Laserfiche WebLink
PROJECT TEAM <br />Owner/Developer <br />Polygon WLH, LLC <br />nnn <br />o,...eet <br />11624 SE <br />5t Suit_ <br />Bellevue, WA 98005 <br />(425)586-7700 <br />Architect: <br />Milbrandt Architects, Inc., P.S. <br />25 Central Way, Suite 210 <br />Kirkland, WA 98033 <br />(425) 454-7130 <br />Structural Engineer <br />CT Engeneering, Inc. <br />180 Nickerson St. Suite 302 <br />Seattle, WA 98109 <br />(206)285-4512 <br />Civil Engineer/Surveyer <br />Core Design, Inc <br />14711 NE 29th Place, Suite 101 <br />Bellevue, WA 98007 <br />(425) 885-7877 <br />Landscape Architect <br />Core Design, Inc <br />14711 NE 29th Place, Suite 101 <br />Bellevue, WA 98007 <br />(425)885-7877 <br />GENERAL NOTES <br />1. Comply with 2012 IRC and all applicable codes and ordinances of the local <br />jurisdiction and the State of Washington. <br />2. Do not scale drawings. <br />3. Verify all rough -in dimensions for equipment provided in this contract or by <br />others. <br />All rough -ins shall be approved and fireblocking shall be installed prior to <br />framing inspection. <br />4. Verify size and location of and provide all openings through floors and walls, <br />furring, anchors, inserts, rough bucks and backing for surface mounted items. <br />5. Provide furring as required to conceal mechanical and electrical work in all <br />finished areas. <br />6. All swinging doors not located by dimensions on plans, interior elevations, or <br />details shall be 3" from face of stud to edge of rough openings or centered <br />between room partitions as shown. <br />7. Plans are drawn assuming the following rough openings: <br />Swinging doors: Nominal size +2". <br />Bi-Fold doors: Nominal size +1-1/2". <br />Bi-Pass doors: Nominal size +0". <br />Windows: Nominal size +0". <br />Sliding glass doors: Nominal size +0". <br />8. Fill where required with earth free from organic material. Compact fill in <br />12" layers maximum. <br />9. "Finish Floor" refers to the top of concrete slab or top of wood floor <br />sheathing . <br />10. Exterior walls shall be 2x6 studs at 16" o.c. and interior walls shall be 2x4 <br />studs at 16" o.c., unless noted otherwise. <br />11. Unless otherwise noted, plan dimensions are to face of studs and face of <br />concrete walls. <br />12. Refer to interior elevations for cabinet and counter lengths, dimensions, <br />countertop materials and detail reference. Verify all existing dimensions <br />before installation. <br />13. Provide caulking between sole plates and subfloor and between rim joists at <br />both top plate and subfloor. <br />14. Hydrants shall be in service prior to start of framing. <br />15. Through penetrations and membrane penetrations of rated wall or <br />floor/ceiling assembly will require Firestopping per IFC 703. <br />See detail 13/Dl for diagram of specifics. <br />16. Milbrandt Architects is not responsible for construction means, methods, <br />techniques or procedures, or for the safety precautions and programs in <br />connection with the work, and is not responsible for the failure of any <br />contractor or subcontractor to carry out the work in accordance with the <br />various contract documents and or governing jurisdiction, regardless of what <br />is shown on these drawings. <br />DEFERRED SUBMITTALS <br />Shop drawings and calculations are required for: <br />1. Roof trusses. See notes on sheet S1. Drawings and calculations will be <br />reviewed and stamped by a State of Washington Registered