Laserfiche WebLink
AB�REVIATIONS GENERAL NOTES INDEX OF DRAWINGS <br /> . < ANGLE CI CAST IRON QR ENCLOSED GL GLASS OR GLAZING LT LIGHT PNT PAINT SD SOAP DISPENSER OR TOP TOP OF PAVEMENT ARCHITECTURAL �+ � " � <br /> �� CENTER LINE CJT GONTROL JOINT EWC ELECTRIC WATER COOLER GLBM GLU-I_AM BEAM LWC LIGHT WEIGHT CONCRETE POL POLISH STORM DRAlN TOS TOP OF STEEL 1. DIMENSIONS ARE TO FACE OF STUD, CONCREfE OR CENTER LINE OF COLUMN, 1 �.� � <br /> [ C H A N N E L C L G C E I L I N G E Q E Q U A L G C G E NE R A L C O N T R A C T O R M A S M A S O N R Y P R P A I R S E C T S E C T I O N T O S L T O P O F S L A B U N L E S S O T H E R W I S E N O T E D. - COVER ' r <br /> � DIAMEI-ER OR ROUND CJ CONSTRUCTION JOINT EQPT EQUIPMENT EMERGENCY GND GROUND MATL MATERfAL PRCST PRECAST SF SQIJARE FEEf TOW TOP OF WALL G1.1 GENERAL INFORMATION °' <br /> # N U M B E R O R P O U N D C L K CAULKWG SHOWER/ GWB GYPSUM WALL BOARD MAX MAXIMUM PSF POUNDS PER SQUARE SHT SNEET TPD TOILET PAPER 2. DO NOT SCALE DRAWINGS; QIMENSIONS GOVERN. A1.1 OVERALL SITE PLAN ` �-�„'� �` <br /> � PENNY CLR CLEAR ESEW EYE WASH GYP GYPSUM MB MACHINE BQLT FOOT SHTG SHEATHWG DISPENSER A2.1 PARTIAL FLOOR PLAN - NORTH � �'�"'� <br /> 1 PERPENDICULAR CMU CONCRETE MASONRY EST ESTIMATE HB HOSE BI� MDO MEDIUM DENSITY PSI POUNDS PER SQUARE SIG SOLAR INSULATED TPH TOILET PAPER HOLDER 3. VEftIFY AL� EXISTING CONDITIUNS, DIMENSIQNS, DETAILS, ETC. NQTIFY ARCNITECT A2.2 PRRTIAL FLOQR PLAN - SOUTH • . ' <br /> (� PLATE UNIT EXH EXHAUST HBD HARD BOARD OVERLAY INCH GLAZING TPTN TOILET PARTITION OF ANY AND ALL DISCREPANCIES PRIOR TO PROCEEDING WITH THE WORK. A2.3 PARTIAL ROOF PLAN - NORTH � - � � <br /> AB ANCHOR BOLT CNTR COUNTER EX EXPANSION HC HOLLOW CQRE OR MDF MEDIUM DENSITY PT PRESSURE TREATED SIM SIMI�IAR TS TUBULAR STEEL A2.4 PARTIAL ROOF PLAN - SOUTH � , � . � . <br /> AC ACOUSTICAL OR ASPHALT CO CLEANOUT EXST EXISTING MANDICAP FISERBQARD PTQ PAPER TOWEL SK SINK N TELEVISION 4. WHEN CONSTRUCTION DETAILS ARE NOT SHOWN OR NOTED FOR ANY PART OF THE A3.1 SCHEDULES, WALL TYPES, WINDOW TYPES, ENLARGEQ PL/aNS, RESTROOM ELEVATfONS <br /> CONCREtE COL. COL.UMN EXP EXPOSED HD HAND DRYER MECH MECHANICAL DISPENSER SLR SEALER TYP TYPICAL WORK, DETAILS SHALL BE THF SAME AS FOR OTHER SIMILAR WORK. IF QUESTIONS A4.1 EXTERIQR ELEVATIQNS <br /> . A/C AIR CONDITIONING CONC CONCRETE EXT EXTERIOR HDR NEADER MEMB MEMBRANE PTD/R PAPER TOWEL SND SANITARY NAPKIN UL UNDERWRITERS CANNOT BE RESOLVED IN THIS MANNER, CONTACT THE ARCHITECT. A4.3 WALL SECTIONS <br /> ACP ACOUSTICAL