM WALLBOARD SCHEDULE <br />GYPSUM WALLBOARD (GWB) SHALL BE <br />USED THROUGHOUT ON INTERIOR WALLS, <br />INTERIOR SIDE OF EXTERIOR WALLS AND <br />CEILINGS EXCEPT AT EXTERIOR WALLS AND <br />COMMON WALLS REQUIRED TO HAVE A 1-HR <br />OR 2-HR FIRE -RESISTANCE RATING IN <br />WHICH CASE V8" TYPE 'X' GWB SHALL BE <br />USED. <br />N O T E S <br />15'- 4� » <br />I 2'- 9�2 12'-7" <br />6'-4" 6'-3" <br />I <br />2 1 I <br />I D3 D1 I <br />6-0 9-0 SL <br />..... ........... .................) <br />EGRESS <br />N <br />tt................. 1 <br />II � 11 <br />I <br />1 i oLO <br />' <br />1 8 14 II <br />� Master D1 D3 � <br />1 m Bedroom 18 <br />D3 1' <br />3'-3" 4'-10�2" 4'-0" <br />, I 1 <br />1 1�5 I I <br />Q �G� LOW WALL <br />42' A.F.F. 1 1 <br />LOCATE PLUMBING =�, 1 i` D5 1 <br />ROUGH -IN ACCOUNTING rn 1 24 TB�DN (' <br />FOR SHEAR PANELING a, 1 M. Bath <br />AND (2) LAYERS GWB 1 tic it <br />AT COMMON WALL Tp ' 48"x34" 1 <br />m' SHOWER N II <br />� 11 <br />FRAMING: 2x6's AT EXTERIOR WALLS <br />THE FIREPLACE SHALL BE LISTED BY UL OR FM AND <br />2x4's AT INTERIOR WALLS <br />SHALL BE INSTALLED IN ACCORDANCE WITH THAT <br />UNLESS NOTED OTHERWISE, <br />LISTING <br />SEE S1.1 FOR STUD SCHEDULE. <br />PROVIDE WATER RESISTANT GYPSUM WALLBOARD <br />............•••••• R-21 BATT INSULATION <br />BEHIND TUB AND SHOWER ENCLOSURE MATERIALS <br />- - - - - - 3�/2" ACOUST. INSUL. EACH SIDE <br />TO A HEIGHT OF 70" MINIMUM ABOVE THE <br />OF PARTY WALL, UNO. <br />DRAIN INLET. <br />CONCEALED SPACES SHALL BE FIRESTOPPED IN BOTH <br />NO PLUMBING, MECHANICAL EQUIPMENT, DUCTS OR <br />DIRECTIONS AT 10'-0" ON CENTER AND AT FLOORS. <br />VENTS SHALL BE LOCATED IN THE COMMON UNIT <br />TYPICAL, <br />SEPARATION WALLS PER IRC SEC. R302.2 (EXCEPTION) <br />ALL ESCAPE OR RESCUE WINDOWS FROM SLEEPING <br />ALL BEDROOM AND BATHROOM DOORS SHALL BE <br />ROOMS SHALL HAVE A MINIMUM NET CLEAR OPENING <br />UNDERCUT A MINIMUM OF 3/4" ABOVE THE ADJACENT <br />OF 5.7 SQUARE FEET. THE MINIMUM CLEAR OPENING <br />FLOOR COVERING. <br />HEIGHT DIMENSION SHALL BE 24". THE MINIMUM CLEAR <br />OPENING WIDTH DIMENSION SHALL BE 20". SILL <br />THE FRONT DOOR SHALL BE OPENABLE FROM THE <br />HEIGHT SHALL BE NOT MORE THAN 44" ABOVE THE <br />INSIDE WITHOUT THE USE OF A KEY OR ANY SPECIAL <br />FLOOR PER IRC SEC. R310.1.1. <br />KNOWLEDGE OR EFFORT. IT MAY BE PROVIDED WITH A <br />NIGHT LATCH, DEAD BOLT OR SECURITY CHAIN, <br />WHERE SILL AT OPERABLE WINDOW IS LOCATED MORE <br />PROVIDED SUCH DEVICES ARE OPENABLE FROM THE <br />THAN 72 INCHES ABOVE FINISHED GRADE OR OTHER <br />INSIDE WITHOUT THE USE OF A KEY OR