Laserfiche WebLink
�EGE�ID SYMBO �S <br /> ABBREUTATIO �IS <br /> GE�IERA� NOTES <br /> SECTION LETTER �.S CEILING MOUNTED OCCUPANCY SENSOR <br /> OR DETAIL NUMBER DESIGNATION � SWITCH, OS INDICATES WTEGRAL OCCUPANCY SENSOR, D INDICATES & AND JT JOINT <br /> WALL SECTIONS S INTEGRAL DIMMER � AT 1. OBTAIN & POST REQUIRED CONSTRUCTION PERMITS FROM THE CITY OF EVERETT PRIOR TO COMMENCING CONSTRUCTION. <br /> BUILDING, S AB ANCHOR BOLT K KIP(S) <br /> #X # X # AND DETAIL REFERENCES � INTERCOM/SPEAKER 2. VERIFY ALL EXISTING CONDITIONS AND NOTIFY THE BOEING PROJECT CONSTRUCTION MANAGER SHOULD CONDITIONS DIFFER FROM DESIGN DOCUMENTS. <br /> ACP ACOUSTICAL CEILING PANEL KO KNOCK OUT <br /> �I 15A, 120V DUPLEX RECEPTACLE ACT ACOUSTICAL CEILING TILE <br /> SHEET NUMBER WHERE DETAILED �I20 20A, 120V, DUPLEX RECEPTACLE L LENGTH 3. THE SCOPE OF WORK INCLUDES ALL WORK WITHIN THE CURRENT REVISION CLOUD(S) ON EACH SHEEf. IF THERE IS NO CLOUD ON A SHEET THE ENTIRE SHEET IS IN THE SCOPE OF WORK. INFORMATION OR <br /> ADJ ADJACENT WORK (WHETHER CLOUDED OR NOT) REFERRED TO FROM WITHIN A CLOUD IS INCLUDED IN THE SCOPE OF WORK (I.E. - A SECTION OR DETAIL SYMBOL THAT LIES WITHIN A CLOUD ON A PLAN VIEW SHEET IS INCLUDED <br /> SHEET NUMBER REFERENCED FROM � 15A, 120V, FOURPLEX RECEPTACLE AFF ABOVE FINISHED FLOOR LB LAG B�LT IN THE SCOPE EVEN WHEN THE ACTUAL SECTION OR DETAIL DRAWN ON THE DETAIL SHEEf IS NOT CLOUDED,) <br /> AGG AGGREGATE LEN LENGTH <br /> I ^ 1\1 X� FIRE ALARM HORN/STROBE, xx INDICATES CANDELA RATING LF LINEAL FEET <br /> _i i REFERENCE TO DETAIL/ENLARGED PLAN AL ALUMINUM 4. KEEP ALL AREAS UNDER CONSTRUCTION CLEAR OF DEBRIS CAUSED BY THIS SCOP� OF WORK. STORE CONSTRUCTION MATERIALS AND EQUIPMENT IN AREA DESIGNATED BY THE BOEING PROJECT CONSTRUCTION <br /> � DATA TELEPHONE OUT�ET ALT ALTERNATE LL LIVE LOAD MANAGER. <br /> #X # X # l ----- I • FIRE SPRINKLER HEAD ALUM ALUMINUM LWR LOWER <br /> \ � 5. VERIFY DIMENSIONS ANO CONDITIONS SHOWN ON THE DRAWINGS AND ENSURE THAT THE JOINING OF TNE WORK OF VARIOUS TRADES MEETS APPROPRIATELY. BRING DISCREPANCIES ON THE DRAWINGS OR IN <br /> ANCH ANCHOR, ANCHORAGE <br /> ROOF/ACCESS HATCH MATL MATERIAL SPECIFICATIONS TO THE ATTENTION OF THE BOEING PROJECT CONSTRUCTION MANAGER IMMEDIATELY UPON DISCOVERY, THE C�NTRACTOR SHALL ADVISE BOEING, SUMMARIZE THE SITUATION AND PROVIDE <br /> X DEtAIL DESIGNATION � APA AMERICAN PLYWOOD ASSOC. MAX MAXIMUM RECOMMENDATIONS TO RESOLVING POTENTIAL CONFLICTS PRIOR TO SUBMITTING ANY REQUESTS FOR INFORMATION (RFIs). <br /> XXXX � TOILET APPD APPROVED Mg MACHINE BOLT <br /> SHEEf NUMBER WHERE DETAILED APPROX APPROXIMATE MBR MEMBER 6. CONFORM ALL WORK TO APPLICABLE CODES, REGULATIONS AND INDUSTRY STANDARDS. <br /> (IF SAME AS SHEET REFERENCED FROM) ASTM AMERICAN SOCIEtY OF ' <br /> URINAL TESTING MATERIALS MTL METAL 7. COMPLY WITH THE BOEING PROJECT CONSTRUCTION MANAGER FOR CONSTRUCTION AREA AND SEGURITY REGULATIONS. <br /> X SECTION/DEfAIL DESIGNATION BTWN BEfWEEN M NR M NNMUMCTURE(R) g, PROVIDE, AS IF DRAWN IN FULL, REPETITIVE FEATURES NOT FULLY SHOWN OR NOTED ON THE DRAWINGS. <br /> BLDG BUILDING <br /> XXXXX XXXXX SHEET NUMBER WHERE DEfAILED O LAVATORY BLKG BLOCKING MISC MISCELLANEOUS 9. DIMENSIONS ON DRAWINGS ARE TAKEN TO THE FACE OF MASONRY AND/OR CONCRETE WALLS, METAL STUDS, AND TO THE CENTERLINE OF COLUMNS, UNLESS OTHERWISE NOTED. <br /> BOT BOTTOM MO MASONRY OPENING <br /> BYD BEYOND MT MOUNT(ED) (ING) 10. DOOR OPENINGS ARE 6" FROM ADJACENT WALLS OR CENTERED IN ROOM WALL, UNLESS DIMENSIONED OTHERWISE. <br /> SHEET NUMBER REFERENCED FROM °�� MOP SINK C CHANNEL MTL METAL <br /> CB CATCH BASIN 11. PARTITIONS SHALL RUN FULL HEIGHT, FROM FLOOR TO FLOOR ABOVE UNLESS SHOWN OR NOTED OTHERWISE. <br /> N DF QRINKING FOUNTAIN CC CENTER TO CENTER N NORTH (COORDINATE) <br /> NORTH ARROW CEM CEMENT NF NEAR FACE 12• PLANS WHICH APPEAR AS "BACKGROUNDS" ON CIVIL, STRUCTURAL, PLUMBING, HVAC, ELECTRICAL DRAWINGS ETC., ARE FOR THE PURPOSE ONLY OF ILLUSTRATING GENERAL PLAN CONFIGURATION. SUCH <br /> CF CUBIC FEET NIC NOT IN CONTRACT <br /> BACKGROUNDS SHALL NOT BE USED FOR PORTIONS OF THE WORK OTHER THAN THAT PERTAINING TO THE TITLE OF EACH SHEE7. REFER TO THE APPROPRIATE SHEET FOR EACH SPECIFIC PORTION OF THE WORK. <br /> SANITARY NAPKIN/TAMPON DISPENSER CJ CONTROL JOINT N0. NUMBER 13. COORDINATE THE WORK OF ALL TRADES. REFER TO ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL, AND CIVIL DRAWINGS IN DETAIL FOR COORDINATION OF SPECIFIC TRADE REQUIREMENTS. COORDINATE <br /> ELEVATION DATUM � � CL CENTER LINE NOM NOMINAL ALL ROUGH-IN REQUIREMENTS FOR EQUIPMENT FURNISHED BY CONTRACTOR OR BY OTHERS FOR THIS PROJECT. <br /> OR SPOT ELEVATION <br /> CLG CEI�ING NTS NOT TO SCALE 14. PROVIDE MANUFACTURERS INSTALLATION INSTRUCTIONS TO THE BOEING PROJECT CONSTRUCTION MANAGER WHENEVER SUCH INSTRUCTIONS ARE REFERENCED IN TNE CONSTRUCTION NOTES. <br /> CLR CLEAR(ANCE) <br /> PAPER TOWEL DISPENSER/DISPOSAL COL COLUMN OA OVERALL 15. CONTRACTOR SHALL SUBMIT INFORMATION FOR ANY PROPOSED