PANEL CONN CONNECTION FA FIRE ALARM HDWD HARD WOOD MTL METAL DISPENSER AND DISPENSER L4BORATORY A8.1 EXTERIOR DETAILS <br /> ACT ACOUSTICAL TILE CONSTR CONSTRUCTION FB FIAT BAR HDWE HARDWARE MEZZ MEZZANINE RECEPTABLE SNR SANITARY NAPKIN UON UNLESS OTHERWISE 5. VERIFY ELEVATIONS & LOCATIONS TO BE JOINED BEFORE CONSTRUCTION. CONTACT 12503 Bel-Red Road, Suite 101 <br /> ADD ADQITNE C�NT CONTINUOUS FBD FIBER BOARD NM HOLLaW ME(�AL MFR MANUFACTURER PTN PARTITION RECEPTACLE NOTED ARCHITECT IF THEY DIFFER FROM TNOSE SHOWN ON DRAWINGS. STRUCTURAL �ellevue, WA 980C?5 <br /> ADH ADHfSIVE CORR CORRfQOR FBO FURNISHED BY OTHERS HORIZ HORIZONTAL MN MAN NQLE PTR PAPER TOWEL SNT SEALANT UR URINAL <br /> ADJ ADJACENT CPT CARPET FCIC FURN€SHED BY HR HOUR MW MINIMUM RECEPTABLE SPEC SPECIFICATION VAR VARIES 6. ALL ROUGH-INS TO BE APPROVED PRIOR TO FRAMING INSPECTION. S1.0 GENE�AL NOTES p 425 646 1818 f 425 646 414'f <br /> ADJT ADJUSTABLE CT CERA�IIC TILE CONTRACTOR INSTALLED HT HEIGHT MIR MIRROR PVC POLYVINYL CHLORIDE SPGL SPANDREL GLASS VCT VINYL COMP�SITION TILE � 51.01 SPECIAL INSPECTIONS <br /> AFF ABOVE FINISH FLOOR CTR CENTER BY CONTRACTOR HTG HEATING MISC MISCE�LANEOUS PVMT PAVEMENT SQ SQUARE VENT VENTILATOR 7. MECNANICAL, ELECTRICAL, AND PLUMBING ARE BIDDER DESIGN. PORTIONS OF THIS F ��10 SECTIONS <br /> AGG AGGREGATE CTSK COUNFER SINK FCTY FACTORY NVAG HEATING/VENTILIATION/ MO MASONRY OPENING QT QUARRY TILE SS SOLID SURFACWG VERT VERTICAL WORK SHOWN ON DRAWINGS IS FOR DESIGN INTENT OR FOR CQORDINATION ONLY. 7 S1. U DATI N SECTION <br /> AL ALUMfNUM CY CUBIC YARD FD FLOOR DRAIN AIR CONDITIONING MTD MOUNTED R RISER SST STAINLESS STEEL VEST VESTIBULE �RTIAL FOUNDATION PIAN <br /> ALT ALTERNATE D QEEP, DEPTH FDN FQUNDATION HWH HOT WATER HEATER MULL MULL.ION RA RETURN AIR SSK SERVICE SINK VNR VENEER 8. MECHANICAL DESIGN/BUILD CONTRACTOR SHALL PROVIDE A MECHANICAL S2.1 PARTIAL FOUNDATION PLAN <br /> AP ACCESS PANEL DBL DOUBLE FE FIRE EXTINGUSHER fD INSIDE DIAMETER N NORTH RAQ RADIUS STA STATION VR VAPOR RETARDER <br /> FEC FIRE EXTINGUSHER DIMENSION / VENTILATION SYSTEM CAPABLE QF SUPPLYING THE MINIMUM OUTDOOR AIR S2.2 PARTIAL ROOF FRAMING PLAN <br /> APPROX APPROXIMATE DEPT DEPARTMENT NIC NOT IN CONTRACT RB RESILIENT BASE STC SQUND TRANSMISSION VWC VWYL WALL COVERING QUANTITIES SPECIFIED !N THE 2015 IMC WITN WASHINGTON AMENDMENTS. S2.3 PARTIAL ROOF FRAMING PLAN <br /> ARCH ARCNITECTURAL DET DETAIL CABINET IG INSULATED GLASS NO/� NUMBER R�S ROD & SHELF CIASS W WEST S3.0 SCHEDULES <br /> AWF ACOUSTICAL