Engineer. <br />2. Firestopping details. Firestopping methods and materials shall be <br />determined by the Contractor except where details or notes are indicated in <br />these drawings. Firestopping locations are indicated in part by detail 13/131. <br />Contractor shall submit UL assembly details and product cuts of all relevant <br />situations to the Architect for conformance to the building design. Upon the <br />Architect's approval, they shall be submitted to the Building Official for <br />approval. Firestopping shall not be installed without City approval. <br />3. Electrical and Plumbing design and drawings. <br />4. Pre-engineered and per -fabricated deck and stair guardrail and handrail <br />systems. Drawings and calculations shall be reviewed and stamped by a State <br />of Washington Registered Engineer. <br />DESIGN LOADS <br />See sheet S 1.0 and S l . l for Design Loads. <br />ECLIPSE <br />A 190 Unit Townhome Development <br />Everett, Washington <br />PROJECT INFORMATION <br />Project Name: Eclipse <br />Scope: New construction of one hundred ninety (190) 3 story <br />Townhome units within thirty three (33) separate buildings. <br />SITE INFORMATION <br />Site Address: <br />2808 36th Pl. <br />Everett, WA 98201 <br />Land Use Zone: <br />Waterfront Commercial <br />Unit Count: <br />E Townhome <br />28 <br />F Townhome <br />36 <br />G Townhome <br />36 <br />El Townhome <br />60 <br />E3 Townhome <br />30 <br />Total <br />190 <br />Parking: <br />Garage Single <br />60 <br />Garage Side by Side <br />132 <br />Garage Tandem <br />128 <br />Standard Site <br />25 <br />Parallel Site <br />8 <br />Apron Open <br />256 <br />Total <br />609 <br />ENERGY NOTES <br />Reference: 2012 International Energy Conservation Code of The State of Washington <br />(2012 IECC-WA) Chapter 4 using climate zone eatagory 5 & marine 4 for all <br />calculations. <br />All residential units shall comply with the Requirements By Component Table 402.1.1. <br />Including but not limited to the following: Associated Notes/Details <br />Code Requirements Showing Compliance <br />Window U-Factor 0.30 Insulation Notes U1, U4, U7, U10 & U13 <br />Ceiling R-Value R-49 17 / DI <br />Wood Frame Wall R-Value R-21 int. 1, 3, & 4 / DI <br />Floor R-Value R-30 5/DI <br />Below Grade Wall 10/15/21 int. + TB NIA <br />Slab R-Value & Depth R-10, 2ft, or top of ftg. 1, 9, &10 / D2 <br />"int." (intermediate framing) denotes standard framing 16" o.c. with headers <br />insulated with a min. of R-10 (see 6/134) and corners fully insulated (see 4/D3). <br />All units need to have a certificate posted within 3 feet of the electrical distribution panel <br />listing the following information: R-values, U-values, duct air leakage test results, <br />building envelope air leakage test results, types and efficiencies of heating, cooling and <br />service water heating equipment per R401.3 <br />All insulation installation shall comply with table 402.4.1.1 <br />All units need to be tested and verified as having an air leakage rate not exceeding 5 air <br />changes per hour per R402.4.1.2 <br />All mechanical ducts in unheated space shall be insulated to a minimum of R-8 per R403.2.1 <br />Mechanical ducts shall be sealing tested per R403.2.2 and WSU RS-33 <br />Hot water piping shall be insulated to a minimum of R-4 in both heated and unheated spaces <br />per R403.4.2 <br />Water heaters in unheated spaces, or on concrete sirall be placed on minimum of R-10 <br />incompressible insulated surface per R403.4.3 <br />Mechanical ventilation shall be provided per R403.5 <br />Heating & Cooling equipment shall be sized per R403.6 <br />A minimum of 75% of all permanently installed lamps in lighting fixtures shall be <br />high -efficacy lamps per R404.1 <br />Additional Energy Efficiency Requirements (Energy Credits) per R06 & Table 406.2 <br />Unit El = Small Dwelling Unit - .5 points required <br />Option 5b Efficient Water Heating 1.5 points provided <br />Unit E3 = Medium Dwelling Unit - 1.5 points required <br />Option 5b Efficient Water Heating 1.5 points provided <br />See Insulation Notes on the Unit Plans, and Insulation and Energy Notes on sheet D5. <br />Unit E Option 5b 1.5 points <br />Unit E1 Option 5b 1.5 points <br />Unit E3 Option 5b 1.5 points <br />Unit F Option 5b 1.5 points <br />Unit G Option 5b 1.5 points <br />ACCESSIBILITY <br />All residential buildings are constructed under the 2012 IRC and per R320 must <br />meet the provisions of 2012 IBC - Chapter l I for Group R3 occupancy. As <br />shown below this project is exempt from all accessibility requirements. <br />IBC Chapter 11 - Accessibility: <br />• All proposed units are multistory units and are exempt from accessibility <br />requirements per 1107.7.2. <br />• In Group R3 where there are no required accessible Type A or Type B <br />units, there are also no accessible parking space requirements per 1106.2. <br />• Accessible entrances are not required to units that are not Type A or <br />Type B per 1105.1.6.2 <br />• Accessible routes are not required as there are no accessible buildings, <br />units or parking within the project per 1104.2 & 1 ] 04.3. <br />RATED <br />Assembly <br />ASSEMBLIES <br />Fire Rating <br />Detail <br />LIST OF DRAWINGS <br />Common walls separating dwelling units: <br />2-hour <br />8/D1 <br />A! <br />Covel Sheet <br />A1.1 <br />Cover Sheet <br />Exterior walls X 5-feet to assumed shared <br />1-hour <br />4/DI <br />A2 <br />Site Plan <br />property line: <br />Exterior walls X 5-feet or perpendicular <br />non -rated <br />I /DI <br />B1 <br />Building Type A <br />Building Floor Plans <br />to assumed shared property line: <br />B2 <br />Building Type B <br />Building Floor Plans <br />Walls separating private garages from living <br />%" GWB garage side <br />3/D1 <br />B3 <br />Building Type C <br />Building Floor Plans <br />space: <br />B4 <br />9 Type Building T e D <br />Building <br />9 Floor Plans <br />B5 <br />Building Type E <br />Building Floor Plans <br />Floor separating private garages from living <br />%" GWB garage ceiling <br />6/D1 <br />B6 <br />Building Type F <br />Building Floor Plans <br />space: <br />B7 <br />Building Type F <br />Building Floor Plans <br />Penetrations (Firestopping): <br />Per situation <br />13/D1 <br />B8 <br />Building Type G <br />Building Floor Plans <br />Membrane penetrations by ducts in garages: <br />26 ga. steel ducting <br />5/D1 <br />B9 <br />Building Type H <br />Building Floor Plans <br />B10 <br />Building Type H <br />Building Floor Plans <br />Bl l <br />Building Type I <br />Building Floor Plans <br />B12 <br />Building Type I <br />Building Floor Plans <br />VENTILATION NOTES <br />1. Design Criteria: 2012 International Residential Code and the 2012 <br />International Mechanical Code with Washington State amendments. <br />2. System Type: Whole house ventilation system using exhaust fans per section <br />M1507.3.4 operating intermittently using table M 1507.3.3(2). <br />2.1.1. Unit E Min required Whole House Fan (Qf=Qr/(Ef)) Qf= <br />45cfm/1x0.5 = 90cfm @ 50% operational time, switching on at <br />least once ever 3 hours. 