EQUIPMENT TO BE USED IN LIEU OF SPECIFIED EQUIPMENT TO THE ARCHITECT FOR APPROVAL PRIOR TO PURCHASE AND INSTALLATION. <br /> � COMP COMPRESS(ED) (ION) 0/C ON CENTER <br /> �'-j(' CEILING HEIGHT A.F.F. OD OUTSIDE DIAMETER 16. CONTRACTOR SHALL COORDINATE WITH THE BOEING PROJECT CONSTRUCTION MANAGER FOR STAGING AREAS WHERE CONTRACTOR MAY STORE NEW OR SALVAGED MATERIALS TO BE REUSED IN LATER PARTS OF THIS <br /> 8 CONC CONCREfE <br /> DOUBLE ROLL TOILET PAPER DISPENSER CONC-S CONCREfE - SEALED OF OUTSIDE FACE PROJECT AND WHERE MATERIALS TO BE STAGED BY BOEING ARE TO BE LOCATED. <br /> XXXXXX ROOM NAME CONC-P CONCREfE - POLISHED OFCI OWNER FURNISHED CONTRACTOR <br /> XXXX ROOM NUMBER �—'� HANDICAP GRAB BAR, 1 1 j2" O.D. CONN CONNECTION INSTALLED 17. THE CONTRACTOR SHALL MODIFY (RELOCATE, SHORTEN, LENGTHEN, RAISE, LOWER, CAP) THE EXISTING LANDSCAPE PLANTING & IRRIGATION SYSTEM AS NECESSARY TO PROPERLY MAINTAIN PIANTING IRRIGATION AND <br /> OPG OPENING COORDINATE WITH THE LAYOUT OF THE NEW DOCK ACCESS DRIVEWAY. <br /> � CONST CONSTRUCTION OPP OPPOSITE, OPPOSITE HAND <br /> TOILET SEAT COVER DISPENSER <br /> XX DOOR NUMBER CONT CONTINUOUS, CONTINUE OTS OPEN TO STRUCTURE 18. SYMBOLS SHOWN ON LEGEND/SYMBOLS LIST ARE NOT ALWAYS USED IN DRAWINGS. VERIFY EXISTING MATERIAL AND SEE CONSTRUCTION NOTES FOR MATERIAL CALLOUTS. <br /> CONTR CONTRACT(OR) <br /> EARTH, DIRT, UNDISTURBED CT CERAMIC TILE PAR PARALLEL 19. WHERE EXISTING WORK IS DAMAGED, CUT OR DEFACED AS A RESULT OF DEMOLITION OR PERFORMANCE OF NEW WORK, THE CONTRACTOR IS TO PATCH AND REPAIR THE EXISTING TO MATCH ADJOINING SURFACES. <br /> X PARTITION/WALL TYPE <br /> CTSK COUNTERSUNK PCC PRECAST CONCRETE REPAIRED FINISHES SHALL BE EXTENDED TO THE NEAREST VISUAL BREAK IINES SUCH AS CORNERS, CEILING LINES, TOP OF BASE, CHANGE IN MATERIAL OR SIMILAR. <br /> -- =— EARTH, DIRT, COMPACTED CW CURTAINWAL� PCF POUNDS PER CUBIC FOOT 20. ALL PENETRATIONS OR RECESSES LOCATED WITHIN FIRE RATED PARTITIONS SHALL BE CONSTRUCTED TO MAINTAIN REQUIRED FIRE RATING OF THE PARTITION. <br /> CY CUBIC YARD(S) PERF PERFORATE(D) <br /> PERIM PERIMETER 21. ARCHITECTURAL REFLECTED CEILING PLANS INDICATE TNE FINAL LOCATIONS OF MECHANICAL AND ELECTRICAL COMPONENTS. SEE THE REFLECTED CEILING PLANS FOR LOCATIONS OF ITEMS IN THE CEILING; SEE <br /> INTERIOR ELEVATION � DIA DIAMETER <br /> X °'O °�° 8 STONE, GRAVEL, POROUS FILL ' PL PLATE DISCIPLINE SHEETS FOR ALL INFORMATION ABOUT THE MECHANICAL AND ELECTRICAL COMPONENTS fNDICATED ON ARCHITECTURAL