TOOL, AND <br />SURFACE BELOW, SILL HEIGHT SHALL BE MINIMUM 24 <br />MOUNTED NOT TO EXCEED 48" ABOVE THE FINISHED <br />INCHES ABOVE FINISHED FLOOR. PER IRC SEC. 312.2.1. <br />FLOOR. <br />ALL GLAZING SHALL CONFORM TO IRC SEC. R308.4, <br />STAIR NOTES: <br />HAZARDOUS LOCATIONS. GLAZING IN ALL DOORS SHALL <br />LOCATE HANDRAILS AT 34'-38" ABOVE THE <br />BE SAFETY GLAZED. ALL GLAZING WITHIN A 24" ARC <br />STAIR NOSING. <br />OF EITHER VERTICAL DOOR EDGE SHALL BE SAFETY <br />GLAZED. ALL GLAZING WITHIN 60" OF A HAZARDOUS <br />HANDRAIL GRASP DIMENSION SHALL BE BETWEEN 1" & <br />LOCATION, OR "WET SURFACE" SHALL BE SAFETY <br />1-1/4". PROVIDE CONTINUOUS HANDRAIL OR <br />GLAZED. <br />TERMINATE <br />AT NEWEL POSTS OR SAFETY TERMINAL. <br />PROVIDE -Y8" (MIN.) GYPSUM SHEATHING ON <br />WALLS BEHIND TUB/SHOWERS TO SATISFY FIRE <br />WHERE USED AS A GUARDRAIL, A MAX. OPENING OF <br />REQUIREMENTS AT UNIT SEPARATION WALLS CONDITION. <br />4". <br />o DR4ER 1 <br />1' J <br />I p I ILL.1 151; 0 CN I - <br />D3 mW <br />11;1 �W (0 <br />o d �, 1 <br />I, I � Bath WASHER'; II <br />I' 00 <br />18" TB 2-4 HCW <br />I' UP 3'-9" 3'-61 ( @ STEP <br />10 LOW WALL P14 <br />------------ <br />__ D5 42" A.F.F. <br />22"x30" 1 8 <br />6-0 (PASS 3 I ATTIC I D3 D1 <br />1 ACC <br />j <br />4'-10" 3'_6/ , = 1 1 <br />D1 L -_J <br />Tech i' 00 <br />A� , 00 D3 D1 Area 11 - <br />1 D8 Bedroom 1 1, <br />1 @ STEP 1 <br />2 I' <br />1 1 D1 I. <br />, DI <br />t........... 2 ............t� <br />D3 3- 6 SH <br />�i RD1 <br />EGRESS 2 1 <br />`ND3 ......... .........: D3 A D1 <br />3 <br />I 6-0 1-0 SL I <br />5'-0" 5'-0" 3'-1%" 3'-103/4" <br />2'-0" 10'-0" 7'-0" <br />UNIT F <br />UPPER LEVEL <br />FLOOR PLAN <br />1/4"=1'-0" <br />SEE U19 FOR INTERIOR ELEVATIONS <br />AND INTERIOR STAIR PLANS <br />19,-0" <br />2'-9f „ 12'-7„ <br />Y4" 12'-6J/2" 18 <br />!' D4 <br />i <br />I <br />Deck <br />D4 <br />3'-4Y4" 4'-9" 4 -53/ <br />I <br />5-0�4-0 DSL <br />........... p .... <br />\ SAFETY GLAZING' <br />N co - <br />f'... 1 20 <br />CN D5 <br />UL APPROVED <br />1 11 'I <br />ELECTRIC FIREPLACE <br />0 1 ` TILE HEARTH (OPTIONAL) <br />8 1 <br />P14Y <br />Living 01 D <br />8 D <br />d I D3 D1 <br />CONTINUE COMMON WALL <br />1 2, 6„ TYPICAL 11'-0%2" <br />_ N <br />01 ( D1 SOFFIT AT <br />`r 1 SIM. / - -g , <br />---- .- ---. - - - <br />N D5 <br />N <br />i QO <br />I " � <br />(D 0 <br />I I I <br />m � <br />d 1 Jl g <br />Kitchen <br />11 D4 <br />o <br />I <br />.. I 19 DW jl l <br />1 <br />i l p1 ---J , <br />....I.