<br /> Hospital Name Boon'No OE P° Sales Rep P. Date Common Anesthesia 550rnrn FLE.,sBc,,,,n-i:A,rticulating EDS200
<br /> Configuration ,000,1000
<br /> PROVIDENCE ERIC ROBINSON 5/19/2014 Room Name:207
<br /> VVASHINGTON
<br /> *Not to Scale
<br /> Arm Type:Articulating EDS200 Flange:Short Boom Fill Gas Connection
<br /> Label mm in Current Max Percentage Mfg. Amico t t f ......______c __
<br /> ---,---•-_,-:, .A.....,
<br /> A Room Height 3,200.4 126 28.96 36.00 80.44, Type: Chemetron I ,A ..--...,, ,
<br /> B Arm Length 1 1,000 39.4 Cable Kits Qty Hose Length 118ft 41 -'.- 0
<br /> C Arm Length 2 1,000 39.4 0678000174 1 Electric Connection ..T -•--,
<br /> -B (.:-/' I I
<br /> •''' 1 A-, , '.,-:,--, 7--,_ .,-,',-:' )--,
<br /> , ,.,,'
<br /> ,
<br /> D Drop Tube Length 450 17.7 Mfg. Le ton '.. -- '''—'; ' --4' ,:, _ .,--7
<br /> E Service Head Size 550 21.7 Type: NEMA FRO,
<br /> F Bottom of Svc Head to Floor 1,427.4 56.2 Conduit Length 118ft , D '''':'"'F--i-'; SERVICE HEAD
<br /> G Bottom of Arm to Floor 2,427.4 95.57 t:1 TOP VIEW
<br /> H Bottom of MFR to Floor 1,531.4 60.29 E , nI I
<br /> J Bottom of Svc Head to Floor 1,074.4 42.3
<br /> K Bottom of Svc Head to Floor 1,789.4 70.45 A
<br /> M Bottom of MFR to Floor 1,178.4 46.39
<br /> Slj
<br /> N Bottom of MFR to Floor 1,893.4 74.54 G
<br /> K
<br /> F 1
<br /> LS/M3 Monitor Location LS/M3 Monitor Monitors SiIViount ze Monitor Quantity H N
<br /> NA NA NA
<br /> Front Shelf and Accessories Back Shelf and Accessories
<br /> M
<br /> MFR Handle Shape Arm GCX Mounts MFR Handle Shape Arm GCX Mounts
<br /> 500mm IMFR HaRack NBack Inf
<br /> ndle _ None 0 None Bracket Handle NA NA Not Applicable
<br /> FrontInfusion one usion Rack
<br /> Front Shelf Schedule
<br /> Shelf No. I Shelf I Shelf Drawer
<br /> Outlet Connection Schedule I
<br /> Front Plate 1 P23413 Right Module I P12932 1 P12940 I P12932 1 NA Back Plate I P13017 Left Module 1 P12932 1 P12940 1 P12932 1 NA
<br /> Fl F2
<br /> ' RI ' R2, .BI, Li I 12
<br /> 1
<br /> F3 F4
<br /> R3 R4 -821 L3 L4
<br /> F5 F6
<br /> - 1 — , 83
<br /> F7 F8
<br /> R5 R6, i84, 15
<br /> - 1
<br /> Circuit Outlets Type Cohn Color Power Circuit Outlets Type Conn Color Power Circuit Outlets Type 'Conn Color Power Circuit Outlets Type Cohn Color Power
<br /> NA F1 Oxygen Gas NA NA El R1 20A/125V Duplex(2 Outlets) Electric Red Isolated E3,E4 B1 20A/125V Duplex(8 Outlets) Electric Red Isolated E5 L1 20A/125V Duplex(2 Outlets) Electric Red Isolated
<br /> NA F2 Med Air Gas NA NA El R2 20A/125V Duplex(2 Outlets) Electric Red Isolated NA B2 Phone/LAN Data NA NA E5 L2 20A/125V Duplex(2 Outlets) Electric Red Isolated
<br /> NA F3 Oxygen Gas NA NA NA R3 1 Gang Blank Plate NA NA NA NA B3 VGA/S-Video/BNC Data NA NA NA L3 1 Gang Blank Plate NA NA NA
<br /> NA F4 Med Air Gas NA NA NA R4 1 Gang Blank Plate NA NA NA NA B4 DVI Data NA NA NA L4 1 Gang Blank Plate NA NA NA
<br /> NA F5 Nitrous Oxide Gas NA NA E2 R5 20A/125V Duplex(2 Outlets) Electric Red Isolated NA B5 LAN/LAN Data NA NA E6 L5 20A/125V Duplex(2 Outlets) Electric Red Isolated
<br /> NA F6 WAGD Gas NA NA E2 R6 20A/125V Duplex(2 Outlets) Electric Red Isolated E6 L6 20A/125V Duplex(2 Outlets) Electric Red Isolated
<br /> NA F7 Vacuum Gas NA NA
<br /> NA F8 Vacuum Gas NA NA
<br /> PLEASE NOTE:The ratings of the outlets are listed above.See Section 13.2 of the Operations Manual for Branch Circuit Ratings.DO NOT exceed the Branch Circuits Outlet Rating.All Data Plates with"""are installed in the field.
<br /> Miscellaneous Electric Schedule Miscellaneous Gas Schedule
<br /> Circuit:EO I 20A/125V-Dedicated to EP Module and Motor 1 Total Circuits:7 Brake Regulator [' Nitrogen(125-200 PSI)
<br /> Proposal#: 1-21-TOO -3 Page 6 of/5
<br /> 1700 13th St-PGMC 2nd Floor Surgery-B1406-017