1.0 max Sone rating. <br />2.1.2. Unit E1 Min. required Whole House Fan (Qf=Qr/(Ef)) Qf= <br />45cfm/1x0.5 = 90cfin @50% operational time switching on at <br />least once every 3 hours. 1.0 max Sone rating. <br />2.1.3. Unit E3 Min. required Whole House Fan (Qf--Qr/(Ef)) Qf= <br />45cfm/1 x0.5 = 90efm pia 50% operational time switching on at <br />least once every 3 hours. 1.0 max Sone rating. <br />2.1.4. Unit F Min. required Whole House Fan (Qf Qr/(Ef)) Qf= <br />45cfm/1x0.5 = 90cfm 450% operational time switching on at <br />least once every 3 hours. 1.0 max Sone rating. <br />2.1.5. Unit G Min. required Whole House Fan (Qf Qr/(Ef)) Qf= <br />60cfm/IX0.5 = 120cfm @50% operational time switching on at <br />least once every 3 hours. 1.0 max Sone rating. <br />3. Specifics: See Electrical Plans for Whole House Fan and Air inlet locations <br />4. Outdoor air inlets shall be provided by means of operable ports in window <br />frames each inlet providing a minimum of 4 square inches each and all doors <br />shall be undercut Y2" minimum above the finish floor. <br />Minimum Required Local Exhaust Rates per section MI507.4 <br />5. Kitchen Exhaust fans shall be per Table 1507.4 <br />(100 cfm intermittent of 25 cfm continuous) <br />6. Bathroom/Toilet Room Exhaust fans shall be <br />(50 cfm intermitant or 20 cfin continuous). <br />VICINITY MAP <br />N.I.S. <br />U1 <br />Unit E <br />Floor Plans <br />U2 <br />Unit E <br />Framing Plans <br />U3 <br />Unit E <br />Electrical Plans <br />U4 <br />Unit E1A, E1 B, El C, E1 D, E1 E & E1 F <br />Floor Plans <br />U5 <br />Unit E1A, E1 B, El C, E1 D, E1 E & E1 F <br />Framing Plans <br />U6 <br />Unit E1A, E1 B, E1 C, E1 D, E1 E & E1 F <br />Electrical Plans <br />U7 <br />Unit E3A, E3B, E3C & E3D <br />Floor Plans <br />U7.1 <br />Unit E3A & E313 <br />Floor Plans <br />U8 <br />Unit E3A, E313, E3C & E3D <br />Framing Plans <br />Ug <br />Unit E3A, E313, E3C & E3D <br />Electrical Plans <br />U10 <br />Unit F <br />Floor Plans <br />Ul l <br />Unit F <br />Framing Plans <br />U12 <br />Unit F <br />Electrical Plans <br />U13 <br />Unit G <br />Floor Plans <br />U14 <br />Unit G <br />Framing Plans <br />U15 <br />Unit G <br />Electrical Plans <br />U16 <br />Unit E <br />Interior Elevations & Stair Plans <br />U17 <br />Unit E1 <br />Interior Elevations & Stair Plans <br />U18 <br />Unit E3 <br />Interior Elevations & Stair Plans <br />U19 <br />Unit F <br />Interior Elevations & Stair Plans <br />U20 <br />Unit G <br />Interior Elevations & Stair Plans <br />F1 <br />Building Type A <br />Foundation Plan <br />F2 <br />Building Type A <br />Shear Plans <br />F3 <br />Building Type A <br />Roof Framing Plan <br />F4 <br />Building Type B <br />Foundation Plan <br />F5 <br />Building Type B <br />Shear Plans <br />F6 <br />Building Type B <br />Roof Framing Plan <br />F7 <br />Building Type C <br />Partial Foundation Plan <br />F8 <br />Building Type C <br />Partial Foundation Plan <br />Fg <br />Building Type C <br />Shear Plans <br />F10 <br />Building Type C <br />Roof Framing Plan <br />Fl l <br />Building Type D <br />Foundation Plan <br />F12 <br />Building Type D <br />Shear Plans <br />F13 <br />Building Type D <br />Roof Framing Plans <br />F14 <br />Building Type E <br />Foundation Plan <br />F15 <br />Building Type E <br />Shear Plans <br />F16 <br />Building Type E <br />Roof Framing Plan <br />F17 <br />Building Type F <br />Partial Foundation Plan <br />F18 <br />Building Type F <br />Partial Foundation Plan <br />F19 <br />Building Type F <br />Shear Plans <br />F20 <br />Building Type F <br />Roof Framing Plan <br />F21 <br />Building Type G <br />Foundation Plan <br />F22 <br />Building Type G <br />Shear Plans <br />F23 <br />Building Type G <br />Roof Framing Plan <br />F24 <br />Building Type H <br />Partial Foundation Plan <br />F25 <br />Building Type H <br />Partial Foundation Plan <br />F26 <br />Building Type H <br />Shear Plans <br />F27 <br />Building Type H <br />Roof Framing Plans <br />F28 <br />Building Type I <br />Partial Foundation Plan <br />F29 <br />Building Type I <br />Partial Foundation Plan <br />F30 <br />Building Type I <br />Shear Plans <br />F31 <br />Building Type I <br />Shear Plans <br />F32 <br />Building Type I <br />Partial Roof Framing Plan <br />F33 <br />Building Type I <br />Partial Roof Framing Plan <br />LIST OF DRAWINGS <br />R1 <br />Building Type A <br />Roof Plan <br />R2 <br />Building Type B <br />Roof Plan <br />R3 <br />Building Type C <br />Roof Plan <br />R4 <br />Building Type D <br />Roof Plan <br />R5 <br />Building Type E <br />Roof Plan <br />R6 <br />Building Type F <br />Partial Roof Plan <br />R7 <br />Building Type F <br />Partial Roof Plan <br />R8 <br />Building Type G <br />Roof Plan <br />R9 <br />Building Type H <br />Partial Roof Plan <br />R10 <br />Building Type H <br />Partial Roof Plan <br />Rl l <br />Building Type I <br />Partial Roof Plan <br />R12 <br />Building Type I <br />Partial Roof Plan <br />E1 <br />Building Type A <br />Building Elevations & Sections <br />E2 <br />Building Type B <br />Building Elevations & Sections <br />E3 <br />Building Type C <br />Building Elevations & Sections <br />E4 <br />Building Type D <br />Building Elevations & Sections <br />E5 <br />Building Type E <br />Building Elevations & Sections <br />E6 <br />Building Type F <br />Building Elevations & Sections <br />E7 <br />Building Type G <br />Building Elevations & Sections <br />E8 <br />Building Type H <br />Building Elevations & Sections <br />Eg <br />Building Type I <br />Building Elevations & Sections <br />S-1.0 <br />Structural Notes <br />S-1.1 <br />Structural Notes and Schedules <br />S-1.2 <br />Shearwall Schedule and Details <br />S-1.3 <br />Holdowns Schedule and Details <br />S-1.4 <br />SWSB Details <br />S-6.0 <br />Typical Concrete Details <br />S-9.0 <br />Typical Floor Framing Details <br />S-9.1 <br />Typical Roof Framing Details <br />S-9.2 <br />Framing Details <br />S-9.3 <br />Framing Details - Unit E1C & D <br />S-9.4 <br />Framing Details- Unit ElB,D,F & E3 <br />S-9.5 <br />Framing Details - Unit E & E3 <br />S-9.6 <br />Framing Details - Unit G & F <br />D1 Details <br />D2 Details <br />D3 Details <br />D4 Details <br />D5 Details <br />D6 Details <br />Sheet Order: A B U F R E S D I <br />5052 REGISTERED <br />ARCHITECT <br />ROBERT E. WEIBLE <br />STATE OF WASHINGTON <br />� co <br />o <br />S <br />a N <br />a � <br />0 <br />cc <br />o <br />a N <br />o <br />0 <br />L <br />U <br />m <br />Q_ <br />0 <br />3 � <br />a� <br />c` f0 <br />U <br />a H <br />Z <br />E <br />0. <br />O <br />C <br />W <br />o <br />= <br />o <br />o <br />L) <br />C0 <br />= <br />4 <br />V <br />� <br />� <br />o <br />LIJ <br />° <br />I- <br />w <br />Z <br />C <br />�.+ <br />.� <br />o <br />0 <br />0 <br />o <br />a <br />' <br />Q <br />Job No.: 13-47 <br />Sheet No.: <br />Al <br />