REFLECTED CEILING PLANS. <br /> XXX XX X (WHERE SPACE IS LIMITED) oBMo� DE�MOLISH, DEMOLITION PLAM PLASTIC LAMINATE 22. PROVIDE CLOSURE, MEETING THE REQUIREMENTS OF GOVERNING FIRE AUTHORITIES, BETWEEN ALL FIRE RATED FLOORS, SHAFTS AND BUILDING PARTITIONS AND ALL PENETRATWG DUCTS, PIPES, CONDUIT, MECHANICAL, <br /> PLYWD PLYWOOD ELECTRICAL, AND OTHER ITEMS. <br /> �����/ BRICK, COMMON DEP DEPRESSED <br /> REVISION CLOUD WITH DIA DIAMETER PREFIN PREFINISH(ED) B 23. THE CONTRACTOR IS RESPONSIBLE FOR REVIEW OF THE STRUCTURAL, MECHANICAL AND ELECTRICAL DRAWINGS TO DETERMINE THE EXTENT OF CUTTING AND PATCHING WORK WITHIN THE BUILDING, BEYOND THAT <br /> REVISION LEiTER ��BEAK�� DIAG DIAGONAL P S ) SHOWN ON THE ARCHITECTURAL DRAWINGS. <br /> CERAMIC TILE DIM DIMENSION PRF PREFORMED <br /> DL DEAD LOAD PSF POUNDS PER SQUARE FOOT 24. AT METAL STUD PARTITIONS, STUDS ARE TO EXTEND FROM FLOOR TO FLOOR U.N.O.. WHERE THEY CANNOT DO S0, DUE TO INTERFERENCE WITH NEW OR EXISTING DUCTS, PIPING, ETC., PROVIDE BRACING TO - <br /> A DN DOWN PSI POUNDS PER SQUARE INCH STRUCTURE ABOVE TO PROVIDE FOR EQUIVALENT SUPPORT OF PARTITION; SUBMIT EQUIVALENT SUPPORT METHOD TO ARCHITECT FOR REVIEW. ALL FIRE RATED PARTITIONS SHALL BE CONSTRUCTED TO MAINTAIN THEIR <br /> � �"� �+� �' �^ �+� CONCRETE DS DOWNSPOUT RATING FROM FLOOR TO UNDERSIDE OF STRUCTURE ABOVE, U.N.O. <br /> ' � '� � '� '� '� '' PT POINT, PAINT <br /> DWG DRAWING PVC POLWINYL CHLORIDE 25. PROVIDE ACCESS DOORS AS INDICATED OR AS NECESSARY AND VERIFY WITH MECHANICAL AND ELECTRICAL SUBCONTRACTORS EXACT LOCATIONS OF ACCESS REQUIRED BY THEIR WORK. ACCESS MUST BE PROVIDED <br /> E EAST (COORDINATE) FOR ALL CONCEALED VALVES, DAMPER CONTROLS, FIRE DAMPER LINKAGES, CONCEALED JUNCTION BOXES, AND ELECTRICAL DEVICES OR ACCESSORIES. LOCATIONS AND SIZES OF EXPOSED ACCESS DOORS SHALL BE <br /> VCT CPT FLOOR MAT'L TRANSITION �Nsuv�T�oN: BAn, LOOSE FILL, BLANKET (E) EXISTING R RADIUS (CURVATURE) SUBMITTED TO THE ARCHITECT FOR REVIEW PRIOR TO INSTALLATION OF THE MECHANICAL AND ELECTRICAL EQUIPMENT. <br /> EA EACH R RISER <br /> EB EXPANSION BOLT RB RESILIENT BASE 26. THE CONTRACTOR SHALL BE RESPONSIBLE FOR SAFEfY IN THE AREA OF WORK IN ACCORDANCE WITH ALL SAFEfY CODES, REGUALTIONS AND BOEING REQUIREMENTS. <br /> �� FLOOR RECESS �►vsuu�T�oN: RIGID EF EACH FACE REF REFERENCE, REFER TO 27. THE CONTRACTOR SHALL RETAIN A FIRE PROTECTION ENGINEER LICENSED IN THE STATE OF WASHINGTON TO DEfERMINE/DESIGN THE MODIFIED FIRE SPRINKLER SYSTEM LAYOUT WITHIN THE