GEHERALHOTES: <br />A. GENERAL BUILDING INFORMATION <br />1. ZONING: M-2 <br />DESCRIPTION: APPROXIMATELY 2,000 SF, TYPE I-N CONSTRUCTION, SPRINKLERED <br />OCCUPANCY: S-3 <br />EXITS: ONE REQUIRED, TWO FURNISHED <br />B. CODE REQUIREMENTS: <br />1. ALL DESIGN AND CONSTRUCTION SHALL CONFORM TO THE REQUIREMENTS <br />OF THE UNIFORM BUILDING CODE (UBC), 1994 EDITION. <br />2. SOILS: SOILS ARE SILTY SANDS PER ORIGINAL SOIL BORINGS PERFORMED IN <br />1958. ALLOWABLE SOIL DESGIN VALUES PER UBC TABLE 18-1-A: <br />ALLOWABLE SOIL BEARING PRESSURE 1,500 PSF <br />ALLOWABLE SOIL FRICTION 0.25 <br />ALLOWABLE PASSIVE PRESSURE 150 PCIF <br />RETAINING WALLS (EQUIV. FLUID PRESS.) 50 PCF (RESTRAINED) <br />C. DESIGN LOADS: <br />1. DEAD LOAD WEIGHT OF ALL MATERIALS AND EQUIPMENT <br />ROOF SNOW LL 25 PSF <br />RAMP AND FLOOR LL 100 PSF <br />SEISMIC ZONE 3, 1 = 1.0, C = 2.75, Rw = 6 <br />WIND 80 MPH, EXPOSURE C <br />D. INSPECTION: <br />1. PERFORM SPECIAL INSPECTION, PER UBC SECTIONS 1701 AND 1703, AS <br />REQUIRED BY THE CITY OF EVERETT. ALL SOIL COMPACTION SHALL BE <br />SUPERVISED BY AN APPROVED TESTING LAB OR GEOTECHNICAL ENGINEER <br />AND SHALL BE TESTED PRIOR TO PLACEMENT OF REINFORCING STEEL. <br />E. EXISTING CONDITIONS: <br />1. CONTRACTOR SHALL VERIFY ALL ELEVATIONS, DIMENSIONS, AND EXISTING <br />CONDITIONS IN THE FIELD BEFORE PROCEEDING. DIMENSIONS NOTED AS <br />PLUS OR MINUS (±) INDICATE UNVERIFIED DIMENSIONS AND ARE <br />APPROXIMATE. NOTIFY THE ENGINEER IMMEDIATELY OF CONFLICTS OR <br />EXCESSIVE VARIATIONS FROM INDICATED DIMENSIONS. <br />2. CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS BEFORE <br />COMMENCING ANY DEMOLITION. CONTRACTOR SHALL PROVIDE ADEQUATE <br />SHORING AND BRACING OF ALL STRUCTURAL MEMBERS, EXISTING <br />CONSTRUCTION AND SOIL EXCAVATIONS, AS REQUIRED, AND IN A MANNER <br />SUITABLE TO THE WORK SEQUENCE. TEMPORARY SHORING AND BRACING <br />SHALL NOT BE REMOVED UNTIL ALL FINAL CONNECTIONS HAVE BEEN <br />COMPLETED IN ACCORDANCE WITH THE DRAWINGS AND MATERIALS HAVE <br />ACHIEVED DESIGN STRENGTH. <br />3. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL SAFETY PRECAUTIONS AND <br />THE METHODS, TECHNIQUES, SEQUENCES, OR PROCEDURES REQUIRED TO <br />PERFORM THE WORK. <br />F. CONCRETE: <br />1. CONCRETE WORK SHALL CONFORM TO ALL REQUIREMENTS OF' CHAPTER 19 <br />(ACI 318-95) OF THE UNIFORM BUILDING CODE EXCEPT AS MODIFIED BY <br />THESE NOTES. CONCRETE STRENGTHS SHALL BE VERIFIED BY STANDARD <br />28-DAY CYLINDER TESTS, UNLESS APPROVED OTHERWISE. CONCRETE <br />MIXES SHALL HAVE A 28 DAY STRENGTH, ft = 4,000 PSI. THE MIX DESIGN <br />SHALL BE IN CONFORMANCE WITH UBC 1905. <br />2. ADMIXTURES: WATER -REDUCING ADMIXTURES MAY BE INCORPORATED IN <br />CONCRETE MIX DESIGNS, BUT SHALL CONFORM TO ASTM C494, AND BE <br />USED IN STRICT ACCORDANCE WITH THE MANUFACTURER'S <br />RECOMMENDATIONS. COC12 OR OTHER WATER-SOLUBLE CHLORIDE <br />ADMIXTURES SHALL NOT BE USED. <br />3. WATER/CEMENT RATIO: WATER/CEMENT RATIO SHALL BE MEASURED BY <br />WEIGHT AND SHALL BE BASED ON THE TOTAL CEMENTITIOUS MATERIAL. <br />WATER/CEMENT RATIO SHALL BE DETERMINED BY THE SUPPLIER BASED ON <br />STRENGTH REQUIREMENTS. <br />4. SLUMP: FIELD MEASURE SLUMP SHALL CONFORM TO THE SUBMITTED <br />CONCRETE MIX DESIGN, TOLERANCE OF SLUMP SHALL CONFORM TO ASTM <br />C94. <br />5. AIR CONTENT: AN AIR -ENTRAINING AGENT CONFORMING TO ASTM C260 <br />SHALL BE USED IN ALL CONCRETE MIXES FOR WORK WHICH IS EXPOSED TO <br />WEATHER. THE AMOUNT OF ENTRAINED AIR SHALL BE 5% ± 1 % BY VOLUME. <br />THE AMOUNT OF ENTRAINED AIR SHALL BE MEASURED IN THE FIELD AT THE <br />DISCHARGE END OF THE PLACING HOSE. <br />6. CURING: IF THE AIR TEMPERATURE WILL EXCEED 75' F. WITHIN 48 <br />HOURS OF PLACING CONCRETE, A MOIST CURE SHALL BE APPLIED TO THE <br />CONCRETE FOR A PERIOD OF 36 HOURS AF7ER FINISHING CONCRETE <br />SURFACES. <br />G. REINFORCING STEEL MATERIALS.- <br />1 DEFORMED BARS ASTM A615, GRADE 60 <br />SMOOTH WELDED WIRE FABRIC (WWF) ASTM Al 85 (Fy = 65 KSI) <br />2. REINFORCING SHALL BE SUPPORTED AS SPECIFIED BY THE CRSI MANUAL OF <br />STANDARD PRACTICE, MSP-1. REINFORCING STEEL SHALL BE DETAILED IN <br />ACCORDANCE WITH "ACI MANUAL OF STANDARD PRACTICE FOR DETAILING <br />REINFORCED CONCRETE STRUCTURES," ACI 315. <br />3. LAP ALL REINFORCING BARS AS NOTED ON THE DRAWINGS. MECHANICAL <br />OR WELDED BUTT SPLICES SHALL BE USED SUBJECT TO ENGINEER'S <br />APPROVAL. MECHANICAL SPLICES CALLED OUT ON THE PLANS SHALL <br />DEVELOP 125% OF THE SPECIFIED YIELD STRENGTH OF THE SPLICED BARS IN <br />BOTH TENSION AND COMPRESSION. <br />H. REINFORCED HOLLOW CONCRETE MASONRY: <br />Ln <br />1. HOLLOW CONCRETE UNITS SHALL BE MEDIUM WEIGHT GRADE N-1 PER UBC <br />w IN 5100 <br />STANDARD 21-4, fm = 2,000 PSI. MORTAR SHALL BE