WALI_ FABRIC DIA DIAMEiER FIN FINISH IN INCH NOM �JOMINAL RD ROOF DRAIN STN STAIN W/ WITH 9. ELECTRICAL DESIGN/BUILD CONTRACTOR SHALL PROVIDE AND INSTALL MEANS OF S5.0 ROOF SECTIONS <br /> AWP ACOUSTICAL WALL PANEL QIAG DIAGQNAL FL FLOOR INCL INCLUDE NRC NOISE REDUCTION RQ/0 ROOF DRAIN OVERFLOW STD STANDARD W�0 WITHOUT EGRESS ILLUMINATION AND ILLUMINATED EXIT SIGNS PER IBC SECTIONS 1006 ANO S6.0 PANEL NOTES � �1NDE OOD GART�AN <br /> SD BOARD DIM DIMENSION FLG F�ASHWG INSUL INSULATION COEFFICIENT REBAR REINFORCING BAR STL STEEL S6.1 PANEL ELEVATIONS <br /> WC WATER CLOSET 1011. <br /> BEfW BETWEEN DISP DISPENSER FLUOR FLUORESCENT INT INTERIOR NTS NOT TO SCALE REF REFERENCE, REFLECTED STQR STQRAGE WD WOOD S6.2 PANEL ELEVATIONS D E V E L U P I� E N T <br /> BLDG BUILDING DMPF DAMPPROOFING FOC FACE OF CONCRETE INV INVERT OA OVERALL REFR REFRIGERATOR STRL STRUCTURAL WDO WINDOW 10. BUILDING TO BE PROVIDED WITN AN NFPA 72 MONITORED FIRE ALAftM. � 56.3 PANEL ELEVATIONS <br /> BLK BLOCK DN QOWN FOF FACE OF FINISH JAN JANITOR OBS OBSCURE REfNF REINFORCED SUSP SUSPENDED WF WIDE FLANGE S6.4 PANEL ELEVATIONS <br /> SLKG BLOCKING DR p00R OR DRAIN FOIC FURNISH BY OWNER JST JOIST OC ON CENTER REQ REQUIRED SV SHEEf VINYL WG WIRE GLASS 11. BUILDING SHALL NAVE AN ESFR SPRINKLER SYSTEM. S6.5 PANEL ELEVATIONS P O B O X 3 513, B ELL E V UE, V�A 9 8 0 Q 9 <br /> BM BEAM DWR DRAWER INSTALL BY CQNTRACTOR JT JOINT OD OUTSIDE DIAMEfER/ REV REVISION SYM SYMMETRICAL +�M WIRE MESH <br /> BRG BEARING D S D O W N S P O U T FOlO FURNISH BY OWNER KO KNOCK OUT DIMENSION RH RIGHT HAND OR ROBE SWC SPECIAL WALL COVERING WOM WALK OFF MAT 12. DEFERRED SUBMITTALS: <br /> BOT BOTTOM DW pISNWASHER INSTALL BY OWNER KS KNEE SPACE ON OVERHEAD HOOK T TREAQ WP WATER PROOF STRUCTURAL JOISTS <br /> BSMT BASEMENT DWG DRAWING FOS FACE OF STUD LAB lABORATORY OPH OPPOSITE HAND RESIL RESILIENT TB TOWEL BAR WPT WQRKING POINT FIRE ALARM ANQ SPRINKLERS <br /> BUR BUILT UP ROOF E EAST FPW FREEZE PROOF WALL LqM LAMINATE OPNG OPENING RIQ RQUGN-IN ONLY T&B TOP & BOTCOM WR WATER RES,STANT PROJECT INFORMATION <br /> CAB CABINET EA EACH HYDRANT LAV IAVATORY O�P OPPOSITE RM ROQM T&G TONGUE 8c GROOVE WSCT WAINSCOT 13. ENSURE SPRINKLERS AND PIPING DO NOT INTERFERE DIRECTLY UNDER SKYLIGHTS. <br /> CB CATCH BASfN EB EXPANSION BOLT FS FULL SIZE LB LAG BOLT PBD PARTICLE BOARD RO ROUGH OPENING TG TEMPERED GLP,SS � WEIGHT <br /> CBU CEMENTITIOUS BACKER EJ EXPANSION JOINT FT FEET LF LINEAL FOOT PERP PERPENDICUTAR RT RESILIENT/RUBBER TILE THK THICK WWF WELDED WIRE