� SIM <br />6 f� <br />' <br />D4 '� <br />1 , <br />4 1 Gi <br />3 <br />8 1 <br />3 1' <br />1 <br />11 � <br />I <br />V-10 <br />�1 <br />1' <br />1 <br />1, <br />1 <br />�I <br />L.... Ln <br />D1 I �1 <br />i1 I STEP , @ P <br />li ------ -- -... .. .-----,-- a ----- <br />18 <br />1 2'-2" SOFFIT AT k48 <br />7-8 <br />2'-2" _ <br />I `n U ID3 D1 <br />INSULATE FLOOR OVER �, 10 2 1 <br />14 8 UNHEATED SPACE D5 D1 , <br />D3 D1 <br />1 18 z 11 7'-10" <br />' I D3 Dining I CEILING <br />I @STEP I HEIGHT _ <br />1 P vd ..: I N <br />1 1 -g�2 18, T6 1 <br />6 <br />t........... D3 .........1 <br />1 2 ,-0 3r0 SH <br />o <br />--y 2 1 1 z <br />`" D1 D3 <br />7-0 5 f 0 DSL <br />I <br />5'-0" 5'-0" 4'-7" 2'-5" <br />2'-0" 10'10" 7'-0" <br />I 19'-0" <br />L11011w, <br />1 /4"=1 '-0" <br />MAIN LEVEL <br />FLOOR PLAN <br />0 <br />00 <br />0 <br />1 <br />N <br />0 0 <br />1 1 <br />0) � <br />n n <br />0 <br />1 <br />N <br />2'-9,Y26'- 4Y4 6'-2y4» 3'-7,Y2» <br />I , <br />--- --- - Q- - - - - - - - - - - - r <br />! I <br />18C <br />D4 II <br />I II <br />2X4 FUR WALL <br />AT WH LOCATION <br />I <br />NOTE: PER IRC R302.6 MIN. <br />TYPE X GWB SHALL BE <br />APPLIED TO CEILING OF GARAGE <br />WHERE HABITABLE ROOMS ARE <br />ABOVE. MIN.Y2" GWB APPLIED TO <br />ALL WALLS, BEAMS, AND POSTS <br />WH <br />JI F <br />\ <br />I <br />9 <br />D2 <br />' <br />N <br />-vim <br />d- <br />1'-9y2" <br />UP <br />CW <br />Garage <br />- — - — <br />G <br />7 <br />TED <br />DEntry <br />FSELF-CLOS <br />0 <br />3 <br />3 <br />� <br />� <br />D1 <br />o <br />8-0 7-0 SOHD <br />11 16 I D2 <br />I _ D2 D5 j <br />L- - - - - - - - - - - - - - - - - J <br />-FLOOR ABOVE <br />-- - - - - - - - - - - - - - - - - - - - - - - - - ----------- <br />1'- 1)/2" 1'-1y2" <br />1'-10y2" 8'-0" 2'-0» 4'-10Y2" <br />L110 I k 2 9 <br />1/4"= V-0" <br />LOWER LEVEL <br />FLOOR PLAN <br />5052 REGISTERED <br />o ARCHITECT <br />i <br />r <br />ROBERT E. WEIBLE <br />STATE OF WASHINGTON <br />Sheet Order: A B U F R E S D 11 <br />U) <br />Z <br />o <br />y- <br />s <br />4 <br />a <br />z <br />0 <br />z <br />s <br />>Q <br />w <br />= <br />Q <br />af <br />w <br />U <br />w <br />a <br />a <br />� <br />13 <br />0 <br />0 <br />(fl <br />T <br />N <br />Q' <br />CD <br />i <br />aazo <br />v <br />o <br />LI. Z o " <br />Q CD <br />0 <br />a <br />Z O U <br />= O <br />m Q <br />J <br />U. o � <br />W <br />E <br />0 <br />M <br />0 <br />Q. <br />E <br />W <br />a <br />L <br />E <br />N <br />0 <br />i <br />L <br />VSys <br />�' <br />0 <br />W <br />F— <br />> <br />w <br />z <br />i <br />4-0 <br />0 <br />0 <br />O <br />0. <br />t <br />a <br />Job No.: 13-47 <br />Sheet No.: <br />U10 <br />