TYPE S. GROUT SHALL BE <br />COURSE TYPE WITH A MINIMUM COMPRESSIVE STRENGTH OF 2,000 PSI AT 28 <br />DAYS. ALL METHODS AND MATERIAL SHALL CONFORM TO CHAPTER 21 OF <br />THE UBC. CONSTRUCTION SHALL BE PER UBC SECTION 2104 WITH GROUTING <br />PER TABLE 21-C. THE THICKNESS OF THE GROUT BETWEEN BLOCK UNITS <br />AND REINFORCING STEEL SHALL NOT BE LESS THAN 1/2� BETWEEN PARALLEL <br />REINFORCING BARS NOT LESS THAN 314. IF WORK IS STOPPED ONE (1) HOUR <br />OR LONGER, PROVIDE HORIZONTAL CONSTRUCTION JOINTS BY STOPPING THE <br />GROUT 1 11Z' BELOW THE TOP OF THE BLOCK. SEE DRAWINGS FOR REINFORCEMENT <br />REQUIREMENTS. SPECIAL INSPECTION IS REQUIRED. <br />2. VERTICAL CONTROL JOINTS SHALL BE PROVIDED IN MASONRY WALLS AS., <br />a <br />NOTED IN THE STRUCTURAL DRAWINGS WITH A MAXIMUM SPACING OF 45 -0 <br />0 <br />in <br />STEEL MATERIALS: <br />ui N 5050 <br />1. STRUCTURAL STEEL ASTIM A36 <br />STRUCTURAL TUBES ASTM A500, GRADE B <br />STEEL PIPE ASTM A53, GRADE 8 <br />STRUCTLIRAL BOLTS ASTM A325-N <br />ANCHOR BOLTS ASTM A307 (UNLESS NOTED OTHERWISE) <br />THREADED RODS ASTM A36M <br />WELDING ELECTRODES E70XX <br />HEADED SHEAR STUDS ASTM A108 <br />J. STRUCTURAL STEEL: <br />1. STRUCTURAL STEEL DESIGN, FABRICATION, AND ERECTION SHALL CONFORM TO <br />0 <br />0 <br />101 <br />THE REQUIREMENTS OF CHAPTER 22 OF THE UNIFORM BUILDING CODE. <br />w <br />N 5000 <br />2. BOLTED CONNECTIONS ARE TO BE OF HIGH STRENGTH ASTM A325 BOLTS AS SHOWN <br />UNLESS NOTED OTHERWISE. A MINIMUM OF TWO BOLTS IS REQUIRED FOR ALL <br />BEAM CONNECTIONS. CONNECTIONS ARE TO BE AS SHOWN ON THESE DRAWINGS. <br />3. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL ERECTION AIDS AND <br />JOINT PREPARATIONS THAT INCLUDE, BUT ARE NOT LIMITED TO, ERECTION <br />ANGLES, LIFT HOLES AND OTHER AIDS, WELDING PROCEDURES, R--_QUIRED <br />ROOT OPENINGS, ROOT FACE DIMENSIONS, GROOVE ANGLES, BACKING BARS, <br />COPES, SURFACE ROUGHNESS VALUES, AND TAPERS OF UNEQUAL PARTS, <br />4. NON -SHRINK GROUT: BASE PLATE GROUT SHALL BE NON -SHRINK TYPE <br />0 1 FIRE L <br />WITH MINIMUM f'c = 8,000 PSI. <br />0 <br />a <br />5. ALL WELDING SHALL BE IN CONFORMANCE WITH AISC AND AWS STANDARDS, <br />to <br />w <br />AND SHALL BE PERFORMED BY WABO CERTIFIED WELDERS USING L70XX <br />N 4950 <br />ELECTRODES. ONLY PREQUALIFIED WELDS (AS DERNED BY AWS) SHALL BE USED. <br />K. METAL DECK: <br />48" STL WATI <br />1 STEEL DECK SHALL CONFORM TO ASTM A446. GRADE A MINIMUM AND HAVE <br />A MINIMUM Fy = 38 KSI. THE GALVANIZED COATING SHALL CONFORM TO <br />ASTM A525j G60, OR G90 WHERE LEFT PERMANENTLY EXPOSED. <br />2. MINIMUM DECK GAGES ARE SHOWN ON PLANS AND ARE BASED ON 3-SPAN, <br />UNSHORED CONDITIONS. HEAVIER DECK GAGES MAY BE REQUIRED FOR <br />CONDITIONS OTHER THAN THESE, DEPENDING ON MANUFACTURER. SUBMIT <br />A CURRENT ICBO REPORT FOR APPROVAL PRIOR TO SHOP DETAILING. <br />3. DECK WELDING SHALL BE IN ACCORDANCE WITH AWS D1.3, "SPECIFICATION <br />FOR WELDING SHEET STEEL IN STRUCTURES." WELDERS SHALL BE <br />QUALIFIED BY WABO LIGHT GAUGE CERTIFICATION. <br />4. CONTRACTOR SHALL PROVIDE CLOSURE PLATES, FLASHING, AND ALL <br />MISCELLANEOUS GAGE METAL SHAPES NECESSARY TO COMPLETE THE <br />WORK, INCLUDING DECK SUPPORT AND DIAPHRAGM SHEAR TRANSFER. THE <br />MINIMUM END LAP SHALL BE f CENTERED OVER SUPPORTS. THE MINIMUM <br />BEARING REQUIRED SHALL BE 2". <br />5. THE STEEL ROOF DECK SHALL BE BHP STEEL BUILDING PRODUCTS TYPE B-36 ROOF <br />DECK WITH RIBS AT 6!' (NOMINAL) ON CENTER OF THE SIZE AND GAGE SHOWN ON <br />THE PLANS OR APPROVED EQUAL. ROOF DECK FASTENING SHALL BE AS SHOWN ON <br />2 <br />THE PLANS. <br />6. SUSPENDED CEILINGS, LIGHT FIXTURES. DUCTS, OR OTHER UTILITIES SHALL <br />1. <br />NOT BE SUPPORTED BY THE STEEL DECK. <br />7. HOLES OR COMBINATIONS OF HOLES IN NONCOMPOSITE ROOF DECK, WHICH <br />2. <br />CUT TWO WEBS WHICH ARE CLOSER THAN 2'-Cr O.C. IN ANY DECK SPAN. <br />REQUIRE DIRECTION FROM THE ENGINEER AND MAY REQUIRE DECK <br />3. <br />REINFORCEMENT. <br />L. OPEN WEB STEEL JOISTS: <br />1. JOISTS SHALL BE OF THE SIZE AND TYPE SHOWN ON THE DRAWINGS AND <br />SHALL CONFORM TO THE REQUIREMENTS OF THE STEEL JOIST INSTITUTE. <br />5. <br />JOISTS SHALL BE DESIGNED IN ACCORDANCE WITH THE UBC AND LOADS <br />DESCRIBED HEREIN. IN ADDITION, THEY SHALL BE ANALYZED FOR SNOW <br />DRIFTING REQUIREMENTS PER 1994 UBC APPENDIX, CHAPTER 16, DIVISION 1, <br />6. <br />SNOW LOAD DESIGN. <br />2. JOISTS SHALL BE SUPPLIED WITH THE PROPER BRACING AND BRIDGING TO <br />7. <br />PROVIDE LATERAL STABILITY OF ALL JOISTS. THE NET UPLIFT USED IN <br />DESIGN SHALL BE 15 PSF, PERPENDICULAR TO THE ROOF SURFACE. <br />& <br />M. HEADED SHEAR STUDS AND DEFORMED BAR ANCHORS: <br />1. ALL SHEAR STUDS SHALL BE 3/4- DIAMETER HEADED STUDS. STUD <br />LENGTHS AFTER