FABRIC 14. ENSURE CORRECT OVERHEAD CANTILEVERED VEHICLE GATES ARE USEQ PER TNE PROJECT SCOPE: NEW BUILDING <br /> UNIT EIFS EXTERIOR INSULATED FTG FOOTING L LONG, LENGTH PL PLATE OR PROPERTY RUB RUBBER THR THRESHOLD XFMR TRANSFORMER FEDEX CRITERIA DOCUMENTS. <br /> CEM CEMENT EL FINISH SYSTEM FURR FURRING LG LAMINATED GLASS LINE RWL RAIN WATER I.EADER TIG TEMPERED INSULATED �(D YARD PROJECT ADDRESS: 7301 HARDESON RD <br /> CER CERAMIC ELEC ELEVATION FUT FUTURE LH LEF7 HAND PLAM PLASTIC LAMiNATE � <br /> CFM CUBIC FEET PER MINUTE ELEV ELECTRIC GA GAUGE LL LNE LOAD PLAS PLASTER SC SOLIQ CORE GIAZING <br /> EVERETT, WA 98203 <br /> S SOUT TKBD TACK BOARD 4 <br /> CG CQRNER GUARD EMER ELEVATOR GALV GALVANIZED LMS LIQUID MARKING PWD PLYWOOD SCD SEAT COVER DISPENSER TO TOP OF ENERGY CODE BUILQING OWNER: UNDERWOOD GARTIAND JOHNSON, LLC <br /> CHBD CHALK BOARD ENC� EMERGENCY ENCLOSURE GB GRAB BAR SURFACE PNL PANEL SCHQ SCHEQULE TOC TOP OF CONCRETE PO BOX 3513 <br /> SY�1�0 LS LI G HTI N G I N FQ R MATI 0 N �E�����E, WA 98009 <br /> T.L 2015 IBC 1. ENERGY CODE COMPLIANCE: PROPERTY TAX NO.: 28040100303500 <br /> ELECTRICAL POWER AND LIGHTING SYSTEMS (PER WSEC SECTION C405� WAREHOUSE AREAS: CONDITIONED TENANT: BUILDING SHE�L ONLY FOR FEpERAL EXPRESS <br /> A NORTH OFFICE AREAS: CONQITIONED <br /> COLUMN � C405.2.1 OCCUPANCY SENSOR CONTftOLS SHALL BE INSTALLED TO CQNTROL LIGHTS. COMPLIANCE METHOD: TOTAL BUI�DING PERFORMANCE <br /> a LINE/GRfD � REVISIQN/ CLOUDED AREA � DETAIL IDENTIFICATION/ ARCHITECT: SYNTHESIS PLLC <br /> PROJECT NORTH <br /> A9.1 SHEET NUMBER 12503 BEL-RED ROAD, SUITE 101 <br /> -- I-----� � LINE C405.2.1.t OCCUPANT SENSOR CONTROLS SHALL COMPLY WITH THE FQLLOWING: 2. INSULATION REQUIREMENTS: BELLEVUE, WA 98005 <br /> � � 1. AUTOMATICALLY TURN OFF LIGHTS WITHIN 30 MINUTES OF ALL OCCUPANTS LEAVING ROOF INSULATI�N: RIGID CONTINUOUS OVER DECK: R-22 425 646-1818 <br /> MATCH LINE EkTERIOR GIAZED THE SPACE. WALL INSULATfON: R-11 WITH WOOD STUDS � � <br /> INTERIOR ELEVATION Ap1 2. BE MANUAL ON OR SHALL BE CONTROLLED TO AUTOMATICALLY TURN TNE LIGNTING PERIMETER SLAB INSUlATION: NONE CQNTACT: RANDY BROWN <br /> A01 DOOR NUMBER 1 OPENING N0. ON TO NQT MQRE THAN 50 PERCENT POWER. SKYLIGHTS: U-0.062, SHGC=0.35 MAX. <br /> IDENTIFICATION/ <br /> WORK POINT, CONTROL A5.1 SHEET NUMBER EQUIPMENT EXCEPTION: FULL AUTOMATIC-ON CONTROLS SHALL BE PERMITTED TO CONTROL SECTIONAL DOORS: R-16 STRUCTURAL: SHUTLER CONSULTING ENGINEERS <br /> � POINT OR Dt�TUM POINT EQ-1 IDENTIFICATION LIGHTING IN PUBLIC