AREA OF WORK. SAID <br /> EJ EXPANSION JOINT REINF REINFORCE(D) (ING) ENGINEER SHALL STAMP, SEAL AND CERTIFY THAT HIS/HER DESIGN IS IN COMPLIANCE W/ALL APPLICABLE CODES AND REGULATIONS. CONTRACTOR SHALL COORDINATE ALL NECESSARY MODIFICATIONS AS A RESULT OF <br /> � END WALL GUARD __� ALUMINUM EL ELEVATION REQ REQUIRE(D) (ING) SAID ENGINEER'S DESIGN. <br /> ELEV ELEVATION REV REVISION(S), REVISED <br /> EQ EQUAL RH RIGHT HAND 28. PORTIONS OF THE BUILDING WILL BE OCCUPIED DURING CONSTRUCTION. THE CONTRACTOR SHALL COORDINATE ALL WORK TO AVOID AS MUCH AS POSSIBLE ANY INCONVENIENCE TO BUILDING OCCUPANTS AND <br /> � CORNER GUARD �� ' �%�'% � EW EACH WAY RO ROUGH OPENING PROVIDE FOR THEIR SAFETY, ACCESS AND EGRESS THROUGHOUT THE PROJECT WORK. THE CONTRACTOR SHAL� FULLY SCREEN OFF AREAS UNDER CONSTRUCTION BY TEMPORARY SCREENS OR PARTITIONS AS <br /> �%%��%����%%� BRASS, BRONZE, COPPER NECESSARY TO LIMIT DUST, DIRT, NOISE, FUMES OR OBJECTIONABLE ODORS FROM ENTERING OCCUPIED AREAS. <br /> EXIST EXISTING <br /> EXP EXPOSED S SOUTH (COORDINATE) <br /> METAL, STEEL, IRON EXT EXTERIOR SECT SECTION <br /> CPT-1 FINISH DESIGNATION FAs FASTEN(ER) SF SQUARE FEET ; <br /> X --- FF FINISHED CEILING SHT SHEEf <br /> GRID/GRID BUBBLE AND �`�:������.�.��I PLASTER: SAND, CEMENT, GROUT FF FACTORY FINISH SIM SIMILAR <br /> CENTERLINE <br /> FF FINISHED FLOOR SQ SQUARE <br /> --- --- --- -- CONSTRUCTION ABOVE OR � '`j� � � �`�� '� ' ��� PLASTER: GYPSUM WALL BOARD FGR FINISH GRADE <br /> SST, SS STAINLESS STEEL <br /> BELOW, BEYOND QR BEHIND (HIDDEN) FH FiRE HYDRANT ST STRUCTURAL TEE, STAIN <br /> FIN FINISH(ED) STD STANDARD <br /> CONSTRUCTION "FIAG° NOTE FOR SPECIFIC �-�� WpOD; FINISH STL STEEL <br /> � FND FOUNDATION <br /> CONSTRUCTION DIRECTIVE FOC FACE OF CONCRETE STR STRUCTURAL <br /> FOF FACE OF FINISH SYM SYMMETRY,SYMMETRICAL <br /> GENERAL "BOAT'� NOTE FOR WOOD: ROUGH CONTINUOUS FOIC FURNISHED BY OWNER/ SYS SYSTEM <br /> � SPECIFIC OR EXISTING HISTORICAL INSTALLED BY CONTRACTOR T&B TOP AND BOTfOM . <br /> INFORMATION. �-----� WOOD: INTERRUPTED BLOCKING FO FINISHED OPENING T&G TONGUE AND GROOVE <br /> FRO FOR REFERENCE ONLY TEMP TEMPORARY <br /> A WINDOW TYPE <br /> Ff FOOT THK THICK(NESS) <br /> XXX HANDRAILS, KICK PLATES AND OTHER PLYWOOD: SMALL SCALE UT FU�T�URE TOC TOP OF CURB <br /> TOC TOP OF CONCRETE <br /> PHYSICAL PROTECTION FV FIELD VERIFY TOL TOLERANCE � <br /> FEC� FIRE EXTINGUISHER PLYWOOD: LARGE SCALE GA GAGE TOS TOP OF STEEL <br /> GRFG GLASS FIBER REINFORCED GYPSUM