WELD SHALL BE AS SHOWN ON THE DRAWINGS. <br />DEFORMED BAR ANCHORS SHALL BE OF THE SIZE AND LENGTH SHOWN ON <br />THE DRAWINGS. ALL STUDS AND DEFORMED BAR ANCHORS SHALL BE <br />AUTOMATICALLY END WELDED IN SHOP OR FIELD WITH EQUIPMENT <br />RECOMMENDED BY MANUFACTURER. <br />N. EXPANSION BOLTS: <br />01 <br />Plan Check No: B 56172 SEPA <br />Ap3licat.Date: 08 11�97 <br />ob Address: 2660 EDERAL AVE <br />LRK <br />:C FORLIFT TRUCKS <br />M JOIST ROOF <br />;ET 16- <br />�1,vlj-7qf /^' <br />z <br />0 <br />w <br />roo <br />Go <br />Cn <br />ft to <br />C1 <br />co <br />8 <br />31: <br />Cm <br />j <br />< <br />LL <br />u <br />Of <br />m <br />w <br />M <br />z W <br />m <br />LLJ <br />z <br />w <br />0 <br />bo- <br />la I <br />D <br />w <br />111!__ <br />0 <br />z <br />_j <br />I <br />w <br />z <br />w <br />0 <br />Al <br />z <br />5 <br />a. <br />w <br />V) <br />WELDING OF REINFORCING: WELDING OF REINFORCING IS REQUIRED ONLY X-1 UC)US CONCNM INSPMUum jo v 0 sc-Atz <br />10 0 <br />4 AS N OTED <br />WHERE INDICATED OR MAY BE ALLOWED IN OTHER AREAS WHEN 1. EXPANSION BOLTS SHALL BE ICBO APPROVED AND INSTALLED PER THE 0 *0 ots. <br />MANUFACTURER'S RECOMMENDATIONS. BOLT SPACING AND EMBEDMENTS 'I SHEET NO. <br />APPROVED BY THE ENGINEER. REMAS 3 VI_ <br />E SHALL BE AS DESIGNATED ON THE DRAWINGS. UNLESS OTHERWISE OR <br />CL comTwaox Wamw "meow - DJO <br />SPECIFIED, BOLTS MAY BE INSTALLED WITHOUT SPECIAL INSPECTION. <br />5. REINFORCING STEEL SHALL HAVE MINIMUM COVER AS SHOWN ON THE <br />Ln DRAWINGS. EXPANSION BOLTS IN CONCRETE SHALL BE WEDGE -TYPE ANCHORS, UNLESS VIELOW <br />L <br />R <br />r <br />LE <br />D <br />I <br />J <br />N <br />T <br />0 <br />1NO' <br />C kFr or 1a; <br />NOTED OTHERWISE, FROM THE FOLLOWING MANUFACTURERS OR AN Moo" Fr. V.. <br />C1 <br />S <br />APPROVED EQUAL: GUNNEBO, RAMSET/RED HEAD, RAWL, AND HILTI. o'THER AUGUST 1997 <br />co <br />f EXPIRES <br />r4C., <br />24 97-030 <br />00 <br />12600 Federal Ave <br />lm�xl �11P <br />-IIJ1[1-v RI-111-1111 I I Jill [II-91-11w I I I III 111111111 11111firl <br />T771111" w1ulpifkwurmll-111111 111111111111111111111 Ili 11111111 p,[r[tTrpTqi <br />b 3 4 5 6 7 8 9 10 11 12 13 14 1 1 5 <br />WESTCt�,TT R405-15' K0146 <br />LE 9C SS VE 66 Z6 LC OS 6Z 13?, LZ 9Z 90 VE 0-3 EZ le Oz� t 8t LL 9L 9L t7L CL ZL Ll OL 6 8 Z 9 9 '17 F e L" L 0 <br />111111tilIHIltHIIIII111tj <br />