CORRIDORS, STAIRWAYS, RESTROOMS, PRIMARY BUILDING ROLL-UP DOORS: R-16 12503 BEL-RED ROAD, SUITE 140 <br /> 1 KEY NOTE ENTRANGE AREAS AND LOBBIES, <br /> AND AREAS WHERE MANUAL-ON OPERATION WIDE SECTIONAL DOORS: R-7.7 (28'x14' AND 30'x14') BELLEVUE, WA 98005 <br /> FINISH (425) 450-4075 <br /> 3 SECTION IDENTIFICATION OFFICE ROOM IDENTIFICATION PNT-1 �DENTIFICATION WOULD ENDANGER THE SAFEIY OR SECURIIY OF TH� RQOM OR BUILDING 5 FIXED WINDOWS: U=0.38 CONTACT: JOHN HEADLAND � o <br /> � � OCCUPANTS. ENTRANCES: U=0.60 <br /> 1 WALL TYPE A3.1 SHEEI' NUMBER ��� NUMBER X FENCE LINE 3• SHALL INCORPORATE A MANUAL CONTROL TO ALLOW OGCUPANTS TO TURN LIGHTS <br /> OFF. 3. SNADI KYLIG�TSFICIENTS SHG�-o.35 MAX. CO D E I N FO R MATI O N <br /> C405.2.1.2 IN WAREHOUSES, THE LIGHTING IN AISLEWAYS AND OPEN AREAS SHALL BE FIXED WINDOWS: SHGC=0.40 MAX. 2015 IBC <br /> CONTROLLED WITH OCCUPANT SENSORS THAT AUTOMATICALLY REDUCE LIGHTING POWER ENTRANCES: SHGC=0.40 MAX. <br /> � � BY NOT LESS TNAN 50 PERCENT WHEN THE AREAS ARE UNOCCUPIED. THE OCCUPANCY Code Edition: 2q15 16C, 2015 IFC, 2015 lMC, 2015 UPC, 2015 WSEC (WAC 51-11), <br /> SENSOR SHALL CONTRQL LIGHTING IN EACN AISLEWAY INDEPENDENTLY, AND SHALL NOT 4. AIR LEAKAGE TESTING SHALL E3E CONDUCTED AND COMPLY WITH WSEC SECTION ICC/ANSI A117.1-20Q9; W�HINGTON STATE AMEN�MENTS TO THE ABOVE <br /> CONTROL LIGHTING BEYOND THE AISLEWAY BEING CONTROLLED BY THE SENSOR. C402.5.1.2 BUILDING TEST (WAC 51-50). �7 08/15/17 PERMIT REVISIONS <br /> C405.2.2 EACH AREA OF THE BUILDING THAT IS NOT PROVIDED WITH OCCUPANT SENSOR 5. WSEC ADDITIONAI EFFICIENCY PACKAGE OPTIQNS TO INCLUDE: 1) MORE EFFICIENT Amended by Local Jurisdiction Yes X No 6 SEE ASKs GONSTRUCTION COORDINATION <br /> , CONTRO�S OR DIGITAI. TIMER SWITCH CONTROLS SHA�L BE PROVIDED WITH TIME SWITCH NVAC PERFORMANCE IN ACCORDANCE WITH SECTION C406.2 AND 2) REDUCED <br /> CONTRQLS. Construction: New._.- Addition- Alteration X Repair_ � 08/01/17 CITY COMMENTS <br /> EXCEPTION: WHERE A MANUAL CONTROL PROVIDES LIGHT REDUCTION IN LIGHTING POWER IN ACCORDANCE WITH SECTION C406.3 <br /> ACCQRDANCE 4VITH SECTION C405.2.2.2, AUTOMATIC CONTROLS SHALL NOT BE BUILDING CIASSEFIGATION a VARIES TENANT REVISIONS <br /> REQUIRED FOR THE FOLLOWING: 1. SPACES WHERE AN AUTOMATIC ZO N I N G I N FO R MATI O N A. Occupancy CCassification (Sect. 302) B � S-1 / S-2 � � 07/20/2017 PLANNING COMMENTS <br /> SHUTOFF WOULD ENDANGER OCCUPANT SAFETY OR SECURITY. 2 05/09/2017 PERMIT <br /> 2. LIGHTING INTENDED FOR CONTINUOUS OPERATION. 