TS STRUCTURAL TUBE <br /> FEC� FIRE EXTINGUISHER & CABINET GALV GALVANIZED <br /> GC GENERAL CONTRACTOR nP TYPICAL <br /> � �O � SUPPLY AIR DIFFUSER WALL TYPE: CONCRETE MASONRY (CMU) UBC UNIFORM BUILDING CODE <br /> GI GALVANIZED IRON UL UNDERWRITERS' LABEL <br /> � RE7URN AIR GRILLE GR GRApE UNO UNLESS NOTED OTHERWISE <br /> � FLOURESCENT LIGHT FIXTURE _ WALL TYPE: STEEL STUD GT GROUT UPR UPPER <br /> —� (PENDANT MOUNTED) GWB GYPSUM WALL BOARD <br /> VB VAPOR BARRIER <br /> �—� FLOURESCENT LIGHT FIXTURE �—�,-�, �=A,�i WALL TYPE: WOOD STUD HDNR HARDENER VCT VINYL COMP. TILE <br /> (PENDANT MOUNTED) <br /> HDWD HARDWOOD VERT VERTICAL <br /> � FLOURESCENT LIGHT FIXTURE ON EMERGENCY NIGHT HDWR HARDWARE VFY VERIFY ' <br /> LIGHT (NL) CIRCUIT �—�� WALL 1YPE: EXISTING HG HIGH GRADE VIF VERIFY IN FIELD <br /> O RECESSED OR PENDANT LIGHTING FIXTURE HM HOLLOW METAL W WEST (COORDINATE) - <br /> � RECESSED OR PENDANT UGHTING FIXTURE HORZ HORIZONTAL <br /> WF WIDE FLANGE <br /> HS NIGH STRENGTH WD WOOD <br /> � FLOURESCENT �IGHT FIXTURE ON EMERGENCY NfGHT -------- WALL TYPE: REMOVAL HT HEIGHT W/ WITH <br /> LIGHT (NL) CIRCUIT IBC INTERNATIONAL BLDG. CODE W/0 WITHOUT . <br /> � WALL SCONCE 1 ID INSIpE DIAMETER WRB WEATHER RESISTIVE BARRIER <br /> a WALL SCONCE 2 —��� WALL TYPE: PARTITION (7'-0" HIGH) WWF WELDED WIRE FABRIC 0 <br /> ID INSIDE DIMENSION <br /> � EXIT SIGN (CEILING UNIT) IF INSIDE FACE NOTE: REFER TO THE COLOR AND MATERIAL <br /> � EXIT SIGN (WALL MOUNT) WALL TYPE: GLASS IN INCH DESIGNATIONS/ABBREVIATONSINISH AND O <br /> � <br /> � <br /> N <br /> INCL INCLUDES (ING) N <br /> _ _ _ _ _ _ _ _ __ _— __ — __ ____ _ _--- o <br /> _ _ <br /> SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE DRAWN DA SUBTITLE CURRENT REVISION SYMBOL DA7E N <br /> ACCEPTABILITY DLR GROUP 07.29.08 �, <br /> — RECORD DRAWING 586209-00 DLR GROUP L.SEELEY o�.o�.os �o�� TH�s oEs�cN ANo�oR CHEC ED ABBREVIATIONS, SYMBOLS LEGEND, & GENERAL NOTES W2829162 B o5.24.� s o <br /> F;c(.!�iElt�❑ SPECIFICATION IS APPROVED �• SEELEY 09.17,08 SHEEi � <br /> A 40-092 BUILDING EXPANSION W2829162 MH RW 01.21.16 � �"���T� � <br /> BOE,�� ��� , APPROVED BY DEPT. DATE GN R TITLE 40-092 BUILDING EXPANSION � <br /> B 40-092 BUILDING EXPANSION — VE 90% IFP W2829162 MH RW 05.24.16 cHECKE� �2 <br /> SCQTF A'1�'OL � , <br /> ���r�QF��r����,���� APPRo�Eo B U I L D I N G 40-092 �a6 N0. COMP No. w <br /> W2829162 � <br /> J <br /> APPROVED DWG N0. <br /> ARCHITECTURAL MASTER COL. N/A EVERETT, WA 40-092—G2 <br />