1. Jurisdiction: EVEREIT, WASHINGTON B. Construction Classification (Section 602) <br /> 1. Type of Construction ���-� 1 04/10/2017 TENANT REVIEW <br /> C405.2.3 MANUAL CQNTROLS FOR LlGHTS SNALL COMPLY WITH THE FOLLOWING; 2. Present Zoning: �C-1 - OFFICE AND INDUSTRIAL PARK 2. Automatic Sprinklers Provided X Yes - No <br /> . 1. SHALL BE READILY ACCESSIBLE TO OCCUPANTS. issuE No. oarE ITEM <br /> 2 SHALL BE LOCATED WHERE THE CONTROLLEQ LIGHTS ARE VISIBLE, OR SNALL 3. Projected site use requires: NO ACTION C. Location of Property (642.1) SEE SHEEf A1.1 <br /> IDENTIFY THE AREA SERVED BY THE LIGNTS AND INDICATE THEIR STATUS. <br /> 4. Use Zone Adjacent Lots: N M-1 E M-1 S M-1 W M-1 Distance to 4penings Qpenings Fire Resistance ' e A . ' ' ' <br /> C4�5.2.4 pAYI.IGHT RESPONSIVE CONTROLS COMP�YING WITH SECTION C405.2.4.1 SMALL Property Line Permikted Protected of Exterior Wall <br /> BE PROVIDED TO CONTROL THE LIGHTING WITHIN DAYLIGHT ZONES IN THE FOLLOWING (Table 705.8) (Table 705.8) (Table 601 & 602) <br /> SPACES: 5. Special Regulations Applicable: t <br /> 1. SIDELIGHT DAYLIGMT ZONES A5 DEFINED IN SECTION C405.2.4.2 WITH MORE THAN North 151 Feet Yes X No Yes No X 2-HR D� � IG�II <br /> TWO GENERAL LIGHTING FIXTURES WITHIN THE PRIMARY AND SECONDARY SIDELIGHT A. Shoreline Management Act Yes No X East 97 Feet Yes X Na Yes No X 2-HR � Y <br /> Setback required <br /> DAY�IGHT ZONES. � Sauth 86 Feet Yes X No Yes No X 2-NR <br /> B. Ffood Plain or Waterway Yes No X <br /> 2. TOPLIGHT DAYLIGHT ZONES AS DEFINED IN SECTIQN C405.2.4.3 WITH MORE THAN West 88 Feet Yes X NoT Yes No X 2�HR S I�n�' y <br /> � TWO GENERAL LIGHTING FIXTURES WITHIN THE DAYLIGNT ZONE. C. Airport open use/glide path Yes No X - - - - <br /> D. Storm Woter Retention/Run-Off Yes No X �� 4 REGISTERED Randy Brown <br /> C405.2.6 DIGITAL TIMER SWITCH. FOR EACH OF THE FQLLOWING SPACE TYPES, WHEN E. Fire Lane Requirements No X D. Building Area ARCHITECT <br /> UNDER 300 SQUARE FEEI�, DIGITAL TIMER SWITCH CONTROLS MAY BE PROVIDED IN LIEU � Date. <br /> � QF OCGUPANCY SENSOR CONTROLS: 6. Setbacks and Buffers � � 1. Unlimited Building Area (507� <br /> 1. COPY/PRINT ROOMS. Setbacks Required: Front Yard 30 Rear Yard 15 X Section 507.1 _= Section 507.2 - Section 507.3 RAN ALI. LEE BROWN <br /> 2. STORAGE ROOMS. W Side Yard 15' E Side Yard 15' X Section 507.4 - Section 507.5 - Section 507.6 STATE OF WASHINGTON ��� �.��.�� <br /> 3. JANfTORIAL CLOSE�S , - Section 507.7 - Section 507.8 _� Section 507.9 N A SF <br /> Lanscape Buffer Required: All Sides 15 1 o.q.2:�� <br /> C405.2.8 AREA CONTROLS. THE MAXIMUM LIGHTING POWER THAT MAY BE CONTRQLLED 7. Easements, Vacations, restrictive convenants as applicable: OCCUPANCY LOAD�Per IBC Table 1004.1.2) -���00� <br /> FROM A SINGLE SWITCH OR AUTOMATIC CONTROL SHALL NOT EXCEED THAT WNICH IS SEE CIVIL DRAWINGS <br /> PRQVIDED BY A 20 AMPERE CIRCUIT LOADED TO NOT MORE THAN 80 PERCENT. A SPACE FUNCTION LOAD FACTOR AREA OCCUPANT LOAD <br /> MASTER CONTROL MAY BE INSTALLED PROVIDED THE INDIVIDUAL SWITCHES REI�AIN THEfR 8. Parking Office Business 100 SF 9,227 SF 92.3 Persons <br /> CAPABILITY TO FUNCTION INDEPENDENTLY. CIRCUIT BREAKERS MAY NOT BE USED AS THE guilding Shell (Office space area based on future planned tenant improvement) � � � • � ` � <br /> SOLE MEANS OF SWITCHING. Warehouse Warehouse 500 SF 113,059 SF 226.1 Persons <br /> Office 9,2:27 SF 2.5 Stall/1,000 SF 23.1 Stalls 122,286 SF 318.4 Persons <br /> * PORTIONS OF THIS SECTION THAT DO NOT APPLY TO THIS PROJECT ARE OMITfED. Warehousz (90�} 113,736 SF 1.0 Stall/1,000 SF 113.7 Stalls <br /> TOTAL 122,963 SF 136.8 Stalls U�� 6� - FedEx <br /> Parking Stalls Required _ 7 Access'rble ( 2 Van) 130 Parking 137 Total <br /> � Parking Stalis Provided 7 Accessible ( 2 Van� 200 Parking 207 Total NORTH 7301 Hardeson ��Qd <br /> VICIN�TY MAP Everett, WA 98203 <br /> . Standard: 200 SIZE: 9`-0" x 18'-6" <br /> Compact: (} <br /> �, PROJECT <br /> � LUCATION • s ' • <br /> LEGAL DESCRIPTION MERRiLCREEK P��� � <br /> � RELEASc FOR: PERMIT <br /> . _ �� LOT 3, MOUNTAIN VIEW BUSINESS CENTER BINDING SITE PLAN DIVISION 7, ACCORDING TQ TNE BINDING y � T�T�E: CODE INFORMATION <br /> � SITE PI_AN RECORDED UNDER AUDITOR S FILE N0. 2007Q8315065 AS AMENDED BY DIVISION 8 UNDER q� � <br /> � AUQITOR'S FILE N0. 201112145001, RECORDS OF SNOHOMISH CQUNTY, WASHINGTON, BEING A PORTION � �J� � MADISON ST <br /> ; OF THE SOUTNWEST Qt1ARTER, AND TNE WEST HALF OF SOUTHEAST QUARTER OF SECTION 1, TOWNSNIP � ��,c,� �� <br /> � 28 NORTN, RANGE 4 EAST OF THE WILLF�MET�E MERIDIAN, AND OF THE NORTHWEST QUARTER OF SECTION �� <br /> ��' 12, TOWNSHIP 28 NORTH, RANGE 4 EAST OF THE WILLAME(TE MERIDIAN. SITUATED IN THE COUNTY OF ' ��,`� DESIGNED BY: DRAWN aX: <br /> x SNOHOMISN, STATE OF WASHINGTON. m 75TH ST SW �'\ � REviEwEo SY: APPROVEO eY. <br /> O <br /> _ � � �arE: 08 27 16 <br /> Y �„ <br /> � <br /> SR 526 �CPS\���� SHEET N0: • <br /> PRo�ECT No: 201205.01 .1 1 <br /> , W CASINO RD <br /> � � <br /> I <br /> � � <br /> ; EV�RETT, WASHINGTON � � <br /> OO 2�97 SY�d'�FBESIS�LLG <br /> � 4 <br />